Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantitative phase imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Cathodoluminescence of Al/x/Ga/1-x/As grown by liquid-phase epitaxy

Small-area contrast fluctuations observed in cathodoluminescence-mode SEM images of thin Al(x)Ga(1-x)As layers grown by liquid-phase epitaxy on GaAs:Cr substrates are attributed to local variations in alloy composition. Quantitative estimates of the composition excursions are obtained from the variations in CL intensity by calibration against compositions known from electron-probe microanalysis. In a typical sample, the CL variations are shown to correspond to peak-to-peak fluctuations of about 1 at. % of Al and occur over irregular regions generally in the range 6-20 microns in diameter.

Levin, E. R.↗

A Frequency Domain Methodology for Quantitative Evaluation of Diffuse Wavefield With Applications to Seismic Imaging

Abstract Ambient Noise Imaging (ANI) of subsurface structures relies on seismic interferometry of diffuse seismic wavefields. However, the lack of effective methods to quantify and identify highly diffuse waves hampers applications of ANI, particularly in evaluating seismic attenuation and monitoring structural changes with high temporal resolution. Conventional ANI approaches require data normalization, which effectively suppresses the non‐diffuse component with large amplitude but also results in significant loss of amplitude and phase information in the continuous seismic records. In this study, we propose a frequency domain method to quantitatively evaluate the degree of diffuseness of seismic wavefields by analyzing their statistical characteristics of modal amplitudes for stationarity and randomness. Tests on synthetic waveform and field nodal records show that the proposed method can effectively distinguish between diffuse and non‐diffuse waveforms for either single‐ or three‐component data. As an application, we identify a 60‐s‐long diffuse coda of a local M 2.2 earthquake recorded by a dense nodal array on the San Jacinto Fault Zone, and successfully extract high‐quality dispersion curve andQ‐value without performing data normalization. These results are consistent with those obtained by conventional methods that assess the correlation between coherency and the Green's function, and by modeling ballistic waves generated by road traffic. Our proposed method can advance the imaging of subsurface velocity and attenuation structures as well as monitoring temporal changes for scientific studies and engineering applications.

Geochemistry & Geophysics↗

SU-E-J-154: Image Quality Assessment of Contrast-Enhanced 4D-CT for Pancreatic Adenocarcinoma in Radiotherapy Simulation

Purpose: This study presents quantitative and qualitative assessment of the image qualities in contrast-enhanced (CE) 3D-CT, 4D-CT and CE 4D-CT to identify feasibility for replacing the clinical standard simulation with a single CE 4D-CT for pancreatic adenocarcinoma (PDA) in radiotherapy simulation. Methods: Ten PDA patients were enrolled and underwent three CT scans: a clinical standard pair of CE 3D-CT immediately followed by a 4D-CT, and a CE 4D-CT one week later. Physicians qualitatively evaluated the general image quality and regional vessel definitions and gave a score from 1 to 5. Next, physicians delineated the contours of the tumor (T) and the normal pancreatic parenchyma (P) on the three CTs (CE 3D-CT, 50% phase for 4D-CT and CE 4D-CT), then high density areas were automatically removed by thresholding at 500 HU and morphological operations. The pancreatic tumor contrast-to-noise ratio (CNR), signal-tonoise ratio (SNR) and conspicuity (C, absolute difference of mean enhancement levels in P and T) were computed to quantitatively assess image quality. The Wilcoxon rank sum test was used to compare these quantities. Results: In qualitative evaluations, CE 3D-CT and CE 4D-CT scored equivalently (4.4±0.4 and 4.3±0.4) and both were significantly better than 4D-CT (3.1±0.6). In quantitative evaluations, the C values were higher in CE 4D-CT (28±19 HU, p=0.19 and 0.17) than the clinical standard pair of CE 3D-CT and 4D-CT (17±12 and 16±17 HU, p=0.65). In CE 3D-CT and CE 4D-CT, mean CNR (1.8±1.4 and 1.8±1.7, p=0.94) and mean SNR (5.8±2.6 and 5.5±3.2, p=0.71) both were higher than 4D-CT (CNR: 1.1±1.3, p<0.3; SNR: 3.3±2.1, p<0.1). The absolute enhancement levels for T and P were higher in CE 4D-CT (87, 82 HU) than in CE 3D-CT (60, 56) and 4DCT (53, 70). Conclusions: The individually optimized CE 4D-CT is feasible and achieved comparable image qualities to the clinical standard simulation. This study was supported in part by Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

