Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantitative analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Mammographic quantitative image analysis and biologic image composition for breast lesion characterization and classification

Purpose: To investigate whether biologic image composition of mammographic lesions can improve upon existing mammographic quantitative image analysis (QIA) in estimating the probability of malignancy. Methods: The study population consisted of 45 breast lesions imaged with dual-energy mammography prior to breast biopsy with final diagnosis resulting in 10 invasive ductal carcinomas, 5 ductal carcinomain situ, 11 fibroadenomas, and 19 other benign diagnoses. Analysis was threefold: (1) The raw low-energy mammographic images were analyzed with an established in-house QIA method, “QIA alone,” (2) the three-compartment breast (3CB) composition measure—derived from the dual-energy mammography—of water, lipid, and protein thickness were assessed, “3CB alone”, and (3) information from QIA and 3CB was combined, “QIA + 3CB.” Analysis was initiated from radiologist-indicated lesion centers and was otherwise fully automated. Steps of the QIA and 3CB methods were lesion segmentation, characterization, and subsequent classification for malignancy in leave-one-case-out cross-validation. Performance assessment included box plots, Bland–Altman plots, and Receiver Operating Characteristic (ROC) analysis. Results: The area under the ROC curve (AUC) for distinguishing between benign and malignant lesions (invasive and DCIS) was 0.81 (standard error 0.07) for the “QIA alone” method, 0.72 (0.07) for “3CB alone” method, and 0.86 (0.04) for “QIA+3CB” combined. The difference in AUC was 0.043 between “QIA + 3CB” and “QIA alone” but failed to reach statistical significance (95% confidence interval [–0.17 to + 0.26]). Conclusions: In this pilot study analyzing the new 3CB imaging modality, knowledge of the composition of breast lesions and their periphery appeared additive in combination with existing mammographic QIA methods for the distinction between different benign and malignant lesion types.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative Proteomic Analysis of Mass Limited Tissue Samples for Spatially Resolved Tissue Profiling

Traditionally, proteomic studies have been carried out on whole tissues or organs enabling the profiling of thousands of proteins within a single LC-MS analysis. A disadvantage of this approach is that proteomes generated from whole tissues are an “average” that represents a blend of cell types and distinct anatomical regions which can obscure important biological phenomena. Laser capture microdissection (LCM) is an elegant method that allows tissue features of interest, as small as a single cell, to be identified and isolated for downstream analysis. Herein we describe an approach that utilizes an immobilized enzyme reactor (IMER) coupled directly to nanoLC-MS/MS for highly sensitive, automated, quantitative proteomic analysis of the microscopic tissue specimens generated by LCM.

Piehowski, Paul D.↗

Affine Transformations to Enable Machine Learning for Semi-Quantitative EDS Analysis

Energy Dispersive X-ray Spectroscopy (EDS) is an essential technique for determining elemental concentrations and distributions within microstructures, critical for materials discovery, optimization, and qualification. However, most published EDS data is qualitative because current quantitative EDS analysis methods require extensive calibration and post-processing, limiting their practicality and widespread adoption. This work seeks to establish a framework for accelerated EDS characterization and spectrum analysis that can leverage ML to analyze correlations between various elemental compositions and resulting EDS spectra. The complex physics and data result in a high-dimensional problem that grows exponentially with the number of elements in the system and the complexity of the spectrum analysis. ML provides a way to compute and optimize the results of this highly dimensional problem in a flexible way to tailor it to the user’s specific needs and material system. However, the framework emphasizes transparency through a strictly mathematical affine transformation, so the analysis remains understandable and reviewable to facilitate adoption by the scientific community. While currently implemented methods are simplistic and unvalidated, further development and demonstration of this framework could enable high-throughput, accurate, and accessible EDS characterization.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Identification of Salmonella Typhimurium deubiquitinase SseL substrates by immunoaffinity enrichment and quantitative proteomic analysis

