Thermal neutron filter design for the neutron radiography facility at the LVR-15 reactor

In 2011 a decision was made to build a neutron radiography facility at one of the unused horizontal channels of the LVR-15 research reactor in Rez, Czech Republic. One of the key conditions for operating an effective radiography facility is the delivery of a high intensity, homogeneous and collimated thermal neutron beam at the sample location. Additionally the intensity of fast neutrons has to be kept as low as possible as the fast neutrons may damage the detectors used for neutron imaging. As the spectrum in the empty horizontal channel roughly copies the spectrum in the reactor core, which has a high ratio of fast neutrons, neutron filter components have to be installed inside the channel in order to achieve desired beam parameters. As the channel design does not allow the instalment of complex filters and collimators, an optimal solution represent neutron filters made of large single-crystal ingots of proper material composition. Single-crystal silicon was chosen as a favorable filter material for its wide availability in sufficient dimensions. Besides its ability to reasonably lower the ratio of fast neutrons while still keeping high intensities of thermal neutrons, due to its large dimensions, it suits as a shielding against gamma radiation from the reactor core. For designing the necessary filter dimensions the Monte-Carlo MCNP transport code was used. As the code does not provide neutron cross-section libraries for thermal neutron transport through single-crystalline silicon, these had to be created by approximating the theory of thermal neutron scattering and modifying the original cross-section data which are provided with the code. Carrying out a series of calculations the filter thickness of 1 m proved good for gaining a beam with desired parameters and a low gamma background. After mounting the filter inside the channel several measurements of the neutron field were realized at the beam exit. The results have justified the expected calculated values. After the successful filter installing and a series of measurements, first test neutron radiography attempts with test samples could been carried out. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improving public communication through environmental data transparency at Los Alamos National Laboratory - 15306

The Los Alamos National Laboratory (LANL) environmental data span a wide range of media, including air, soil, sediment, water, foodstuff, and biota as well as over 1000 analytes and time periods extending over 4 decades, resulting in over 14 million records to manage and analyze. At a time of budget cuts and rapid social and technological change, the public, regulatory and compliance agencies, and stakeholders demand accelerated data delivery and efficiency, information sharing, and transparency in the dissemination and handling of samples collected in and around LANL. Meeting these requirements, while constraining the associated costs can be challenging; however, LANL has achieved this by adopting a cloud-based database called the Environmental Information Management (EIM) system and its public database counterpart, IntellusNM (Intellus) (www.intellusnm.com). To be consistent with federal initiatives to move government computing into cloud-based services, LANL chose to partner with an existing cloud-based vendor, Locus Technologies, to implement a software-as-a-service model. As an additional cost-saving measure, local regulatory and compliance agencies collaborated with LANL to incorporate their data into EIM and Intellus database. By adopting a single platform cloud-based solution to replace 12 different pre-existing environmental data systems, LANL has streamlined environmental data processes, resulting in over $15 million cost savings through 2015. EIM, LANL's internal cloud database, provides a cradle-to-grave process for data handling. EIM supports LANL's entire data process from detailed sample planning, mobile data collection using iOS mobile devices, to automated bottle labeling, generation of chain of custody, analytical lab electronic data deliverable upload, auto data validation, sample tracking, and custom regulatory and compliance reports. EIM has functionality to assess data in various ways such as the ability to design new formatted reports, a free-form structured query language tool of the entire database, exceedance reports, calculation engine, charting, trends, and statistics. EIM also has interactive geographic information system layers and analyte concentration color contour mapping capabilities. Additionally, and of greater importance to LANL, EIM supports the ability for third-party landowners to review data before release to the public, thus ensuring transparency and confidence in LANL's stewardship of human health and the environment. Intellus, the database counterpart of EIM, is the publicly available view of the entire LANL database and requires no data feeds or transformations. Intellus allows user-friendly access to LANL's environmental data as it is collected, providing the public, scientists, remediation teams, regulators, and stakeholders within hours of receipt. Full transparency in giving the public access to environmental data information provides LANL's overall solution to environmental data management for the public. By making the data easy to obtain, search, and query for interested stakeholders, the system enables confidence in LANL's stewardship of the environment. Working together identifies key topics of improvements, develop strategies and help support innovation and substantial advances within LANL's environmental data management system. (authors)

