Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “refrigerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Field-based AFDD for refrigerant undercharge in residential HVAC systems: enhancing reliability through false alarm mitigation

This study evaluated rule-based and machine learning (ML) based automated fault detection and diagnostics (AFDD) algorithms for detecting refrigerant undercharge faults in residential heating, ventilation, and air conditioning (HVAC) systems, using actual building data and a minimal set of features. The ML-based algorithms included Decision Tree (DT) and K-Nearest Neighbors (KNN). Both the rule-based and ML-based algorithms demonstrated the capability to detect refrigerant undercharge faults of -30% or more. Both types of algorithms exhibited false alarms before the implementation of a false alarm mitigation algorithm, which motivated the development of such a mitigation strategy. After applying the mitigation, false alarms were substantially reduced, with the rule-based algorithm decreasing to 0.6% and the ML-based algorithms reaching 0%, while maintaining strong detection performance. Although the rule-based algorithm initially showed lower performance compared to the ML-based algorithms, its detection accuracy improved after mitigation to a level comparable to the ML-based algorithms. These results confirm that combining false alarm mitigation with both rule-based and ML-based AFDD algorithms significantly enhances practical reliability while preserving robust fault detection capabilities. Furthermore, the findings demonstrate the potential for field deployment of these algorithms in residential HVAC systems and highlight the importance of minimizing false alarms.

False Alarm↗

Surface Acoustic Wave Sensors for Refrigerant Leak Detection: Compact, Inexpensive, Selective and Sensitive Sensors

Pacific Northwest National Laboratory (PNNL), in collaboration with Parker and Hannifin, is developing a compact, inexpensive, and highly sensitive and selective surface acoustic wave sensor coated with fluorophillic sorbent for detecting fluorocarbon leaks from HVAC systems. Having a highly effective sorbent sensitive to fluorocarbon refrigerant vapors provides a means to develop a sensing device for leak detection. Surface acoustic wave (SAW) sensors with a gas sensing film deposited between the delay lines or on the interdigital transducer have been used to detect gas and vapor molecules in harsh environments with high sensitivity. As part of this project, PNNL screened several sorbent materials that are shown to be selective towards fluorocarbon refrigerant (R32) molecule. The identified sorbent materials were synthesized, characterized, and tested towards R32 using various spectroscopic technique. Next, the sorbent material was coated on a SAW sensor as a thin film using vapor deposition and drop coating methods. The coated thin film was further characterized and tested towards the detection of pure R32 and R32 in ambient air at room temperature to demonstrate the SAW response towards R32 in presence of other competing gases and vapors in air.

42 ENGINEERING↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow With 25% Upsizing Allowance for Heating

This documentation focuses on a single end-use savings shape upgrade - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation and where 25% upsizing (or 125% of the original size) is allowed for heating in colder climates (i.e., heating dominant regions). This document will primarily discuss the additional changes to the sizing algorithm and modeling approach, while a comprehensive overview of the fundamental modeling methodology and background of the VRF HR DOAS upgrade, including applicability and other key assumptions can be found in the original documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System. To provide more context on the 25% upsizing algorithm, if the building is a cooling dominant (e.g., design cooling load higher than design heating load ), then the outdoor unit capacity of the VRF heat pump is sized based on the design cooling load. However, if the building is heating dominant, then this building is a candidate for the 25% upsizing allowance. Once the 25% upsizing is allowed, if the 25% upsized capacity (or 125% from the original size) represented with design condition exceeds the design heating load, then the design heating load is used for calculating the rated capacity of the outdoor unit. And if the 25% upsized capacity represented with the design condition does not exceed the design heating load, then the 25% upsized capacity represented with rated condition is used for the capacity of the outdoor unit while the remaining heating load is handled with the supplemental/backup electric resistance coil.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Virtual Pressure Sensor for Electronic Expansion Valve Control in a Vapor Compression Refrigeration System

Virtual sensor technology, which uses simulation models/algorithms to calculate a value to represent an unmeasured variable or replace a directly measured reading, has attracted many studies in the heating, ventilation, air conditioning and refrigeration (HVAC&R) industry. However, most virtual sensor technologies are developed for fault detection and diagnostics (FDD) purposes, which generally compare the virtual sensor values with actual measured values to detect if any fault occurred and identify the causes that led to the fault. It is rare to see studies focus on control performance of virtual sensors after substituting an actual sensor. This is particularly important for the system with no redundant sensor since a virtual sensor is the most effective way to operate the system in the desirable region when any sensor failure occurs. To address this gap, this paper develops a new virtual pressure sensor technology to substitute the actual pressure measurement for electronic expansion valve (EXV) control in a vapor compression refrigeration system by integrating compressor and valve characteristics. The control performance of this proposed virtual pressure sensor technology under various operating conditions is validated with experimental data. Closed loop EXV control simulations with the proposed virtual pressure sensor are conducted, and the results are analyzed.

