Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiographs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Design of a high-resolution Rayleigh-Taylor experiment with the Crystal Backlighter Imager on the National Ignition Facility

The Rayleigh-Taylor (RT) instability affects a vast range of High Energy Density (HED) length scales, spanning from supernova explosions (10 13 m) to inertial confinement fusion (10 -6 m). In inertial confinement fusion, the RT instability is known to induce mixing or turbulent transition, which in turn cools the hot spot and hinders ignition. The fine-scale features of the RT instability, which are difficult to image in HED physics, may help determine if the system is mixing or is transitioning to turbulence. Earlier diagnostics lacked the spatial and temporal resolution necessary to diagnose the dynamics that occur along the RT structure. A recently developed diagnostic, the Crystal Backlighter Imager (CBI), [1,2] can now produce an x-ray radiograph capable of resolving the fine-scale features expected in these RT unstable systems. This paper describes an experimental design that adapts a well-characterized National Ignition Facility (NIF) platform to accommodate the CBI diagnostic. Simulations and synthetic radiographs highlight the resolution capabilities of the CBI in comparison to previous diagnostics. Furthermore, the improved resolution of the system can provide new observations to study the RT instability's involvement in mixing and the transition to turbulence in the HED regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monte Carlo simulation methodology for characterizing the energy response function and resolving power of a digital Flat Panel Detector (FPD) assembly

The use of high-resolution, digital flat panel detectors (FPDs) makes quantitative assessments of radiographic and 3D tomographic representations feasible. However, the energy response function and spatial resolving power of the detector must be known. Here, we present a methodology for characterizing an FPD assembly using Monte Carlo simulations. The detector assembly modeled here was fielded in the 3-Ring Flash X-ray Imaging System designed and built at Lawrence Livermore National Laboratory (LLNL), which employs fifteen Carestream ® HPX-DR3543 FPDs enclosed in protective housings. Detailed Monte Carlo (MCNP6) simulations of an as-fielded detector assembly were performed to estimate its energy response function in terms of analog-to-digital unit (ADU) “counts” per pixel per incident x-ray as a function of energy up to ∼ 500 keV and its theoretical (idealized) resolving power. The practical resolving power of the FPD assembly in a realistic scenario was then estimated by simulating radiographic images of a variant of the United Kingdom (U.K.) “Kaleidoscope” resolution target.

Physics↗

Time-Resolved Fuel Density Profiles of the Stagnation Phase of Indirect-Drive Inertial Confinement Implosions

The implosion efficiency in inertial confinement fusion depends on the degree of stagnated fuel compression, density uniformity, sphericity, and minimum residual kinetic energy achieved. Compton scattering-mediated 50–200 keV x-ray radiographs of indirect-drive cryogenic implosions at the National Ignition Facility capture the dynamic evolution of the fuel as it goes through peak compression, revealing low-mode 3D nonuniformities and thicker fuel with lower peak density than simulated. By differencing two radiographs taken at different times during the same implosion, we also measure the residual kinetic energy not transferred to the hot spot and quantify its impact on the implosion performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Harmonic Generation and Inverse Cascade in the z-Pinch Driven, Preseeded Multimode, Magneto-Rayleigh-Taylor Instability

We report the magneto-Rayleigh-Taylor instability (MRTI) plays an essential role in astrophysical systems and in magneto-inertial fusion, where it is known to be an important degradation mechanism of confinement and target performance. In this Letter, we show for the first time experimental evidence of mode mixing and the onset of an inverse-cascade process resulting from the nonlinear coupling of two discrete preseeded axial modes (400- and 550 - μm wavelengths) on an Al liner that is magnetically imploded using the 20-MA, 100-ns rise-time Z Machine at Sandia National Laboratories. Four radiographs captured the temporal evolution of the MRTI. We introduce a novel unfold technique to analyze the experimental radiographs and compare the results to simulations and to a weakly nonlinear model. We find good quantitative agreement with simulations using the radiation magnetohydrodynamics code hydra. Spectral analysis of the MRTI time evolution obtained from the simulations shows evidence of harmonic generation, mode coupling, and the onset of an inverse-cascade process. The experiments provide a benchmark for future work on the MRTI and motivate the development of new analytical theories to better understand this instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Autonomous Polycrystalline Material Decomposition For Hyperspectral Neutron Tomography

