Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “risk matrix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Effect of Ex Vivo Ionizing Radiation on Static and Fatigue Properties of Mouse Vertebral Bodies

For a variety of medical and scientific reasons, human bones can be exposed to a wide range of ionizing radiation levels. In vivo radiation therapy (0.05 kGy) is used in cancer treatment, and ex vivo irradiation (25-35 kGy) is used to sterilize bone allografts. Ionizing radiation in these applications has been shown to increase risk of fracture, decrease bone quality and degrade collagen integrity. Past studies have investigated the deleterious effects of radiation on cortical or trabecular bone specimens individually, but to date no studies have examined whole bones containing both cortical and trabecular tissue. Furthermore, a clear relationship between the dose and the mechanical and biochemical response of bone's extracellular matrix has yet to be established for doses ranging from cancer therapy to allograft sterilization (0.05-35 kGy). To gain insight into these issues, we conducted an ex vivo radiation study to investigate non-cellular (i.e. matrix) effects of ionizing radiation dose on vertebral whole bone mechanical properties, over a range of radiation doses (0.05-35 kGy), with a focus on any radiation-induced changes in collagen. With underlying mechanisms of action in mind, we hypothesized that any induced reductions in mechanical properties would be associated with changes in collagen integrity. METHODS: 20-week old female mice were euthanized and the lumbar spine was dissected using IACUC approved protocols. The lumbar vertebrae (L1- S1) were extracted from the spine via cuts through adjacent intervertebral discs, and the endplates, posterior processes, surrounding musculature, and soft tissues were removed (approx. 1.5mm diameter, approx. 2mm height). Specimens were randomly assigned to one of five groups for ex vivo radiation exposure: x-ray irradiation at 0.05, 1, 17, or 35 kGy, or a 0 kGy control. Following irradiation, the vertebrae were imaged using microcomputed tomography (micro-CT) and then subjected to either monotonic compressive loading to failure or uniform cyclic compressive loading. During cyclic testing, samples were loaded in force control to a force level that corresponded to a strain of 0.46%, as determined in advance by a linearly elastic micro-CT-based finite element analysis for each specimen. Tests were stopped at imminent fracture, defined as a rapid increase in strain. The main outcome for the monotonic test was the strength (maximum force); for cyclic testing it was the fatigue life (log of the number of cycles of loading at imminent failure). A fluorometric assay was used on the S1 vertebrae to measure the number of non-enzymatic collagen crosslinks[4]. A one-way ANOVA was performed on mechanical properties and collagen crosslinks; means were compared with controls using Dunnett's method, with a Tukey-Kramer post-hoc analysis when significance was found (p < or = 0.05). RESULTS: Compared to the unirradiated control group, the concentration of non-enzymatic collagen crosslinks was significantly increased for all irradiated groups (p < 0.0001), and being higher by at least 50% (Figure 1a). By contrast, the radiation effects on the collagen were only evident at the higher doses. For irradiation exposures of 17 kGy or more, strength decreased substantially as the radiation level was increased, but no effect was evident below 17 kGy (Figure 1b). There was no significant change in the stiffness or maximum displacement for any radiation dose (p>0.05). The finite element analysis prescribed force level for cyclic loading exceeded the measured (monotonic) strength of the 17 and 35 kGy irradiated groups (mean +/- SD, 20.6 +/- 5.6 N; 13.2 +/- 3.7 N, respectively) and therefore these groups were eliminated from the fatigue study. The fatigue life for the 0.05 and 1 kGy groups were similar to each other and were not statistically significantly different from the control group (Figure 1c).

