Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Operational Efficiency Evaluation of a Setup for Removing Stresses in the Steam Header of PGV-1000 Steam Generator

The effectiveness of a setup for removing stresses in the steam header of a PGV-1000 steam generator is evaluated. The evaluation is based on an investigation of the stress state by means of magnetic anisotropy measurements performed in the zone of the No. 111 weld seam of the hot header of steam generators operating in one of the power-generating units with a V-320 series reactor arrangement. Inspections made it possible to obtain cartograms of the distribution of the difference of the principal mechanical stresses along the perimeter of the weld connection of a PGV-1000 header equipped with a cooling mantle and headers without such a mantle. By means of statistical analysis of the data, a diagram of the distribution of the principal mechanical stresses was obtained. In addition, the distribution of the standard deviation of the principal mechanical stresses as a measure of the dispersion of a random quantity relative to its mathematical expectation was determined.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

System of Standard Neutron Sources on Neutronic Setups for Monitoring, Certification, and Calibration of Apparatus and Equipment

A methodological provision system for neutron measurements performed using neutronic setups is described. The metrological characteristics of standard sources of neutrons of five different groups, created based on nuclear reactors and 14 MeV neutron generators, are presented. The neutron spectra are calculated by a standard method and presented in a unified analytical form as a superposition of physically validated spectra.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Crosstalk in an FDM Laboratory Setup and the Athena X-IFU End-to-End Simulator

The impact of various crosstalk mechanisms on the performance of the Athena X-IFU instrument has been assessed with detailed end-to-end simulations. For the crosstalk in the electrical circuit, a detailed model has been developed. In this contribution, we test this model against measurements made with an FDM laboratory setup and discuss the assumption of deterministic crosstalk in the context of the weak link effect in the detectors. We conclude that crosstalk levels predicted by the model are conservative with respect to the observed levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Study on Peripheral Grain Structure Evolution of an AA7050 Aluminum Alloy with a Laboratory-Scale Extrusion Setup

A laboratory-scale hot extrusion setup was designed to investigate recrystallization and grain growth behavior of an AA7050 alloy during extrusion and subsequent heat treatments. Compared with industrial extrusion, the laboratory-scale process enabled rapid water quenching of extrudate with less delay so that the dynamic grain structure development was captured. After extrusion, static microstructure evolution in the extrudates was studied using salt bath annealing for 5 and 15 s at 490 °C and solutionization treatment for 1 h at 490 °C. The salt bath annealing was a simulation of the delay of press quenching in typical industrial extrusion practices. In the as-quenched extrudates, the peripheral region mainly exhibited continuous dynamic recrystallization and geometric dynamic recrystallization, whereas in the core region discontinuous dynamic recrystallization dominated. A <100> and <111> double fiber texture was identified in extrudates, and recrystallization behavior was found to be orientation dependent. The <100> oriented grains contained more sub-grain boundaries and better-defined sub-grains and had a higher tendency to fragment via continuous recrystallization, while the <111> oriented grains produced less sub-grain boundaries and did not recrystallize. Subsequent heat treatments resulted in static recrystallization and abnormal growth of the continuously recrystallized grains. Additionally, the effects of extrusion temperature (440, 480 and 520 °C) and punch speed (0.7, 1.4 and 2.1 mm/s) on grain structure were discussed. A revised grain structure evolution mechanism based on the observation of 7050 extrusion was proposed.

36 MATERIALS SCIENCE↗

Practical factors of envelope model setup and their effects on the performance of model predictive control for building heating, ventilating, and air conditioning systems

