Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiographs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Planar shock-induced bubble collapse and jetting in water captured via X-ray phase contrast imaging

Shock wave–bubble interactions in water manifest rich dynamics driven by a combination of strong pressure and density mismatches. They have a wide variety of applications, including the injection of pharmaceuticals, and through scaling, enable the exploration of various aspects of high-energy-density systems such as inertial confinement fusion. In this work, the interaction between a micrometric nitrogen bubble and a planar shock wave, characterized by a Mach number of M = 1.24 and a peak pressure of p max = 0.57 , is experimentally recorded using ultra-high-speed x-ray phase contrast imaging. Highly resolved radiographs provide access to all phase discontinuities along the beam path, offering quantities such as the time-varying bubble size, the speed of a jet produced during the bubble collapse, and the time evolution of the shock wave front, which are critical benchmark data for numerical scheme validation. This study addresses the lack of well-characterized, repeatable, and high spatiotemporal resolution experiments at negative Atwood numbers by providing shock–bubble visualization and corresponding numerical simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Demonstration of improvement of energy conversion rate from kJ PW laser to protons with electron confinement

Kilojoule-class relativistic intensity lasers can produce energetic protons with high energy conversion efficiencies in the interaction with a thin foil target. Using the national ignition facility advanced radiographic capability (NIF-ARC) laser, we demonstrated an enhancement of energy conversion from laser to protons by the effective confinement of fast electrons in the laser spot by random kicks from the self-excited field. The number of fast electrons was increased by 4.6 times by increasing the ratio of the laser spot size to the foil thickness to strengthen the confinement effect. The energy conversion efficiency from laser to protons increases approximately linearly with the enhancement of the number of fast electrons. The conversion rate for protons with energies above 8 MeV was 1.8 %. The result leads to high efficiency proton acceleration which is beneficial in applications, such as proton radiography and plasma heating in laser fusion.

Physics↗

Hot electron preheat effects in two-photon polymerization plastic lattice laser-driven shock-tube experiments on the OMEGA laser

We present simulations of Omega shock tube experiments designed to investigate hot electron preheat effects in 3D-printed, two-photon polymerization (2PP) plastic lattices. Preheat is inferred in the experiments from the expansion of a plastic witness disk embedded in the lattice. Using the Eulerian radiation-hydrodynamics code xRAGE, we model shock propagation and preheat from both radiative and hot electron energy sources to evaluate their relative impact. To simulate the transport of laser-generated hot electrons, the nonlocal electron heat transport model proposed by Schurtz, Nicolaï, and Busquet (SNB) is extended with a hot electron source term and an energy cascade algorithm. We explore how variations in ablator, lattice geometry, and laser drive affect the shock velocity and witness disk expansion. Simulations show that the inclusion of a 5 μm gold layer reduces shock pressure by 60% and shock speeds by 30%–40% but does not significantly reduce the hot electron preheat, and that different lattice geometries lead to enhanced shock velocities—up to 40% faster than in homogeneous foams. However, radiative and conductive preheat from classical mechanisms alone fail to match experiment. By including a hot electron source term, we reproduce experimental observables such as disk expansion rates and spatial radiographic features. We find that a hot electron population corresponding to 4%–8% of the incident laser energy with T hot = 50 keV produces expansion which agrees with the experimental data, suggesting hot electron preheat is the most plausible explanation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simultaneous hard x-ray Talbot phase and dark-field imaging in laser experiments at XFEL facilities

X-ray Free Electron Laser (XFEL) facilities offer unprecedented opportunities to advance instrumentation for studying matter under extreme conditions. In this study, we harnessed the enhanced x-ray capabilities of XFELs to demonstrate dark field imaging in laser-driven experiments at XFEL facilities. Utilizing a Talbot x-ray interferometer, we simultaneously captured transmission, dark-field, and differential phase contrast radiographs of laser-driven metallic foils. Our work showcases the feasibility of single-shot grating-based Talbot x-ray dark-field imaging in pump-probe experiments at XFEL facilities, opening doors to a wide range of hard x-ray imaging applications in material science and high-energy density physics.