radiation↗

The Mass Change Designated Observable Study: Overview and Results

The 2017–2027 United States National Academy of Sciences Decadal Survey (DS) for Earth Science and Applications from Space identified Mass Change (MC) as one of five Designated Observables (DOs) having the highest priority in terms of Earth observations required to advance Earth system science over the next decade. In response to this designation, NASA initiated several multi-center studies, with the goal of recommending observing system architectures for each DO for implementation within this decade. This paper provides an overview of the Mass Change Designated Observable (MCDO) Study along with key findings. The study process included: (a) generation of a Science and Applications Traceability Matrix (SATM) that maps required measurement parameters to the DS Science and Applications Objectives; (b) identification of three architecture classes relevant for measuring mass change: Precise Orbit Determination (POD), Satellite-Satellite-Tracking (SST) and Gravity Gradiometry (GG), along with variants within each architecture class; and (c) creation of a Value Framework process that considers science value, cost, risk, schedule, and partnership opportunities, to identify and recommend high value observing systems for further in-depth study. The study team recommended the implementation of an SST architecture, and identified variants that simultaneously (a) satisfy the baseline measurement parameters of the SATM; (b) maximize the probability of providing overlap with the Gravity Recovery and Climate Experiment Follow-On (GRACE-FO) mission currently in operation, accelerating science return from both missions; and (c) provide a pathway towards substantial improvements in resolution and accuracy of mass change data products relative to the program of record.

D N Wiese↗

Overview of the carbon fiber problem

Carbon fibers (CF) composite structures are being utilized more as alternatives to metals in both civilian and military applications. They are valued for their light weight and high strength as well as for their ease of designing structures with specific shapes and sizes. However, a problem may exist due to the high conductivity of CF. CF are manufactured from a precursor material which is subjected to great stress and heat treatment causing a change in the physical and electrical properties. The fibers are bound together by a matrix of epoxy. In the event of fire (aircraft accident) the epoxy would burn away releasing these fibers into the atmosphere. When these fibers come in contact with electronic equipment, they might cause damage to by settling on electrical junctions. An overview is given of the objectives for a study, and the approach and methodology developed for determination of risk profiles.

Source record↗

Realistic Covariance Prediction for the Earth Science Constellation

Routine satellite operations for the Earth Science Constellation (ESC) include collision risk assessment between members of the constellation and other orbiting space objects. One component of the risk assessment process is computing the collision probability between two space objects. The collision probability is computed using Monte Carlo techniques as well as by numerically integrating relative state probability density functions. Each algorithm takes as inputs state vector and state vector uncertainty information for both objects. The state vector uncertainty information is expressed in terms of a covariance matrix. The collision probability computation is only as good as the inputs. Therefore, to obtain a collision calculation that is a useful decision-making metric, realistic covariance matrices must be used as inputs to the calculation. This paper describes the process used by the NASA/Goddard Space Flight Center's Earth Science Mission Operations Project to generate realistic covariance predictions for three of the Earth Science Constellation satellites: Aqua, Aura and Terra.

Duncan, Matthew↗

Fibrous-Ceramic/Aerogel Composite Insulating Tiles

Fibrous-ceramic/aerogel composite tiles have been invented to afford combinations of thermal-insulation and mechanical properties superior to those attainable by making tiles of fibrous ceramics alone or aerogels alone. These lightweight tiles can be tailored to a variety of applications that range from insulating cryogenic tanks to protecting spacecraft against re-entry heating. The advantages and disadvantages of fibrous ceramics and aerogels can be summarized as follows: Tiles made of ceramic fibers are known for mechanical strength, toughness, and machinability. Fibrous ceramic tiles are highly effective as thermal insulators in a vacuum. However, undesirably, the porosity of these materials makes them permeable by gases, so that in the presence of air or other gases, convection and gas-phase conduction contribute to the effective thermal conductivity of the tiles. Other disadvantages of the porosity and permeability of fibrous ceramic tiles arise because gases (e.g., water vapor or cryogenic gases) can condense in pores. This condensation contributes to weight, and in the case of cryogenic systems, the heat of condensation undesirably adds to the heat flowing to the objects that one seeks to keep cold. Moreover, there is a risk of explosion associated with vaporization of previously condensed gas upon reheating. Aerogels offer low permeability, low density, and low thermal conductivity, but are mechanically fragile. The basic idea of the present invention is to exploit the best features of fibrous ceramic tiles and aerogels. In a composite tile according to the invention, the fibrous ceramic serves as a matrix that mechanically supports the aerogel, while the aerogel serves as a low-conductivity, low-permeability filling that closes what would otherwise be the open pores of the fibrous ceramic. Because the aerogel eliminates or at least suppresses permeation by gas, gas-phase conduction, and convection, the thermal conductivity of such a composite even at normal atmospheric pressure is not much greater than that of the fibrous ceramic alone in a vacuum.

