Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “range measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Improved Measurement of Dispersion in an Optical Fiber

An improved method of measuring chromatic dispersion in an optical fiber or other device affords a lower (relative to prior such methods) limit of measurable dispersion. This method is a modified version of the amplitude-modulation (AM) method, which is one of the prior methods. In comparison with the other prior methods, the AM method is less complex. However, the AM method is limited to dispersion levels . 160 ps/nm and cannot be used to measure the symbol of the dispersion. In contrast, the present modified version of the AM method can be used to measure the symbol of the symbol of the dispersion and affords a measurement range from about 2 ps/nm to several thousand ps/nm with a resolution of 0.27 ps/nm or finer. The figure schematically depicts the measurement apparatus. The source of light for the measurement is a laser, the wavelength of which is monitored by an optical spectrum analyzer. A light-component analyzer amplitude-modulates the light with a scanning radio-frequency signal. The modulated light is passed through a buffer (described below) and through the device under test (e.g., an optical fiber, the dispersion of which one seeks to measure), then back to the light-component analyzer for spectrum analysis. Dispersion in the device under test gives rise to phase shifts among the carrier and the upper and lower sideband components of the modulated signal. These phase shifts affect the modulation-frequency component of the output of a photodetector exposed to the signal that emerges from the device under test. One of the effects is that this component goes to zero periodically as the modulation frequency is varied.

Huang, Shouhua↗

Conductance measurement circuit with wide dynamic range

A conductance measurement circuit to measure conductance of a solution under test with an output voltage proportional to conductance over a 5-decade range, i.e., 0.01 uS to 1000 uS or from 0.1 uS to 10,000 uS. An increase in conductance indicates growth, or multiplication, of the bacteria in the test solution. Two circuits are used each for an alternate half-cycle time periods of an alternate squarewave in order to cause alternate and opposite currents to be applied to the test solution. The output of one of the two circuits may be scaled for a different range optimum switching frequency dependent upon the solution conductance and to enable uninterrupted measurement over the complete 5-decade range. This circuitry provides two overlapping ranges of conductance which can be read simultaneously without discontinuity thereby eliminating range switching within the basic circuitry. A VCO is used to automatically change the operating frequency according to the particular value of the conductance being measured, and comparators indicate which range is valid and also facilitate computer-controlled data acquisition. A multiplexer may be used to monitor any number of solutions under test continuously.

Mount, Bruce E.↗

Lidar stratospheric ozone measurements at the observatoire de Haute Provence (France)

Strastospheric ozone monitoring is of particular importance to confirm present day theories predicting a maximal ozone depletion, due to chlorofluorocarbon emission, in the 35 to 45 km altitude range. Measurements presently rely on both ground based and satellite-borne passive experiments. Such systems have been recently shown to have intrinsic limitations mainly due to atmospheric aerosol presence and calibration problems. During the last few years, active lidar profiling of the ozone vertical distribution by the Differential Absorption Laser technique (DIAL) in the UV wavelength range has been developed using two different laser sources: a Nd-YAG pumped dye laser which enables a large tuning range of the UV emitted wavelengths; and exciplex laser sources using xenon chloride as an active medium and emitting at 308 nm, the off wavelength being usually generated by Raman shifting techniques. Advantages and limitations of using both of these systems are briefly discussed.

Godin, S.↗

Critical configurations (determinantal loci) for range and range difference satellite networks

The observational modes of Geometric Satellite Geodesy are discussed. The geometrical analysis of the problem yielded a regression model for the adjustment of the observations along with a suitable and convenient metric for the least-squares criterion. The determinantal loci (critical configurations) for range networks are analyzed. An attempt is made to apply elements of the theory of variants for this purpose. The use of continuously measured range differences for loci determination is proposed.

Tsimis, E.↗

The complete polarization state of a storm of millisecond bursts from Jupiter

Normal bursts with right-hand (RH) elliptical polarization, millisec S-bursts with RH elliptical polarization, and S-bursts with left-hand (LH) elliptical polarization, are presently observed in an extended storm of decametric radiation from Jupiter's Io-related source, 'Io-B'. This radiation was 100 percent elliptically polarized at all frequencies in the 14-31 MHz range measured. For an 80-min period, there was a mixture of RH and LH elliptically polarized S bursts in the 14-20 MHz range. An examination of the origin of a Faraday-rotation difference between RH and LH elliptical bursts suggests that some Faraday rotation occurs in the Io torus; this was traversed more centrally by the LH bursts from the southern auroral zone than the HH bursts from the northern auroral zone.