54 ENVIRONMENTAL SCIENCES↗

Body burdens of brominated flame retardants and other persistent organo-halogenated compounds and their descriptors in US girls

Background: Levels of brominated flame retardants are increasing in US populations, yet little data are available on body burdens of these and other persistent hormonally active agents (HAAs) in school-aged children. Exposures to such chemicals may affect a number of health outcomes related to development and reproductive function. Objective: Determine the distribution of biomarkers of polybrominated diphenyl ethers (PBDEs), polychlorinated biphenyls (PCBs), and organo-chlorinated pesticides (OCPs), such as DDT/DDE, in children, and their variation by key descriptor variables. Methods: Ethnically diverse cohorts of girls 6-8 y old at baseline are being followed for growth and pubertal development in a multi-site, longitudinal study. Nearly 600 serum samples from the California and Ohio sites were analyzed for lipids, 35 PCB congeners, 11 PBDE congeners, and 9 OCPs. The biomarker distributions were examined and geometric means compared for selected analytes across categories of age, race, site, body mass index (BMI), parental education, maternal age at delivery, and breast feeding in adjusted models. Results: Six PBDE congeners were detected among greater than 70% of samples, with BDE-47 having the highest concentration (median 42.2, range 4.9-855 ng/g lipid). Girls in California had adjusted geometric mean (GM) PBDE levels significantly higher than girls in Ohio. Furthermore, Blacks had significantly higher adjusted GMs of all six PBDE congeners than Whites, and Hispanics had intermediate values. GMs tended to be lower among more obese girls, while other variables were not strongly associated. In contrast, GMs of the six PCB congeners most frequently detected were significantly lower among Blacks and Hispanics than Whites. PCBs and the three pesticides most frequently detected were also consistently lower among girls with high BMI, who were not breast-fed, whose mothers were younger, or whose care-givers (usually parents) were less educated. Girls in California had higher GMs than in Ohio for the pesticides and most PCB congeners, but the opposite for CB-99 and -118. Conclusions: Several of these potential HAAs were detected in nearly all of these young girls, some at relatively high levels, with variation by geographic location and other demographic factors that may reflect exposure pathways. The higher PBDE levels in California likely reflect differences in fire regulation and safety codes, with potential policy implications.

60 APPLIED LIFE SCIENCES↗

SU-F-E-09: Respiratory Signal Prediction Based On Multi-Layer Perceptron Neural Network Using Adjustable Training Samples

Purpose: Dynamic tracking of moving organs, such as lung and liver tumors, under radiation therapy requires prediction of organ motions prior to delivery. The shift of moving organ may change a lot due to huge transform of respiration at different periods. This study aims to reduce the influence of that changes using adjustable training signals and multi-layer perceptron neural network (ASMLP). Methods: Respiratory signals obtained using a Real-time Position Management(RPM) device were used for this study. The ASMLP uses two multi-layer perceptron neural networks(MLPs) to infer respiration position alternately and the training sample will be updated with time. Firstly, a Savitzky-Golay finite impulse response smoothing filter was established to smooth the respiratory signal. Secondly, two same MLPs were developed to estimate respiratory position from its previous positions separately. Weights and thresholds were updated to minimize network errors according to Leverberg-Marquart optimization algorithm through backward propagation method. Finally, MLP 1 was used to predict 120∼150s respiration position using 0∼120s training signals. At the same time, MLP 2 was trained using 30∼150s training signals. Then MLP is used to predict 150∼180s training signals according to 30∼150s training signals. The respiration position is predicted as this way until it was finished. Results: In this experiment, the two methods were used to predict 2.5 minute respiratory signals. For predicting 1s ahead of response time, correlation coefficient was improved from 0.8250(MLP method) to 0.8856(ASMLP method). Besides, a 30% improvement of mean absolute error between MLP(0.1798 on average) and ASMLP(0.1267 on average) was achieved. For predicting 2s ahead of response time, correlation coefficient was improved from 0.61415 to 0.7098.Mean absolute error of MLP method(0.3111 on average) was reduced by 35% using ASMLP method(0.2020 on average). Conclusion: The preliminary results demonstrate that the ASMLP respiratory prediction method is more accurate than MLP method and can improve the respiration forecast accuracy.