Data-driven picosecond X-ray imaging for quantitative plasma-induced shock characterization

Imaging dynamic events, especially shockwave behavior, is key to advancing high-energy-density (HED) research. Recent advances in fourth- and fifth-generation X-ray light sources allow for high-resolution imaging of fast phenomena, but limited beam time necessitates maximizing data acquisition. We present a benchtop-scale pulsed plasma device submerged in liquid heptane, capable of generating dynamic events at rates exceeding 10 Hz, supporting the field’s data-driven goals by producing large, high-quality imaging datasets. Using X-ray phase contrast imaging (XPCI) at the Advanced Photon Source, we imaged weak shockwaves (Mach ~ 1.2) in heptane interacting with plasma-induced cavitation bubbles, causing deviation from Rankine-Hugoniot behavior; to our knowledge, this represents the first direct imaging of such interaction. Our quantitative analysis offers insight into weak shock phenomena and energy-focusing applications in pulsed plasmas. These results highlight the potential for large datasets to advance dynamic HED research at current light source facilities, and have implications for fields such as inertial confinement fusion, plasma-enhanced chemical processing, and biomedical applications.

36 MATERIALS SCIENCE↗

Noise texture and signal detectability in propagation-based x-ray phase-contrast tomography

Purpose: X-ray phase-contrast tomography (PCT) is a rapidly emerging imaging modality for reconstructing estimates of an object's three-dimensional x-ray refractive index distribution. Unlike conventional x-ray computed tomography methods, the statistical properties of the reconstructed images in PCT remain unexplored. The purpose of this work is to quantitatively investigate noise propagation in PCT image reconstruction. Methods: The authors derived explicit expressions for the autocovariance of the reconstructed absorption and refractive index images to characterize noise texture and understand how the noise properties are influenced by the imaging geometry. Concepts from statistical detection theory were employed to understand how the imaging geometry-dependent statistical properties affect the signal detection performance in a signal-known-exactly/background-known-exactly task. Results: The analytical formulas for the phase and absorption autocovariance functions were implemented numerically and compared to the corresponding empirical values, and excellent agreement was found. They observed that the reconstructed refractive images are highly spatially correlated, while the absorption images are not. The numerical results confirm that the strength of the covariance is scaled by the detector spacing. Signal detection studies were conducted, employing a numerical observer. The detection performance was found to monotonically increase as the detector-plane spacing was increased. Conclusions: The authors have conducted the first quantitative investigation of noise propagation in PCT image reconstruction. The reconstructed refractive images were found to be highly spatially correlated, while absorption images were not. This is due to the presence of a Fourier space singularity in the reconstruction formula for the refraction images. The statistical analysis may facilitate the use of task-based image quality measures to further develop and optimize this emerging modality for specific applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emerging X-ray imaging technologies for energy materials

With the growing need for sustainable energy technologies, advanced characterization methods are becoming more and more critical for optimizing energy materials and understanding their operation mechanisms. In this review, we focus on the synchrotron-based X-ray imaging technologies and the associated applications in gaining fundamental insights into the physical/chemical properties and reaction mechanisms of energy materials. We will discuss a few major X-ray imaging technologies, including X-ray projection imaging, transmission X-ray microscopy, scanning transmission X-ray microscopy, tender and soft X-ray imaging, and coherent diffraction imaging. Researchers can choose from various X-ray imaging techniques with different working principles based on research goals and sample specifications. With the X-ray imaging techniques, we can obtain the morphology, phase, lattice and strain information of energy materials in both 2D and 3D in an intuitive way. In addition, with the high-penetration X-rays and the high-brilliance synchrotron sources, operando/in-situ experiments can be designed to track the qualitative and quantitative changes of the samples during operation. We expect this review can broaden readers’ view on X-ray imaging techniques and inspire new ideas and possibilities in energy materials research.