Model predictive control (MPC) for buildings is attracting significant attention in research and industry due to its potential to address a number of challenges facing the building industry, including energy cost reduction, grid integration, and occupant connectivity. However, the strategy has not yet been implemented at any scale, largely due to the significant effort required to configure and calibrate the model used in the MPC controller. While many studies have focused on methods to expedite model configuration and improve model accuracy, few have studied the impact a wide range of factors have on the accuracy of the resulting model. In addition, few have continued on to analyze these factors’ impact on MPC controller performance in terms of final operating costs. Therefore, this study first identifies the practical factors affecting model setup, specifically focusing on the thermal envelope. The seven that are identified are building design, model structure, model order, data set, data quality, identification algorithm and initial guesses, and software tool-chain. Then, through a large number of trials, it analyzes each factor's influence on model accuracy, focusing on grey-box models for a single zone building envelope. Finally, this study implements a subset of the models identified with these factor variations in heating, ventilating, and air conditioning MPC controllers, and tests them in simulation of a representative case that aims to optimally cool a single-zone building with time-varying electricity prices. It is found that a difference of up to 20%25 in cooling cost for the cases studied can occur between the best performing model and the worst performing model. The primary factors attributing to this were model structure and initial parameter guesses during parameter estimation of the model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hardware-In-the-Loop Benchmarking Setup for Phasor Based Control Validation

Phasor Based Control is a novel approach to controlling Distributed Energy Resources that aims at relieving various constraints that arise in the distribution grid. It is a two-layer control system with a supervisory control that coordinates distributed controllers to reach voltage phasor targets. The distributed controllers use local synchrophasor measurements and operate as feedback controllers. This control method is currently under development with several algorithms being under consideration for both the central and distributed components. In this report, we present the experimental setup that was prepared to prototype a hardware implementation and validate the control method in Hardware-In-the-Loop.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dosimetric Effect of Intrafraction Motion and Residual Setup Error for Hypofractionated Prostate Intensity-Modulated Radiotherapy With Online Cone Beam Computed Tomography Image Guidance

Purpose: To quantify the dosimetric effect and margins required to account for prostate intrafractional translation and residual setup error in a cone beam computed tomography (CBCT)-guided hypofractionated radiotherapy protocol. Methods and Materials: Prostate position after online correction was measured during dose delivery using simultaneous kV fluoroscopy and posttreatment CBCT in 572 fractions to 30 patients. We reconstructed the dose distribution to the clinical tumor volume (CTV) using a convolution of the static dose with a probability density function (PDF) based on the kV fluoroscopy, and we calculated the minimum dose received by 99% of the CTV (D{sub 99}). We compared reconstructed doses when the convolution was performed per beam, per patient, and when the PDF was created using posttreatment CBCT. We determined the minimum axis-specific margins to limit CTV D{sub 99} reduction to 1%. Results: For 3-mm margins, D{sub 99} reduction was {<=}5% for 29/30 patients. Using post-CBCT rather than localizations at treatment delivery exaggerated dosimetric effects by {approx}47%, while there was no such bias between the dose convolved with a beam-specific and patient-specific PDF. After eight fractions, final cumulative D{sub 99} could be predicted with a root mean square error of <1%. For 90% of patients, the required margins were {<=}2, 4, and 3 mm, with 70%, 40%, and 33% of patients requiring no right-left (RL), anteroposterior (AP), and superoinferior margins, respectively. Conclusions: For protocols with CBCT guidance, RL, AP, and SI margins of 2, 4, and 3 mm are sufficient to account for translational errors; however, the large variation in patient-specific margins suggests that adaptive management may be beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vector Analysis of Prostate Patient Setup With Image-Guided Radiation Therapy via kV Cone Beam Computed Tomography

Purpose: To analyze the daily setup variations in a cohort of intensity-modulated radiation therapy (IMRT) prostate cancer patients who had received daily image-guided RT without the use of fiducial markers to determine if daily image guidance is necessary. Methods and Materials: 2134 Kilovoltage (kV) cone beam computed tomography (CBCT) images were analyzed, with three shifts recorded for each image. The number of times that the vector of the combined shifts would have exceeded the planning tumor volume (PTV) margin was tallied. Then, the average scalar shift of the first five images was removed from all subsequent images for a given patient, and the number of days for which the shift vector was greater than the three-dimensional clinical tumor volume-PTV (3D CTV-PTV) margin (8 mm, created with rolling ball technique) was recorded. Additionally, the scalar shifts from every other fraction were studied to determine if the individual patient's shift vector would be adequately sampled if CBCT was not performed daily, thus reducing patient imaging dose without compromising treatment quality. Results: There were 297 cases where the vector shift was initially greater than the PTV margin. By correcting each patient's data set by the average shift of their first five images the total was 248 cases. By considering only every other image of each patient data set (after correction for the first 5 days), only 137 days in which the CTV was outside the PTV would have been seen. Conclusions: Daily imaging is recommended for prostate cancer IMRT patients in order to know the 3D (vector) position of the CTV and to ensure that it is always within the PTV margin. Correcting the data set by the average shift from the first 5 days reduces the overall number of outlier days but does not eliminate them completely.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Setup Accuracy of the Novalis ExacTrac 6DOF System for Frameless Radiosurgery