Ubiquitination is a key protein post-translational modification that regulates many important cellular pathways and whose levels are regulated by equilibrium between the activities of ubiquitin ligases and deubiquitinases. Here we present a method to identify specific deubiquitinase substrates based on treatment of cell lysates with recombinant enzymes, immunoaffinity purification and global quantitative proteomic analysis. As model system to identify substrates, we used a virulence-related deubiquitinase secreted by Salmonella enterica serovar Typhimurium into the host cells, SseL. By using this approach two SseL substrates were identified in RAW 264.7 murine macrophage-like cell line, S100A6 and het-erogeneous nuclear ribonuclear protein K, in addition to the previously reported K63-linked ubiquitin chains. These substrates were further validated by a combination of enzymatic and binding assays. Finally, this method can be used for the systematic identification of substrates of deubiquitinases from other organisms and applied to study their functions in physiology and disease.

59 BASIC BIOLOGICAL SCIENCES↗

Anniversary Paper: History and status of CAD and quantitative image analysis: The role of Medical Physics and AAPM

The roles of physicists in medical imaging have expanded over the years, from the study of imaging systems (sources and detectors) and dose to the assessment of image quality and perception, the development of image processing techniques, and the development of image analysis methods to assist in detection and diagnosis. The latter is a natural extension of medical physicists' goals in developing imaging techniques to help physicians acquire diagnostic information and improve clinical decisions. Studies indicate that radiologists do not detect all abnormalities on images that are visible on retrospective review, and they do not always correctly characterize abnormalities that are found. Since the 1950s, the potential use of computers had been considered for analysis of radiographic abnormalities. In the mid-1980s, however, medical physicists and radiologists began major research efforts for computer-aided detection or computer-aided diagnosis (CAD), that is, using the computer output as an aid to radiologists--as opposed to a completely automatic computer interpretation--focusing initially on methods for the detection of lesions on chest radiographs and mammograms. Since then, extensive investigations of computerized image analysis for detection or diagnosis of abnormalities in a variety of 2D and 3D medical images have been conducted. The growth of CAD over the past 20 years has been tremendous--from the early days of time-consuming film digitization and CPU-intensive computations on a limited number of cases to its current status in which developed CAD approaches are evaluated rigorously on large clinically relevant databases. CAD research by medical physicists includes many aspects--collecting relevant normal and pathological cases; developing computer algorithms appropriate for the medical interpretation task including those for segmentation, feature extraction, and classifier design; developing methodology for assessing CAD performance; validating the algorithms using appropriate cases to measure performance and robustness; conducting observer studies with which to evaluate radiologists in the diagnostic task without and with the use of the computer aid; and ultimately assessing performance with a clinical trial. Medical physicists also have an important role in quantitative imaging, by validating the quantitative integrity of scanners and developing imaging techniques, and image analysis tools that extract quantitative data in a more accurate and automated fashion. As imaging systems become more complex and the need for better quantitative information from images grows, the future includes the combined research efforts from physicists working in CAD with those working on quantitative imaging systems to readily yield information on morphology, function, molecular structure, and more--from animal imaging research to clinical patient care. A historical review of CAD and a discussion of challenges for the future are presented here, along with the extension to quantitative image analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatially resolved absolute quantitation in thin tissue by mass spectrometry

Mass spectrometry (MS) has become the de facto tool for routine quantitative analysis of biomolecules. MS is increasingly being used to reveal the spatial distribution of proteins, metabolites, and pharmaceuticals in tissue and interest in this area has led to a number of novel spatially resolved MS technologies. Most spatially resolved MS measurements are qualitative in nature due to a myriad of potential biases, such as sample heterogeneity, sampling artifacts, and ionization effects. As applications of spatially resolved MS in the pharmacological and clinical fields increase, demand has become high for quantitative MS imaging and profiling data. As a result, several varied technologies now exist that provide differing levels of spatial and quantitative information. Furthermore, this review provides an overview of MS profiling and imaging technologies that have demonstrated quantitative analysis from tissue. Focus is given on the fundamental processes affecting quantitative analysis in an array of MS imaging and profiling technologies and methods to address these biases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative Uncertainty Analysis for Diffraction