White, Susan M.↗

Analysis of nuclear waste disposal in space, phase 3. Volume 2: Technical report

The options, reference definitions and/or requirements currently envisioned for the total nuclear waste disposal in space mission are summarized. The waste form evaluation and selection process is documented along with the physical characteristics of the iron nickel-base cermet matrix chosen for disposal of commercial and defense wastes. Safety aspects of radioisotope thermal generators, the general purpose heat source, and the Lewis Research Center concept for space disposal are assessed as well as the on-pad catastrophic accident environments for the uprated space shuttle and the heavy lift launch vehicle. The radionuclides that contribute most to long-term risk of terrestrial disposal were determined and the effects of resuspension of fallout particles from an accidental release of waste material were studied. Health effects are considered. Payload breakup and rescue technology are discussed as well as expected requirements for licensing, supporting research and technology, and safety testing.

Rice, E. E.↗

Diffusion bonded boron/aluminum spar-shell fan blade

Design and process development tasks intended to demonstrate composite blade application in large high by-pass ratio turbofan engines are described. Studies on a 3.0 aspect radio space and shell construction fan blade indicate a potential weight savings for a first stage fan rotor of 39% when a hollow titanium spar is employed. An alternate design which featured substantial blade internal volume filled with titanium honeycomb inserts achieved a 14% potential weight savings over the B/M rotor system. This second configuration requires a smaller development effort and entails less risk to translate a design into a successful product. The feasibility of metal joining large subsonic spar and shell fan blades was demonstrated. Initial aluminum alloy screening indicates a distinct preference for AA6061 aluminum alloy for use as a joint material. The simulated airfoil pressings established the necessity of rigid air surfaces when joining materials of different compressive rigidities. The two aluminum alloy matrix choices both were successfully formed into blade shells.

Carlson, C. E. K.↗

Uterine responses to feeding soy protein isolate and treatment with 17β-estradiol differ in ovariectomized female rats

There are concerns regarding reproductive toxicity from consumption of soy foods, including an increased risk of endometriosis and endometrial cancer, as a result of phytoestrogen consumption. In this study, female rats were fed AIN-93G diets made with casein (CAS) or soy protein isolate (SPI) from postnatal day (PND) 30, ovariectomized on PND 50 and infused with 5 μg/kg/d 17β-estradiol (E2) or vehicle. E2 increased uterine wet weight (P < 0.05). RNAseq analysis revealed that E2 significantly altered expression of 1991 uterine genes (P < 0.05). SPI feeding had no effect on uterine weight and altered expression of far fewer genes than E2 at 152 genes (P < 0.05). Overlap between E2 and SPI genes was limited to 67 genes. Functional annotation analysis indicated significant differences in uterine biological processes affected by E2 and SPI and little evidence for recruitment of estrogen receptor (ER)α to the promoters of ER-responsive genes after SPI feeding. The major E2 up-regulated uterine pathways were carcinogenesis and extracellular matrix organization, whereas SPI feeding up-regulated uterine peroxisome proliferator activated receptor (PPAR) signaling and fatty acid metabolism. The combination of E2 and SPI resulted in significant regulation of 504 fewer genes relative to E2 alone. The ability of E2 to induce uterine proliferation in response to the carcinogen dimethybenz(a)anthracene (DMBA) as measured by expression of PCNA and Ki67 mRNA was suppressed by feeding SPI (P < 0.05). These data suggest that SPI is a selective estrogen receptor modulator (SERM) interacting with a small sub-set of E2-regulated genes and is anti-estrogenic in the presence of endogenous estrogens. - Highlights: • Concerns exist regarding risk of uterine cancer from consumption of soy products. • These concerns are related to potential estrogenicity. • Estradiol and soy protein isolate effects on uterine gene expression were compared. • Soy acts as a selective estrogen receptor modulator not a weak estrogen. • Soy feeding blocked uterine proliferation after treatment with estradiol and DMBA.

