Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Connected Thermostat Alternatives for Room Air Conditioners and Minisplit Heat Pumps

The availability of smart, connected thermostats has improved climate control, energy efficiency, and grid demand-response programs for central HVAC systems. However, a significant gap exists in addressing integrated control systems for point-source heating and cooling systems such as window air-conditioners (window ACs) and mini-split heat pumps (MSHPs). This report examines the emerging market of third-party connected thermostats tailored for these systems, focusing on their effectiveness, reliability, and potential barriers to adoption.This study evaluates several commercially available products designed for room ACs and MSHPs through a series of laboratory tests. While these infrared-based (IR-based) thermostats offer remote temperature control and scheduling via mobile apps, our findings reveal that none are seamless, with reliability of basic functions being a critical factor. Promising features include integration of indoor air quality metrics and time-of-use pricing, but the latter are not yet available in the U.S. Barriers to broad user acceptance include non-seamless setup processes, challenges in thermostat placement, and unclear product differentiation. There is a pressing need for research and development in enabling MSHPs and central thermostats to coordinate, enhancing energy savings and comfort in retrofit applications. This study underscores the importance of further innovation in connected thermostat technology to address the diverse needs of single-zone HVAC systems and promote efficient energy management in households.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This document focuses on a single end-use savings shape measure: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER). This document builds on details established in the single-stage document (Maguire et al. 2025) to detail differences in the approach to modeling this higher efficiency, but more commonly deployed, type of geothermal heat pump. Specific EnergyPlus objects and product specific curves used are highlighted along with showing the results of this measure compared to the baseline and single-speed geothermal heat pumps. Two-speed geothermal heat pumps are able to save even more energy and on utility bills than single-speed products, albeit at the expense of a higher first cost.

15 GEOTHERMAL ENERGY↗

Variable spin-charge conversion across metal-insulator transition

The charge-to-spin conversion efficiency is a crucial parameter in determining the performance of many useful spintronic materials. Usually, this conversion efficiency is predetermined by the intrinsic nature of solid-state materials, which cannot be easily modified without invoking chemical or structural changes in the underlying system. Here we report on successful modulation of charge-spin conversion efficiency via the metal-insulator transition in a quintessential strongly correlated electron compound vanadium dioxide (VO2). By employing ferromagnetic resonance driven spin pumping and the inverse spin Hall effect measurement, we find a dramatic change in the spin pumping signal (decrease by > 80%) and charge-spin conversion efficiency (increase by five times) upon insulator to metal transition. The abrupt change in the structural and electrical properties of this material therefore provides useful insights on the spin related physics in a strongly correlated material undergoing a phase transition.

36 MATERIALS SCIENCE↗

Review of liquid desiccant air dehumidification systems coupled with heat pump: System configurations, component design, and performance

Vapor Compression Systems (VCS) are the most common air conditioning technology. VCS cool the air to its dew point temperature (overcooling) to remove water vapor in the air through condensation and then reheats the air back to the comfort temperature for direct use. The VCS process is inefficient due to overcooling and reheating. Liquid Desiccant Dehumidification (LDD) is a potentially energy-efficient air conditioning. LDD removes water vapor in the process air using liquid desiccant’s high-water affinity. It hybrids with sensible cooling to control temperature and humidity separately. The LD in the LDD becomes weak after dehumidification. The LDD needs additional heating to regenerate the weak Liquid Desiccant (LD) to a high concentration for dehumidification. Earlier versions of the LDD systems use highly concentrated liquid desiccant (large water removal capability) to dehumidify the air by only dealing with latent load. It leads to highly elevated temperatures above 60 °C of heat sources (combustion or electric resistance-based heating) for regeneration. The energy needed for the elevated temperature heat resource significantly reduces or demolishes the benefit of LDD systems. In the recent two decades, researchers have investigated a new configured LDD system that couples an LDD with a heat pump at both dehumidification and regeneration sides for better efficiency. The heat pump provides cooling (from the evaporator) for both dehumidification and sensible cooling and simultaneous heating from the condenser for regeneration. The highly integrated system (HP-LDD) with improved efficiency enables the LDD to operate at lower concentrations and temperatures in dehumidification and regeneration. This paper depicts the working principle behind HP-LDD and its heating and cooling requirements. It reviews the comparison between the HP-LDD systems and the conventional LDD systems regarding system configurations, component design, energy efficiency, and dehumidification performance characteristics. The main findings from the review include the preferred use of packed bed over membrane-based dehumidifiers, the use of internally cooled dehumidifiers enabled by the HP cooling capacity, the high dispersion of HP operation conditions, and the dependence of dehumidification performance on various dehumidifiers. Finally, an outlook for future research on HP-LDD strategies is presented based on the reviewed works and their limitations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Overcoming energy limitation in post-compression of picosecond pulses by free beam propagation in air and temporal pulse splitting and recombining