Current software uses a least squares statistical method. For each model parameter, current software yields a point estimate and estimated standard error for each point estimate. In contrast, we have employed a Bayesian approach with sampling algorithm to provide a full posterior probability density function on each model parameter. This yields a different type of solution (probabilistic) with better fidelity. The Quantitative Uncertainty Analysis for Diffraction (QUAD) package returns a matrix of affect model parameters as a function of iteration through the MCMC analysis. QUAD is a Python code that allows for analysis of X-ray and neutron diffraction data to infer the structure of materials with quantifiable certainty. The code uses Bayesian statistics and Markov chain sampling algorithms to create posterior probability distributions on all material structure parameters that are modeled by a researcher. The statistical packages use the open source GSASII project as a library to calculate model diffraction patterns.

Fancher, ChristopherM↗

Evidence of an oxidation induced phase transformation for a delta phase plutonium-gallium alloy

The oxidation of an ~1.5 at% Ga plutonium metal alloy in dry air as a function of time was studied using a combination of FIB-SEM, AES, and XRD. Analysis of SEM images of FIB cross-sections of the oxide allowed for direct measurement of the oxide thickness as well as determination of heterogeneity in the extent of the oxide. AES analysis performed on cross-sections of the oxide allowed for quantitative analysis of the atomic composition and semi-quantitative analysis of the chemical composition. Initial preparation of the sample was found to induce a martensitic transformation to α' - Pu with an average thickness of 233 nm. Electropolishing was found to be sufficient to fully remove the α' layer with creation of only a minimum oxide layer. Growth of the oxide in dry air was found to initially follow parabolic kinetics, with a parabolic rate constant orders of magnitude higher than expected for δ-Pu but in-line with values extrapolated to room temperature for α-Pu. Following complete oxidation of the initial α` layer, further regions of plutonium metal depleted in gallium were observed to form at the oxide / metal interface. However, gallium, as Ga 2 O 3 , was found to be enriched at the surface and present in the oxide in an amount comparable to the relative Ga:Pu ratio of the bulk metal alloy. Finally, the results presented here serve to bridge a diverse array of previous experimental and theoretical data and provide the first comprehensive view of the fate of the δ-stabilizer during formation of an oxide.

36 MATERIALS SCIENCE↗

Quantitative defect analysis in MOCVD GaN-on-GaN using cathodoluminescence

Cathodoluminescence (CL) is used as a quantitative characterization technique to probe impurities at the metal-organic chemical vapor deposition (MOCVD) grown GaN-on-GaN homoepitaxial interfaces. CL intensity contrast shows a strong correlation with the interfacial impurity concentrations. Based on the analysis of recombination mechanisms of electron beam induced non-equilibrium carriers, an analytical model is proposed to quantitatively determine the impurity concentrations from CL intensity. The extracted interfacial impurity concentrations from the analytical model show a good agreement with the compensation levels obtained from capacitance-voltage measurement, signifying the potential of CL for probing the quantitative impurity levels in GaN-on-GaN structures. This approach can also be extended to be applied in other material systems.

Chen, Zhaoying↗

Applying Graph Analytics to Understand Compute Core Usage and Publication Trends in a Petascale Supercomputing Facility

The Oak Ridge Leadership Computing Facility (OLCF) runs Titan, the No. 4 supercomputer in the world, to deliver over four billion compute core hours every year to several scientific domains, in their pursuit of leadership science. In this paper, we analyze four years worth of heterogeneous log data sources from the OLCF resource fabric, capturing metadata on entities such as users (2,546), scientific project allocations (674), jobs (1,352,402) and publications (1,146), to derive insights into the trends in core hour usage and publications, across 35 science domains. We have constructed a scalable graph to represent the OLCF entities and apply rich graph analytics for our analysis. Based on this, we have analyzed the metadata across five dimensions, namely (1) quantitative analysis of Titan system usage, (2) quantitative analysis of OLCF publications, (3) correlation analysis between system usage and publications, (4) text analysis to derive OLCF research trends, and (5) utilization of graph mining for association analysis. To the best of our knowledge, our work is the first of its kind to apply graph- based big data techniques to provide comprehensive insights on an HPC center's core hour usage and users' publication trends. Our results provide valuable details into an HPC center's core allocation program, measuring the productivity of scientific domains, the interplay between core usage and research output, accelerating collaboration, and in predicting new connections between resource entities.