60 APPLIED LIFE SCIENCES↗

Degradation Kinetics of VX

O-ethyl S-(2-diisopropylaminoethyl)phosphonothiolate (VX) is the most toxic of the conventional chemical warfare agents. It is a persistent compound, an attribute derived from its relative involatility and slow rates of hydrolysis. These properties suggest that VX can linger in an exposed environment for extended periods of time long after the air has cleared. Concern over prolonged risk from VX exposure is exacerbated by the fact that it poses a dermal contact hazard. Hence a detailed understanding of volatilization rates, and degradation pathways and rates occurring in various environments is needed. Historically, volatilization has not been considered to be an important mechanism for VX depletion, but recent studies have shown that a significant fraction of VX may volatilize, depending on the matrix. A significant body of research has been conducted over the years to unravel VX degradation reaction pathways and to quantify the rates at which they proceed. Rigorous measurement of degradation rates is frequently difficult, and thus in many cases the degradation of VX has been described in terms of half lives, while in fewer instances rate constants have been measured. This variable approach to describing degradation kinetics reflects uncertainty regarding the exact nature of the degradation mechanisms. In this review, rates of VX degradation are compared on the basis of pseudo-first order rate constants, in order to provide a basis for assessing likelihood of VX persistence in a given environment. An issue of specific concern is that one VX degradation pathway produces S-2-(diisopropylaminoethyl) methylphosphonothioic acid (known as EA2192), which is a degradation product that retains much of the original toxicity of VX. Consequently degradation pathways and rates for EA2192 are also discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prototyping and Testing a New Volumetric Curvature Tool for Modeling Reservoir Compartments and Leakage Pathways in the Arbuckle Saline Aquifer: Reducing Uncertainty in CO 2 Storage and Permanence

This DOE-funded project evaluates the utility of seismic volumetric curvature (VC) for predicting stratal and structural architecture diagnostic of paleokarst reservoirs. Of special interest are applications geared toward carbon capture, utilization, and storage (CCUS). VC has been championed for identifying faults (offset <¼ λ) that cannot be imaged by conventional 3-D seismic attributes such as coherence. The objective of this research was to evaluate VC-techniques for reducing uncertainties in reservoir compartmentalization studies and seal risk assessments especially for saline aquifers. A 2000-ft horizontal lateral was purposefully drilled across VC-imaged lineaments—interpreted to record a fractured and a fault-bounded doline—to physically confirm their presence. The 15-mi² study area is located in southeastern Bemis-Shutts Field, which is situated along the crest of the Central Kansas Uplift (CKU) in Ellis County, Kansas. The uppermost Arbuckle (200+ ft) has extensive paleokarst including collapsed paleocaverns and dolines related to exceedingly prolonged pre-Simpson (Sauk–Tippecanoe) and/or pre-Pennsylvanian subaerial exposure. A lateral borehole was successfully drilled across the full extent (~1100 ft) of a VC-inferred paleokarst doline. Triple combo (GR-neutron/density-resistivity), full-wave sonic, and borehole micro-imager logs were successfully run to TD on drill-pipe. Results from the formation evaluation reveal breccias (e.g., crackle, mosaic, chaotic), fractures, faults, vugs (1-6"), and unaffected host strata consistent with the pre-spud interpretation. Well-rounded pebbles were also observed on the image log. VC-inferred lineaments coincide with 20–80-ft wide intervals of high GR values (100+ API), matrix-rich breccias, and faults. To further demonstrate their utility, VC attributes are integrated into a geocellular modeling workflow: 1) to constrain the structural model; 2) to generate facies probability grids, and; 3) to collocate petrophysical models to separate-vug rock fabrics along solution-enlarged fault and fracture systems. Simulation-based studies demonstrate a potential alternative field development model for developing CO 2 storage sites that target carbonate reservoirs overprinted by paleokarst. Simulation results for this complex reservoir indicate that individual fault blocks could function as discrete containers for CO 2 storage thereby reducing the risk of plume migration outside the legally defined extent of the permitted storage site. Vertically extensive, anastomosing, solution-enlarged fault/fracture systems — infilled by clay-rich sediments — would operate as non-to-low permeability vertical "curtains" that restrict CO 2 movement beyond the confines of the CO 2 storage site. Such a location could be developed in a checker-board fashion with CO 2 injection operations occurring in one block and surveillance operations occurring in the adjacent block. Such naturally partitioned reservoirs may be ideal candidates for reducing risks associated with CO 2 plume breakthrough.