Dulk, G. A.↗

Improved Estimate of Phobos Secular Acceleration from MOLA Observations

We report on new observations of the orbital position of Phobos, and use them to obtain a new and improved estimate of the rate of secular acceleration in longitude due to tidal dissipation within Mars. Phobos is the inner-most natural satellite of Mars, and one of the few natural satellites in the solar system with orbital period shorter than the rotation period of its primary. As a result, any departure from a perfect elastic response by Mars in the tides raised on it by Phobos will cause a transfer of angular momentum from the orbit of Phobos to the spin of Mars. Since its discovery in 1877, Phobos has completed over 145,500 orbits, and has one of the best studied orbits in the solar system, with over 6000 earth-based astrometric observations, and over 300 spacecraft observations. As early as 1945, Sharpless noted that there is a secular acceleration in mean longitude, with rate (1.88 + 0.25) 10(exp -3) degrees per square year. In preparation for the 1989 Russian spacecraft mission to Phobos, considerable work was done compiling past observations, and refining the orbital model. All of the published estimates from that era are in good agreement. A typical solution (Jacobson et al., 1989) yields (1.249 + 0.018) 10(exp -3) degrees per square year. The MOLA instrument on MGS is a laser altimeter, and was designed to measure the topography of Mars. However, it has also been used to make observations of the position of Phobos. In 1998, a direct range measurement was made, which indicated that Phobos was slightly ahead of the predicted position. The MOLA detector views the surface of Mars in a narrow field of view, at 1064 nanometer wavelength, and can detect shadows cast by Phobos on the surface of Mars. We have found 15 such serendipitous shadow transit events over the interval from xx to xx, and all of them show Phobos to be ahead of schedule, and getting progressively farther ahead of the predicted position. In contrast, the cross-track positions are quite close to the predicted values. Assuming that the along-track discrepancy is small enough that we can linearize the corrections, we model the mean orbital longitude as a quadratic function of time, and solve for corrections to the constant, linear, and quadratic terms. The time span of the recent observations is insufficient to properly resolve this issue alone, but when the 127 years of prior observations are added, we find a solution which reduces misfit to the new observations considerably, and makes no significant change to the fit to earlier observations. Our estimate for the secular acceleration term is (1.367 + 0.006) degrees per square year. The corresponding rate of energy dissipation is 3.34 MW. From a geophysical perspective, a more interesting parameter than the secular acceleration itself is the tidal lag angle, or tidal quality factor Q, for Mars. Unfortunately, the limiting error source in that determination is remaining uncertainty in the tidal Love numbers at harmonic degrees 2,3, and even 4. Until those parameters are better constrained, improvement in the orbital model of Phobos will not provide corresponding benefits for understanding the interior of Mars.

Bills, Bruce↗

An Empirical State Error Covariance Matrix Orbit Determination Example

State estimation techniques serve effectively to provide mean state estimates. However, the state error covariance matrices provided as part of these techniques suffer from some degree of lack of confidence in their ability to adequately describe the uncertainty in the estimated states. A specific problem with the traditional form of state error covariance matrices is that they represent only a mapping of the assumed observation error characteristics into the state space. Any errors that arise from other sources (environment modeling, precision, etc.) are not directly represented in a traditional, theoretical state error covariance matrix. First, consider that an actual observation contains only measurement error and that an estimated observation contains all other errors, known and unknown. Then it follows that a measurement residual (the difference between expected and observed measurements) contains all errors for that measurement. Therefore, a direct and appropriate inclusion of the actual measurement residuals in the state error covariance matrix of the estimate will result in an empirical state error covariance matrix. This empirical state error covariance matrix will fully include all of the errors in the state estimate. The empirical error covariance matrix is determined from a literal reinterpretation of the equations involved in the weighted least squares estimation algorithm. It is a formally correct, empirical state error covariance matrix obtained through use of the average form of the weighted measurement residual variance performance index rather than the usual total weighted residual form. Based on its formulation, this matrix will contain the total uncertainty in the state estimate, regardless as to the source of the uncertainty and whether the source is anticipated or not. It is expected that the empirical error covariance matrix will give a better, statistical representation of the state error in poorly modeled systems or when sensor performance is suspect. In its most straight forward form, the technique only requires supplemental calculations to be added to existing batch estimation algorithms. In the current problem being studied a truth model making use of gravity with spherical, J2 and J4 terms plus a standard exponential type atmosphere with simple diurnal and random walk components is used. The ability of the empirical state error covariance matrix to account for errors is investigated under four scenarios during orbit estimation. These scenarios are: exact modeling under known measurement errors, exact modeling under corrupted measurement errors, inexact modeling under known measurement errors, and inexact modeling under corrupted measurement errors. For this problem a simple analog of a distributed space surveillance network is used. The sensors in this network make only range measurements and with simple normally distributed measurement errors. The sensors are assumed to have full horizon to horizon viewing at any azimuth. For definiteness, an orbit at the approximate altitude and inclination of the International Space Station is used for the study. The comparison analyses of the data involve only total vectors. No investigation of specific orbital elements is undertaken. The total vector analyses will look at the chisquare values of the error in the difference between the estimated state and the true modeled state using both the empirical and theoretical error covariance matrices for each of scenario.

