Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reference concentration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Microbial sensor system for the assessment of subsurface environments

A microbial sensor, system, and method that can be used to determine a chemical environment and/or substrate concentrations in anaerobic or aerobic environments, such as soils, sediments and ground waters, are disclosed. An exemplary system uses one or more (e.g., inert) measurement electrodes and a reference electrode. The reference electrode can include an electrode exposed to atmospheric oxygen (e.g., a cathode) or an electrode exposed to stable anaerobic or aerobic conditions. The exemplary microbial sensor system measures open-circuit voltage to characterize the chemical (oxidizing or reducing) environment and/or recovery voltage to measure substrate concentrations in the subsurface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microbial sensor system for the assessment of subsurface environments

A microbial sensor, system, and method that can be used to determine a chemical environment and/or substrate concentrations in anaerobic or aerobic environments, such as soils, sediments and ground waters, are disclosed. An exemplary system uses one or more (e.g., inert) measurement electrodes and a reference electrode. The reference electrode can include an electrode exposed to atmospheric oxygen (e.g., a cathode) or an electrode exposed to stable anaerobic or aerobic conditions. The exemplary microbial sensor system measures open-circuit voltage to characterize the chemical (oxidizing or reducing) environment and/or recovery voltage to measure substrate concentrations in the subsurface.

Burge, Scott R.↗

Black carbon aerosol number and mass concentration measurements by picosecond short-range elastic backscatter lidar

Abstract Black carbon aerosol emissions are recognized as contributors to global warming and air pollution. There remains, however, a lack of techniques to remotely measure black carbon aerosol particles with high range and time resolution. This article presents a direct and contact-free remote technique to estimate the black carbon aerosol number and mass concentration at a few meters from the emission source. This is done using the Colibri instrument based on a novel technique, referred to here as Picosecond Short-Range Elastic Backscatter Lidar (PSR-EBL). To address the complexity of retrieving lidar products at short measurement ranges, we apply a forward inversion method featuring radiometric lidar calibration. Our method is based on an extension of a well-established light-scattering model, the Rayleigh–Debye–Gans for Fractal-Aggregates (RDG-FA) theory, which computes an analytical expression of lidar parameters. These parameters are the backscattering cross-sections and the lidar ratio for black carbon fractal aggregates. Using a small-scale Jet A-1 kerosene pool fire, we demonstrate the ability of the technique to quantify the aerosol number and mass concentration with centimetre range-resolution and millisecond time-resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Annual Technology Baseline: The 2020 Electricity Update

Consistent cost and performance data for various electricity generation technologies can be difficult to find and may change frequently for certain technologies. With the Annual Technology Baseline (ATB), the National Renewable Energy Laboratory annually provides an organized and centralized set of such cost and performance data. The ATB uses the best information from the Department of Energy national laboratories' renewable energy analysts. The ATB has been reviewed by experts and it includes the following electricity generation technologies: land-based wind, offshore wind, utility-scale solar photovoltaics (PV), commercial-scale solar PV, residential-scale solar PV, concentrating solar power, geothermal power, hydropower, utility-scale battery storage. EIA data for coal, natural gas, nuclear, and conventional biopower are included for reference. This webinar presentation introduces the 2020 update to the ATB Electricity data and documentation.

capacity factor↗

Synchrotron Microanalytical Characterization and K/Ar Dating of the GL-O-1 Glauconite Reference Material at the Single Pellet Scale and Reassessment of the Age of Visually Mature Pellets

The K/Ar chronology of glauconite pellets is a long-used method for directly dating marine sedimentary deposits. Many papers have explored the processes that form glauconite and the factors that lead to greater reliability in the ages. Although K/Ar ages of glauconite are generally in agreement with other measures of stratigraphic age, there are examples of occurrences with ages too old and examples with ages too young. This paper seeks to build on the accumulated knowledge of glauconite, using synchrotron radiation to non-destructively characterize individual pellets and then consecutively measure the argon and potassium to obtain a K/Ar age. This strategy provides the advantage of measurements on a single aliquot while avoiding recoil loss of 40 Ar in the nuclear reactor during irradiation for 40 Ar/ 39 Ar dating. We have used the glauconite reference material GL-O-1 to showcase several non-destructive methods for evaluating the maturity of individual pellets. In our argon measurements, we have found that the radiogenic argon concentration of large bulk samples underestimates the values for individual visually mature pellets, and we determined a K/Ar age of 101.0 ± 0.3 Ma (1σ SEM), M.S.W.D. 0.54 from 15 of 16 visually mature individual pellets. This age is 6% older than the reference value of 95.03 ± 1.11 Ma (1σ), and it is in good agreement with constraints from the U-Pb dating of volcanic minerals near the Albian–Cenomanian boundary.

