Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

On-Sky Performance of the SPT-3G Frequency-Domain Multiplexed Readout

Frequency-domain multiplexing (fMux) is an established technique for the readout of large arrays of transition-edge sensor (TES) bolometers. Each TES in a multiplexing module has a unique AC voltage bias that is selected by a resonant filter. This scheme provides for the operation and readout of multiple bolometers on a single pair of wires, reducing thermal loading onto sub-Kelvin stages. The current receiver on the South Pole Telescope, SPT-3G, uses a 68x fMux system to operate its large-format camera of ~16,000 TES bolometers. We present here the successful implementation and performance of the SPT-3G readout as measured on-sky. Characterization of the noise reveals a median pair-differenced 1/f knee frequency of 33 mHz, indicating that low-frequency noise in the readout will not limit SPT-3G’s measurements of sky power on large angular scales. Measurements further show that the median readout white noise level in each of the SPT-3G observing bands is below the expectation for photon noise, demonstrating that SPT-3G is operating in the photon-noise-dominated regime.

47 OTHER INSTRUMENTATION↗

Multi‐Sensor Trajectory Reconstruction of the 24 April 2025 Alaska Fireball and Implications for Planetary Defense

On 24 April 2025 at 18:30:57 UTC, a bright daytime fireball over Southcentral Alaska was detected by 37 seismic stations, 16 single infrasound sensors, and four infrasound arrays, yielding 30 ballistic and multiple fragmentation arrivals. Here, the unprecedented density of seismoacoustic coverage enabled detailed reconstruction of the event using acoustic signals, with fragmentation source locations further guiding the identification of Doppler weather radar signatures of a meteorite fall. Incorporation of a radar-derived terminal point yielded a final trajectory solution, which agreed closely with an independent optical trajectory solution from video analysis. The reconstructed entry parameters from seismoacoustic analysis indicate a velocity of 25.3 km/s, an entry angle of 19°, and an energy release of ∼38 t TNT equivalent. Assuming a chondritic composition, the pre-entry object diameter was ∼0.7 m. Using orbital parameters from the optical solution, we estimate meteoroid composition as most likely an L-type ordinary chondrite. The event occurred in the sub-Arctic, where space-based optical systems face challenges in detection, demonstrating the critical role of dense ground-based seismoacoustic networks in characterizing high-latitude atmospheric entries. This uniquely well-recorded event demonstrates the capability of dense seismoacoustic networks to constrain bolide trajectories, energetics, and fragmentation, with radar and optical data providing critical confirmation and complementary perspectives. These results bridge the methodological gap between planetary-defense monitoring of natural impactors and space-traffic analyses of artificial reentries, illustrating how multi-sensor integration can deliver calibration-grade trajectories even for unpredicted events.

Fireball↗

Vector sensor-based acoustic monitoring system

An acoustic monitoring system characterizes, classifies, and geo-locates anthropogenic and natural sounds in near real time. The system includes a compact array of three acoustic vector sensors, which measures acoustic pressure and the three-dimensional particle velocity vector associated with the propagation of an acoustic wave, thereby inherently providing bearing information to an underwater source of sound. Beamforming techniques provide sound source localization, allowing for characterization of the acoustic signature of specific underwater acoustic sources.

Raghukumar, Kaustubha↗

Chip-integrated metasurface full-Stokes polarimetric imaging sensor

Abstract Polarimetric imaging has a wide range of applications for uncovering features invisible to human eyes and conventional imaging sensors. Chip-integrated, fast, cost-effective, and accurate full-Stokes polarimetric imaging sensors are highly desirable in many applications, which, however, remain elusive due to fundamental material limitations. Here we present a chip-integrated Meta surface-based Full-Stokes Polar imetric Im aging sensor (MetaPolarIm) realized by integrating an ultrathin (~600 nm) metasurface polarization filter array (MPFA) onto a visible imaging sensor with CMOS compatible fabrication processes. The MPFA is featured with broadband dielectric-metal hybrid chiral metasurfaces and double-layer nanograting polarizers. This chip-integrated polarimetric imaging sensor enables single-shot full-Stokes imaging (speed limited by the CMOS imager) with the most compact form factor, records high measurement accuracy, dual-color operation (green and red) and a field of view up to 40 degrees. MetaPolarIm holds great promise to enable transformative applications in autonomous vision, industry inspection, space exploration, medical imaging and diagnosis.