Hyperspectral neutron tomography is an effective method for analyzing crystalline material samples with complex compositions in a non-destructive manner. Since the counts in the hyperspectral neutron radiographs directly depend on the neutron cross-sections, materials may exhibit contrasting neutron responses across wavelengths. Therefore, it is possible to extract the unique signatures associated with each material and use them to separate the crystalline phases simultaneously.We introduce an autonomous material decomposition (AMD) algorithm to automatically characterize and localize polycrystalline structures using Bragg edges with contrasting neutron responses from hyperspectral data. The algorithm estimates the linear attenuation coefficient spectra from the measured radiographs and then uses these spectra to perform polycrystalline material decomposition and reconstructs 3D material volumes to localize materials in the spatial domain. Our results demonstrate that the method can accurately estimate both the linear attenuation coefficient spectra and associated reconstructions on both simulated and experimental neutron data.

Samin nur chowdhury, Mohammad↗

Scatter and Blur Corrections for High-Energy X-Ray Radiography

High-energy X-ray radiography is useful as a highly penetrating method for imaging through dense materials. However, the primary modes of interaction of X-rays at these energies involve scattering or the production of secondary high-energy photons, which can interfere with the image. In addition, detector blurring, often resulting from scatter within the detector, can reduce image sharpness. Both of these processes can be mitigated with the use of convolution kernels, with the main challenge being that the proper kernel to use is not known, particularly for the scatter contribution. By radiographing solid slabs of uniform attenuation, we show that point spread functions and material-specific point scatter functions can be determined to significantly reduce the effect of detector blurring and object scatter. Constraining the fits to the slabs and uniform transmission within the slabs is sufficient to recover these functions. A functional form that reproduces the angular distribution of high-energy bremsstrahlung X-rays is presented for recovering point scatter functions. In conclusion, the method is applied to radiographs of objects from bremsstrahlung X-ray sources operating at 4- and 7.5-MV endpoint energies and a significant increase in sharpness is observed.

Blind deconvolution↗

A Novel Anatomic Reconstruction for Posterior Tibialis Tendon in Treatment of Flexible Adult‐Acquired Flatfoot Deformity

Objective To present a novel approach for the anatomic reconstruction of the posterior tibialis tendon (PTT) in restoring plantar insertions and evaluate its efficiency in treating flexible adult‐acquired flatfoot deformity (AAFD) caused by PTT dysfunction. Methods For AAFD treatment, a novel PTT reconstruction method was presented. The current study involved 16 patients, including three men, and 13 women, from August 2017 to July 2019. The mean age was 43.2 ± 15.1 years (21–64 years). The innovative PTT repair method was used on all patients. The treatment involved performing a traditional Flexor Digitorum Longus (FDL) transfer in the navicular tuberosity and suturing the plantar insertions to FDL as tension was applied to tighten the plantar structures of the foot. The results were retrospectively analyzed. The clinical outcome was assessed using the pain visual analogue scale (VAS), the satisfaction VAS, and the American Orthopedic Foot and Ankle Society ankle–hindfoot scale (AOFAS‐AH). Isokinetic testing was performed using a dynamometer at 60°/s and 120°/s for inversion/eversion and plantarflexion/dorsiflexion, respectively, to determine the mean peak torque. Radiographic measurements were employed to assess the outcomes. Results Bone surgeries combined with the modified anatomic PTT reconstruction were performed on patients with medializing calcaneal osteotomy in 12 (75%) patients and subtalar joint fusion in four (25%) patients. The branch linking to the plantar insertions was detected in every case, with an average width of 3.5 ± 0.8 mm (3.1–4.3 mm). All patients were followed up for the mean of 16.8 ± 1.8 months (range, 15–20 months). The average postoperative functional scores, including pain VAS, satisfaction VAS, total AOFAS‐AH, and all AOFAS‐AH sub‐scales, steadily improved during the follow‐up. In the last follow‐up, isokinetic testing revealed no loss of plantarflexion strength ( p = 0.350 and 0.098) and significant improvement in the inversion strength ( p = 0.007 and 0.008) in the operated ankles at 60°/s and 120°/s. Radiographic outcomes, particularly the talar head uncovering, improved significantly after more than a year ( p < 0.001 for all). Conclusions The novel technique for PTT reconstruction in restoring the plantar insertions serves as an effective procedure in treating AAFD caused by PTT dysfunction in terms of delivering a consistent improvement in ankle inversion strength, medial longitudinal arch restoring, and satisfactory clinical outcomes.