36 MATERIALS SCIENCE↗

Infrared Images of the Uranian Rings

Images of the Uranian rings at a wavelength of 2.2 micrometers, chosen to reduce the problem of scattered light from the planet, have been acquired on several occasions spanning the period 1978-1983. Although individual rings are not resolved in these images, the integrated brightness of the system is observed to vary with azimuth. The phase and amplitude of this variation is found to be consistent with the precession rate and variable width of the epsilon ring, as deduced from stellar occultation data. Quantitative analyses of the brightness variations permit an upper limit of approx. 0.0015 to be pladed on the average normal optical depth of any diffuse inter-ring material. Preliminary absolute calibration of the 1983 data yields an average ring geometric albedo, at 2.2 micrometers, of 0.22 + or - 0.002, consistent with previous estimates. Lastly, the potential use of near-infrared images in searches for faint inner satellites of Uranus is discussed.

Nicholson, P. D.↗

Automated thermal mapping techniques using chromatic image analysis

Thermal imaging techniques are introduced using a chromatic image analysis system and temperature sensitive coatings. These techniques are used for thermal mapping and surface heat transfer measurements on aerothermodynamic test models in hypersonic wind tunnels. Measurements are made on complex vehicle configurations in a timely manner and at minimal expense. The image analysis system uses separate wavelength filtered images to analyze surface spectral intensity data. The system was initially developed for quantitative surface temperature mapping using two-color thermographic phosphors but was found useful in interpreting phase change paint and liquid crystal data as well.

Buck, Gregory M.↗

Automated thermal mapping techniques using chromatic image analysis

Thermal imaging techniques are introduced using a chromatic image analysis system and temperature sensitive coatings. These techniques are used for thermal mapping and surface heat transfer measurements on aerothermodynamic test models in hypersonic wind tunnels. Measurements are made on complex vehicle configurations in a timely manner and at minimal expense. The image analysis system uses separate wavelength filtered images to analyze surface spectral intensity data. The system was initially developed for quantitative surface temperature mapping using two-color thermographic phosphors but was found useful in interpreting phase change paint and liquid crystal data as well.

Buck, Gregory M.↗

Coherent hard x-ray diffractive imaging of nonisolated objects confined by an aperture

Coherent hard x-ray imaging of nonisolated weak phase objects is demonstrated by confining x-ray beam in a region of a few micrometers in cross section using a micrometer-sized aperture. Two major obstacles in the hard x-ray coherent diffraction imaging, isolating samples and obtaining central speckles, are addressed by using the aperture. The usefulness of the proposed method is illustrated by reconstructing the exit wave field of a nanoscale trench structure fabricated on silicon which serves as a weak phase object. The quantitative phase information of the exit wave field was used to reconstruct the depth profile of the trench structure. The scanning capability of this method was also briefly discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics (FY23 Project Report)

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques.

36 MATERIALS SCIENCE↗

Model Calculations of Solar Spectral Irradiance in the 3.7 Micron Band for Earth Remote Sensing Applications

Since the launch of the first Advanced Very High Resolution Radiometer (AVHRR) instrument aboard TIROS-N, measurements in the 3.7 micron atmospheric window have been exploited for use in cloud detection and screening, cloud thermodynamic phase and surface snow/ice discrimination, and quantitative cloud particle size retrievals. The utility of the band has led to the incorporation of similar channels on a number of existing satellite imagers and future operational imagers. Daytime observations in the band include both reflected solar and thermal emission energy. Since 3.7 micron channels are calibrated to a radiance scale (via onboard blackbodies), knowledge of the top-of-atmosphere solar irradiance in the spectral region is required to infer reflectance. Despite the ubiquity of 3.7 micron channels, absolute solar spectral irradiance data comes from either a single measurement campaign (Thekaekara et al. 1969) or synthetic spectra. In this study, we compare historical 3.7 micron band spectral irradiance data sets with the recent semi-empirical solar model of the quiet-Sun by Fontenla et al. (2006). The model has expected uncertainties of about 2 % in the 3.7 pm spectral region. We find that channel-averaged spectral irradiances using the observations reported by Thekaekara et al. are 3.2-4.1% greater than those derived from the Fontenla et al. model for MODIS and AVHRR instrument bandpasses; the Kurucz spectrum (1995) as included in the MODTRAN4 distribution, gives channel-averaged irradiances 1.2-1.5 % smaller than the Fontenla model. For the MODIS instrument, these solar irradiance uncertainties result in cloud microphysical retrievals uncertainties comparable with other fundamental reflectance error sources.