Bouffetier, V. [Helmholtz-Zentrum Dresden-Rossendo↗

The role of focusing geometry in MeV x-ray production from petawatt laser–solid interaction

Relativistic laser–plasma interactions provide a compact and flexible route to generating bright, ultrashort pulses of MeV x rays, with applications in high-energy density science, nuclear physics, and radiography. Despite extensive study of intensity scaling in laser-driven electron acceleration, the role of focusing geometry and focal-volume effects in MeV radiation production remains insufficiently understood. Here, we present experimental and kinetic simulation results from the Texas Petawatt Laser (120 J, 140 fs) in which the focusing geometry (f/3 or f/1.5) is varied, while the laser energy and pulse duration are fixed. Experimentally, the f/3 geometry produces approximately three times more MeV radiation than the f/1.5 geometry, despite its twofold lower nominal vacuum intensity. This result is based on the time-integrated radiation per unit solid angle, as measured along the diagnostic line of sight. Three-dimensional particle-in-cell simulations reproduce this trend when a modest (10s of μm) effective focal plane shift is introduced, demonstrating that relativistic laser–plasma coupling is highly sensitive to focal geometry in the presence of a preplasma. This behavior is consistent with differences in interaction length and effective intensity at the critical surface between the two configurations. The sensitivity of the tightly focused f/1.5 configuration ($z_R ≈$⁠ 5 μ m) reflects the combined influence of thermal lensing and an extended preplasma, while the f/3 geometry (⁠$z_R ≈$ 80 μ m) remains comparatively robust. These results demonstrate a breakdown of conventional intensity scaling and identify focusing geometry as a critical control parameter for MeV electron and x-ray generation at petawatt powers. Implications for laser–plasma-based radiographic facilities are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energy response characterization of current-mode MeV Cherenkov aerogel detectors

Current-mode Cherenkov aerogel detectors have been used to measure time resolved spectra of MeV radiographic x-ray sources and have been considered to replace gas Cherenkov systems. The simulations of the Cherenkov response of aerogel detectors have uncertainties in how to model the complex structure of aerogels. Data from three sites—the Idaho electron beam, the Los Alamos Site electron beam and microtron sources at Los Alamos—have been used to calibrate the relative energy response of 15 aerogels, varying in density from 10 to 430 mg/cm 3 , from incident electrons with energies from 1 to 12 MeV. Detector simulations need to introduce density variation in the aerogels to match the collected data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Archival records housed at USTUR support radium dial worker dosimetry

The American radium dial worker (RDW) cohort of over 3200 persons is being revisited as part of the Million Person Study (MPS) to include a modern approach to RDW dosimetry. An exceptional source of data and contextualization in this project is an extensive collection of electronic records (digitized from existing microfilm and microfiche) housed at the United States Transuranium and Uranium Registries (USTUR). Although the type, extent, and quality (e.g. legibility) of record(s) varies between individuals, the remarkable occupational, medical and demographic data include in vivo radiation measurements (e.g. radon breath, whole body counts), autopsy results, medical records (including copies of radiographs), interviews over the years, and correspondence. Of particular dosimetric interest are the details of radiation measurements. For example, there are some instances where hand-written and transcribed values are both available, along with notes providing context for why a particular measurement in a series of measurements was chosen to assign an intake, or if there were concerns about a particular measurement. Born prior to 1935, RDW have nearly all passed away. Thus, the updated dosimetry, especially for the skeletal tissues, will allow the correlation of lifetime cumulative dose with radiation risk. Here we review typical information available in this collection of historical records and highlight some interesting finds. Additionally, we discuss the relevance to current and ongoing work related to updating the dosimetry of the RDW in the MPS, including providing an example of the usefulness of information contained in these records. The RDW cohort provides a unique historical perspective on occupational exposure to radium, making it a valuable dataset for understanding long-term health effects and improving current radiation protection standards.

Million Person Study↗

High-energy X-ray imaging with a Germanium MM-PAD hybrid pixel detector

Germanium is a high-Z sensor material with excellent energy resolution and attractive properties for high-energy photon detection. Despite its advantages, the need for cryogenic operation and challenges in the fabrication of pixelated high-purity germanium have hindered the development of segmented detectors. We report on the fabrication and performance of a germanium imaging detector with 150 μm pixel pitch hybridized to the MM-PAD ASIC. The detector was capable of high-resolution radiographic imaging and has a fast temporal response. Additionally, we describe the detector's upper operating temperature limits using both the MM-PAD and MARS ASICs, achieving stable operation up to 130 K and 190 K, respectively.

