Wilson Corners Solid Waste Management Unit (SWMU) 001: 2021 Annual Long-Term Monitoring Report, Kennedy Space Center, Florida

This report presents a summary of the long-term monitoring (LTM) activities that occurred in 2021 at Wilson Corners, Solid Waste Management Unit (SWMU) 001, at Kennedy Space Center (KSC), Florida. The site is monitored under KSC’s Resource Conservation and Recovery Act (RCRA) Corrective Action Program. Adaptive site management is being utilized through ongoing assessment, design, and interim measures (IM). Annual LTM of the groundwater is also being conducted at the site. This approach also meets the requirements of Chapter 62-780, Florida Administrative Code (F.A.C.). The goal of LTM at this site is threefold: to determine groundwater flow characteristics, monitor the downgradient concentration trends, and monitor select locations internal to the groundwater plume. Every 5 years, upgradient and side-gradient monitoring wells are sampled to verify delineation. The last time this was performed was in 2015. The sampling of these wells in 2020 was replaced with the direct push technology (DPT) investigations completed in October 2020 and April 2021. This DPT groundwater data was presented in an Advance Data Package (ADP) in September 2021 and discussed in the Implementation Work Plan (IWP) dated November 2021 for installation of an air sparge (AS) system. Based on results from groundwater sampling activities performed during the previous reporting period, including the 2020 and 2021 DPT groundwater sampling, it was determined that the LTM sampling plan was no longer meeting the goal of LTM because delineation was not verified. The 2021 LTM sampling plan was modified to include the sampling of monitoring wells located around the perimeter of the low concentration plume (LCP); the area with concentrations of contaminants of concern [COCs] greater than Groundwater Cleanup Target Levels [GCTLs]), and sampling of 10 monitoring wells proposed for installation (April 2021 KSC Remediation Team (KSCRT) Meeting, Decision 2104-D32). The modified LTM plan received team consensus at the September 2021 KSCRT Meeting (Decision Number 2109-D03), and sampling of the existing monitoring wells was completed in December 2021. The proposed monitoring wells are planned for installation in late 2022, concurrent with ongoing IM construction activities. December 2021 LTM data was presented at the May 2022 KSCRT Meeting, and activities are summarized in this report. The activities presented in this report include the December 2021 groundwater gauging of 42 monitoring wells and sampling of 44 monitoring wells. During the December 2021 event, the low flow sampling method was used, and samples were analyzed for a select list of volatile organic compounds (VOCs), including 1,1,2-trichloro-1,2,2-trifluoroethane (Freon 113). The following conclusions can be made based on the 2021 LTM results: - In December 2021, groundwater flow for the site was generally to the west at all intervals. This is generally consistent with historical observations at the site, with the exception of a southwest and southeast flow component observed at 34 to 48 feet below land surface (bls). - The vertical extent of VOCs was historically delineated by monitoring wells screened greater than 48 feet bls. The results from the two vertical extent monitoring wells, WILC-MW0078 (screened 65 to 70 feet bls) and WILC-MW0130 (screened 56 to 66 feet bls) that were sampled during the 2021 LTM indicate that groundwater vinyl chloride (VC) concentrations in both wells were greater than the GCTL. The Remediation Team has previously agreed to delay deeper DPT investigations in this area to prevent the creation of additional pathways for vertical migration. - The LCP continues to extend both horizontally, predominantly to the west, and vertically beyond the current monitoring well network, with some retraction observed to the southeast. Evaluation of this data combined with data from the 2020 and 2021 DPT sampling event indicate that the LCP encompasses an estimated 20.7 acres based on an expanded sampling area, as compared to the 2020 LCP footprint of 17.0 acres. - Freon 113 was not detected above GCTLs during the 2021 LTM event. Based on groundwater sampling activities performed in 2021, including April 2021 DPT groundwater sampling, the following recommendations are provided: - Perform the next LTM sampling event, targeted to occur in 2023, concurrently with the IM baseline sampling prior to AS system installation; - Include sampling from nine monitoring wells that are planned to be installed in late 2022, concurrent with upcoming IM construction activities. Installation of one deep vertical well, screened 70 to 80 feet bls, will be delayed to prevent the creation of an additional pathway for vertical migration; - Continue to sample under the modified annual LTM plan as presented in Table 4-1 concurrently with IM baseline sampling; and - Once the AS system install and start-up is complete, select monitoring wells from the LTM program will transition into the performance monitoring plan, and LTM will be temporarily discontinued. Performance monitoring will be performed quarterly, and the monitoring well network will be evaluated following the first performance monitoring sampling event.