47 OTHER INSTRUMENTATION↗

A ruthenium oxide thermometer for dilution refrigerators operating down to 5 mK

At the lowest temperatures achieved in dilution refrigerators, ruthenium oxide resistance thermometers often saturate and therefore lose their sensitivity. In an effort to extend the range of such temperature sensors, we built a thermometer which maintains sensitivity to 5 mK. A key component of this thermometer is an in situ radio frequency filter which is based on a modern rf absorption material. Here, we show that the use of such a filter is only effective when it is encased in the same rf-tight enclosure as the ruthenium oxide sensor. Our design delivers an attenuation level that is necessary to mitigate the effects of parasitic heating of a fraction of pW present in our circuit. Furthermore, we show that the likely origin of this parasitic heating is the black body radiation present within the experimental space of the refrigerator. We found that the equilibration time of the thermometer increases rapidly as the temperature is lowered; below 5 mK this thermometer becomes impractical because of the prohibitively long equilibration times.

47 OTHER INSTRUMENTATION↗

Methane liquefaction with an active magnetic regenerative refrigerator

This manuscript reports liquefaction of methane using an active magnetic regenerative refrigerator (AMRR). The AMRR used to cool from 285 K to 135 K has two identical regenerators fabricated with adjacent layers of four ferromagnetic refrigerants, each with sequentially lower Curie temperatures and lesser masses from hot to cold temperatures. The dual multilayer regenerators were assembled in opposition with a single cold region between them. For this set of experiments equal mass of helium gas was pumped through all layers of the regenerators during the two flow steps of the four-step AMR cycle. After successfully reaching 135 K, a compact condensing coil-fin tube heat exchanger (HEX) with a small storage vessel was mounted in the cold region of the dual regenerator assembly to be cooled during the hot-to-cold helium flow from alternatively demagnetized regenerators. The cold HEX was used to cool and liquefy a process stream of methane gas supplied at 295 K and different pressures in different runs. Further, by measuring time to liquefy a known volume of methane at three different pressures, cooling powers of the AMRR as a function of temperature were determined. The resultant data were compared to those predicted by the AMRR performance model. Conclusions from these experiments and suggestions for future work are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine learning based prediction of airflow maldistribution in air-to-refrigerant heat exchangers

Flow maldistribution is a common challenge in heat exchanger (HX) design and particularly important for air-to-refrigerant geometries where capacity losses can approach 65%. This has a major impact on central air conditioning systems, as compact duct design motivates the use of A-type HXs which are known to be affected by airflow maldistribution. Because velocity profiles are difficult to predict, components are often oversized leading to increased material cost, system footprint, and refrigerant charge. Several studies detail airflow maldistribution for individual HXs and packages, but findings cannot always be extrapolated to new designs. In this work, a machine learning (ML) based flow profile prediction framework is developed and applied to two common package configurations: (i) A-type and (ii) U-type HXs, across a broad range of HX geometries and flow rates. Porous media CFD simulations are validated against independent data for both package types as well as comprehensive in house measurements for a finless geometry with shape optimized non-round tubes, which validates the framework for new heat transfer surfaces. The ML models are trained on the porous media CFD simulations, predicting volumetric flow rate (VFR) within 1.1% and 1.9% with maximum relative L 2 norm errors of 0.48 and 0.65, respectively, while also delivering 10 5 speed up factor compared to full porous media CFD. HX level simulations show an up to 9% reduction in heat transfer from flow maldistribution, with greater losses occurring at smaller half apex angles. This framework enables rapid and highly accurate prediction of airflow maldistribution induced capacity degradation.