Hu, Yong↗

Scatter Removal using Black Body Grids and Determining the Minimum Resolvable Hydrogen Concentration at MARS

This dataset was used to develop and validate a scatter-correction pipeline for neutron radiographs acquired at the MARS beamline, based on the methodology of Carminati et al. (2019). Scatter removal was performed using 36 gadolinium black bodies to characterize and remove the spatially varying neutron scatter field that cannot be eliminated by conventional open-beam normalization. The dataset comprises eight samples - four single-crystal nickel and four polycrystalline austenitic 316L stainless steel. Within each material system, samples were pre-charged with hydrogen gas at four charging pressures (1.5, 5, 12.5, and 20 kpsi). Following scatter correction, the pipeline was applied to all radiographs to recover quantitative attenuation maps. After subtracting the known attenuation contribution of the metal matrix, spatial maps of the hydrogen attenuation coefficient were obtained for each sample. This data was then used to construct a calibration curve relating hydrogen attenuation to hydrogen concentration and to determine the minimum resolvable hydrogen concentration at the MARS beamline. The resulting dataset provides a pressure-resolved calibration standard for quantitative hydrogen mapping using neutron radiography.

36 MATERIALS SCIENCE↗

Scorpius and The Integrated Test Stand [Slides]

Scorpius will provide (DARHT scale) flash-radiography of dynamic nuclear material. DARHT radiographs non-nuclear (surrogate) materials at a cadence of 8 to 10 hydrodynamic shots per year. Scorpius will radiograph nuclear material at an initial cadence of about 2 to 3 subcritical shots per year in a more challenging environment. Both machines are Linear Induction Accelerators (LIAs) and generate X-rays with high-current, relativistic electron beams. Their use is termed Flash-Radiography.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Analytically Derived Piezoelectric Ejecta Data Transformations, with Implications for Claims of Experimentally Observed Self-Similarity

Building upon a previously documented analytic formalism, we derive a set of data transformations that relate piezoelectrically inferred time-dependent ejecta masses, dynamical ejecta cloud densities, and "radiographic" ejecta cloud density distributions. These transformation rules are derived rigorously, with careful attention to the assumption of instant ejecta production which is inherent in the piezoelectric mass inference procedure. Some of these relationships have not appeared previously in the literature, including solutions for the unique ejecta velocity distribution and radiographic ejecta cloud density distribution consistent with the instant-production assumption for a given piezoelectrically inferred mass dataset. In deriving the latter, we prove that—again subject to the ubiquitous instant-creation assumption—measurements at a single sensor are sufficient to determine properties of the ejecta cloud everywhere at all times. Other data transformation relationships have appeared in the literature without a rigorous derivation, or have been stated in forms that obscure the key mathematical relationships. We apply these results to arguments for self-similar ejecta cloud evolution, thereby deriving mathematical expressions by which claims of self-similarity may be examined. We prove that one analysis used in the literature to claim experimental evidence of a short ejecta production timescale—and consequently of self-similar cloud evolution—in fact places no constraint the ejecta production interval and therefore does not support the associated conclusion. We also provide a potentially useful uniqueness proof.

30 DIRECT ENERGY CONVERSION↗

DARHT Axis 1 Performance Results with and without a Blumlein Charge Unit

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Axis 1 of DARHT produces a 20- MeV, 2-kA, 80-ns-FWHM electron beam. As DARHT Axis 1 enters its twentieth year of operation, the probability of Blumlein Charge Unit (BCU) failure has increased and the risk of a failure on the day of an explosive experiment has become more likely. Replacement time for a BCU is four to six hours. This report examines the radiographic and beam transport effect of operating the accelerator with a missing or reduced charge voltage BCU. The results are compared with normal, full machine operation. A prescription for alternate operation with missing or reduced charge voltage on BCU22 is given.