Cryogenically cooled diode-pumped Yb:YAG has been demonstrated to efficiently generate pulses of >1 J energy and several picoseconds duration at a kilohertz repetition rate. Pulse broadening and post-compression techniques capable of operating at these high pulse energies will expand the use of these lasers in applications requiring shorter pulses. Towards this goal, we demonstrate the post-compression of 5.5 ps pulses with energy in the 0.1 J range by spectral broadening of self-collimated large area beams in air. In proof-of-principle experiments, pulses of 65 mJ energy from a cryogenically cooled Yb:YAG laser were compressed to 1.1 ps after 65 m propagation in a compact setup in which the beam was folded using flat mirrors. Further energy scaling was demonstrated by combining this spectral broadening technique with temporal pulse splitting and recombining. 120 mJ pulses were split into two pulses and coherently recombined with 85% efficiency after 50 m of propagation in air to yield 1.4 ps pulses.

High Energy Laser↗

High Performance Green LEDs for Solid State Lighting

The development of white LEDs for solid state lighting (SSL) has been driven in recent years by phosphor converted LEDs (pc-LEDs). However, losses (known as Stokes’ losses) between the blue pump LED and phosphor impose a fundamental efficiency limit of ~300 lm/W on pc-LEDs. White light can also be generated from color mixed LEDs (cm-LEDs), which employ red, green, blue, and amber LEDs and have a fundamental efficiency limit of ~400 lm/W. Efficient group III-nitride materials are used for the blue LED, while efficient group III-phosphide materials are used for the red LED component. Currently, the poor efficiency of green and amber LEDs (i.e. the “green gap”) is the primary limitation for cm-LEDs. Relative to nitride-based blue LEDs, green and amber nitride LEDs suffer from lower radiative recombination rates and higher nonradiative recombination rates, which ultimately lead to reduced internal quantum efficiency (IQE). The IQE represents the portion of all electron-hole recombination events that result in a photon. In addition, long-wavelength LEDs have lower electrical efficiency (EE) compared to their blue counterparts. Addressing the green gap, would ultimately enable cm-LEDs that rival or exceed the performance of pc-LEDs. Our project focused on III-nitride materials growth and characterization, device fabrication and testing, and semiconductor physics to understand efficiency limitations of green LEDs and develop solutions to these challenges. Insights gained during our research has led to novel long-wavelength LED designs which will enable efficient solid-state lighting.

30 DIRECT ENERGY CONVERSION↗

Process Heating Assessments Using DOE’s Manufacturing Energy Assessment Software for Utility Reduction (MEASUR) Tool Suite

Process heating is the most energy-intensive manufacturing process for most sectors of industry. To quantify energy savings from various energy conservation measures, the Department of Energy (DOE) sponsored the development of the Process Heating Assessment and Survey Tool (PHAST) and similar tools for other industrial systems in the early 2000s. It has been used extensively in the Save Energy Now Program’s Energy Savings Assessments and the Better Plants Program’s In-Plant Trainings. Since the initial development of the legacy tools, both computer operating systems and software development have evolved significantly. Thus, DOE has invested in the modernization of PHAST and other legacy software tools to create the Manufacturing Energy Assessment Software for Utility Reduction (MEASUR) tool suite. MEASUR offers a collection of software tools that can aid manufacturing facilities in improving the efficiency of energy systems and equipment (specifically pumps, fans, steam, and process heating) and in conducting “Energy Treasure Hunts”. Eventually, the tool will also add compressed air and process cooling systems. The Process Heating Assessment (PHA) module of MEASUR is an upgrade of the PHAST tool. PHA provides the means to model fuel-fired, steam-based, and electric process heating systems, covering process heating for most industrial plants in manufacturing sector. It also includes several key upgrades, including the ability to consider multi-component charge loads and account for several different areas of energy losses. The new tool includes a comprehensive flue gas calculator to quantify available heat and heat loss for various gaseous, liquid, and solid fuels and new heat loss calculators. It generates a report and a dynamic Sankey diagram to show the energy consumption in various areas of energy use. MEASUR has significantly improved the user experience by adopting a modern software design. This paper details the structure and workflow of PHA and presents a real-world case study to demonstrate energy savings quantification and MEASUR’s outstanding reporting capabilities.