47 OTHER INSTRUMENTATION↗

Nanoconfinement and mass transport in metal–organic frameworks

The ubiquity of metal–organic frameworks in recent scientific literature underscores their highly versatile nature. MOFs have been developed for use in a wide array of applications, including: sensors, catalysis, separations, drug delivery, and electrochemical processes. Often overlooked in the discussion of MOF-based materials is the mass transport of guest molecules within the pores and channels. Given the wide distribution of pore sizes, linker functionalization, and crystal sizes, molecular diffusion within MOFs can be highly dependent on the MOF-guest system. In this paper, we discuss the major factors that govern the mass transport of molecules through MOFs at both the intracrystalline and intercrystalline scale; provide an overview of the experimental and computational methods used to measure guest diffusivity within MOFs; and highlight the relevance of mass transfer in the applications of MOFs in electrochemical systems, separations, and heterogeneous catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis and mitigation of an oscillating background on hybrid complementary metal-oxide semiconductor (hCMOS) imaging sensors at the National Ignition Facility

Nanosecond-gated hybrid complementary metal-oxide semiconductor imaging sensors are a powerful tool for temporally gated and spatially resolved measurements in high energy density science, including inertial confinement fusion, and in laser diagnostics. However, a significant oscillating background excited by photocurrent has been observed in image sequences during testing and in experiments at the National Ignition Facility (NIF). Characterization measurements and simulation results are used to explain the oscillations as the convolution of the pixel-level sensor response with a sensor-wide RLC circuit ringing. Finally, data correction techniques are discussed for NIF diagnostics, and for diagnostics where these techniques cannot be used, a proof-of-principle image correction algorithm is presented.

42 ENGINEERING↗

Utah FORGE: Well 58-32 Stimulation Conference Paper and Data

The U.S. Department of Energy’s (U.S. DOE) Frontier Observatory for Research in Geothermal Energy (FORGE) is a field laboratory that provides a unique opportunity to develop and test new technologies for characterizing, creating and sustaining Enhanced Geothermal Systems (EGS) in a controlled environment. In 2018, the U.S. DOE selected a site in south-central Utah for the FORGE laboratory. Numerous geoscientific studies have been conducted in the region since the 1970s in support of geothermal development at Roosevelt Hot Springs. A vertical scientific well, 58-32, was drilled and tested to a depth of 2290 m (7515 ft) GL in 2017 on the FORGE site to provide additional characterization of the reservoir rocks. The well encountered a conductive thermal regime and a bottom hole temperature of 199degC (390degF). More than 2000 natural fractures were identified, but measured permeabilities are low, less than 30 micro-darcies. Induced fractures indicate that the maximum horizontal stress trends NNE-SSW, consistent with geologic and well observations from the surrounding area. Approximately 45 m (147 ft) at the base of the well was left uncased. A maximum wellhead pressure of 27.6 MPa (4000 psig) at an injection rate of ~1431 L/min (~9 bpm) was measured during stimulation testing in September 2017. Conventional diagnostic evaluations of the data suggest that hydraulic fracturing and shearing occurred. Estimates of the stress gradient for delta_h_min range from of 16.7 to 17.6 kPa/m (0.74 to 0.78 psi/ft). A gradient of 25.6 kPa/m (1.13psi/ft) was calculated for delta_V. In 2019, the 2017 open-hole stimulation in well 58-32 was repeated with injection rates up to 2385 L/min (15 bpm). Two additional stimulations were conducted in the cased portion of the well; one to stimulate critically stressed fractures and the second to test noncritically stressed fractures. Breakdown of the zone spanning critically-stressed fractures occurred at a surface pressure of approximately 29.0 MPa (4200 psig). Although stimulation of the noncritically stressed fractures was interrupted by failure of the bridge plug beneath the perforated interval, micro-seismic data suggests stimulation of the fractures may have been initiated at a surface pressure of 45.5 MPa (6600 psig). These stimulation results support the conclusion the Mineral Mountains granitoid is an appropriate host for EGS development. Micro-seismicity was monitored during the stimulations using surface and downhole instrumentation. Five seismometers and a nodal array of 150 seismic sensors were deployed on the surface. A Distributed Acoustic Sensing (DAS) cable and a string of 12 geophones were deployed in well 78-32, drilled to a depth of 998 m (3274 ft) GL. A broadband sensor and a high-temperature geophone were deployed in well 68-32, drilled to a depth of 303 m (994 ft) GL. More than 420 micro-seismic events were detected by the geophone string. Other instruments detected fewer events.