Frisbee, Joseph H., Jr.↗

Geoscience Laser Altimeter System (GLAS) for the ICESat Mission

The Geoscience Laser Altimeter System (GLAS) is a new generation lidar and is the primary science payload for NASA's ICESat Mission. The GLAS design combines a 10 cm precision surface lidar with a sensitive dual wavelength cloud and aerosol lidar. GLAS will precisely measure the heights of the Earth's polar ice sheets, establish a grid of accurate height profiles of the Earth's land topography, and profile the vertical distribution of clouds and aerosols on a global scale. GLAS will be integrated onto a small spacecraft built by Ball Aerospace, and will be launched into a polar orbit with a 590-630 km altitude at an inclination of 94 degrees. ICESat is is currently planned to launch in winter 2002/03 and GLAS is designed to operate continuously in space for a minimum of 3 years. GLAS will measure the vertical distance from orbit to the Earth's surface with pulses from a ND:YAG laser at a 40 Hz rate. Each 6 nsec wide 1064 nm laser pulse is used to produce a single range measurement. On the surface, the laser footprints have 66 m diameter and approx. 170 m center-center spacings. The GLAS receiver uses a I m diameter telescope to detect laser backscatter and a Si APD to detect the 1064 nm signals. The detector's output is sampled by a digital ranging receiver, which records each transmitted pulse and surface echo waveform with 1 nsec (15 cm) resolution. Each echo pulse is digitized and is reported to ground with a record length of from 200 to 544 samples, depending on the spacecraft's location . The GLAS location and epoch times are measured by a precision GPS receiver carried on the ICESat spacecraft. Initial processing of the echo waveforms within GLAS permits discrimination between cloud and surface echoes for selecting appropriate waveform samples. This selection is guided by an on-board DEM which is used to set the boundaries for the echo pulse search algorithm. Subsequent ground-based echo pulse analysis, along with GPS-based clock frequency estimates, permit final determination of the range to the surface, degree of pulse spreading, and vertical distribution of any vegetation illuminated by the laser. Accurate knowledge of the laser beam's pointing angle is needed to prevent height biases when measuring over tilted surfaces, such as near the boundaries of ice sheets. For surfaces with 2 deg. slopes, knowledge of pointing angle of the beam's centroid angle to better than 10 urad is needed. GLAS uses a stellar reference system (SRS) to measure the pointing angle of each laser firing relative to inertial space. The SRS uses a high precision star camera oriented toward local zenith and a gyroscope to determine the inertial orientation of the SRS optical bench. The far field pattern of each laser is measured pulse relative to the star camera with a laser reference system (LRS). GLAS will also measure the vertical distributions of clouds and aerosols by recording the vertical profiles of laser pulse backscatter at both 1064 and 532 nm. The 1064 rim measurements use the Si APD detector and will be used to measure the height and echo pulse shape from thicker clouds. The lidar receiver at 532 nm uses a narrow bandwidth etalon filter and highly sensitive photon counting detectors. The 532 nm backscatter profiles will be used to measure the vertical extent of thinner clouds and the atmospheric boundary layer. The GLAS instrument component development is complete and the instrument is undergoing final testing and qualification at NASA-Goddard. The GLAS "as-built" characteristics and its expected measurement performance will be discussed.