Lee, Sangkeun (Matt)↗

Improved Protein Arrays for Quantitative Systems Analysis of the Dynamics of Signaling Pathway Interactions

Astronauts and workers in nuclear plants who repeatedly exposed to low doses of ionizing radiation (IR, <10 cGy) are likely to incur specific changes in signal transduction and gene expression in various tissues of their body. Remarkable advances in high throughput genomics and proteomics technologies enable researchers to broaden their focus from examining single gene/protein kinetics to better understanding global gene/protein expression profiling and biological pathway analyses, namely Systems Biology. An ultimate goal of systems biology is to develop dynamic mathematical models of interacting biological systems capable of simulating living systems in a computer. This Glue Grant is to complement Dr. Boothman’s existing DOE grant (No. DE-FG02-06ER64186) entitled “The IGF1/IGF-1R-MAPK-Secretory Clusterin (sCLU) Pathway: Mediator of a Low Dose IR-Inducible Bystander Effect” to develop sensitive and quantitative proteomic technology that suitable for low dose radiobiology researches. An improved version of quantitative protein array platform utilizing linear Quantum dot signaling for systematically measuring protein levels and phosphorylation states for systems biology modeling is presented. The signals are amplified by a confocal laser Quantum dot scanner resulting in ~1000-fold more sensitivity than traditional Western blots and show the good linearity that is impossible for the signals of HRP-amplification. Therefore this improved protein array technology is suitable to detect weak responses of low dose radiation. Software is developed to facilitate the quantitative readout of signaling network activities. Kinetics of EGFRvIII mutant signaling was analyzed to quantify cross-talks between EGFR and other signaling pathways.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reinforcement Mechanism Of Polyurethane-Urea/Clay Nanocomposites Probed By Positron Annihilation Lifetime Spectroscopy And Dynamic Mechanical Analysis

A basis for quantitative analysis of the reinforcement mechanism of polyurethane-urea/clay nanocomposites using two characterization methods, positron annihilation life time spectroscopy (PALS) and dynamic mechanical analysis (DMA) is provided. DMA was used to measure the constrained volume fraction of amorphous soft segments induced by nanoclay and the storage modulus of the nanocomposites. The interfacial interactions in the nanocomposites were investigated by PALS. The modulus enhancement of the organoclay nanocomposites was found to have a good correlation with the volume fraction of the constrained region and the interfacial interactions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Single Quadrupole Multiple Fragment Ion Monitoring Quantitative Mass Spectrometry

Single quadrupole mass spectrometry (MS) with enhanced in-source multiple fragment ion monitoring was designed to perform high sensitivity quantitative mass analyses. Enhanced in-source fragmentation amplifies fragmentation from traditional soft electrospray ionization producing fragment ions that have been found to be identical to those generated in tandem MS. We have combined enhanced in-source fragmentation data with criteria established by the European Union Commission Directive 2002/657/EC for electron ionization single quadrupole quantitative analysis to perform quantitative analyses. These experiments were performed on multiple types of complex samples that included a mixture of 50 standards, as well as cell and plasma extracts. The dynamic range for these quantitative analyses was comparable to triple quadrupole multiple reaction monitoring (MRM) analyses at up to 5 orders of magnitude with the cell and plasma extracts showing similar matrix effects across both platforms. Amino acid and fatty acid measurements performed from certified NIST 1950 plasma with isotopically labeled standards demonstrated accuracy in the range of 91–110% for the amino acids, 76–129% for the fatty acids, and good precision (coefficient of variation <10%). To enhance specificity, a newly developed correlated ion monitoring algorithm was designed to facilitate these analyses. This algorithm autonomously processes, aligns, filters, and compiles multiple ions within one chromatogram enabling both precursor and in-source fragment ions to be correlated within a single chromatogram, also enabling the detection of coeluting species based on precursor and fragment ion ratios. Single quadrupole instrumentation can provide MRM level quantitative performance by monitoring/correlating precursor and fragment ions facilitating high sensitivity analysis on existing single quadrupole instrumentation that are generally inexpensive, easy to operate, and technically less complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative Particle Analysis of Neptunium-237 Oxides: Optimization of MAMA Analysis for Modified Direct Denitration Products