42 ENGINEERING↗

Chemically Tunable Aspect Ratio Control and Laser Refrigeration of Hexagonal Sodium Yttrium Fluoride Upconverting Materials

Hexagonal sodium yttrium fluoride with Na 3x Y 2-x F 6 stoichiometry (β-NaYF) is a promising material for luminescence upconversion applications due to the narrow crystal field splitting of the Yb(III) ion’s lower 2 F 7/2 manifold. However, growing single crystals of β-NaYF remains an outstanding challenge due to thermal expansion stresses that cause cracking during melt growth. Here, we demonstrate a novel hydrothermal synthesis of β-NaYF with the ability to tune the aspect ratio from microplatelets to microrods with aspect ratios that match computationally predicted cavity (Mie) resonances. These crystals have a root-mean-square roughness below 1 nm after calcination, which makes them ideal for optical cavities. The β-NaYF microcrystals are doped with 10% Yb(III) cations and are used to build optomechanical laser-refrigeration devices consisting of a hexagonal β-NaYF crystal located at the end of a cantilever. Laser refrigeration of these devices by >12.5 °C is observed using calibrated measurements of both the cantilever’s fundamental eigenfrequency and a Boltzmann fit to crystal field luminescence from the Yb(III) ions.

36 MATERIALS SCIENCE↗

Nanoscale Phase Separation and Large Refrigerant Capacity in Magnetocaloric Material LaFe 11.5 Si 1.5

Here, ferromagnetic transitions, the magnetocaloric effect, and the atomic-scale microstructure in an annealed bulk material of LaFe 11.5 Si 1.5 were investigated using magnetic measurements, Mössbauer spectroscopy, high-resolution X-ray diffraction analysis, and high-resolution transmission electron microscopy. The results provide evidence of the coexistence of two ferromagnetic phases with different Curie temperatures. The phase with a Curie temperature of 216 K corresponds to a Si-rich phase of a NaZn 13 -type structure with a small lattice volume, whereas the phase with a Curie temperature of 185 K corresponds to a Si-poor phase of a NaZn 13 -type structure with a large lattice volume. This phase coexistence is observed on a nanometer scale and it can account for inverse thermal hysteresis of the ferromagnetic transition in the Si-rich phase during warming. Furthermore, the phase coexistence helps the bulk material achieve a refrigeration capacity of 170 J kg -1 due to a combination of the magnetocaloric effect in each phase. It is determined that the magnetocaloric effect in the Si-rich and the Si-poor phase brings about a maximum of the total entropy change of -3.55 and -6.80 and J kg -1 K -1 at respective Curie temperatures, respectively. Fundamentally, the phase coexistence indicates coloring of Si atoms in the lattice of a NaZn 13 -type structure and can be attributed to nanoscale phase separation of a disordered precursor during annealing of the bulk material. The nanoscale phase separation may occur in other magnetocaloric materials, thus allowing for improvement of their refrigeration capacity.

36 MATERIALS SCIENCE↗

Interface and Thermophysical Properties of R 32 Refrigerant

Driven by the urgent demand for efficient cooling in microelectronics and advanced thermal management systems, difluoromethane (R32/CH 2 F 2 ) has emerged as a promising candidate owing to its favorable thermophysical properties, including high heat transfer efficiency and low viscosity. While bulk properties such as density, viscosity, and thermal conductivity have been widely studied, interfacial properties, including surface tension and interfacial thickness, remain comparatively underexplored, despite their importance in phase-transition dynamics. Here, we perform molecular dynamics (MD) simulations from 180 to 300 K using an optimized transferable force field for fluoropropenes with enhanced electrostatics to assess both bulk and interfacial behavior of R32. Simulations reproduced density within ±2.1%, viscosity within 3.05%, and thermal conductivity within 7.41% of NIST reference data. Heat capacities (C p and C v ) were predicted within 5%. For interfacial properties, surface tension trends were reproduced within 13.58% deviation, and the vapor–liquid coexistence curve closely matched reference data, yielding a critical temperature of 345.7 K (1.6% deviation) and a critical density of 0.397 g/cm 3 (6.4% deviation). Importantly, the vapor–liquid interface exhibited pronounced temperature-dependent broadening across the 180–290 K range. This behavior correlates with increasing molecular kinetic energy, reduction in intermolecular cohesive interactions, and a progressive loss of preferential dipole alignment, which collectively enhance thermal fluctuation amplitudes at elevated temperatures. These validated results provide predictive molecular-level insights, particularly for interfacial properties that remain less characterized. By reducing property prediction errors in key parameters such as critical temperature, this work provides reliable inputs for heat-exchanger and system models. Such correlations can support optimized component sizing, improved performance, and reduced refrigerant charge. Beyond R32, the methodology offers a transferable framework for blended and next-generation low-GWP refrigerants, contributing to sustainable thermal management aligned with the 2027 EU F-Gas regulation and 2030 Kigali Amendment.