Abshire, James B.↗

Wetting Angles and Surface Tension of Ge(1-x)Si(x) Melts on Different Substrate Materials

The wetting angles and the surface tension of Ge(1-x)Si(x) melts (0.02 less than x less than 0.13) have been measured on various substrate materials using the sessile drop technique. Fused quartz, sapphire, SiC, glassy carbon, pBN, AIN, and Si3N4 have been used as substrates. The highest and most stable wetting angles were found for pBN substrates with 164 +/- 8 deg., either under forming gas with an additional carbon getter in the system or under active vacuum. The surface tension measurements resulted in a value of +2.2 x 10(exp -3) N/m.at%Si for the concentration dependence delta(gamma)/(delta)C. For the composition range measured, the temperature dependence (delt)gamma/(delta)T showed values similar to those of pure Ge, on average -0.07 x 10(exp -3) N/mK.

Croell, A.↗

The Geoscience Laser Altimeter System (GLAS) for the ICESAT Mission

Accurate measurements of surface heights and atmospheric backscatter have been demonstrated with the SLA, MOLA and LITE space lidar. Recent MOLA measurements of the Mars surface have 40 cm resolution and have reduced the global uncertainty in Mars topography from a few km to approx. 10 m. GLAS is a next generation lidar being developed as part of NASA's Icesat Mission for Earth orbit . The GLAS design combines a 10 cm precision surface lidar with a sensitive dual wavelength cloud and aerosol lidar. GLAS will precisely measure the heights of the Earth's polar ice sheets, determine the height profiles of the Earth's land topography, and profile the vertical backscatter of clouds and aerosols on a global scale. GLAS will fly on a small dedicated spacecraft in a polar orbit at 598 km altitude with an inclination of 94 degrees. GLAS is scheduled to launch in summer 2001 and to operate continuously for a minimum of 3 years with a goal of 5 years. The primary mission for GLAS is to measure the seasonal and annual changes in the heights of the Greenland and Antarctic ice sheets. GLAS will measure the vertical distance to the ice sheet from orbit with 1064 nm pulses from a Nd:Yag laser at 40 Hz. Each 5 nsec wide laser pulse is used for a single range measurement. When over land GLAS will profile the heights of the topography and vegetation. The GLAS receiver uses a I m diameter telescope and a Si APD detector. The detector signal is sampled by an all digital receiver which records each surface echo waveform with I nsec resolution and a stored echo record lengths of either 200, 400, or 600 samples. Analysis of the echo waveforms within the instrument permits discrimination between cloud and surface echoes. Ground based echo analysis permits precise ranging, determining the roughness or slopes of the surface as well as the vertical distributions of vegetation illuminated by the laser, Errors in knowledge of the laser beam pointing angle can bias height measurements of sloped surfaces. For surfaces with 2 deg. slopes, knowledge of pointing angle of the beam centroid to about 8 urad is required to achieve 10 cm height accuracy. GLAS uses a stellar reference system (SRS) to determine the pointing angle of each laser firing relative to inertial space. The SRS uses a high precision star camera oriented toward local zenith whose measurements are combined with a gyroscope to determine the inertial orientation of the SRS optical bench. The far field pattern of each laser pulse is measured with a laser reference system (LRS). Optically measuring each laser far field pattern relative to the star camera and gyroscope permits the angular offsets of each laser pulse to be determined. GLAS will also determine the vertical distributions of clouds and aerosols by measuring atmospheric backscatter profiles at both 1064 and 532 nm. The 1064 nm measurements use an analog detector and profile the height and vertical structure of thicker clouds. Measurements at 532 nm use new highly sensitive photon counting detectors, and measure the height distributions of very thin clouds and aerosol layers. With averaging these can be used to determine the height of the planetary boundary layer. The instrument design and expected performance will be discussed.

Abshire, James B.↗

Ultrasonic attenuation in superconducting molybdenum-rhenium alloys.

Investigation of longitudinal sound attenuation in superconducting Mo-Re alloys as a function of temperature, magnetic field, and frequency. Evaporated thin film CdS transducers were used for the measurements at frequencies up to 3 GHz. The normal state attenuation coefficient was found to be proportional to the square of frequency over this frequency range. Measurements in zero magnetic field yielded a value of the energy gap parameter close to the threshold value of 3.56 kTc, appropriate to a weakly coupled dirty limit superconductor.

Ashkin, M.↗

Passive microwave remote sensing of soil moisture - The effect of tilled row structure

The tilled row structure in agricultural fields is one of the important factors affecting observations of microwave emission from such fields. Measurements of this effect were performed with L-band and X-band radiometers mounted on a mobile truck on a bare 40 m x 45 m row tilled field; the soil moisture content during measurements ranged from 10 to 30% by dry weight. Results showed that the variations of the antenna temperatures with incident angle changed with the azimuth angle measured from the row direction. It is found that the observed difference between horizontally and vertically polarized antenna temperatures is due to the change in the local angle of field emission within the antenna field of view caused by the large-scale row structure.