long-term monitoring (LTM)↗

Wilson Corners, Solid Waste Management Unit 001(SWMU 01) 2023 Annual Long-Term Monitoring Report

This report presents a summary of the long-term monitoring (LTM) activities that occurred in 2023 at Wilson Corners, Solid Waste Management Unit 001, at Kennedy Space Center (KSC), Florida. Annual LTM of groundwater is being conducted at the site. Based on results from groundwater sampling activities performed during the 2019 through 2020 LTM reporting period and the 2020 and 2021 DPT groundwater sampling, it was determined that the LTM sampling plan was no longer meeting the goal of LTM because delineation was not verified and the installation of an air sparge (AS) system to treat the area of the High Concentration Plume was recommended. The AS System was installed in late 2022 and early 2023. System start-up activities were initiated in April 2023. Following system startup, several site wells required retrofitting to equip wellheads for withstanding the air pressure released from air sparge wells during system operation. Some site wells also required repair or abandonment, and replacement. Survey of location and top-of-casing of newly installed monitoring wells was combined with scheduled AS system survey activities and was completed in January 2024. The activities presented in this report include the February and April 2023 LTM monitoring well installations; March and April 2023 LTM and performance monitoring well water level gauging and sampling; November 2023 LTM well retrofits and repairs; a summary of December 2023 LTM well abandonments and installations (complete site well abandonment activities will be presented under a separate cover); and January 2024 LTM well survey. During the March and April 2023 sampling events, the low-flow sampling method was used, and samples were analyzed for a select list of volatile organic compounds. In March 2023, groundwater flow for the site was generally to the west was generally consistent with historical observations at the site. The Low Concentration Plume (LCP) continues to extend both horizontally and vertically beyond the terminal depth of the current monitoring well network. Data, inclusive of the 2023 LTM and baseline performance monitoring sampling events, indicate that the LCP encompasses an estimated 19.5 acres, compared to the 2021 LCP footprint, inclusive of the 2020 and 2021 DPT sampling events of 20.7 acres. The vertical extent of VOCs was historically delineated by monitoring wells screened greater than 48 feet below land surface (bls). The results from the three vertical extent monitoring wells screened below 48 feet bls that were sampled during the 2023 LTM indicate that groundwater vinyl chloride concentrations in these three wells are greater than the GCTL. As presented in the 2021 Long-Term Monitoring Report (NASA 2022), the KSCRT agreed to delay deeper investigations in this area to prevent the creation of additional pathways for vertical migration. Based on groundwater sampling activities performed in 2023, recommendations are to perform the next annual LTM sampling event, scheduled for April 2024 and to conduct quarterly performance monitoring of the AS System. The current selection of monitoring wells in the recommended 2024 LTM plan will provide an adequate data set for monitoring groundwater plume behavior; however, the LTM monitoring well network will be evaluated and refined based on 2024 LTM and year one performance monitoring data.

King Linnea↗

Apparatus and methods for sample analysis with multi-gradient microfluidics

A device for analyzing biological samples comprises first, second, third, and fourth layers. The first layer comprises a sample chamber in which a sample is positioned. The second layer comprises first, second, and third channels. A third, porous layer is positioned between the first layer and the second layer. A fourth layer composed of a substantially liquid-impermeable material is positioned between the second layer and the third layer. The fourth layer includes first and second pass-through channels that are aligned with the first and second channel, respectively. Fluids that flow in the first and second channels pass through the pass-through channels and diffuse into the sample chamber, establishing a chemical concentration gradient therein. A gas in the sample chamber can diffuse through the third and fourth layers and interact with a fluid flowing in the third channel, establishing a gas concentration gradient in the sample chamber.

Kim, Peter Wonhee↗

Rock sampling

A method for sampling rock and other brittle materials and for controlling resultant particle sizes is described. The method involves cutting grooves in the rock surface to provide a grouping of parallel ridges and subsequently machining the ridges to provide a powder specimen. The machining step may comprise milling, drilling, lathe cutting or the like; but a planing step is advantageous. Control of the particle size distribution is effected primarily by changing the height and width of these ridges. This control exceeds that obtainable by conventional grinding.