36 MATERIALS SCIENCE↗

A TOPAS model for lens-based proton radiography

Abstract Objective. Proton Radiography can be used in conjunction with proton therapy for patient positioning, real-time estimates of stopping power, and adaptive therapy in regions with motion. The modeling capability shown here can be used to evaluate lens-based radiography as an instantaneous proton-based radiographic technique. The utilization of user-friendly Monte Carlo program TOPAS enables collaborators and other users to easily conduct medical- and therapy- based simulations of the Los Alamos Neutron Science Center (LANSCE). The resulting transport model is an open-source Monte Carlo package for simulations of proton and heavy ion therapy treatments and concurrent particle imaging. Approach. The four-quadrupole, magnetic lens system of the 800-MeV proton beamline at LANSCE is modeled in TOPAS. Several imaging and contrast objects were modelled to assess transmission at energies from 230–930 MeV and different levels of particle collimation. At different proton energies, the strength of the magnetic field was scaled according to βγ, the inverse product of particle relativistic velocity and particle momentum. Main results. Materials with high atomic number, Z, (gold, gallium, bone-equivalent) generated more contrast than materials with low-Z (water, lung-equivalent, adipose-equivalent). A 5-mrad collimator was beneficial for tissue-to-contrast agent contrast, while a 10-mrad collimator was best to distinguish between different high-Z materials. Assessment with a step-wedge phantom showed water-equivalent path length did not scale directly according to predicted values but could be mapped more accurately with calibration. Poor image quality was observed at low energies (230 MeV), but improved as proton energy increased, with sub-mm resolution at 630 MeV. Significance. Proton radiography becomes viable for shallow bone structures at 330 MeV, and for deeper structures at 630 MeV. Visibility improves with use of high-Z contrast agents. This modality may be particularly viable at carbon therapy centers with accelerators capable of delivering high energy protons and could be performed with carbon therapy.

60 APPLIED LIFE SCIENCES↗

Inverse Method for Noninvasive Material Discrimination with Multienergy X-Ray Radiography

Active x-ray inspections have great potential for noninvasive detection of illicit materials. Dual-energy x-ray radiography, in particular, has been used to determine material composition by utilizing the energy-dependence of the x-ray attenuation coefficients. However, current implementations of this method are limited in their ability to determine the material composition of composite objects. Here, in this paper, we present an inverse algorithm that uses multienergy x-ray radiography data to noninvasively reconstruct the contents of a container. A critical feature of the current contribution is that material identification can be performed using conventional detectors and x-ray spectra with different endpoint energies produced by varying nothing more than the tube voltage. Adaptive regularization is used to increase the accuracy of material estimations from multienergy data sets. The utility of these methods is demonstrated with experimentally acquired radiographs obtained using a tunable x-ray source that produces spectra with endpoint energies of 100–450 keV. The object inspected is a scale model of a nuclear materials storage container composed of three-dimensional printed plastic and stainless-steel spheres inside a thin-walled steel container. Reconstructions of the steel sphere thicknesses are within a root-mean-square error of 0.37 cm.

47 OTHER INSTRUMENTATION↗

Biermann-Battery-Driven Magnetized Collisionless Shock Precursors in Laser-Produced Plasmas

This Letter reports the first complete observation of magnetized collisionless shock precursors formed through the compression of Biermann-battery magnetic fields in laser produced plasmas. At OMEGA, lasers produce a supersonic CH plasma flow which is magnetized with Biermann-battery magnetic fields. The plasma flow collides with an unmagnetized hydrogen gas jet plasma to create a magnetized shock precursor. The situation where the flowing plasma carries the magnetic field is similar to the Venusian bow shock. Imaging 2⁢𝜔 Thomson scattering confirms that the interaction is collisionless and shows density and temperature jumps. Proton radiographs have regions of strong deflections and FLASH magnetohydrodynamic (MHD) simulations show the presence of Biermann fields in the Thomson scattering region. Electrons are accelerated to energies of up to 100 keV in a power-law spectrum. Here, OSIRIS particle-in-cell (PIC) simulations, initialized with measured parameters, show the formation of a magnetized shock precursor and corroborate the experimental observables.

High-energy-density plasmas↗

Amplification of laser imprint in the presence of strong, externally imposed, target-normal magnetic fields

Here, an experiment was performed on the OMEGA EP Laser System to investigate the effects of magnetic fields on laser imprint. A 30 µ⁢m thick CH target was driven by a single beam delivering 3.0 kJ of UV energy in a 5 ns square pulse without smoothing by spectral dispersion. The Rayleigh-Taylor amplification of this beam's imprint on the target surface was monitored using face-on gated x-ray radiography from a Gd backlighter. Magnetic fields of up to 45 T were applied normal to the target surface. Analysis of the resulting radiographs shows a 60 ± 13% increase in the spectrally resolved surface perturbation amplitudes, consistent at all times and for all unsaturated frequencies. This consistency indicates that the increase in perturbation amplitudes was due to a change in the initial amplitudes rather than Rayleigh-Taylor growth. This is supported by the trajectory of individual modes and the inferred time-averaged perturbation growth rates. Laser imprint is therefore inferred to have increased due to strong magnetic fields that remain in the conduction zone of the target, suppressing off-axis electron motion and limiting the effects of thermal smoothing.