60 APPLIED LIFE SCIENCES↗

Characterizing Industrial Catalysts using in situ XAFS under Identical Conditions

In situ X-ray absorption spectroscopy (XAS) in catalysis research has traditionally been conducted by making one measurement at a time on a single sample. In an industrial research environment this is especially limiting as sample throughput (productivity) and turnaround time (direct project relevance) are critical issues in the use of XAS in a fast-moving technology delivery project. In order to address these issues we have developed and implemented a four-channel ionization chamber combined with two different in situcells that allows XAS data to be collected simultaneously from four samples, or four regions, in transmission geometry without any sample or detector movement. In the development of this new capability it was realized that there are other benefits from this simultaneous detection in addition to increased productivity. Namely, (i) the use of EXAFS to determine the structure of a catalystin situ axially at four different positions down a catalyst bed; (ii) the ability to collect up to four XAFS spectra simultaneously and thereby avoid any scan-to-scan uncertainties, and (iii) the added confidence in the ability to discriminate small differences in similarly prepared catalysts which is typical in the development of a commercial catalyst. Specific illustrations of each of these applications are shown. The methodology is simple to implement and could be used on any XAFS beamline with a horizontal fan of radiation, such as at a typical bending magnet or wiggler source beamline.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monte Carlo study for optimal conditions in single-shot imaging with femtosecond x-ray laser pulses

Intense x-ray pulses from x-ray free electron lasers (XFELs) enable the unveiling of atomic structure in material and biological specimens via ultrafast single-shot exposures. As the radiation is intense enough to destroy the sample, a new sample must be provided for each x-ray pulse. These single-particle delivery schemes require careful optimization, though systematic study to find such optimal conditions is still lacking. We have investigated two major single-particle delivery methods: particle injection as flying objects and membrane-mount as fixed targets. The optimal experimental parameters were searched for via Monte Carlo simulations to discover that the maximum single-particle hit rate achievable is close to 40%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-throughput small-angle X-ray scattering reveals effective structure factor transitions linked to high-concentration antibody viscosity

High-concentration monoclonal antibody (mAb) formulations are often constrained by elevated viscosity, largely driven by protein–protein interactions, which complicates manufacturing and limits subcutaneous delivery. Early viscosity risk assessment is essential during discovery, yet traditional measurements require large sample volumes, and lack high-throughput capability. Here, we develop a high-throughput small-angle X-ray scattering (SAXS) protocol to detect mAb self-association at dilute concentrations, enabling early predictive insights into high-concentration viscosity. Synchrotron SAXS measurements were conducted for 21 mAbs formulated in a histidine buffer at pH 6.0. An initial subset of 10 mAbs analyzed across 1–150 mg/mL revealed that effective structure factor transitions in the low-q region, indicative of interparticle interactions, consistently emerged below 25 mg/mL. Subsequently, 11 additional mAbs were analyzed at 1–25 mg/mL using automated liquid handling and flow cells to enable high-throughput screening. High-viscosity mAbs exhibited detectable low-q upturns at concentrations ≤10 mg/mL, whereas low-viscosity mAbs showed downturns. A classification criterion based on effective structure factor transitions accurately classified all high- and low-viscosity mAbs at 150 mg/mL, offering a scalable, sample-efficient alternative to conventional methods. These results extend recent findings on the concentration-dependent sensitivity of SAXS to short-range attractions, demonstrating that they can emerge at lower concentrations than previously reported. This study presents the most comprehensive and diverse SAXS dataset for mAbs reported to date within a single formulation, providing a valuable resource for developing and validating coarse-grained models that can more accurately capture intermolecular interactions governing high-concentration solution behavior, thereby enabling rational antibody engineering and improved developability.