02 PETROLEUM↗

The Influence of Hydraulic Fracturing on Carbon Storage Performance: Hydraulic Fracturing in Carbon Storage

We report that conventional principles of the design and operation of geologic carbon storage (GCS) require injecting CO 2 below the caprock fracturing pressure to ensure the integrity of the storage complex. In nonideal storage reservoirs with relatively low permeability, pressure buildup can lead to hydraulic fracturing of the reservoir and caprock. While the GCS community has generally viewed hydraulic fractures as a key risk to storage integrity, a carefully designed stimulation treatment under appropriate geologic conditions could provide improved injectivity while maintaining overall seal integrity. A vertically contained hydraulic fracture, either in the reservoir rock or extending a limited height into the caprock, provides an effective means to access reservoir volume far from the injection well. Employing a fully coupled numerical model of hydraulic fracturing, solid deformation, and matrix fluid flow, we study the enabling conditions, processes, and mechanisms of hydraulic fracturing during CO 2 injection. A hydraulic fracture's pressure-limiting behavior dictates that the near-well fluid pressure is only slightly higher than the fracturing pressure of the rock and is insensitive to injection rate and mechanical properties of the formation. Although a fracture contained solely within the reservoir rock with no caprock penetration, would be an ideal scenario, poroelastic principles dictate that sustaining such a fracture could lead to continuously increasing pressure until the caprock fractures. We also investigate the propagation pattern and injection pressure responses of a hydraulic fracture propagating in a caprock subjected to heterogeneous in situ stress. In conclusion, the results have important implications for the use of hydraulic fracturing as a tool for managing storage performance.

58 GEOSCIENCES↗

Final Results of the Protected Superficial Femoral Artery Trial Using the FilterWire EZ System

The purpose of this study was to evaluate the safety and efficacy of debris-capture for distal protection using the FilterWire EZ Embolic Protection System (Boston Scientific, Mountain View, CA) with the additional aim to further define the incidence of distal embolization during superficial femoral artery (SFA) interventions. A prospective, single-centre registry was designed to evaluate the performance of the FilterWire EZ in capturing debris during standard SFA percutaneous intervention. The PRO-RATA study included 30 patients suitable for PTA (Fontaine IIb to III or Rutherford I to II classification). The primary end points were occurrence of distal embolization or decreased runoff, improvement in ankle-brachial index ankle-brachial index (ABI) after the procedure, and number of filters containing emboli. Secondary end points included major adverse events (i.e., procedure- or device-related death and/or clinical target lesion revascularisation), device delivery, deployment success, and incidence of embolic recovery (patients with device success exhibiting embolic protection in the filter). Procedural success was determined as {<=}30% residual stenosis with no worsening of distal runoff as determined on angiography. A total of 29 patients (age 66.2 {+-} 12 years; total no. of limbs = 30; total no. of lesions = 30) suitable for PTA were enrolled in the study between February 2007 and March 2008. There were 26 patients with claudication (Fontaine IIB) and 3 patients with stage IV peripheral vascular disease. In one patient, lesions in both legs were treated. No procedural or device-related complications occured. The average degree of stenosis was 86 {+-} 7%. Stenosis length ranged from 8 to 88 mm. The average degree of residual stenosis was 10 {+-} 10%. ABI improved from 0.56 {+-} 0.16 to 0.92 {+-} 0.19 (P < 0.05). No restenosis or dissection was seen at 1-month ultrasound follow-up. Macroscopic debris was found in 27 of 30 filters of all distal protection devices used in all 29 patients. Debris particle size ranged from 90 to 2000 {mu}m (1200 {+-} 640). Histological debris analysis showed platelets, erythrocytes, inflammatory cells, extracellular matrix, and cholesterol as being the major components of emboli. Additional immunochemistry showed no correlation between lesion morphology and debris components. The FilterWire EZ is easy and safe to handle. The system caused no complications. In all cases, macroscopic debris was captured. Using a distal protection device during femoropopliteal interventions has the potential to prevent migration of debris, which may be important for high-risk patients with limited distal runoff.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanical response tissue analyzer for estimating bone strength