direct drive↗

Fast Hyperspectral Neutron Tomography

Hyperspectral neutron computed tomography is a tomographic imaging technique in which thousands of wavelength-specific neutron radiographs are measured for each tomographic view. In conventional hyperspectral reconstruction, data from each neutron wavelength bin are reconstructed separately, which is extremely time-consuming. These reconstructions often suffer from poor quality due to low signal-to-noise ratios. Consequently, material decomposition based on these reconstructions tends to produce inaccurate estimates of the material spectra and erroneous volumetric material separation. In this paper, we present two novel algorithms for processing hyperspectral neutron data: fast hyperspectral reconstruction and fast material decomposition. Both algorithms rely on a subspace decomposition procedure that transforms hyperspectral views into low-dimensional projection views within an intermediate subspace, where tomographic reconstruction is performed. The use of subspace decomposition dramatically reduces reconstruction time while reducing both noise and reconstruction artifacts. We apply our algorithms to both simulated and measured neutron data and demonstrate that they reduce computation and improve the quality of the results relative to conventional methods.

Chowdhury, Mohammad Samin Nur [Purdue University]↗

A partial-volume correction for quantitative spectral x-ray radiography

The technique of spectral radiography has been shown to accurately discriminate a materials elemental composition by using known x-ray physics. This is achieved with a state-of-the-art pixelated spectrometer and a high-fidelity physical model. Similar to other radiographs, the system suffers from partial volume attenuation where the sample projection onto a pixel is only a fraction of the pixel area, leaving the rest unattenuated. This study updates the physical model to account for fractional area which presents new challenges to the existing algorithm. We present how this update is made and explore approaches to stabilize the algorithm through parameter scaling, constrained optimization, and hyperparameter selection.

Gillis, Wesley C.↗

Three-Dimensional Particle-in-Cell Analysis of Mechanical Design Tolerances of the Scorpius Injector With Warp

Here, this article examines the mechanical design tolerances for the Scorpius injector using a 3-D particle-in-cell (PIC) code. In order to meet its objective as a high-fidelity, multipulse flash X-ray source, the accelerator has requirements for the electron beam in order to minimize the spot size of the beam focused onto a foil target to create high fluence X-rays at energies greater than 10 MeV. The requirements for alignment of the cathode, anode beam pipe, focusing solenoids, and transport solenoids specified using Trak and AMBER are independently verified using a 3-D electrostatic/magnetostatic model of the Scorpius injector, including transverse magnetic field errors that arise from mechanical alignment errors. It is predicted that the injector will meet the performance requirements for radiographic operation and has a design margin to correct for potentially unforeseen operating conditions.

42 ENGINEERING↗

Preliminary hyperspectral neutron radiography of binder jet 3D printed and melt infiltrated Si–SiC

The preliminary results of hyperspectral neutron radiography of Si–SiC made with binder jet additive manufacturing, subsequent carbon addition, and silicon melt infiltration are presented. The samples were measured in the processing states before and after the melt infiltration to determine if neutrons would help characterize the microstructure to better understand the melt infiltration process. Theoretical Bragg edges were calculated for comparison with the radiographic results. The changes in the Bragg edges from pre- to post-infiltrated reaction-bonded SiC were evident, that could be used to address the differences in microstructures. In conclusion, the preliminary results presented in this study demonstrated that neutron Bragg-edge imaging is possible with Si–SiC reaction-bonded ceramics and can help determine the microstructure of melt infiltrated samples.

SiC↗

Europium-doped barium chloride storage phosphor plate synthesized by pulsed laser deposition

In computed radiography, scattering of the stimulation light by the storage phosphor crystals in the imaging plates negatively impacts spatial resolution. Storage phosphor plates with thinner phosphor layers have been developed to reduce scattering distance and increase spatial resolution, although at the expense of reduced x-ray absorption. The authors hypothesize that a transparent or translucent nanostructured film, containing a much higher percentage of storage phosphor crystals than achievable in bulk glass-ceramic materials made by conventional methods, may have acceptable photostimulated luminescence efficiency and imaging performance characteristics greater than commercial imaging plates. Films were produced via pulsed laser deposition by alternating target materials of the storage phosphor BaCl 2 :Eu 2+ and either silica or silicon. X-ray diffraction and photoluminescence characterization were conducted to confirm the presence of BaCl 2 :Eu 2+ crystallites. The films were able to store optical data and be read out to produce x-ray radiographs demonstrating 50-mu m spatial resolution. The performance of the experimental storage phosphor plates was compared to commercially available imaging plates. The authors demonstrate for the first time the synthesis of a glass-ceramic imaging plate for computed radiography by pulsed laser deposition.

36 MATERIALS SCIENCE↗

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A field-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt γ-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium γ-ray detector. Fine spatial resolution neutron and α detectors enable precise mapping of characteristic γ-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus significantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

Bucher, Brian [Idaho National Laboratory (INL)]↗