36 MATERIALS SCIENCE↗

NASA Tech Briefs, September 2013

Topics include: ISS Ammonia Leak Detection Through X-Ray Fluorescence; A System for Measuring the Sway of the Vehicle Assembly Building; Fast, High-Precision Readout Circuit for Detector Arrays; Victim Simulator for Victim Detection Radar; Hydrometeor Size Distribution Measurements by Imaging the Attenuation of a Laser Spot; Quasi-Linear Circuit; High-Speed, High-Resolution Time-to-Digital Conversion; Li-Ion Battery and Supercapacitor Hybrid Design for Long Extravehicular Activities; Ultrasonic Low-Friction Containment Plate for Thermal and Ultrasonic Stir Weld Processes; High-Powered, Ultrasonically Assisted Thermal Stir Welding; Next-Generation MKIII Lightweight HUT/Hatch Assembly; Centrifugal Sieve for Gravity-Level-Independent Size; Segregation of Granular Materials; Ion Exchange Technology Development in Support of the Urine Processor Assembly; Nickel-Graphite Composite Compliant Interface and/or Hot Shoe Material; UltraSail CubeSat Solar Sail Flight Experiment; Mechanism for Deploying a Long, Thin-Film Antenna From a Rover; Counterflow Regolith Heat Exchanger; Acquisition and Retaining Granular Samples via a Rotating Coring Bit; Very-Low-Cost, Rugged Vacuum System; Medicine Delivery Device With Integrated Sterilization and Detection; FRET-Aptamer Assays for Bone Marker Assessment, C-Telopeptide, Creatinine, and Vitamin D; Multimode Directional Coupler for Utilization of Harmonic Frequencies from TWTAs; Dual-Polarization, Multi-Frequency Antenna Array for use with Hurricane Imaging Radiometer; Complementary Barrier Infrared Detector (CBIRD) Contact Methods; Autonomous Control of Space Nuclear Reactors; High-Power, High-Speed Electro-Optic Pockels Cell Modulator; Covariance Analysis Tool (G-CAT) for Computing Ascent, Descent, and Landing Errors; Enigma Version 12; Micrometeoroid and Orbital Debris (MMOD) Shield Ballistic Limit Analysis Program; Spitzer Telemetry Processing System; Planetary Protection Bioburden Analysis Program; Wing Leading Edge RCC Rapid Response Damage Prediction Tool (IMPACT2); ISSM: Ice Sheet System Model; Automated Loads Analysis System (ATLAS); Integrated Main Propulsion System Performance Reconstruction Process/Models. Phoenix Telemetry Processor; Contact Graph Routing Enhancements Developed in ION for DTN; GFEChutes Lo-Fi; Advanced Strategic and Tactical Relay Request Management for the Mars Relay Operations Service; Software for Generating Troposphere Corrections for InSAR Using GPS and Weather Model Data; Ionospheric Specifications for SAR Interferometry (ISSI); Implementation of a Wavefront-Sensing Algorithm; Sally Ride EarthKAM - Automated Image Geo-Referencing Using Google Earth Web Plug-In; Trade Space Specification Tool (TSST) for Rapid Mission Architecture (Version 1.2); Acoustic Emission Analysis Applet (AEAA) Software; Memory-Efficient Onboard Rock Segmentation; Advanced Multimission Operations System (ATMO); Robot Sequencing and Visualization Program (RSVP); Automating Hyperspectral Data for Rapid Response in Volcanic Emergencies; Raster-Based Approach to Solar Pressure Modeling; Space Images for NASA JPL Android Version; Kinect Engineering with Learning (KEWL); Spacecraft 3D Augmented Reality Mobile App; MPST Software: grl_pef_check; Real-Time Multimission Event Notification System for Mars Relay; SIM_EXPLORE: Software for Directed Exploration of Complex Systems; Mobile Timekeeping Application Built on Reverse-Engineered JPL Infrastructure; Advanced Query and Data Mining Capabilities for MaROS; Jettison Engineering Trajectory Tool; MPST Software: grl_suppdoc; PredGuid+A: Orion Entry Guidance Modified for Aerocapture; Planning Coverage Campaigns for Mission Design and Analysis: CLASP for DESDynl; and Space Place Prime.