Purpose: Stereotactic radiosurgery using frame-based positioning is a well-established technique for the treatment of benign and malignant lesions. By contrast, a new trend toward frameless systems using image-guided positioning techniques is gaining mainstream acceptance. This study was designed to measure the detection and positioning accuracy of the ExacTrac/Novalis Body (ET/NB) for rotations and to compare the accuracy of the frameless with the frame-based radiosurgery technique. Methods and Materials: A program was developed in house to rotate reference computed tomography images. The angles measured by the system were compared with the known rotations. The accuracy of ET/NB was evaluated with a head phantom with seven lead beads inserted, mounted on a treatment couch equipped with a robotic tilt module, and was measured with a digital water level and portal films. Multiple hidden target tests (HTT) were performed to measure the overall accuracy of the different positioning techniques for radiosurgery (i.e., frameless and frame-based with relocatable mask or invasive ring, respectively). Results: The ET/NB system can detect rotational setup errors with an average accuracy of 0.09 Degree-Sign (standard deviation [SD] 0.06 Degree-Sign ), 0.02 Degree-Sign (SD 0.07 Degree-Sign ), and 0.06 Degree-Sign (SD 0.14 Degree-Sign ) for longitudinal, lateral, and vertical rotations, respectively. The average positioning accuracy was 0.06 Degree-Sign (SD 0.04 Degree-Sign ), 0.08 Degree-Sign (SD 0.06 Degree-Sign ), and 0.08 Degree-Sign (SD 0.07 Degree-Sign ) for longitudinal, lateral and vertical rotations, respectively. The results of the HTT showed an overall three-dimensional accuracy of 0.76 mm (SD 0.46 mm) for the frameless technique, 0.87 mm (SD 0.44 mm) for the relocatable mask, and 1.19 mm (SD 0.45 mm) for the frame-based technique. Conclusions: The study showed high detection accuracy and a subdegree positioning accuracy. On the basis of phantom studies, the frameless technique showed comparable accuracy to the frame-based approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-probe microstructure tracking during heat treatment without an in-situ setup: Case studies on martensitic steel, dual phase steel and β-Ti alloy

In-situ scanning electron microscopy observations of the microstructure evolution during heat treatments are increasingly demanded due to the growing number of alloys with complex microstructures. Post-mortem characterization of the as-processed microstructures rarely provides sufficient insight on the exact route of the microstructure formation. On the other hand, in-situ SEM approaches are often limited due to the arising challenges upon using an in-situ heating setup, e.g. in (i) employing different detectors, (ii) preventing specimen surface degradation, or (iii) controlling and measuring the temperature precisely. Here, we explore and expand the capabilities of the “mid-way” solution by step-wise microstructure tracking, ex-situ, at selected steps of heat treatment. This approach circumvents the limitations above, as it involves an atmosphere and temperature well-controlled dilatometer, and high resolution microstructure characterization (using electron channeling contrast imaging, electron backscatter diffraction, atom probe tomography, etc.). We demonstrate the capabilities of this approach by focusing on three cases: (i) nano-scale carbide precipitation during low-temperature tempering of martensitic steels, (ii) formation of transformation-induced geometrically necessary dislocations in a dual-phase steel during intercritical annealing, and (iii) the partial recrystallization of a metastable β-Ti alloy. - Highlights: • A multi-probe method to track microstructures during heat treatment is developed. • It enables the analysis of various complex phenomena, even those at atomistic scale. • It circumvents some of the free surface effects of classical in-situ experiments.