15 GEOTHERMAL ENERGY↗

The EBEX Balloon-borne Experiment—Optics, Receiver, and Polarimetry

The E and B Experiment (EBEX) was a long-duration balloon-borne cosmic microwave background (CMB) polarimeter that flew over Antarctica in 2012. We describe the experiment's optical system, receiver, and polarimetric method and discuss their in-flight performance. EBEX had three frequency bands centered on 150, 250, and 410 GHz. To make effective use of limited mass and space, we created a 115 cm 2 sr high-throughput optical system that had two ambient temperature mirrors and four antireflection-coated polyethylene lenses per focal plane. All frequency bands shared the same optical train. Polarimetry was achieved with a continuously rotating achromatic half-wave plate (AHWP) that was levitated with a superconducting magnetic bearing (SMB). This is the first use of an SMB in astrophysics. Rotation stability was 0.45% over a period of 10 hr, and angular position accuracy was 0$^{°}_{.}$1. The measured modulation efficiency was above 90% for all bands. To our knowledge the 109% fractional bandwidth of the AHWP was the broadest implemented to date. The receiver, composed of one lens and the AHWP at a temperature of 4 K, the polarizing grid and other lenses at 1 K, and the two focal planes at 0.25 K, performed according to specifications, giving focal plane temperature stability with a fluctuation power spectrum that had a 1/f knee at 2 mHz. EBEX was the first balloon-borne instrument to implement technologies characteristic of modern CMB polarimeters, including high-throughput optical systems, and large arrays of transition edge sensor bolometric detectors with multiplexed readouts.

polarization↗

Topmetal CMOS direct charge sensing plane for neutrinoless double-beta decay search in high-pressure gaseous TPC

We propose a novel charge sensing concept for high-pressure Time Projection Chamber (TPC) to search for Neutrinoless Double-Beta Decay (NLDBD) with ton-scale isotope mass and beyond. A meter-sized plane, tiled with an array of CMOS integrated sensors called Topmetal that directly collect charge without gas avalanche gain, is to be deployed into a high-pressure gaseous TPC with working gases containing suitable NLDBD candidate isotopes such as Xe-136 and Se-82. The Topmetal sensor has an electronic noise <30 e- per pixel, which allows the detector to reach <1% FWHM energy resolution at the NLDBD Q-value for both Xe-136 and 82SeF6 gases by measuring ionization charges alone. The elimination of charge avalanche gain allows the direct sensing of slow-drifting ions, which enables the use of highly electronegative gas SeF6 in which free electrons do not exist. It supports the swapping of working gases without hardware modification, which is a unique way to validate signals against radioactive backgrounds. Since the sensor manufacturing and plane assembling could leverage unaltered industrial mass-production processes, stability, uniformity, scalability, and cost-effectiveness that are required for ton-scale experiments could all be reached. The strengths of TPC such as 3D ionization tracking and decay daughter tagging are retained. This development could lead to a competitive NLDBD experiment at and above ton-scale. The conceptual considerations, simulations, and initial prototyping are discussed.

Mei, Yuan↗

Hong–Ou–Mandel sensing via superradiant coupling of discrete fluorescent emitters

The Hong–Ou–Mandel (HOM) effect is a fascinating quantum phenomenon that defies classical explanation. Traditionally, remote nonlinear sources have been used to achieve coincident photons at the HOM beam splitter. Here, we suggest that the coincident emission source required for HOM interference can be created locally using superradiant near field coupled emitters positioned across the beam splitter gap. We show that sensitivity to permittivity changes in the beam splitter gap, and corresponding Fisher information can be substantially enhanced with HOM photon detection. Subsequently, we outline several strategies for integration of superradiant emitters with practical sensor systems. Taken together, these findings should pave a way for a wide array of near field HOM quantum sensors and novel quantum devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Comparison of Machine Learning Methods of Association Tested on Dense Nodal Arrays

The association of phase picks to form events is one of the fundamental components of seismology. Large and dense sensor networks, such as >1000 geophone arrays (and distributed acoustic sensing), offer unique challenges in association due to the vast numbers of observations and high likelihood of errant picks. In addition, the large number of stations can greatly increase the time it takes to perform the association. For this reason, machine learning (ML) methods might provide a more optimal method of association for such networks. In this work, we examine how well ML methods (e.g., Gaussian mixture model association, PhaseLink, and Graph Earthquake Neural Interpretation Engine) can incorporate dense seismic arrays into regional networks and how well they handle the increasing numbers of stations. Here, we test their capabilities on two dense seismic deployments, one within Rock Valley Nevada (52 nodes and a 9-station sparse local network), and the LArge-n Seismic Survey in Oklahoma dense nodal array (>1800 vertical-component geophones). Processing data from these two different styles of dense seismic deployments allows testing of how the ML algorithms can merge array data with a broader regional network, how they deal with poorly picked phases, and how they handle anthropogenic noise. We compare the ML-associated bulletins to those obtained using the Rapid Earthquake Association and Location algorithm, a more traditional method of association. We find that there are very small differences in results between the methods for small networks (<100 stations) with low pick rates. For large networks (>1000), there are enough errant picks that some of the ML methods start to create false events out of noise. We also find that the ML methods vary in computation time significantly but are all faster than the traditional method tested here.