36 MATERIALS SCIENCE↗

Inhalation of Trace Metals in Secondhand and Thirdhand Tobacco Smoke Can Result in Increased Health Risks

Here, the presence of toxic metals in tobacco smoke is well documented. However, few studies have quantified trace metals in secondhand smoke (SHS) and thirdhand smoke (THS). Their presence in indoor air can contribute to nonsmokers’ exposures and health effects. In this study, emission and deposition rates of toxic trace metals were determined, and their airborne concentration in typical indoor scenarios was predicted. PM 2.5 was collected on Teflon-coated filters at various times following a smoking event in a room-sized chamber over a 43 h period. The concentration of 28 trace metals was determined by extraction and analysis using inductively coupled plasma-triple quadrupole-mass spectrometry (ICP-QQQ-MS). Emission and indoor deposition rates of cadmium, arsenic, chromium, manganese, beryllium and selenium were determined, and used to predict concentrations expected in a smokers’ home and a smoking bar. In most of the considered scenarios, average indoor concentrations of Cd, As, and Cr exceeded their corresponding cancer risk thresholds and, in some cases, also noncancer reference exposure levels, more than 3 h after smoking ended. The fraction of cadmium that remained airborne was significantly higher than those of other metal traces and that of PM 2.5 , suggesting an association of Cd traces with small particles.

60 APPLIED LIFE SCIENCES↗

Chemical bonding in americium oxides probed by X-ray spectroscopy

The electronic structure and the chemical state in Am binary oxides and Am-doped UO 2 were studied by means of X-ray absorption spectroscopy at shallow Am core (4d and 5d) edges. In particular, the Am 5f states were probed and the nature of their bonding to the oxygen states was analyzed. The interpretation of the experimental data was supported by the Anderson impurity model (AIM) calculations which took into account the full multiplet structure due to the interaction between 5f electrons as well as the interaction with the core hole. The sensitivity of the branching ratio of the Am 4d 3/2 and 4d 5/2 X-ray absorption lines to the chemical state of Am was shown using Am binary oxides as reference systems. The observed ratio for Am-doped UO 2 suggests that at least at low Am concentrations, americium is in the Am(III) state in the UO 2 lattice. To confirm the validity of the applied AIM approach, the analysis of the Am 4f X-ray photoelectron spectra of AmO 2 and Am 2 O 3 was also performed which revealed a good agreement between experiment and calculations. As a whole, AmO 2 can be classified as the charge-transfer compound with the 5f occupancy (n ƒ ) equal to 5.73 electrons, while Am 2 O 3 is rather a Mott–Hubbard system with n ƒ = 6.05.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solvent-mediated contaminant removal from plastic waste using thermodynamic modeling

Plastics recycling is hindered by the compositional complexity of plastic waste, which can include numerous polymer components as well as low concentrations of additives and non-intentionally added substances. These latter small-molecule species, which we collectively refer to as contaminants, can harm human health and will build up in recycled plastic causing environmental and downstream processing challenges if not removed. In this work, we present molecular modeling approaches using the COnductor-like Screening MOdel for Real Solvents (COSMO-RS) to guide the selection of solvents that are capable of removing targeted contaminants from plastic waste. By considering the thermodynamic partitioning of contaminant species between a solvent phase and polymer phase, we identify guidelines for solvent selection to promote either the low-temperature extraction of contaminants from plastic waste or the removal of contaminants as part of a dissolution-based plastics recycling process. We present four case studies to illustrate the application of the computational approach to the removal of brominated flame retardants, phthalates, and selected perfluoroalkyl substances, and compare to both literature and newly collected experimental data to illustrate model prediction accuracy. Furthermore, the case studies highlight the capability of the modeling approach to help design recycling processes that explicitly account for contaminant removal, thereby increasing product purity during dissolution-based recycling or facilitating chemical recycling of contaminant-free plastics.

Zhou, Panzheng [University of, Wisconsin, Madison,↗

Ultrafast carrier dynamics in terahertz photoconductors and photomixers: beyond short-carrier-lifetime semiconductors