Blum, P.↗

High Throughput Mode Liquid Microjunction Surface Sampling Probe

A simple and automated spot sampling operation mode for a liquid microjunction surface sampling probe/electrospray ionization mass spectrometry (LMJ-SSP/ESI-MS) system is reported. Prior manual and automated spot sampling methods with this probe relied on a careful, relatively slow alignment of the probe and surface distance (< 20 m spacing) to form the probe - to - surface liquid microjunction critical to successful surface sampling. Moreover, sampling multiple spots required retraction of the surface from the probe and a repeat of this careful probe - to - surface distance alignment at the next sampling position. With the method described here, the probe was not positioned as close to the surface, the exact probe - to - surface positioning was found to be less critical (spanning distances from about 100 300 m), and this distance was not altered during the sampling of an entire array of sample spots. With the probe positioned within the appropriate distance from the surface, the liquid microjunction was formed by letting the liquid from the sampling end of the probe extend out from the probe to the surface. This was accomplished by reducing the self-aspiration liquid flow rate of the probe to a value less than the volume flow rate pumped into the probe. When the self-aspiration rate of the probe was subsequently increased, analytes on the surface that dissolved at the liquid microjunction were aspirated back into the probe with the liquid that created the liquid microjunction and electrosprayed. Presented here are the basics of this new sampling mode, as well as data that illustrate the potential analytical capabilities of the device to conduct high-throughput quantitative analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Subtask 4.27 - Evaluation of the Multielement Sorbent Trap (MEST) Method at an Illinois Coal-Fired Plant

Owners of fossil fuel-fired power plants face the challenge of measuring stack emissions of trace metals and acid gases at much lower levels than in the past as a result of increasingly stringent regulations. In the United States, the current reference methods for trace metals and halogens are wet-chemistry methods, U.S. Environmental Protection Agency (EPA) Methods 29 and 26 or 26A, respectively. As a possible alternative to the EPA methods, the Energy & Environmental Research Center (EERC) has developed a novel multielement sorbent trap (MEST) method to be used to sample for trace elements and/or halogens. Sorbent traps offer a potentially advantageous alternative to the existing sampling methods, as they are simpler to use and do not require expensive, breakable glassware or handling and shipping of hazardous reagents. Field tests comparing two sorbent trap applications (MEST-H for hydrochloric acid and MEST-M for trace metals) with the reference methods were conducted at two power plant units fueled by Illinois Basin bituminous coal. For hydrochloric acid, MEST measured concentrations comparable to EPA Method 26A at two power plant units, one with and one without a wet flue gas desulfurization scrubber. MEST-H provided lower detection limits for hydrochloric acid than the reference method. Results from a dry stack unit had better comparability between methods than results from a wet stack unit. This result was attributed to the very low emissions in the latter unit, as well as the difficulty of sampling in a saturated flue gas. Based on these results, the MEST-H sorbent traps appear to be a good candidate to serve as an alternative to Method 26A (or 26). For metals, the MEST trap gave lower detection limits compared to EPA Method 29 and produced comparable data for antimony, arsenic, beryllium, cobalt, manganese, selenium, and mercury for most test runs. However, the sorbent material produced elevated blanks for cadmium, nickel, lead, and chromium at levels that would interfere with accurate measurement at U.S. hazardous air pollutant emission limits for existing coal-fired power plant units. Longer sampling times employed during this test program did appear to improve comparative results for these metals. Although the sorbent contribution to the sample was reduced through improved trap design, additional research is still needed to explore lower-background materials before the MEST-M application can be considered as a potential alternative method for all of the trace metals. This subtask was funded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FC26-08NT43291. Nonfederal funding was provided by the Electric Power Research Institute, the Illinois Clean Coal Institute, Southern Illinois Power Company, and the Center for Air Toxic Metals Affiliates Program.