Nimbalkar, Sachin U.↗

Experimental Study on Charging and Discharging Performance of a Dual-Purpose Underground Thermal Battery

A dual-purpose underground thermal battery (DPUTB) was proposed for Grid-interactive Efficient Buildings. It integrates underground thermal energy storage with a shallow-buried ground heat exchanger (less than 6 m deep). The charging and discharging performance of a lab-scale DPUTB were experimentally investigated. The test results show that the lab-scale (1:125 in volume) DPUTB can provide 34 W cooling continuously for 3.7 h with a supply water temperature below 14°C. The water temperature rise of the inner tank was slowed down during the discharging process due to the phase change of the phase change material (PCM). Thermal storage capacity was increased by 156% using the PCM that only occupied 19% volume of the inner tank. The heat lost from the inner tank was recovered in the outer tank and led to the efficiency improvement of a ground source heat pump.

Wang, Lingshi↗

Performance Modeling of a Thermoelectric Heat Pump Clothes Dryer with Very High Air Flow

Previous research has shown that a clothes dryer heated by thermoelectric (Peltier) heat pumps can be up to 85% more efficient than a conventional electric-resistance dryer. A previous thermoelectric prototype used a conventional dryer’s air flow of 120 ft3/min (0.06 m3/s) and provided about 1,300 W of thermoelectric heating capacity at a heating coefficient of performance (COP) of approximately 1.2. In this work, the performance of a clothes dryer with a very high air flow rate, up to 300 ft3/min (1.14 m3/s), and only 400 W of thermoelectric heating capacity was investigated using a thermohydraulic model. Key aspects of the model were validated experimentally. Results for dry time and efficiency are presented for various air flow and heating rates.

Boudreaux, Philip↗

Monitoring Based Commissioning: Step-by-Step Approach to Implementation in Chiller Plants

Chilled water systems consume a significant portion of the energy in manufacturing, and inefficient operation could significantly influence utility bills and the environmental footprint of a facility. One way to ensure long-term energy-efficient plant operation is to ensure that chilled water system equipment, such as chillers, cooling towers, and pumps, are running at their best. Periodic operational assessments help to meet efficiency objectives for cooling plants. However, occasional set point and operational changes resulting from short-term fluctuations cause the plant operation to deviate from optimal. These changes accumulate over time, and operational efficiency deteriorates. Significant energy efficiency improvement potential in chilled water systems can be achieved by operational changes alone. Recent developments in information technology and the industrial internet of things data processing ability have overcome traditional problems and given rise to a new paradigm: monitoring-based commissioning (MBCx). Commissioning platforms and fault detection and diagnostics capabilities have evolved over time and presented more sophisticated abilities to efficiently control process cooling plants. The typical architectures of the MBCx process and a detailed approach to implement the process for chilled water systems are presented. A case study highlighting the energy-and cost-savings potential of MBCx systems is also presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Split HPWHs as an Efficient Solution for Multifamily Buildings with In-Unit Water Heaters

A quarter of all housing units in the United States are found in multifamily buildings, but few efficiency innovations have been made to improve electric water heating systems in this building type. Domestic hot water in multifamily buildings can either be provided by a large central water heater or smaller in-unit water heaters. Integrated heat pump water heaters that are installed in single-family homes are often a poor fit for individual multifamily units because the water heaters are often located in small internal closets. This confined space can limit the airflow to the heat pump, and the cold exhaust air can cause discomfort and reduced efficiency. Split CO2 HPWHs separate the tank from the heat pump, which allows for installation location flexibility. Further, CO2 heat pumps can operate under colder ambient conditions, making them a better fit for multifamily units across a wide range of climate regions. As part of a larger project to characterize split HPWH performance, we evaluated the feasibility of installing an additional, parallel tank that could provide hot water to a second housing unit using a single CO2 heat pump. This approach would reduce the first costs of these more expensive units. Based on the high draw volume that we imposed on both tanks, the same heat pump may be able to support more tanks, depending on hot water usage. This paper will describe the split CO2 HPWH technology, how the two-tank system was controlled, and results from our laboratory evaluation.