Fluids↗

LCLS-II Helium Refrigeration System Commissioning Results

SLAC National Accelerator Laboratory has upgraded to LCLS-II, featuring a 4 GeV superconducting linear accelerator composed of 37 cryomodules and two large helium refrigeration systems with a cooling capacity of 4 kW at 2.0 K. The LCLS-II Helium Refrigeration System (HRS) consists of two compressor stations, each with a power of approximately 4.5 MW, two 4.5 K cold boxes, each with a power of 18 kW equivalent at 4.5 K, and two sets of cold compressors that can each produce a flow of 230 g/s at 31 mbar (2.0K). Performance tests of the HRS were meticulously planned and successfully carried out, with results demonstrating that it exceeded the process requirements for LCLS-II operations. This paper provides a detailed presentation of the LCLS-II HRS performance and the challenges encountered during the commissioning phase.

42 ENGINEERING↗

Compressor is A Sensor: A Universal Refrigerant Charge Fault Detection and Diagnostics Method Based on Pump Down Operation

The primary goal of this report is to develop a universal charge fault detection method that requires only a few experimental data with high prediction accuracy. Currently, pump-down operations is typical practices by HVAC technicians when they need to open the refrigerant circuit to make a repair. In addition, compressors have a built-in low-pressure cut-off protection function, and the compressor performance maps are commonly available from manufacturers. The new charge fault detection and diagnostics method innovatively utilizes the typical pump down operation, the compressor’s low-pressure cut-off protection, and the compressor performance map. It does not require any geometry information of heat exchangers, refrigerant lines, or charge buffers.

42 ENGINEERING↗

Implementation of a Web Interface to Display Real-Time Statistics of a Dilution Refrigerator

The purpose of the project is to communicate with a Bluefors control unit and extract data. The Bluefors control unit is a piece of experimental equipment that measures various different data points in a dilution refrigerator and stores them. The goal was to access the control unit using the websockets library in Python. After accessing the control unit, the goal was to export the data to a web page in HTML/CSS. The tools that were used changed throughout the project. Python was used to communicate with the Bluefors unit via JSON requests and JSON objects, then the Python hosted its own websocket server to act as a proxy server to allow for the web page to access the data. This was done to bypass SSL verification. Then, the web page, which was created using JavaScript, React, Next.js, and NodeJS, accesses the proxy server to import the data from the dilution refrigerator and display the values in real time on the page.

Rasheed, Hammad↗

MaxTech HPWH Using Ultra-low GWP Refrigerant

Heat pump water heaters (HPWHs) are a proven technology for water heating that has been commercialized. The adoption of HPWHs for domestic and commercial water heating is growing rapidly because of superior performance compared with that of alternative water heating methods. Whereas most existing systems use R-134a as a working refrigerant, significant interest exists for deploying low global warming potential refrigerants to minimize environmental impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

1 K refrigerator for the CLAS12 Polarized Target Design, Construction, and First Results

A dynamically polarized target of protons and deuterons in irradiated NH3 and ND3 will be employed with the CLAS12 detector system to explore the spin structure of the nucleon in Hall B at Jefferson Lab. This target will feature a versatile, horizontal 1 K refrigerator that has been constructed by a collaboration of Christopher Newport University, Old Dominion University, the University of Virginia, and the JLab Target Group. A description of the challenges involved with designing the target for the CLAS12 experiments and the collaboration’s solutions will be presented. These include a modular and compact design of the 1 K refrigerator and its ancillary equipment, as well as a novel mechanism for loading the target samples. Initial test results of the system will also be included.

Brock, James↗

Advantages of cryopumping with liquid hydrogen instead of helium refrigerators

Open loop hydrogen vaporizers and helium refrigerators are compared for operational complexity, installation and operating cost, and safety requirements. Data from two vacuum chambers using helium refrigerators are used to provide comparative data. In general, the use of hydrogen is attractive in the larger systems, even when extra safety precautions are taken. Emotional resistance to the use of hydrogen because of safety requirements is considered great. However, the experience gained in the handling of large quantities of cryogenics, particularly hydrogen and liquefied natural gases, should be considered in the design of open loop hydrogen cooling systems.

J.W. Anderson↗

Analysis of a combined refrigerator-generator space power system

Description of a single-shaft and a two-shaft rotating machinery arrangements using neon for application in a combined refrigerator-generator power system for space missions. The arrangements consist of combined assemblies of a power turbine, alternator, compressor, and cry-turbine with a single-stage radial-flow design. A computer program was prepared to study the thermodynamics of the dual system in the evaluation of its cryocooling/electric capacity and appropriate weight. A preliminary analysis showed that a two-shaft arrangement of the power- and refrigeration-loop rotating machinery provided better output capacities than a single-shaft arrangement, without prohibitive operating compromises.

Klann, J. L.↗