Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “process cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Vendor-Independent Design Requirements for a Boiling Water Reactor Safety System Upgrade

This Vendor-Independent License Amendment Request (LAR) Framework Document is a research product developed for the Idaho National Laboratory Light Water Reactor Sustainability (LWRS) Program. It was developed by MPR Associates, Inc. with technical input from LWRS and Exelon Generation personnel. To accomplish the purpose of this research, an operating plant (Limerick Generating Station [LGS]) was used as a reference to provide a concrete example and to present a "top-down" view of design concepts consistent with functional requirements baseline documents (references X and Y) also developed for this research. While this document is written in a framework to support a complete LAR submittal, its purpose is to communicate research concepts and provide an example of how to present digital information necessary to address expectations with regard to leveraging the Alternate Review Process as provided in Digital Instrumentation and Controls Interim Staff Guidance #06, Revision 2, Licensing Process. To leverage that process, this research document presupposes that a utility would select a vendor platform which has been prequalified for safety-related by the United States Nuclear Regulatory Commission. While this document is written using the Exelon Generation Limerick Generating Station (LGS) Units 1 and 2 as a baseline, this document is a research product. This document contains no commitments and makes no binding design decisions for Exelon Generation. Exelon Generation is leveraging this research to support their in-progress LGS Plant Protection System (PPS) upgrade efforts and plans to leverage it for their Redundant Reactor Control System (RRCS) replacement. The LWRS Program appreciates the research support provided by Exelon Generation in the generation of this document.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

West Virginia University Industrial Assessment Center (Final Progress Report)

The Industrial Assessment Center at West Virginia University has been successful in workforce development, and in generation of energy savings for manufacturing facilities during the period 2016 to 2021. Graduate and undergraduate students have benefited from energy assessment experience and most of them have found good positions as energy engineers and analysts in the industrial sector. Several peer reviewed research papers in archival journals as well as conference papers on the topic of energy engineering and assessment have been published. The implemented energy savings for manufacturing facilities have been significant in the areas of lighting, compressed air, process heating, steam, HVAC, chillers and cooling towers, and motors. In addition, water use reduction, smart manufacturing applications to save energy, cyber security evaluation, energy management, productivity improvements and waste reduction opportunities that lead to energy intensity reductions have been explored. The students have obtained an opportunity to interact with energy efficiency and productivity improvement professionals at various conferences and workshops and their research has generated important results. In summary, the West Virginia University Industrial Assessment Center (WVU-IAC) has fulfilled its mission in regard to workforce development, energy efficiency for manufacturing facilities, and laid a strong platform enhancing sustainability through reductions in carbon emissions achieved through energy efficiency and energy management initiatives and reductions in water usage and waste reduction. During the project period (2016-2021) the WVU-IAC has made numerous energy efficiency, water use reduction, waste reduction, and productivity improvement recommendations, a significant number of them having been implemented by the manufacturing facilities. The research adds significant understanding to the area of energy efficiency, water and waste reduction, and productivity improvement. The technical effectiveness and economic feasibility of the methods and techniques investigated and demonstrated through this project have been exemplary, resulting in significant recommended and implemented resource savings and reductions in carbon emissions. The project has been of significant benefit to the public owing to replication of results within the industrial sector, thus reducing operating costs for businesses that result in increase of growth and employment, as well as community benefits in terms of reductions in carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TRACER-Uncrewed Aircraft System (TRACER-UAS) Field Campaign Report

Convective processes drive the development of clouds across a variety of scales, thereby playing a central role in governing weather and climate globally. These processes help to set the stage for circulations that redistribute heat and moisture throughout the lower atmosphere, and simultaneously develop storms that supply precipitation to regions that depend on such rain events for supporting a variety of societal needs. At the same time, extreme precipitation events can result in localized flooding of low-lying areas, posing hazards to transportation and regional inhabitants, and potentially damaging structures and infrastructure. As a result, there is an inherent need to better understand the drivers and modulators of clouds and precipitation and leverage such understanding to make projections of how these important systems may evolve with a changing climate. With nearly three billion of Earth’s human inhabitants living within 200 km of a shoreline, development of such understanding is particularly important in coastal regimes. Central drivers of convective cloud development and life cycle in coastal environments include synoptic forcing, local meso- and microscale circulation regimes, microphysical evolution, and aerosol properties. Atmospheric boundary layer (ABL) development and its evolution can help drive the formation and organization of convective clouds, which then impart their own controls through dynamic processes related to latent heating and cooling (including cold-pool formation and propagation), three-dimensional radiative effects, and background environmental conditions (Fan et al. 2016). Such clouds have been contributing to record precipitation events in southeast Texas in recent years, relative to the last several decades of data from regional precipitation gauges (Fagnant et al. 2020). The greater Houston urban area has experienced particularly large increases in the frequency of extreme rainfall events, with enhanced intensity of extreme events (stretching of distribution tails) having potentially significant implications for watershed floodplain planning and mapping in greater Houston and Harris County. While the most extreme precipitation events were associated with tropical cyclones (e.g., Tropical Storm Allison and Hurricane Harvey; Blood 2014, Kao et al. 2019), strong thunderstorms can also deliver large amounts of precipitation over the area over relatively short periods.