The production of plutonium-238 through irradiation of neptunium-237 ( 237 Np) target materials for the use in radioisotope thermoelectric generators is paramount for continued deep space exploration. This work employs scanning electron microscopy to analyze 237 Np materials coupled with a well-developed image analysis framework (Morphological Analysis for Material Attribution, or MAMA) to determine the degree of micron-scale homogeneity in the materials. This work demonstrated how the quantification of particle characteristics can validate production materials and affirm the qualitative similarities observed in micrographs. The 237 Np oxide particle analysis determined that the materials from five production runs were quantitatively homogenous (significant at α = 0.05) in particle area, circularity, equivalent circular diameter, and ellipse aspect ratio, with two of the sampling dates having statistically significant different means for one of the four characteristics. Furthermore, these metrics not only confirm general homogeneity of the material but also expand the application of MAMA workflows to 237 Np materials, demonstrating the utility of MAMA analysis for a wider breadth of nuclear materials than previously reported. In the open literature, this study is the first time that these microanalytical techniques were applied to 237 Np materials to this degree.

MAMA↗

A Quantitative Failure Analysis on Capacity Fade in Rechargeable Lithium Metal Cells

Rechargeable lithium battery (RLB) technology is transforming portable devices, vehicle electrification, and grid modernization. To make RLB durable, reliable and safe, conducting failure mode and effect analysis (FMEA) to identify failure mechanism under the operating conditions is very desirable. However, this ability is often overlooked or even lacking. The failure analysis (FA) is often conducted by laboratory testing and postmortem analysis, and the knowledge typically empirical. Here we present a quantitative approach for FMEA that can reveal how failure modes and effects reduce the capacity of a RLB. This approach is based on the state of the battery for FMEA, contrary to the conventional approach based on operating or testing conditions. The key aspect of this FMEA method is to convert the experimental results to a state-of-charge (SOC)-based analytic methodology. Such a conversion can separate the thermodynamic and kinetic attributes of capacity fade based on compositional correspondence in the electrode, so the loss and the decreased utilization of the active materials can be determined respectively.

25 ENERGY STORAGE↗

Multivariate statistics applications in phase analysis of STEM-EDS spectrum images

Spectrum imaging (SI) methods are displacing traditional spot analyses as the predominant paradigm for spectroscopic analysis with electron beam instrumentation. The multivariate nature of SI provides clear advantages for qualitative analysis of multiphase specimens relative to traditional gray-scale images acquired with non-spectroscopic signals, where different phases with similar average atomic number may exhibit the same intensity. However, with the improvement in qualitative analysis with the SI paradigm has come a decline in the quantitative analysis of the phases thus identified, since the spectra from individual pixels typically have insufficient counting statistics for proper quantification. The present paper outlines a methodology for quantitative analysis within the spectral imaging paradigm, which is illustrated through X-ray energy-dispersive spectroscopy (EDS) of a multiphase (Pb,La)(Zr,Ti)O{sub 3} ceramic in scanning transmission electron microscopy (STEM). Statistical analysis of STEM-EDS SI is shown to identify the number of distinct phases in the analyzed specimen and to provide better segmentation than the STEM high-angle annular dark-field (HAADF) signal. Representative spectra for the identified phases are extracted from the segmented images with and without exclusion of pixels that exhibit spectral contributions from multiple phases, and subsequently quantified using Cliff-Lorimer sensitivity factors. The phase compositions extracted with the method while excluding pixels from multiple phases are found to be in good agreement with those extracted from user-selected regions of interest, while providing improved confidence intervals. Without exclusion of multiphase pixels, the extracted composition is found to be in poor statistical agreement with the other results because of systematic errors arising from the cross-phase spectral contamination. The proposed method allows quantification to be performed in the presence of discontinuous phase distributions and overlapping phases, challenges that are typical of many nanoscale analyses performed by STEM-EDS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Use of local noise power spectrum and wavelet analysis in quantitative image quality assurance for EPIDs