Platnick, Steven↗

TH-A-BRF-10: Quantification of Subject-Specific Susceptibility-Related Geometric Distortion in Clinical Liver MRI for Radiation Therapy

Purpose: Subject-specific susceptibility-induced B0 inhomogeneity affects the geometric accuracy of MRI images, with potential impact on the accuracy of treatment planning and image guidance. This study quantifies individual distortions for patients with intrahepatic tumors. Methods: Liver MRI scans of 13 patients who were enrolled in an IRB approved study were acquired on a 3T scanner (Skyra, Siemens). Clinical contrast-enhanced images were acquired by a 3D Volume Interpolated Breath-Hold Examination (VIBE) sequence with TE/TR =1.65/4.3ms, voxel size = 2.5×2.5×3mm (axial sets) or 3.5×3.5×5mm (coronal sets), and frequency-encoding (FE) bandwidth of 440Hz/pixel. B0 inhomogeneity was evaluated by acquisition of dual gradient echoes (GRE) with TE1/TE2/TR =4.92/7.38/106ms, a voxel size of 3.5×3.5×3.75mm, a FE bandwidth of 290Hz/pixel and breath-hold. The phase difference maps from the two echoes were unwrapped using a quantitative MRI analysis software package (FSL, FMRIB, Oxford, UK). The resulting calculated B0 inhomogeneity maps (ΔB0 in Hz) were converted to voxel distortion maps in the FE direction (ΔX in mm) corresponding to the VIBE images. Results: Maximum susceptibility-induced distortions were observed in the liver dome near the diaphragm. Using results from coronal VIBE images in this study as examples, we observed clusters of voxels displaced close to or greater than ΔX=3.5mm (440 Hz in ΔB0) in the VIBE images of the liver in 3 patients, and greater than 2 mm but less than 3.5 mm in 12 patients. On average, approximately 14% of imaged liver voxels had distortions ΔX>±1mm (ΔB0>±125Hz) and 1% of the voxels had ΔX>±2mm (ΔB0>±250Hz). Conclusion: Although advanced MRI techniques, like VIBE, permit faster acquisitions allowing for breath-held examinations with limited motion-induced artifacts, this study suggests that localized distortions due to subject-specific susceptibility variations can occur and require additional advanced corrections based on measuring patient-specific B0 inhomogeneity maps. The authors would like to acknowledge funding support from NIH R01EB016079 and NIH/NCI RO1 CA132834.

60 APPLIED LIFE SCIENCES↗

Validating Hydrogen Concentrations Ahead of Crack Tips

Current models for hydrogen embrittlement rely on adjustable parameters to correct for uncertainties in crack tip stress fields and subsequent H 2 -concentrations. Techniques are needed to quantify these concentrations ahead of crack tips in mechanically loaded materials, providing data for model calibration and validation. The goal of this work was to establish advanced analytical techniques to detect and quantitatively measure hydrogen ahead of cracks in stressed solids. Two advanced analytical techniques, kelvin probe force microscopy (KPFM) and nuclear reaction analysis (NRA), were explored to evaluate the feasibility to provide qualitative and quantitative H 2 -concentration fields in geometries designed to be 'loaded' while under observation. The feasibility of the KPFM technique at detecting hydrogen was evaluated using electrochemically precharged hydrogen as well as a mixed hydrogen gas atmosphere. The KPFM technique was able to detect the presence of elevated stress and hydrogen concentrations ahead of a tensile loaded crack tip. The results suggest that KPFM is a viable technique for qualitatively imaging changes in stress and hydrogen concentrations on the scale needed to inform predictive models. KPFM could be used to provide local stress and hydrogen variations associated with hydrogen traps or different phases which require sensitive measurements on the micron scale. NRA provided quantitative measurements of the hydrogen-isotope deuterium ahead of a tensile loaded notch, however, the vacancy formation due to the incident high energy He 3 beam overwhelmed stress-assisted enhancement of deuterium concentrations such that the effect of stress was overshadowed in this analysis. Modeling of the chemo- mechanical hydrogen concentration change was used to verify this observation.