Wang, J. R.↗

Analysis and prediction of ocean swell using instrumented buoys

During the period 20-23 September 1990, the remnants of Supertyphoon Flo moved into the central North Pacific Ocean with sustained wind speeds of 28 m/s. The strong wind and large fetch area associated with this storm generated long-period swell that propagated to the west coast of North America. National Data Buoy Center moored-buoy stations, located in a network that ranged from the Gulf of Alaska to the California Bight, provided wave spectral estimates of the swell from this storm. The greatest dominant wave periods measured were approximately 20-25 s, and significant wave heights measured ranged from 3 to 8 m. Wave spectra from an array of three nondirectional buoys are used to find the source of the long-period swell. Directional wave spectra from a heave-pitch-roll buoy are also used to make an independent estimate of the source of the swell. The ridge-line method, using time-frequency contour plots of wave spectral energy density, is used to determine the time of swell generation, which is used with the appropriate surface pressure analysis to infer the swell generation area. The diagnosed sources of the swell are also compared with nowcasts from the Global Spectral Ocean Wave Model of the Fleet Numerical Oceanography Center. A simple method of predicting the propagation of ocean swell, by applying a simple kinematic model of wave propagation to the estimated point and time source, is demonstrated.

Mettlach, Theodore↗

Semiconductor laser-based ranging instrument for earth gravity measurements

A laser ranging instrument is being developed to measure the spatial variations in the Earth's gravity field. It will range in space to a cube corner on a passive co-orbiting sub-satellite with a velocity accuracy of 20 to 50 microns/sec by using AlGaAs lasers intensity modulated at 2 GHz.

Abshire, James B.↗

Tropospheric range error parameters: Further studies

Improved parameters are presented for predicting the tropospheric effect on electromagnetic range measurements from surface meteorological data. More geographic locations have been added to the earlier list. Parameters are given for computing the dry component of the zenith radio range effect from surface pressure alone with an rms error of 1 to 2 mm, or the total range effect from the dry and wet components of the surface refractivity and a two-part quartic profile model. The new parameters are obtained, as before, from meteorological balloon data but with improved procedures, including the conversion of the geopotential heights of the balloon data to actual or geometric heights before using the data. The revised values of the parameter k (dry component of vertical radio range effect per unit pressure at the surface) show more latitude variation than is accounted for by the variation of g, the acceleration of gravity.

Hopfield, H. S.↗

The processing of the Viking Orbiter range data and its contribution to Mars gravity solutions

The processing of Doppler data has been the primary method for deriving models of the Mars gravity field. Since the Mariner 9 and Viking spacecraft were placed in orbit about Mars, many models from degree and order 6 to degree and order 50 have been developed. However, during the Viking mission, some 26,000 range measurements to the two Viking Orbiters were also obtained. These data have not previously been used in the derivation of Mars gravity models. A portion of these range data have been processed simultaneously with the Doppler data. Normal equations were generated for both sets of data and were used to create two solutions complete to degree and order 30: a nominal solution including both the range and the Doppler data (MGM-R100), and another solution including only the Doppler data (MGM-R101). Tests with the covariances of these solutions, as well as with orbit overlap tests indicate that the interplanetary range data can be used to improve the modeling of the Mars gravity field.

Lemoine, Frank G.↗

Mars Dynamics from Earth-Based Tracking of the Mars Pathfinder Lander

Measurements of Mars' rotational variations can be conducted via Earth-based radio tracking observations of the Mars Pathfinder lander during an extended mission. Two-way range measurements between an Earth tracking station and the lander will enable precise monitoring of the planet's orientation, allowing details of Mars' internal structure and global surface/atmosphere interactions to be determined. An analysis has been performed to investigate the accuracy with which key physical parameters of Mars can be determined using the Earth-based radio tracking measurements. Acquisition of such measurements over one Martian year should enable determination of Mars' polar moment of inertia to 1% or better, providing a strong constraint on radial density profiles (and hence on the iron content of the core and mantle) and on long-term variations of the obliquity, which influences the climate. Variations in Mars length of day and polar motion should also be detectable, and will yield information on the seasonal cycling of carbon dioxide between the atmosphere and the surface.

Folkner, W. M.↗