Source record↗

Total Hydrocarbon Content (THC) Testing in Liquid Oxygen (LOX)

The measured Total Hydrocarbon Content (THC) levels in liquid oxygen (LOX) systems at Stennis Space Center (SSC) have shown wide variations. Examples of these variations include the following: 1) differences between vendor-supplied THC values and those obtained using standard SSC analysis procedures; and 2) increasing THC values over time at an active SSC test stand in both storage and run vessels. A detailed analysis of LOX sampling techniques, analytical instrumentation, and sampling procedures will be presented. Additional data obtained on LOX system operations and LOX delivery trailer THC values during the past 12-24 months will also be discussed. Field test results showing THC levels and the distribution of the THC's in the test stand run tank, modified for THC analysis via dip tubes, will be presented.

Meneghelli, B. J.↗

Cryogenic Curation of Lunar Samples Returned to Earth

Future lunar missions may collect samples that have been preserved at sub-freezing or even cryogenic temperatures. For such samples, the study of volatiles and temperature-sensitive minerals will have high priority. Valuable geochemical and mineralogical information will be lost if such samples are allowed to reach ambient temperatures on Earth. The ability to store, document, subdivide, and transport extraterrestrial geologic samples while maintaining sub-freezing or cryogenic temperatures, possibly as low as 40 K, is required for the complete scientific study of samples from cold environments. A lunar cryogenic sample return mission might require a combination of passive cooling during collection and cruise and active cooling during and after re-entry for maintaining desired temperatures. Once on Earth, cryocontainment must be maintained through delivery to a cryogenic chamber in the curatorial facility. This cryogenic curation chamber would include cameras and robotic manipulators for preliminary examination, subdivision of samples, and specialized sample allocation containers for shipment to laboratories world-wide. This presentation describes the planning and feasibility of cryogenic curation with current technologies developed for the superconductor industry. In addition, significant advanced research and development would be required to tailor some of these technologies to the task of sample return and long term curation of lunar samples at low temperatures in order to preserve their scientific integrity.

Calaway, Michael J.↗

Estimating Vadose Zone Flow Properties at the 100 K-East Soil Flushing Site Using ERT Monitoring Data: 2023 Interim Report - 100 KE Soil Property Estimation