47 OTHER INSTRUMENTATION↗

Expanded Capabilities and Opportunities for Virtual Beamline Code

In the 25 years since LLNL broke ground on the National Ignition Facility (NIF) - a cornerstone of the National Nuclear Security Administration’s Stockpile Stewardship Program - the NIF and Photon Science (NIF&PS) Directorate has steadily pushed the boundaries of laser physics, nonlinear optics, and photonics in service of inertial confinement fusion experiments, and advanced photon sources development. Beyond the 192 beamlines of the primary laser facility with its world-record energy and fusion yields, NIF&PS capabilities have expanded to include chirped-pulse amplification, kilojoule petawatt-class short-pulse systems to generate hard x-ray radiographic probes, high-average power lasers as secondary sources for generation or wake field particle acceleration along directed energy applications, and other scientific pursuits. The Computing Directorate partners with NIF&PS on numerous projects and technologies from diagnostic measurements and high performance control systems to data analysis, information technology infrastructure, and scientific simulation code development. “This strong collaboration enables cutting-edge science, particularly with regard to physics-based modeling and simulation,” says physicist Jean-Michel Di Nicola. One crucial capability for NIF&PS is the Virtual Beamline (VBL) laser simulation code. It can model all the major laser physics and technology involved in the design optimization, commissioning, and operations of advanced laser architectures from tabletop to NIF-scale. VBL provides researchers with high-fidelity models and high-resolution calculations of laser performance predictions—including for the entire NIF laser system, the Advanced Radiographic Capability, parts of the High Repetition-Rate Advanced Petawatt Laser System laser delivered to the Czech Republic, and the Optical Science Laser. After more than two decades of experimentally verified physics and computing enhancements, this unique workhorse code is wrapping up another major milestone: migration from Java to C++ with a flurry of user interface and optimization features, as well as laser physics and high-resolution enhancements thanks to parallel execution on Livermore Computing platforms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DARHT : Enduring Lessons from a Technical Project in a National Laboratory Context [Slides]

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility at Los Alamos National Laboratory (LANL) is the world’s first flash x-ray facility able to take multiple high-resolution radiographs of the interior features of fast-moving dense objects during a single experiment. DARHT’s radiography and complimentary diagnostics makes it an important diagnostic tool in support of the US Department of Energy’s (DOE)/National Nuclear Security Administration (NNSA)’s stewardship of the US nuclear deterrent. The project to construct DARHT ran from 1988 through 2003. Initial Operating Capability along a single axis began in 1999. A technical issue delayed Critical Decision 4 for the full dual-axis capability until 2008. DARHT was characterized by several directed changes resulting from an environmental impact study, changes to the global security context resulting from the end of underground nuclear testing, and rapid evolution of applicable technology. Conventional building and lab-space construction were part of the project, but the project was dominated by Special Facility Equipment that, together with the mission to support the nuclear weapons program, required the project to be completed by national laboratories. Although the project pre-dated implementation of DOE Order 413.3, several important lessons for national laboratory projects remain applicable today and will be discussed here, including projects appropriate for the national laboratory environment, scope stability, risk acceptance and mitigation, communication, and collaboration. Finally, considerations for DOE contractor project managers are offered based upon the DARHT experience.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inferring Heat Flow in Laser Absorption Regions using Diagnostic Magnetic Fields