58 GEOSCIENCES↗

Development of the microcalorimeter and anticoincidence detector for the Line Emission Mapper x-ray probe

The Line Emission Mapper (LEM) is an x-ray probe mission concept that is designed to provide unprecedented insight into the physics of galaxy formation, including stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. LEM incorporates a light-weight x-ray optic with a large-format microcalorimeter array. The LEM detector utilizes a 14k pixel array of transition-edge sensors (TESs) that will provide <2.5 eV spectral resolution over the energy range 0.2 to 2 keV, along with a field-of-view of 30 arcmin. The microcalorimeter array and readout builds upon the technology developed for the European Space Agency’s (ESA’s) Athena/x-ray Integral Field Unit. Here, we present a detailed overview of the base- line microcalorimeter design, its performance characteristics, including a detailed energy resolution budget and the expected count-rate capability. In addition, we outline the current status and plan for continued technology maturation. Behind the LEM array sits a high-efficiency TES-based anticoincidence (antico) detector that will reject cosmic-ray background events. We will briefly describe the design of the antico and plan for continued development.

47 OTHER INSTRUMENTATION↗

Developing AlMn Films for Argonne TES Fabrication

The reference design for the next-generation cosmic microwave background (CMB) experiment, CMB-S4, relies on large arrays of transition-edge sensor (TES) bolometers coupled to Superconducting Quantum Interference Device (SQUID)-based readout systems. Mapping the CMB to near cosmic variance limits will enable the search for signatures of inflation and constrain dark energy and neutrino physics. AlMn TESes provide simple film manufacturing and highly uniform arrays over large areas to meet the requirements of the CMB-S 4 experiment. TES parameters such as critical temperature and normal resistance must be tuned to experiment specifications and can be varied based on geometry and steps in the fabrication process such as deposition layering, geometry, and baking time and temperature. Using four-terminal sensing, we measured T C and R N of AlMn 2000 ppm films and devices of varying thicknesses fabricated at Argonne National Laboratory to motivate device geometries and fabrication processes to tune T C to 150–200 mK and R N to ~10 mΩ. Furthermore, measurements of IV curves and time constants for the resulting devices of varying leg length were made using time-division SQUID multiplexing and determined TC, G, k, f 3db , and RN. We present the results of these tests along with the geometries and fabrication steps used to tune the device parameters to the desired limits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advanced ACTPol TES Device Parameters and Noise Performance in Fielded Arrays

The Advanced ACTPol (AdvACT) upgrade to the Atacama Cosmology Telescope (ACT) features arrays of aluminum manganese transition-edge sensors (TESes) optimized for ground-based observations of the cosmic microwave background (CMB). Array testing shows highly responsive detectors with anticipated in-band noise performance under optical loading. We report on TES parameters measured with impedance data taken on a subset of TESes. We then compare modeled noise spectral densities to measurements. We find excess noise at frequencies around 100 Hz, nearly outside of the signal band of CMB measurements. In addition, we describe full-array noise measurements in the laboratory and in the field for two new AdvACT mid-frequency arrays, sensitive at bands centered on 90 and 150 GHz, and data for the high-frequency array (150/230 GHz) as deployed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Incubating advances in integrated photonics with emerging sensing and computational capabilities

As photonic technologies grow in multidimensional aspects, integrated photonics holds a unique position and continuously presents enormous possibilities for research communities. Applications include data centers, environmental monitoring, medical diagnosis, and highly compact communication components, with further possibilities continuously growing. Herein, we review state-of-the-art integrated photonic on-chip sensors that operate in the visible to mid-infrared wavelength region on various material platforms. Among the different materials, architectures, and technologies leading the way for on-chip sensors, we discuss the optical sensing principles that are commonly applied to biochemical and gas sensing. Our focus is on passive optical waveguides, including dispersion-engineered metamaterial-based structures, which are essential for enhancing the interaction between light and analytes in chip-scale sensors. We harness a diverse array of cutting-edge sensing technologies, heralding a revolutionary on-chip sensing paradigm. Our arsenal includes refractive-index-based sensing, plasmonics, and spectroscopy, which forge an unparalleled foundation for innovation and precision. Furthermore, we include a brief discussion of recent trends and computational concepts, incorporating Artificial Intelligence & Machine Learning (AI/ML) and deep learning approaches over the past few years to improve the qualitative and quantitative analysis of sensor measurements.