08 HYDROGEN↗

Partial scan artifact reduction (PSAR) for the assessment of cardiac perfusion in dynamic phase-correlated CT

Purpose: Cardiac CT achieves its high temporal resolution by lowering the scan range from 2{pi} to {pi} plus fan angle (partial scan). This, however, introduces CT-value variations, depending on the angular position of the {pi} range. These partial scan artifacts are of the order of a few HU and prevent the quantitative evaluation of perfusion measurements. The authors present the new algorithm partial scan artifact reduction (PSAR) that corrects a dynamic phase-correlated scan without a priori information. Methods: In general, a full scan does not suffer from partial scan artifacts since all projections in [0, 2{pi}] contribute to the data. To maintain the optimum temporal resolution and the phase correlation, PSAR creates an artificial full scan p{sub n}{sup AF} by projectionwise averaging a set of neighboring partial scans p{sub n}{sup P} from the same perfusion examination (typically N{approx_equal}30 phase-correlated partial scans distributed over 20 s and n=1,...,N). Corresponding to the angular range of each partial scan, the authors extract virtual partial scans p{sub n}{sup V} from the artificial full scan p{sub n}{sup AF}. A standard reconstruction yields the corresponding images f{sub n}{sup P}, f{sub n}{sup AF}, and f{sub n}{sup V}. Subtracting the virtual partial scan image f{sub n}{sup V} from the artificial full scan image f{sub n}{sup AF} yields an artifact image that can be used to correct the original partial scan image: f{sub n}{sup C}=f{sub n}{sup P}-f{sub n}{sup V}+f{sub n}{sup AF}, where f{sub n}{sup C} is the corrected image. Results: The authors evaluated the effects of scattered radiation on the partial scan artifacts using simulated and measured water phantoms and found a strong correlation. The PSAR algorithm has been validated with a simulated semianthropomorphic heart phantom and with measurements of a dynamic biological perfusion phantom. For the stationary phantoms, real full scans have been performed to provide theoretical reference values. The improvement in the root mean square errors between the full and the partial scans with respect to the errors between the full and the corrected scans is up to 54% for the simulations and 90% for the measurements. Conclusions: The phase-correlated data now appear accurate enough for a quantitative analysis of cardiac perfusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A tunable path-separated electron interferometer with an amplitude-dividing grating beamsplitter

We demonstrate a tunable path-separated electron interferometer using a single amplitude-dividing beamsplitter to prepare multiple spatially isolated, coherent electron probe beams. We place four electrostatic bi-prisms in the optical column of a scanning transmission electron microscope (STEM) to achieve path separations of up to 25 μ m, the largest demonstrated within amplitude-division electron interferometers while maintaining fringe visibility of the directly observed interference fringes at the detector. We characterize the fringe visibility of this setup over a range of path separations and perform STEM holography to reconstruct the full object wave of a fabricated Si ramp test phase object. We report a quantitative object-wave measurement in this configuration and confirm with an independent off-axis electron holography measurement. This experimental design can potentially be applied to high-resolution phase imaging and fundamental physics experiments, such as an exploration of the electron wave packet coherence length and the Aharonov-Bohm effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An atom probe perspective on phase separation and precipitation in duplex stainless steels

Here, three-dimensional chemical imaging of Fe–Cr alloys showing Fe-rich (α)/Cr-rich (α') phase separation is reported using atom probe tomography techniques. The extent of phase separation, i.e., amplitude and wavelength, has been quantitatively assessed using the Langer-Bar-on-Miller, proximity histogram, and autocorrelation function methods for two separate Fe–Cr alloys, designated 2101 and 2205. Although the 2101 alloy possesses a larger wavelength and amplitude after annealing at 427 °C for 100–10 000 h, it exhibits a lower hardness than the 2205 alloy. In addition to this phase separation, ultra-fine Ni–Mn–Si–Cu-rich G-phase precipitates form at the α/α' interfaces in both alloys. For the 2101 alloy, Cu clusters act to form a nucleus, around which a Ni–Mn–Si shell develops during the precipitation process. For the 2205 alloy, the Ni and Cu atoms enrich simultaneously and no core–shell chemical distribution was found. This segregation phenomenon may arise from the exact Ni/Cu ratio inside the ferrite. After annealing for 10 000 h, the number density of the G-phase within the 2205 alloy was found to be roughly one order of magnitude higher than in the 2101 alloy. The G-phase precipitates have an additional deleterious effect on the thermal embrittlement, as evaluated by the Ashby–Orowan equation, which explains the discrepancy between the hardness and the rate of phase separation with respect to annealing time (Gladman T 1999 Mater. Sci. Tech. Ser. 15 30–36).

36 MATERIALS SCIENCE↗