36 MATERIALS SCIENCE↗

Evaluation of the setup margins for cone beam computed tomography–guided cranial radiosurgery: A phantom study

The aim of this study is to evaluate the setup margins from the clinical target volume (CTV) to planning target volume (PTV) for cranial stereotactic radiosurgery (SRS) treatments guided by cone beam computed tomography (CBCT). We designed an end-to-end (E2E) test using a skull phantom with an embedded 6mm tungsten ball (target). A noncoplanar plan was computed (E2E plan) to irradiate the target. The CBCT-guided positioning of the skull phantom on the linac was performed. Megavoltage portal images were acquired after 15 independent deliveries of the E2E plan. The displacement 2-dimensional (2D) vector between the centers of the square field and the ball target on each portal image was used to quantify the isocenter accuracy. Geometrical margins on each patient's direction (left-right or LR, anterior-posterior or AP, superior-inferior or SI) were calculated. Dosimetric validation of the margins was performed in 5 real SRS cases: 3-dimesional (3D) isocenter deviations were mimicked, and changes in CTV dose coverage and organs-at-risk (OARs) dosage were analyzed. The CTV-PTV margins of 1.1 mm in LR direction, and 0.7 mm in AP and SI directions were derived from the E2E tests. The dosimetric analysis revealed that a 1-mm uniform margin was sufficient to ensure the CTV dose coverage, without compromising the OAR dose tolerances. The effect of isocenter uncertainty has been estimated to be 1 mm in our CBCT-guided SRS approach.

61 RADIATION PROTECTION AND DOSIMETRY↗

Exploring the Electrochemical Stability Window of an All-Solid-State Composite Cathode via a Novel Operando Tender XPS Setup

All-solid-state batteries (ASSBs) have the potential to provide greater energy density than conventional batteries based on liquid electrolytes. Here, an operando ASSB cell setup for tender X-ray photoelectron spectroscopy (XPS) was developed, and the interface of a Ni-rich layered transition metal oxide cathode active material (CAM) and an Li 6 PS 5 Cl (LPSCl) solid electrolyte (SE) was evaluated during initial charge/discharge cycles. After validating the cell performance against a conventional pouch cell operated at high compression, intermittent galvanostatic cycling was performed, and XPS data were recorded as a function of state of charge (SOC). Upon the initial charge of the cell to ≈3.3 V Li , the LPSCl appears to decompose into LiCl, Li 3 PS 4 , and polysulfides, whose amount gradually increases with potential. Upon further charge, at a potential higher than ≈3.8 V Li , initially, present sulfate and sulfite impurities decompose, and at ≈74% SOC (corresponding to a cathode potential of ≈4.10 V Li ), surface reconstruction of the CAM particles due to lattice oxygen release is detected. In addition, at potentials beyond ≈4.6 V Li , a decrease of the S 1s counts of the sum of the LPSCl, the thiophosphate, and polysulfide species suggests the formation of elemental sulfur that is lost via sublimation into the vacuum chamber.

25 ENERGY STORAGE↗

Simple Setup Miniaturization with Multiple Benefits for Green Chemistry in Nanoparticle Synthesis

The development of nanomaterials often relies on wet-chemical synthesis performed in reflux setups using round-bottom flasks. Here, an alternative approach to synthesize nanomaterials is presented that uses glass tubes designed for NMR analysis as reactors. This approach uses less solvent and energy, generates less waste, provides safer conditions, is less prone to contamination, and is compatible with high-throughput screening. The benefits of this approach are illustrated by an in breadth study with the synthesis of gold, iridium, osmium, and copper sulfide nanoparticles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Setup for in situ x-ray diffraction study of swift heavy ion irradiated materials

An in situ x-ray diffraction (XRD) setup is designed and installed in the materials science beam line of the Pelletron accelerator at the Inter-University Accelerator Centre for in situ studies of phase change in swift heavy ion irradiated materials. A high vacuum chamber with suitable windows for incident and diffracted X-rays is integrated with the goniometer and the beamline. Indigenously made liquid nitrogen (LN{sub 2}) temperature sample cooling unit is installed. The snapshots of growth of particles with fluence of 90 MeV Ni ions were recorded using in situ XRD experiment, illustrating the potential of this in situ facility. A thin film of C{sub 60} was used to test the sample cooling unit. It shows that the phase of the C{sub 60} film transforms from a cubic lattice (at room temperature) to a fcc lattice at around T=255 K.