Pavlish, John↗

Cleanroom Contamination Identification Method Development

During fabrication, assembly, and testing of spacecraft and flight hardware it is vital to avoid contaminants that can cause degradation and could result in significant failure. Yet, there is no existing contamination monitoring method that provides the identity of airborne particles in a cleanroom facility. Knowing the particle identities, would allow scientists and engineers to determine the source of the contaminants and prevent setbacks before they occur or cause damage. Current cleanliness monitoring methods include airborne particle counters (APCs), fallout filters, and visual inspections. Particle counts from APCs are the primary metric used to define a cleanroom class and hence its level of cleanliness, but do not provide identification nor can they differentiate between large and small sizes of particles. In addition, using fallout filters is not a proactive, timely, or representative approach to cleanroom contamination monitoring because these samples are only retrieved after 30 days and are placed away from spacecraft processing to avoid interference with operations. In contrast, the forced air sampling method can collect a sample within an hour at any location required and provide results in less than a day. This system uses a cassette and filter sample medium to capture airborne particles which are then taken to a scanning electron microscope with energy dispersive spectroscopy (SEM/EDS) to identify and size the captured particles. Development of forced air sampling into an established laboratory capability will allow for fast sampling and routine identification of unknown contamination sources within the cleanroom. The test method development required market research for an air sampling cassette that increases sample collection efficiency and a filter with low enough background contamination to allow differentiation between a blank (control) and the collected sample. It was determined that a conductive black cassette and a polycarbonate filter were the best options. Conductive black cassettes, in comparison to the standard styrene, are manufactured using polypropylene filled with carbon. This makes the cassette conductive and minimizes the tendency of particles to stick to the wall of the cassette due to electrostatic force. In previous trials a mixed cellulose ester (MCE) filter was used to capture the contaminants, however the rougher surface of the filter contributed to entrapment of the particles within the filter structure and made it harder to identify the particles. In comparison, track etched polycarbonate filters have random cylindrical pores and a smooth surface which contributes to uniform sample distribution on the surface of the filter. Future work includes: testing the system using control samples to determine the efficiency and suitability of the medium, performing sample collection in various environments to establish ideal operating parameters and analyzing contaminant particles using SEM/EDS and assistant characterization techniques. Once fully developed, employing the forced air sampling method will help to prevent damage to spacecraft, avoid schedule delays, and allow for mission success.

Hernandez Melendez, Jailyn M.↗

The Effect of Synthetic Method and Annealing Temperature on Metal Site Preference in Al 1-x Ga x FeO 3

Magnetoelectric materials couple both magnetic and electronic properties, making them attractive for use in multifunctional devices. The magnetoelectric AFeO 3 compounds (Pna2 1 ; A = Al, Ga) have received attention as the properties of the system depend on composition as well as the synthetic method used. Al 1–x Ga x FeO 3 (0 ≤ x ≤ 1) was synthesized by the sol–gel and coprecipitation methods and studied by X-ray absorption near-edge spectroscopy (XANES). Al L 2,3⁻ , Ga K-, and Fe K-edge XANES spectra were collected to examine how the average metal coordination number (CN) changes with the synthetic method. Al and Fe were found to prefer octahedral sites, while Ga prefers the tetrahedral site. It was found that composition played a larger role in determining site occupancies than synthetic method. Samples made by the sol–gel or ceramic methods (reported previously; Walker, J. D. S.; Grosvenor, A. P. J. Solid State Chem. 2013, 197, 147–153) showed smaller spectral changes than samples made via the coprecipitation method. This is attributed to greater ion mobility in samples synthesized via coprecipitation as the reactants do not have a long-range polymeric or oxide network during synthesis like samples synthesized via the sol–gel or ceramic method. Increasing annealing temperature increases the average coordination number of Al, and to a lesser extent Ga, while the average coordination number of Fe decreases. This study indicates that greater disorder is observed when the Al 1–x Ga x FeO 3 compounds have high Al content, and when annealed at higher temperatures.

Walker, James D.S.↗

Convenient mounting method for electrical measurements of thin samples

A method for mounting thin samples for electrical measurements is described. The technique is based on a vacuum chuck concept in which the vacuum chuck simultaneously holds the sample and established electrical contact. The mounting plate is composed of a glass-ceramic insulating material and the surfaces of the plate and vacuum chuck are polished. The operation of the vacuum chuck is examined. The contacts on the sample and mounting plate, which are sputter-deposited through metal masks, are analyzed. The mounting method was utilized for van der Pauw measurements.

Matus, L. G.↗

Calculating uncertainty on K-effective with MONK10 - 14583

Criticality safety assessments require a demonstration that a particular configuration of fissile material has an adequate sub-critical margin (k-effective sufficiently below unity) to ensure that the risk of criticality under normal operation and accident conditions is acceptable. The required sub-critical margin depends upon the uncertainty in the estimated value of k-effective. The uncertainty in the calculated value of k-effective arises from a number of sources, including: manufacturing tolerances on input data to the code (affecting geometry, compositions and densities), uncertainty in the nuclear data used by the code, stochastic uncertainty resulting from Monte Carlo simulation and modelling approximations/errors, including the inevitable bugs in the software. The ANSWERS Software Service, in collaboration with industrial partners, is developing a number of techniques to better understand and quantify uncertainty on predicted values of k-effective, using MONK. The SPRUCE utility code has been developed to allow uncertainty to be estimated using sampling methods. This can include the sampling of input parameters (including dimensions, compositions and densities) from statistical distributions. It can also include sampling different nuclear data libraries. A set of nuclear data libraries has been generated for this purpose by sampling from statistical distributions that represent the uncertainties in the published nuclear data evaluated files; a set of libraries has been produced for Latin Hypercube Sampling. By varying the input data and nuclear data, separate and combined uncertainties due to manufacturing tolerances and nuclear data can be derived. By performing least squares fitting on the results it is also possible to estimate the contribution of each of the uncertain inputs and a sensitivity method in MONK can break down the nuclear data uncertainty. (authors)