In situ soil flushing is being using at the Hanford 100 K-East (100 KE) area to transport mobile chromium contamination in the vadose zone to the water table, where it can be collected and treat through pump and treat operations. The efficacy of soil flushing is directly related to the volume of clean water that infiltrates through contaminated soils. In practice, it is infeasible to comprehensively monitor which regions of the vadose zone are being infiltrated through direct sampling of pore water. Consequently, there can be significant uncertainty about which regions of the subsurface have been treated, especially if hydrogeologic conditions are favorable for the development of unstable flows and preferred flow pathways through the vadose zone (Jarvis, Koestel, and Larsbo 2016). Current approaches for quantitative monitoring of soil flushing performance rely on contaminant concentration measurements collected from extractions wells. There is no quantitative information on the volume of flush water delivered to targeted regions of the vadose zone at the Hanford Site, leading to significant uncertainty regarding source term removal and long-term impacts to groundwater. If the subsurface hydrogeologic properties at the 100 KE Area were adequately known, qualitative metrics of soil flushing performance could be simulated, thereby negating expenses required to obtain quantitative performance information through borehole drilling/sampling. However, estimating in situ hydrogeologic properties has long proven elusive, due primarily to a lack of sufficient information to constrain heterogeneous property estimates to a useful degree of certainty. Estimating vadose zone hydrogeologic properties is particularly challenging due the dependence of hydraulic conductivity on saturation. This report describes progress toward a first-of-its-kind demonstration using surface time-lapse 3D electrical resistivity tomography (ERT) monitoring data to estimate the hydrogeologic properties that control flush water transport at the 100 KE soil flushing site. The ultimate objective is (1) to verify sufficient information exists in the ERT monitoring data to adequately resolve vadose zone hydraulic properties, and (2) generate a “digital twin” (i.e., a numerical simulator) that can be used to simulate the amount of flush water that has been delivered to each targeted region of the vadose zone, and thereby assess the efficacy of flush water delivery. Resulting performance estimates can be used in leu of comprehensive borehole drilling and direct sampling (or wellbore logging) that would otherwise be required to obtain the same information.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of Waste Feed Delivery Small Scale Mixing Demonstration Simulant to Hanford Waste (Rev.1)

The Hanford double-shell tank (DST) system provides the staging location for waste that will be transferred to the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Specific WTP acceptance criteria for waste feed delivery describe the physical and chemical characteristics of the waste that must be met before the waste is transferred from the DSTs to the WTP. One of the more challenging requirements relates to the sampling and characterization of the undissolved solids (UDS) in a waste feed DST because the waste contains solid particles that settle and their concentration and relative proportion can change during the transfer of the waste in individual batches. A key uncertainty in the waste feed delivery system is the potential variation in UDS transferred in individual batches in comparison to an initial sample used for evaluating the acceptance criteria. To address this uncertainty, a number of small-scale mixing tests have been conducted as part of Washington River Protection Solutions' Small Scale Mixing Demonstration (SSMD) project to determine the performance of the DST mixing and sampling systems. A series of these tests have used a five-part simulant composed of particles of different size and density and designed to be equal or more challenging than AY-102 waste. This five-part simulant, however, has not been compared with the broad range of Hanford waste, and thus there is an additional uncertainty that this simulant may not be as challenging as the most difficult Hanford waste. The purpose of this study is to quantify how the current five-part simulant compares to all of the Hanford sludge waste, and to suggest alternate simulants that could be tested to reduce the uncertainty in applying the current testing results to potentially more challenging wastes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TH-CD-209-10: Scanning Proton Arc Therapy (SPArc) - The First Robust and Delivery-Efficient Spot Scanning Proton Arc Therapy

Purpose: To develop a delivery-efficient proton spot-scanning arc therapy technique with robust plan quality. Methods: We developed a Scanning Proton Arc(SPArc) optimization algorithm integrated with (1)Control point re-sampling by splitting control point into adjacent sub-control points; (2)Energy layer re-distribution by assigning the original energy layers to the new sub-control points; (3)Energy layer filtration by deleting low MU weighting energy layers; (4)Energy layer re-sampling by sampling additional layers to ensure the optimal solution. A bilateral head and neck oropharynx case and a non-mobile lung target case were tested. Plan quality and total estimated delivery time were compared to original robust optimized multi-field step-and-shoot arc plan without SPArc optimization (Arcmulti-field) and standard robust optimized Intensity Modulated Proton Therapy(IMPT) plans. Dose-Volume-Histograms (DVH) of target and Organ-at-Risks (OARs) were analyzed along with all worst case scenarios. Total delivery time was calculated based on the assumption of a 360 degree gantry room with 1 RPM rotation speed, 2ms spot switching time, beam current 1nA, minimum spot weighting 0.01 MU, energy-layer-switching-time (ELST) from 0.5 to 4s. Results: Compared to IMPT, SPArc delivered less integral dose(−14% lung and −8% oropharynx). For lung case, SPArc reduced 60% of skin max dose, 35% of rib max dose and 15% of lung mean dose. Conformity Index is improved from 7.6(IMPT) to 4.0(SPArc). Compared to Arcmulti-field, SPArc reduced number of energy layers by 61%(276 layers in lung) and 80%(1008 layers in oropharynx) while kept the same robust plan quality. With ELST from 0.5s to 4s, it reduced 55%–60% of Arcmulti-field delivery time for the lung case and 56%–67% for the oropharynx case. Conclusion: SPArc is the first robust and delivery-efficient proton spot-scanning arc therapy technique which could be implemented in routine clinic. For modern proton machine with ELST close to 0.5s, SPArc would be a popular treatment option for both single and multi-room center.