One of the major concerns for extended space flight is weakness of the long bones of the legs, composed primarily of cortical bone, that functions to provide mechanical support. The strength of cortical bone is due to its complex structure, described simplistically as cylinders of parallel osteons composed of layers of mineralized collagen. The reduced mechanical stresses during space flight or immobilization of bone on Earth reduces the mineral content, and changes the components of its matrix and structure so that its strength is reduced. Currently, the established clinical measures of bone strength are indirect. The measures are based on determinations of mineral density by means of radiography, photon absorptiometry, and quantitative computer tomography. While the mineral content of bone is essential to its strength, there is growing awareness of the limitations of the measurement as the sole predictor of fracture risk in metabolic bone diseases, especially limitations of the measurement as the sole predictor of fracture risk in metabolic bone diseases, especially osteoporosis. Other experimental methods in clinical trials that more directly evaluate the physical properties of bone, and do not require exposure to radiation, include ultrasound, acoustic emission, and low-frequency mechanical vibration. The last method can be considered a direct measure of the functional capacity of a long bone since it quantifies the mechanical response to a stimulus delivered directly to the bone. A low frequency vibration induces a response (impedance) curve with a minimum at the resonant frequency, that a few investigators use for the evaluation of the bone. An alternative approach, the method under consideration, is to use the response curve as the basis for determination of the bone bending stiffness EI (E is the intrinsic material property and I is the cross-sectional moment of inertia) and mass, fundamental mechanical properties of bone.

Arnaud, Sara B.↗

Diffusion Dominant Solute Transport Modelling in Fractured Media Under Deep Geological Environment - 12211

Deep geologic disposal of high activity and long-lived radioactive waste is gaining increasing support in many countries, where suitable low permeability geological formation in combination with engineered barriers are used to provide long term waste contaminant and minimise the impacts to the environment and risk to the biosphere. This modelling study examines the solute transport in fractured media under low flow velocities that are relevant to a deep geological environment. In particular, reactive solute transport through fractured media is studied using a 2-D model, that considers advection and diffusion, to explore the coupled effects of kinetic and equilibrium chemical processes. The effects of water velocity in the fracture, matrix porosity and diffusion on solute transport are investigated and discussed. Some illustrative modelled results are presented to demonstrate the use of the model to examine the effects of media degradation on solute transport, under the influences of hydrogeological (diffusion dominant) and microbially mediated chemical processes. The challenges facing the prediction of long term degradation such as cracks evolution, interaction and coalescence are highlighted. The potential of a novel microstructure informed modelling approach to account for these effects is discussed, particularly with respect to investigating multiple phenomena impact on material performance. The GRM code is used to examine the effects of media degradation for a geological waste disposal package, under the combined hydrogeological (diffusion dominant) and chemical effects in low groundwater flow conditions that are typical of deep geological disposal systems. An illustrative reactive transport modelling application demonstrates the use of the code to examine the interplay of kinetic controlled biogeochemical reactive processes with advective and diffusive transport, under the influence of media degradation. The initial model results are encouraging which show the disposal system to evolve in a physically realistic manner. In the example presented the reactive-transport coupling develops chemically reducing zones, which limit the transport of uranium. This illustrates the potential significance of media degradation and chemical effect on the transport of radionuclides which would need to be taken into account when examining the long-term behaviour and containment properties of the geological disposal system. Microstructure-informed modelling and its potential linkage with continuum flow modelling is a subject of ongoing studies. The approach of microstructure-informed modelling is discussed to provide insight and a mechanistic understanding of macroscopic parameters and their evolution. The proposed theoretical and methodological basis for microstructure-informed modelling of porous quasi-brittle media has the potential to develop into an explanatory and predictive tool for deriving mechanism-based, as opposed to phenomenological, evolution laws for macroscopic properties. These concepts in micro-scale modelling are likely to be applicable to the diffusion process, in addition to advective transport illustrated here for porous media. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determining the Most Influencing Medical Conditions in MEDPRAT’s SIN Directed Graph