42 ENGINEERING↗

nautilus : boosting Bayesian importance nested sampling with deep learning

ABSTRACT We introduce a novel approach to boost the efficiency of the importance nested sampling (INS) technique for Bayesian posterior and evidence estimation using deep learning. Unlike rejection-based sampling methods such as vanilla nested sampling (NS) or Markov chain Monte Carlo (MCMC) algorithms, importance sampling techniques can use all likelihood evaluations for posterior and evidence estimation. However, for efficient importance sampling, one needs proposal distributions that closely mimic the posterior distributions. We show how to combine INS with deep learning via neural network regression to accomplish this task. We also introduce nautilus, a reference open-source python implementation of this technique for Bayesian posterior and evidence estimation. We compare nautilus against popular NS and MCMC packages, including emcee, dynesty, ultranest, and pocomc, on a variety of challenging synthetic problems and real-world applications in exoplanet detection, galaxy SED fitting and cosmology. In all applications, the sampling efficiency of nautilus is substantially higher than that of all other samplers, often by more than an order of magnitude. Simultaneously, nautilus delivers highly accurate results and needs fewer likelihood evaluations than all other samplers tested. We also show that nautilus has good scaling with the dimensionality of the likelihood and is easily parallelizable to many CPUs.

97 MATHEMATICS AND COMPUTING↗

A Two-Step Approach to Uncertainty Quantification of Core Simulators

For the multiple sources of error introduced into the standard computational regime for simulating reactor cores, rigorous uncertainty analysis methods are available primarily to quantify the effects of cross section uncertainties. Two methods for propagating cross section uncertainties through core simulators are the XSUSA statistical approach and the “two-step” method. The XSUSA approach, which is based on the SUSA code package, is fundamentally a stochastic sampling method. Alternatively, the two-step method utilizes generalized perturbation theory in the first step and stochastic sampling in the second step. The consistency of these two methods in quantifying uncertainties in the multiplication factor and in the core power distribution was examined in the framework of phase I-3 of the OECD Uncertainty Analysis in Modeling benchmark. With the Three Mile Island Unit 1 core as a base model for analysis, the XSUSA and two-step methods were applied with certain limitations, and the results were compared to those produced by other stochastic sampling-based codes. Based on the uncertainty analysis results, conclusions were drawn as to the method that is currently more viable for computing uncertainties in burnup and transient calculations.

Yankov, Artem↗

Uncertainty quantification for evaluating the impacts of fracture zone on pressure build-up and ground surface uplift during geological CO₂ sequestration

A series of numerical test cases reflecting broad and realistic ranges of geological formation and preexisting fault properties was developed to systematically evaluate the impacts of preexisting faults on pressure buildup and ground surface uplift during CO₂ injection. Numerical test cases were conducted using a coupled hydro-geomechanical simulator, eSTOMP (extreme-scale Subsurface Transport over Multiple Phases). For efficient sensitivity analysis and reliable construction of a reduced-order model, a quasi-Monte Carlo sampling method was applied to effectively sample a high-dimensional input parameter space to explore uncertainties associated with hydrologic, geologic, and geomechanical properties. The uncertainty quantification results show that the impacts on geomechanical response from the pre-existing faults mainly depend on reservoir and fault permeability. When the fault permeability is two to three orders of magnitude smaller than the reservoir permeability, the fault can be considered as an impermeable block that resists fluid transport in the reservoir, which causes pressure increase near the fault. When the fault permeability is close to the reservoir permeability, or higher than 10⁻¹⁵ m² in this study, the fault can be considered as a conduit that penetrates the caprock, connecting the fluid flow between the reservoir and the upper rock.

CO₂ geological sequestration↗

Electric field detection of coherent synchrotron radiation in a storage ring generated using laser bunch slicing

The electric field of coherent synchrotron radiation (CSR) generated by laser bunch slicing in a storage ring has been detected by an electro-optic sampling method. The gate pulses for sampling are sent through a large-mode-area photonic-crystal fiber. The observed electric field profile of the CSR is in good agreement with the spectrum of the CSR observed using Fourier transform far-infrared spectrometry, indicating good phase stability in the CSR. The longitudinal density profiles of electrons modulated by laser pulses were evaluated from the electric field profile.

43 PARTICLE ACCELERATORS↗