Abstract Efficient terahertz generation and detection are a key prerequisite for high performance terahertz systems. Major advancements in realizing efficient terahertz emitters and detectors were enabled through photonics-driven semiconductor devices, thanks to the extremely wide bandwidth available at optical frequencies. Through the efficient generation and ultrafast transport of charge carriers within a photo-absorbing semiconductor material, terahertz frequency components are created from the mixing products of the optical frequency components that drive the terahertz device – a process usually referred to as photomixing. The created terahertz frequency components, which are in the physical form of oscillating carrier concentrations, can feed a terahertz antenna and get radiated in case of a terahertz emitter, or mix with an incoming terahertz wave to down-convert to DC or to a low frequency photocurrent in case of a terahertz detector. Realizing terahertz photoconductors typically relies on short-carrier-lifetime semiconductors as the photo-absorbing material, where photocarriers are quickly trapped within one picosecond or less after generation, leading to ultrafast carrier dynamics that facilitates high-frequency device operation. However, while enabling broadband operation, a sub-picosecond lifetime of the photocarriers results in a substantial loss of photoconductive gain and optical responsivity. In addition, growth of short-carrier-lifetime semiconductors in many cases relies on the use of rare elements and non-standard processes with limited accessibility. Therefore, there is a strong motivation to explore and develop alternative techniques for realizing terahertz photomixers that do not rely on these defect-introduced short-carrier-lifetime semiconductors. This review will provide an overview of several promising approaches to realize terahertz emitters and detectors without short-carrier-lifetime semiconductors. These novel approaches utilize p-i-n diode junctions, plasmonic nanostructures, ultrafast spintronics, and low-dimensional materials to offer ultrafast carrier response. These innovative directions have great potentials for extending the applicability and accessibility of the terahertz spectrum for a wide range of applications.

36 MATERIALS SCIENCE↗

A bibliography on the search for extraterrestrial intelligence

This report presents a uniform compilation of works dealing with the search for extraterrestrial intelligence. Entries are by first author, with cross-reference by topic index and by periodical index. This bibliography updates earlier bibliographies on this general topic while concentrating on research related to listening for signals from extraterrestrial intelligence.

Mallove, E. F.↗

Isoelectric focusing of proteins and peptides

Egg-white solution was chosen as the reference solution in order to assess the effects of operational parameters (voltage, flow rate, ampholine pH range and concentration, and protein concentration) of the RIEF apparatus on protein resolution. Topics of discussion include: (1) comparison of RIEF apparatus to conventional IEF techniques (column and PAG) with respect to resolution and throughput; (2) peptide and protein separation (AHF, Thymosin - Fraction 5, vasoactive peptide, L-asparaginase and ACP); and (3) detection of peptides - dansyl derivatives of amino acids and peptides, post-focusing fluorescent labeling of amino acids, peptides and proteins, and ampholine extraction from focused gels.

Egen, N.↗

High temperature durable catalyst development

A program has been carried out to develop a catalytic reactor capable of operation in environments representative of those anticipated for advanced automotive gas turbine engines. A reactor consisting of a graded cell honeycomb support with a combination of noble metal and metal oxide catalyst coatings was built and successfully operated for 1000 hr. At an air preheat temperature of 740 K and a propane/air ratio of 0.028 by mass, the adiabatic flame temperature was held at about 1700 K. The graded cell monolithic reaction measured 5 cm in diameter by 10.2 cm in length and was operated at a reference velocity of 14.0 m/s at 1 atm. Measured NOx levels remained below 5 ppm, while unburned hydrocarbon concentrations registered near zero and carbon monoxide levels were nominally below 20 ppm.

Snow, G. C.↗

Methods of reducing energy consumption of the oxidant supply system for MHD/steam power plants

An in-depth study was conducted to identify possible improvements to the oxidant supply system for combined cycle MHD power plants which would lead to higher thermal efficiency and reduction in the cost of electricity, COE. Results showed that the oxidant system energy consumption could be minimized when the process was designed to deliver a product O2 concentration of 70 mole percent. The study also led to the development of a new air separation process, referred to as liquid pumping and internal compression. MHD system performance calculations show that the new process would permit an increase in plant thermal efficiency of 0.6 percent while allowing more favorable tradeoffs between magnetic energy and oxidant system capacity requirements.

A. J Juhasz↗

Methods of reducing energy consumption of the oxidant supply system for MHD/steam power plants

An in-depth study was conducted to identify possible improvements to the oxidant supply system for combined cycle MHD power plants which would lead to higher thermal efficiency and reduction in the cost of electricity, COE. Results showed that the oxidant system energy consumption could be minimized when the process was designed to deliver a product O2 concentration of 70 mole percent. The study also led to the development of a new air separation process, referred to as 'liquid pumping and internal compression'. MHD system performance calculations show that the new process would permit an increase in plant thermal efficiency of 0.6 percent while allowing more favorable tradeoffs between magnetic energy and oxidant system capacity requirements.

Juhasz, A. J.↗

Observations of condensation nuclei in the 1987 airborne Antarctic ozone experiment

The condensation nucleus counter (CNC) flown of the NASA ER-2 in the Airborne Antarctic Ozone Experiment provides a measurement of the number mixing ratio of particles which can be grown by exposure to supersaturated n-butyl alcohol vapor to diameters of a few microns. Such particles are referred to as condensation nuclei (CN). The ER-2 CNC was calibrated with aerosols of known size and concentration and was found to provide an accurate measure of the number concentration of particles larger than about 0.02 micron. Since the number distribution of stratospheric aerosols is usually dominated by particles less than a few tenths of micron in diameter, the upper cutoff of the ER-2 CNC has not been determined experimentally. However, theory suggests that the sampling and counting efficiency should remain near one for particles as large as 1 micron in diameter. Thus, the CN mixing ratio is usually a good measure of the mixing ratio of submicron particles.