60 APPLIED LIFE SCIENCES↗

Chemical and Solar Electric Propulsion Systems Analyses for Mars Sample Return Missions

Conceptual in-space transfer stages, including those utilizing solar electric propulsion, chemical propulsion, and chemical propulsion with aerobraking or aerocapture assist at Mars, were evaluated. Roundtrip Mars sample return mission vehicles were analyzed to determine how specific system technology selections influence payload delivery capability. Results show how specific engine, thruster, propellant, capture mode, trip time and launch vehicle technology choices would contribute to increasing payload or decreasing the size of the required launch vehicles. Heliocentric low-thrust trajectory analyses for Solar Electric Transfer were generated with the SEPTOP code.

Donahue, Benjamin B.↗

Comparison of Waste Feed Delivery Small Scale Mixing Demonstration Simulant to Hanford Waste

The Hanford double-shell tank (DST) system provides the staging location for waste that will be transferred to the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Specific WTP acceptance criteria for waste feed delivery describe the physical and chemical characteristics of the waste that must be met before the waste is transferred from the DSTs to the WTP. One of the more challenging requirements relates to the sampling and characterization of the undissolved solids (UDS) in a waste feed DST because the waste contains solid particles that settle and their concentration and relative proportion can change during the transfer of the waste in individual batches. A key uncertainty in the waste feed delivery system is the potential variation in UDS transferred in individual batches in comparison to an initial sample used for evaluating the acceptance criteria. To address this uncertainty, a number of small-scale mixing tests have been conducted as part of Washington River Protection Solutions' Small Scale Mixing Demonstration (SSMD) project to determine the performance of the DST mixing and sampling systems. A series of these tests have used a five-part simulant composed of particles of different size and density and designed to be equal or more challenging than AY-102 waste. This five-part simulant, however, has not been compared with the broad range of Hanford waste, and thus there is an additional uncertainty that this simulant may not be as challenging as the most difficult Hanford waste. The purpose of this study is to quantify how the current five-part simulant compares to all of the Hanford sludge waste, and to suggest alternate simulants that could be tested to reduce the uncertainty in applying the current testing results to potentially more challenging wastes.

Hanford Waste↗

Preliminary Scaling Estimate for Select Small Scale Mixing Demonstration Tests

The Hanford Site double-shell tank (DST) system provides the staging location for waste that will be transferred to the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Specific WTP acceptance criteria for waste feed delivery describe the physical and chemical characteristics of the waste that must be met before the waste is transferred from the DSTs to the WTP. One of the more challenging requirements relates to the sampling and characterization of the undissolved solids (UDS) in a waste feed DST because the waste contains solid particles that settle and their concentration and relative proportion can change during the transfer of the waste in individual batches. A key uncertainty in the waste feed delivery system is the potential variation in UDS transferred in individual batches in comparison to an initial sample used for evaluating the acceptance criteria. To address this uncertainty, a number of small-scale mixing tests have been conducted as part of Washington River Protection Solutions’ Small Scale Mixing Demonstration (SSMD) project to determine the performance of the DST mixing and sampling systems.