CO2 HPWH↗

Split HPWHs as an Efficient Solution for Multifamily Buildings with In-Unit Water Heaters: Preprint

A quarter of all housing units in the country are found in multifamily buildings but few efficiency innovations have been made to improve electric water heating systems in this building type. Domestic hot water in multifamily buildings can either be provided by a large central water heater or smaller in-unit water heaters. Integrated heat pump water heaters that are installed in single family homes are often a poor fit for individual multifamily units since the water heaters are often located in small internal closets. This confined space can limit the air flow to the heat pump and the cold exhaust air can cause discomfort and reduced efficiency. Split CO2 HPWHs separate the tank from the heat pump, which allows for installation location flexibility. Further, CO2 heat pumps can operate under colder ambient conditions, making them a better fit for multifamily units across a wide range of climate regions. As part of a larger project to characterize split HPWH performance, we evaluated the feasibility of installing an additional, parallel tank that could provide hot water to a second housing unit using a single CO2 heat pump. This approach would reduce the first costs of these more expensive units. Based on the high draw volume that we imposed on both tanks, the same heat pump may be able to support more tanks, depending on hot water usage. This paper will describe the split CO2 HPWH technology, how the two-tank system was controlled, and results from our laboratory evaluation.

CO2 HPWH↗

Thermalization of Fluorescent Protein Exciton–Polaritons at Room Temperature

Fluorescent proteins (FPs) have recently emerged as a serious contender for realizing ultralow threshold room temperature exciton–polariton condensation and lasing. Here, this contribution investigates the thermalization of FP microcavity exciton–polaritons upon optical pumping under ambient conditions. Polariton cooling is realized using a new FP molecule, called mScarlet, coupled strongly to the optical modes in a Fabry–Pérot cavity. Interestingly, at the threshold excitation energy (fluence) of ≈9 nJ per pulse (15.6 mJ cm –2 ), an effective temperature is observed, T eff ≈ 350 ± 35 K close to the lattice temperature indicative of strongly thermalized exciton–polaritons at equilibrium. This efficient thermalization results from the interplay of radiative pumping facilitated by the energetics of the lower polariton branch and the cavity Q-factor. Direct evidence for dramatic switching from an equilibrium state into a metastable state is observed for the organic cavity polariton device at room temperature via deviation from the Maxwell–Boltzmann statistics at k || = 0 above the threshold. Thermalized polariton gases in organic systems at equilibrium hold substantial promise for designing room temperature polaritonic circuits, switches, and lattices for analog simulation.

36 MATERIALS SCIENCE↗

Energy Model to Evaluate Thermal Energy Storage Integrated with Air Source Heat Pumps: Preprint

Full decarbonization in buildings requires the replacement of combustion appliances with electric ones, and air source heat pumps (ASHP) are a candidate alternative. However, technical limitations, such as the efficiency decrease when operating in cold weather, limit their adoption in the global heating market. Among several options to improve ASHP efficiency operating in colder climates, thermal energy storage (TES) has been considered, as it may provide heating when it is cold and shift ASHP operation to times when the weather is warmer. It may also take advantage of time of use electricity rates and support defrosting when necessary. The evaluation of ASHP-TES systems, however, is still limited because traditional metrics do not capture their full economic and environmental benefits. In this work, a python framework is presented to model the ASHP with and without the presence of TES. Metrics are proposed to analyze the system performance in terms of costs, equivalent CO2 emission, and efficiency metrics to evaluate and compare alternative systems. Model validation against experimental data obtained for a commercial heat pump is provided, as well as an application example using Denver, Colorado, to highlight the model capabilities.

cold climate↗

Antiferromagnetic Parametric Resonance Driven by Voltage-Controlled Magnetic Anisotropy

Voltage-controlled magnetic anisotropy (VCMA) is a low-energy alternative to manipulate the ferromagnetic state, which has been recently also considered in antiferromagnets (AFMs). Here, we theoretically demonstrate that VCMA can be used to excite linear and parametric resonant modes in easy-axis AFMs with perpendicular anisotropy, thus opening the way for an efficient electrical control of the Néel vector and for the detection of high-frequency dynamics. Our work leads to two key results: (i) VCMA parametric pumping experiences the so-called “exchange enhancement” of the coupling efficiency and, thus, is 1–2 orders of magnitude more efficient than microwave magnetic fields or spin-orbit torques, and (ii) it also allows for zero-field parametric resonance, which cannot be achieved by other parametric pumping mechanisms in AFMs with an out-of-plane easy axis. Therefore, we demonstrate that VCMA parametric pumping is the most promising method for coherent excitation and manipulation of AFM order in perpendicular easy-axis AFMs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) with Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deployable Element Ultra-High Vacuum Pump

Advancing Ultra High Vacuum (UHV) Pumping Technology: The deployable UHV pump team has designed a theoretical model to boost efficiency in high vacuum environments. Traditional systems face challenges with random molecular motion. The innovative windmill design, using titanium sublimation technology, reduces randomness by deploying a gettering surface that actively captures particles. This marks a notable advancement in UHV pumping technology.

43 PARTICLE ACCELERATORS↗