INTRODUCTION: The Susceptibility Inference Network (SIN) is a network of medical conditions, part of the Medical Extensible Probabilistic Risk Assessment Tool (MEDPRAT) developed by NASA to assess human health and medical risk to space exploration missions. The SIN is subject matter expert informed and acts as a prototype that provides relationships and dependencies between events modeled by MEDPRAT. Each vertex in the SIN has a weight which evaluates the severity of having the condition regardless of the progression from or to that condition. In this presentation, we consider two statistics to measure that stand alone risk: Quality Time Lost (QTL) and Loss of Crew Life (LOCL). Our goal is to identify the medical conditions that contribute the most to crew members QTL and LOCL risks due to progression of conditions in the network. We investigate how different computation parameters result in different condition rankings and address the choice of parameters that allows appropriate interventions to ensure space mission success. METHODS: The Katz score, one of many centrality measures created for ranking purposes in network analysis, takes into account all possible walks through the network, penalizing each additional step in a walk by a factor α called the Katz parameter. The literature does not provide specific values for the choice of α. We derive an analytical relationship between α and the maximum path length which has influence on the Katz score and ranking. Based on the probability of progression of each condition in the SIN, we identify that maximum path length of interest and calculate α that is then used in the Katz formula to rank the conditions in the SIN. RESULTS AND CONCLUSION: The effective probabilities of the SIN matrix generally fall below 10−6, which is below the level of the least influencing condition in the set. This corresponds to the probability of at most six consecutive progressions of a condition. Consequently, we calculate the Katz Parameter α and get 0.32. We rank the medical conditions and find that Acute Radiation Symptom is the condition the most prone to contribute to quality time loss due to progression.

risk analysis↗

DOME: Directional medical embedding vectors from Electronic Health Records

Motivation: The increasing availability of Electronic Health Record (EHR) systems has created enormous potential for translational research. Recent developments in representation learning techniques have led to effective large-scale representations of EHR concepts along with knowledge graphs that empower downstream EHR studies. However, most existing methods require training with patient-level data, limiting their abilities to expand the training with multi-institutional EHR data. On the other hand, scalable approaches that only require summary-level data do not incorporate temporal dependencies between concepts. Methods: We introduce a DirectiOnal Medical Embedding (DOME) algorithm to encode temporally directional relationships between medical concepts, using summary-level EHR data. Specifically, DOME first aggregates patient-level EHR data into an asymmetric co-occurrence matrix. Then it computes two Positive Pointwise Mutual Information (PPMI) matrices to correspondingly encode the pairwise prior and posterior dependencies between medical concepts. Following that, a joint matrix factorization is performed on the two PPMI matrices, which results in three vectors for each concept: a semantic embedding and two directional context embeddings. They collectively provide a comprehensive depiction of the temporal relationship between EHR concepts. Results: We highlight the advantages and translational potential of DOME through three sets of validation studies. First, DOME consistently improves existing direction-agnostic embedding vectors for disease risk prediction in several diseases, for example achieving a relative gain of 5.5% in the area under the receiver operating characteristic (AUROC) for lung cancer. Second, DOME excels in directional drug-disease relationship inference by successfully differentiating between drug side effects and indications, correspondingly achieving relative AUROC gain over the state-of-the-art methods by 10.8% and 6.6%. Finally, DOME effectively constructs directional knowledge graphs, which distinguish disease risk factors from comorbidities, thereby revealing disease progression trajectories. The source codes are provided at https://github.com/celehs/Directional-EHRembedding.

60 APPLIED LIFE SCIENCES↗

Experimental Observation of Inertial Particles through Idealized Hydroturbine Distributor Geometry

To increase and maintain existing hydropower capacity within biological performance-based regulations, predictive simulation methods are needed that can reliably estimate the risk to fish passing through flow passage routes at hydropower facilities. One of the central challenges is to validate the software capabilities for simulating the trajectories, including collisions, of inertial particles against laboratory data. In this work, neutrally buoyant spherical- and rod-shaped beads were released upstream of laboratory-scale geometries representative of the distributor of a hydroturbine. The experimental campaign involved a test matrix of 24 configurations with variations in bead geometry, collision target geometry, flow speeds, and release locations. A total of more than 10,000 beads were recorded using high-speed video cameras and analyzed using particle tracking software. Collision rates from 1–7% were observed for the cylinder geometry and rates of 1–23% were observed for the vane array over the range of test configurations.

13 HYDRO ENERGY↗