36 MATERIALS SCIENCE↗

Combined experimental setup for spin- and angle-resolved direct and inverse photoemission

We present a combined experimental setup for spin- and angle-resolved direct and inverse photoemission in the vacuum ultraviolet energy range for measurements of the electronic structure below and above the Fermi level. Both techniques are installed in one ultrahigh-vacuum chamber and, as a consequence, allow quasisimultaneous measurements on one and the same sample preparation. The photoemission experiment consists of a gas discharge lamp and an electron energy analyzer equipped with a spin polarization detector based on spin-polarized low-energy electron diffraction. Our homemade inverse-photoemission spectrometer comprises a GaAs photocathode as spin-polarized electron source and Geiger-Mueller counters for photon detection at a fixed energy of 9.9 eV. The total energy resolution of the experiment is better than 50 meV for photoemission and better than 200 meV for inverse photoemission. The performance of our combined direct and inverse-photoemission experiment with respect to angular and energy resolutions is exemplified by the Fermi-level crossing of the Cu(111) L-gap surface state. Spin-resolved measurements of Co films on Cu(001) are used to characterize the Sherman function of the spin polarization detector as well as the spin polarization of our electron source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new advanced experimental setup for in-depth study of the interfacial reaction during reactive wetting

Reactive wetting plays a crucial role in many technical processes, from soldering in microelectronics, production of metal/ceramic composites, to hot dip galvanizing in mass production of zinc coated steel sheet. In all these cases the wetting behavior of metal melts on different surfaces plays a crucial role in material joining and coating. In all these processes the formation of the interfacial reaction layer has to occur within as short a time as possible in order to ensure a fast overall production speed. As the interfacial layer determines the stability of the formed composites, detailed knowledge of its growth mechanisms is required for a directed process optimization. However, the investigation of the processes occurring at the buried interface between substrate and wetting phase is difficult, especially for the case of liquid metal wetting metallic or ceramic solid substrates at high temperatures. Here, a novel advanced technique for the investigation of high temperature wetting processes up to a temperature of 1100 K is presented. It is based on the sessile drop technique but, in addition, allows spinning off the droplet at any chosen wetting time, thus providing direct access to the interfacial reaction layer. Since the experimental setup is integrated into a UHV compatible reaction chamber, not only excellent control of the composition of the atmosphere is ensured, but also direct transfer to surface analytical tools such as scanning electron microscope or electron spectroscopy for chemical analysis without intermediate exposure to air is realized. As will be shown for the case of hot dip galvanising of steel, this is an outstanding advance compared to existing methods.

36 MATERIALS SCIENCE↗

Ion-radical synergy in HfO{sub 2} etching studied with a XeF{sub 2}/Ar{sup +} beam setup

To gain more insight into fundamental aspects of the etching behavior of Hf-based high-k materials in plasma etch reactors, HfO{sub 2} films were etched in a multiple-beam setup consisting of a low energy Ar{sup +} ion beam and a XeF{sub 2} radical beam. The etch rate and etch products were monitored by real-time ellipsometry and mass spectrometry, respectively. Although etching of HfO{sub 2} in XeF{sub 2}/Ar{sup +} chemistry is mainly a physical effect, an unambiguous proof of the ion-radical synergistic effect for the etching of HfO{sub 2} is presented. The etch yield for 400 eV Ar{sup +} ions at a substrate temperature of 300 deg. C was 0.3 atoms/ion for Ar{sup +} sputtering and increased to 2 atoms/ion when XeF{sub 2} was also supplied. The etch yield proved to follow the common square root of ion energy dependence both for pure sputtering and radical enhanced etching, with a threshold energy at room temperature of 69{+-}17 eV for Ar{sup +} ions and 54{+-}14 eV for Ar{sup +} ions with XeF{sub 2}.

36 MATERIALS SCIENCE↗