Jain, Sourabh (ORCID:0000000279923275)↗

Parallelized telecom quantum networking with an ytterbium-171 atom array

The integration of quantum computers and sensors into a quantum network enables new capabilities in quantum information science. Most networks with atom-like qubits operate at visible or near-ultraviolet wavelengths and require conversion to the telecom band for long-distance communication, which reduces efficiency and potentially introduces noise. In this article we report high-fidelity entanglement between ytterbium-171 atoms and optical photons generated directly in the telecommunication band, where fibre loss is low. The nuclear spin of the atom is entangled with a single photon in the time-bin basis, yielding a high atom-measurement-corrected atom–photon Bell state fidelity. This can be further improved by addressing photon measurement errors. By imaging the atom array onto an optical fibre array, we also implement a parallelized networking protocol that can increase the remote entanglement rate proportionately with the number of channels. We also preserve coherence on a memory qubit during operations on communication qubits. These results support the integration of atomic systems into scalable quantum networks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Material and Design Optimization of Printed Melt Wire Arrays

Recent work conducted by the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory resulted in the establishment of in-house capabilities for fabricating and testing new advanced manufactured sensors for measuring irradiation temperatures inside a nuclear test reactor. Though current methods of real-time temperature monitoring (e.g., thermocouples) can still be used, the complexity of the feedthroughs and attachments needed for collecting real time measurements greatly increases the experiment-related costs. On the other hand, passive monitoring techniques can be used for collecting post irradiation temperature measurements by inferring reactor temperatures, based on the melting points of well-characterized materials (i.e., standard melt wires). However, challenges have arisen due to the limited space available for including instrumentation in experiments. To resolve this issue, the ASI program expanded its temperature detection capabilities to include advance manufactured melt wires for post-irradiation temperature measurements. These melt wires can determine reactor temperatures while also accommodating space limitations in irradiation experiments. To improve performance reliability and enhance melt wire readability following irradiation, FY-22 efforts have focused on optimizing the materials used in the encapsulation and printed melt wire array. This report details the design and fabrication tasks, along with the subsequent x ray computed tomography (XCT) evaluation process. The melt wire array consisted of indium with a melting point of 157°C, indium/silver (96/4 at%) with a melting point of 219°C, and tin with a melting point of 230°C. The encapsulation disc was made of vanadium due to its low activation properties and radiation resistance when deployed in nuclear reactors. Additionally, the melt wire design consisted of a ceramic sublayer (alumina disc) to further enhance the XCT post melting images of the printed melt wires. However, when sealing the vanadium container, all three melt wires melted, reflecting the temperature limitations that must be considered when employing metal containers in the sealing process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CCAT-prime: Designs and status of the first light 280 GHz MKID array and mod-cam receiver

The CCAT-prime project's first light array will be deployed in Mod-Cam, a single-module testbed and first light cryostat, on the Fred Young Submillimeter Telescope (FYST) in Chile's high Atacama desert in late 2022. FYST is a six-meter aperture telescope being built on Cerro Chajnantor at an elevation of 5600 meters to observe at millimeter and submillimeter wavelengths. 1 Mod-Cam will pave the way for Prime-Cam, the primary first generation instrument, which will house up to seven instrument modules to simultaneously observe the sky and study a diverse set of science goals from monitoring protostars to probing distant galaxy clusters and characterizing the cosmic microwave background (CMB). At least one feedhorn-coupled array of microwave kinetic inductance detectors (MKIDs) centered on 280 GHz will be included in Mod-Cam at first light, with additional instrument modules to be deployed along with Prime-Cam in stages. The first 280 GHz detector array was fabricated by the Quantum Sensors Group at NIST in Boulder, CO and includes 3,456 polarization- sensitive MKIDs. Current mechanical designs allow for up to three hexagonal arrays to be placed in each single instrument module. We present details on this first light detector array, including mechanical designs and cold readout plans, as well as introducing Mod-Cam as both a testbed and predecessor to Prime-Cam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