This research was motivated by the desire to obtain a measurement of heat-flow in overdense regions of a laser ablated plasma for the first time using a high energy proton beam. For sufficiently high energies, the proton beam can pass through overdense regions and only be deflected by electric and magnetic fields. As the transport of magnetic fields in a plasma are intrinsically linked to the transport of thermal energy, it was posited that such a measurement could be used to infer a heat-flow. While the project did not prove the method to be infeasible, difficulties with understanding the proton radiographs without an imposed magnetic field made the final aim of this project unreached. Instead, however, a closer understanding of proton radiographs of laser-solid interactions without an imposed field has been obtained. 5 shot days on The OMEGA Laser Facility have been awarded (3 through ICF and 2 as ride-along) to further investigate some of these features. Extrapolating current results to hohlraum conditions has the magnetic energy being a significant (10%) fraction of the laser drive energy, which has the potential to explain the NIF hohlraum drive deficit.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Inferring Heat Flow in Laser Absorption Regions using Diagnostic Magnetic Fields: Abstract

This research was motivated by the desire to obtain a measurement of heat-flow in overdense regions of a laser ablated plasma for the first time using a high energy proton beam. For sufficiently high energies, the proton beam can pass through overdense regions and only be deflected by electric and magnetic fields. As the transport of magnetic fields in a plasma are intrinsically linked to the transport of thermal energy, it was posited that such a measurement could be used to infer a heat-flow. While the project did not prove the method to be infeasible, difficulties with understanding the proton radiographs without an imposed magnetic field made the final aim of this project unreached. Instead, however, a closer understanding of proton radiographs of laser-solid interactions without an imposed field has been obtained. 5 shot days on The OMEGA Laser Facility have been awarded (3 through ICF and 2 as ride-along) to further investigate some of these features. Extrapolating current results to hohlraum conditions has the magnetic energy being a significant (10%) fraction of the laser drive energy, which has the potential to explain the NIF hohlraum drive deficit.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-Probe 22A: Post shot Data and Analysis

The Multi-Probe 22A experiments took place on the Omega EP laser in March 2022. The goal was to discover issues with simultaneous x-ray and proton radiography of static and dynamic test objects. The x-ray and proton probes were generated by short-pulse laser-matter interactions. Significant crosstalk between the proton beam and x-ray detector was observed. Several static radiographs were made, including a set of proton images made with different laser energies. No dynamic objects were radiographed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dark Field Proton Radiography (Los Alamos LDRD Report)

Proton radiography at LANL (pRad) takes advantage of the high flux, high proton energy, and flexible timing structure of LANSCE's 800-MeV proton beam to visualize dense, dynamic systems under extreme strain. With recent needs identified for the development of the W93, the pRad team has been actively searching for ways to increase the facility's radiographic capabilities. Recently, we discovered that utilizing two magnetic lenses (one upstream and one downstream of the object), and specific combinations of collimator choices within the two lenses, that the signal-to-noise ratio was improved by more than a factor of two. However, we did not fully understand the mechanism, and found that results did not match forward modeling predictions. This work specifically sought to implement an engineering solution to solve this problem, through the development of an actuated collimator that reduced the time required to swap collimator settings from a typical 4-8 hours, to less than 30 seconds. This allowed, in combination with a unique multi-material, multi-resolution stepwedge, to acquire an unprecedently enormous dataset, with in total 24 collimation combinations, and multiple diffuser settings and pulse patterns, equivalent to almost a full run cycle's worth of data in a few days. This massive dataset is currently being harnessed to make a fully-predictive, ultra-fast Python-based model of the system, to dial in specific settings for any future experiments that fully optimize that radiographic sensitivity to the material of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Probe Campaign FY24 Omega EP Shot Request [Slides]

The ultimate goal of the Multi-Probe experimental campaign is to assess the feasibility of using multiple probe species (x-ray, proton, neutron, and electron) in future LANL radiographic facilities. To use Omega EP most efficiently, two different experiments are proposed for each of the two requested days in FY24. In this way, shots may be interleaved on the two short pulse beams and the shot rate doubled. In FY24, we propose to continue to develop the neutron source by first optimizing the “pitcher” source of deuterons/protons and then adding the “catcher” neutron converter on day 2. The second series of experiments continues examining the origin and nature of the x-ray background found in our last two experiments. This background is not well understood or characterized by the community. The first day will measure the electrons emanating from the proton and x-ray targets while also optimizing the background shielding first used in FY23. The second day will test a geometry that enables simultaneous radiographs using both short-pulse beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