Wilson, J. C.↗

Critical needs of fringe-order accuracies in two-color holographic interferometry

Requirements for the fringe order accuracy in two-color holographic interferometry are discussed with reference to crystal growth. A simple test cell (rectangular parallelepiped) containing a fluid is considered. The temperature and concentration variations are related to the fringe orders from the two interference patterns, and the uncertainties in the fringe orders are related to errors in the temperature and concentration determination. The formulation developed here is applied to the particular case of an aqueous solution of triglycerine sulfate as an example.

Vikram, C. S.↗

Reevaluation of the NOAA/CMDL carbon monoxide reference scale and comparisons with CO reference gases at NASA-Langley and the Fraunhofer Institut

The carbon monoxide (CO) reference scale created by the National Oceanic and Atmospheric Administration/Climate Monitoring and Diagnostics Laboratory (NOAA/CMDL) is used to quantify measurements of CO in the atmosphere, calibrate standards of other laboratories and to otherwise provide reference gases to the community measuring atmospheric CO. This reference scale was created based upon a set of primary standards prepared by gravimetric methods at CMDL and has been propagated to a set of working standards. In this paper we compare CO mixing ratios assigned to the working standards by three approaches: (1) calibration against the original gravimetric standards, (2) calibration using only working standards as the reference gas, and (3) calibration against three new gravimetric standards prepared to CMDL. The agreement between these values was typically better than 1%. The calibration histories of CMDL working standards are reviewed with respect to expected rates of CO change in the atmosphere. Using a Monte Carlo approach to simulate the effect of drifting standards on calculated mixing ratios, we conclude that the error solely associated with the maintenance of standards will limit the ability to detect small CO changes in the atmosphere. We also report results of intercalibration experiments conducted between CMDL and the Diode Laser Sensor Group (DACOM) at the NASA Langley Research Center (Hampton, Virginia), and CMDL and the Fraunhofer-Institut (Garmisch-Partenkirchen, Germany). Each laboratory calibrated several working standards for CO using their reference gases, and these results were compared to calibrations conducted by CMDL. The intercomparison of eight standards (CO concentrations between approximately 100 and approximately 165 ppb) by CMDL and NASA agreed to better than +/- 2%. The calibration of six standards (CO concentrations between approximately 50 and approximately 210 ppb) by CMDL and the Fraunhofer-Institut agreed to within +/- 2% for four standards, and to within +/- 5% for all six standards.

Novelli, P. C.↗

Precision orbit determination using TOPEX/Poseidon TDRSS observations

The TOPEX/Poseidon (T/P) Mission carries a variety of packages to support experimental, precision and operational orbit determination. Included are a GPS transponder, laser retro-reflectors, the French-developed Doppler Orbitography and Radiopositioning Integrated by Satellite (DORIS) Doppler tracking system and a Tracking Data Relay Satellite System (TDRSS) transponder. Presently, TDRSS tracking is used for operational orbit support and is processed with force and measurement modeling consistent with this purpose. However, the low noise and extensive geographical coverage of the TDRSS/TOPEX data allows an assessment of TDRSS Precision Orbit Determination (POD) capabilities by comparison to the T/P precision orbit determination. The Geodynamics (GEODYN) Orbit Determination System is used to process laser and DORIS data to produce the precision orbits for the T/P Project. GEODYN has been modified recently to support the TDRSS observations. TDRSS data analysis can now benefit from the extensive force modeling and reference frame stability needed to meet the orbit determination (OD) goals of the T/P Mission. This analysis has concentrated on the strongest of the TDRSS measurement types, its two-way average range rate. Both the TDRSS and T/P orbits have been assessed in combination with the global satellite laser ranging (SLR) data and by themselves. These results indicate that significant improvement in the TDRSS ephemerides is obtained when the T/P orbit is well determined by SLR, and the TDRSS/TOPEX Doppler link is used to position TDRSS. Meter-level TDRSS positioning uncertainty is achieved using this approach. When the TDRSS orbit location is provided by this approach, the two-way range rate from a single TDRSS (i.e. West only) can provide T/P orbits with sub-meter radial accuracies and two meter RMS total position agreement with SLR defined orbits. These preliminary results indicate improved modeling of the TDRSS measurement through the elimination of heretofore neglected effects like the motion of the T/P TDRSS antenna and improved modeling of ionospheric and atmospheric refractive effects, and the inclusion of TDRSS East in the analysis are warranted. Through these improvements, TDRSS can make a significant contribution to geopotential recovery and precision OD.

Teles, Jerome↗