Double-shell Tank↗

SU-E-T-807: VMAT Vs. DIMRT Vs. SsIMRT Assessing the Dosimetric Parameters of Cervical Carcinoma Treatment with a 20-Patient Sample

Purpose: The purpose of this study is to assess the dosimetric parameters of cervical carcinoma treatment using 3 different radiation therapy delivery Methods: volumetric-modulated arc therapy (VMAT), the static-field dynamic multileaf collimator intensity-modulated radiation therapy (dIMRT) and the static-field step-and-shoot intensity-modulated radiotherapy (ssIMRT). Methods: Twenty patients with cervical carcinoma were selected to be planned with dual arc VMAT, dIMRT and ssIMRT using Monaco 3.3 TPS on the Axesse™ linear accelerator in this investigation. The total dose of the planning target volume (PTV) is 60Gy. The homogeneity index (HI), conformity index (CI), dose volume histograms (DVHs), delivery efficiency, dose of organs at risks (bladder, rectum, and femoral heads), were all measured. Results: Dose distribution in 3 different radiation therapy delivery methods satisfied clinical requirements. Mean HI of PTV with VMAT, dIMRT and ssIMRT is 1.08, 1.10, and 1.09 (p>0.05). Mean CI of PTV with VMAT, dIMRT and ssIMRT is 0.82, 0.8 and 0.8 (p>0.05). For the DVH of V10, V20 and V30 in bladder, there was a significant difference: VMAT>dIMRT=ssIMRT (p <0.05). For the DVH of V40 and V50, there was a significant difference: VMAT dIMRT >ssIMRT (p <0.05). Conclusion: The results show that VMAT has a great advantage in delivery efficiency than dIMRT and ssIMRT, without compromise to the PTV coverage, HI and CI. The delivery methods should be considered under the actual cervical carcinoma radiotherapy situation.

60 APPLIED LIFE SCIENCES↗

Spot-Scanning Proton Arc (SPArc) Therapy: The First Robust and Delivery-Efficient Spot-Scanning Proton Arc Therapy

Purpose: To present a novel robust and delivery-efficient spot-scanning proton arc (SPArc) therapy technique. Methods and Materials: A SPArc optimization algorithm was developed that integrates control point resampling, energy layer redistribution, energy layer filtration, and energy layer resampling. The feasibility of such a technique was evaluated using sample patients: 1 patient with locally advanced head and neck oropharyngeal cancer with bilateral lymph node coverage, and 1 with a nonmobile lung cancer. Plan quality, robustness, and total estimated delivery time were compared with the robust optimized multifield step-and-shoot arc plan without SPArc optimization (Arc{sub multi-field}) and the standard robust optimized intensity modulated proton therapy (IMPT) plan. Dose-volume histograms of target and organs at risk were analyzed, taking into account the setup and range uncertainties. Total delivery time was calculated on the basis of a 360° gantry room with 1 revolutions per minute gantry rotation speed, 2-millisecond spot switching time, 1-nA beam current, 0.01 minimum spot monitor unit, and energy layer switching time of 0.5 to 4 seconds. Results: The SPArc plan showed potential dosimetric advantages for both clinical sample cases. Compared with IMPT, SPArc delivered 8% and 14% less integral dose for oropharyngeal and lung cancer cases, respectively. Furthermore, evaluating the lung cancer plan compared with IMPT, it was evident that the maximum skin dose, the mean lung dose, and the maximum dose to ribs were reduced by 60%, 15%, and 35%, respectively, whereas the conformity index was improved from 7.6 (IMPT) to 4.0 (SPArc). The total treatment delivery time for lung and oropharyngeal cancer patients was reduced by 55% to 60% and 56% to 67%, respectively, when compared with Arc{sub multi-field} plans. Conclusion: The SPArc plan is the first robust and delivery-efficient proton spot-scanning arc therapy technique, which could potentially be implemented into routine clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