Purpose: To investigate the use of local noise power spectrum (NPS) to characterize image noise and wavelet analysis to isolate defective pixels and inter-subpanel flat-fielding artifacts for quantitative quality assurance (QA) of electronic portal imaging devices (EPIDs). Methods: A total of 93 image sets including custom-made bar-pattern images and open exposure images were collected from four iViewGT a-Si EPID systems over three years. Global quantitative metrics such as modulation transform function (MTF), NPS, and detective quantum efficiency (DQE) were computed for each image set. Local NPS was also calculated for individual subpanels by sampling region of interests within each subpanel of the EPID. The 1D NPS, obtained by radially averaging the 2D NPS, was fitted to a power-law function. The r-square value of the linear regression analysis was used as a singular metric to characterize the noise properties of individual subpanels of the EPID. The sensitivity of the local NPS was first compared with the global quantitative metrics using historical image sets. It was then compared with two commonly used commercial QA systems with images collected after applying two different EPID calibration methods (single-level gain and multilevel gain). To detect isolated defective pixels and inter-subpanel flat-fielding artifacts, Haar wavelet transform was applied on the images. Results: Global quantitative metrics including MTF, NPS, and DQE showed little change over the period of data collection. On the contrary, a strong correlation between the local NPS (r-square values) and the variation of the EPID noise condition was observed. The local NPS analysis indicated image quality improvement with the r-square values increased from 0.80 ± 0.03 (before calibration) to 0.85 ± 0.03 (after single-level gain calibration) and to 0.96 ± 0.03 (after multilevel gain calibration), while the commercial QA systems failed to distinguish the image quality improvement between the two calibration methods. With wavelet analysis, defective pixels and inter-subpanel flat-fielding artifacts were clearly identified as spikes after thresholding the inversely transformed images. Conclusions: The proposed local NPS (r-square values) showed superior sensitivity to the noise level variations of individual subpanels compared with global quantitative metrics such as MTF, NPS, and DQE. Wavelet analysis was effective in detecting isolated defective pixels and inter-subpanel flat-fielding artifacts. The proposed methods are promising for the early detection of imaging artifacts of EPIDs.

60 APPLIED LIFE SCIENCES↗

Quality Assessments of Long-Term Quantitative Proteomic Analysis of Breast Cancer Xenograft Tissues

The identification of protein biomarkers requires large-scale analysis of human specimens to achieve statistical significance. In this study, we evaluated the long-term reproducibility of an iTRAQ (isobaric tags for relative and absolute quantification) based quantitative proteomics strategy using one channel for universal normalization across all samples. A total of 307 liquid chromatography tandem mass spectrometric (LC-MS/MS) analyses were completed, generating 107 one-dimensional (1D) LC-MS/MS datasets and 8 offline two-dimensional (2D) LC-MS/MS datasets (25 fractions for each set) for human-in-mouse breast cancer xenograft tissues representative of basal and luminal subtypes. Such large-scale studies require the implementation of robust metrics to assess the contributions of technical and biological variability in the qualitative and quantitative data. Accordingly, we developed a quantification confidence score based on the quality of each peptide-spectrum match (PSM) to remove quantification outliers from each analysis. After combining confidence score filtering and statistical analysis, reproducible protein identification and quantitative results were achieved from LC-MS/MS datasets collected over a 16 month period.

Environmental Molecular Sciences Laboratory↗