54 ENVIRONMENTAL SCIENCES↗

Quality Assurance Program Plan for SFR Metallic Fuel Data Qualification

This document contains an evaluation of the applicability of the current Quality Assurance Standards from the American Society of Mechanical Engineers Standard NQA-1 (NQA-1) criteria and identifies and describes the quality assurance process(es) by which attributes of historical, analytical, and other data associated with sodium-cooled fast reactor [SFR] metallic fuel will be evaluated. This process is being instituted to facilitate validation of data to the extent that such data may be used to support future licensing efforts associated with advanced reactor designs. The initial data to be evaluated under this program were generated during the US Integral Fast Reactor program between 1984-1994, where the data include, but are not limited to, research and development data and associated documents, test plans and associated protocols, operations and test data, technical reports, and information associated with past United States Nuclear Regulatory Commission reviews of SFR designs. It is recognized that managing the data generated by large research and development projects presents a significant challenge for retaining data integrity and availability. American Society of Mechanical Engineers Standard NQA-1 (NQA-1) 2008/2009a provides appropriate requirements for this plan.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quality Assurance Program Plan for SFR Metallic Fuel Data Qualification

This document contains an evaluation of the applicability of the current Quality Assurance Standards from the American Society of Mechanical Engineers Standard NQA-1 (NQA-1) criteria and identifies and describes the quality assurance process(es) by which attributes of historical, analytical, and other data associated with sodium-cooled fast reactor [SFR] metallic fuel will be evaluated. This process is being instituted to facilitate validation of data to the extent that such data may be used to support future licensing efforts associated with advanced reactor designs. The initial data to be evaluated under this program were generated during the US Integral Fast Reactor program between 1984-1994, where the data include, but are not limited to, research and development data and associated documents, test plans and associated protocols, operations and test data, technical reports, and information associated with past United States Nuclear Regulatory Commission reviews of SFR designs. It is recognized that managing the data generated by large research and development projects presents a significant challenge for retaining data integrity and availability. American Society of Mechanical Engineers Standard NQA-1 (NQA-1) 2008/2009a provides appropriate requirements for this plan.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CODE-TO-CODE BENCHMARK STUDY FOR THERMAL STRESS MODELING AND PRELIMINARY ANALYSIS OF THE HIGH-TEMPERATURE SINGLE HEAT PIPE EXPERIMENT

Microreactors are very small nuclear reactors with typical thermal-energy output of up to 20 MWth. The microreactor concept is gaining more and more attention for safe, robust, and reliable supply of electricity for remote locations and to meet industrial process heat needs. Heat-pipe-cooled microreactor is one of the microreactors being investigated at Idaho National Laboratory. In the heat-pipe-cooled microreactor, heat pipes remove heat from the reactor core as a passive heat-transfer device, so the fluid circulation is not required for cooling, which can substantially simplify the overall reactor design. However, given the extremely high temperatures in the core region and potentially large temperature gradients across the structure materials, thermal stresses need to be well-analyzed to ensure structural integrity during normal operations and accident scenarios for the heat-pipe-cooled microreactor designs. This paper discusses finite element method-based thermal-stress analysis for the high-temperature single heat-pipe test article in the Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory, using two commercial software packages, Abaqus and STAR-CCM+. A code-to-code benchmark study was performed to crosscheck the model setup and capability of each code and to gain insights into the potential thermal stress concerns from the current experimental setup. It is observed the significant thermal stresses happen at the locations where the largest temperature gradients appeared between heat pipe and electric heater. The temperature fields have good agreements between Abaqus and STAR-CCM+, while the induced thermal stresses show modest deviations probably due to differences of meshing engines used in these two codes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental Investigation of the Effect of Atomizing Electrospray Nozzles on the Cooling and Reduced Humidification of Air

Separating sensible and latent cooling have shown the potential to reduce energy consumption in A/C systems for building HVAC applications. Several technologies exist based on vapor-compression refrigeration, enthalpy wheels, chemical adsorption and absorption materials, and mechanical cooling. However, their thermodynamics limits and high energy consumption hinder their deployment in hot and humid climatic regions. This paper focuses on separating sensible and latent cooling by using a new thermodynamics process and in-kind (i.e., non-vapor compression-based) technology. Highly electrically charged water droplets were sprayed in the airflow. These droplets attracted water vapor molecules to their surfaces and promoted condensation. The phenomenon was the result of simultaneous dielectrophoresis and electro-diffusion interactions. Studies in the literature have shown that using multiple capillary electrodes reduced air moisture by up to 5% when using nanometer-size droplets in the spray. Unfortunately, these studies were limited to low airflow rates, and the objective of this paper was to investigate how to scale up this in-kind approach to airflows typical of buildings. In the present paper, droplets of micrometer size were utilized to control the humidity for a 5-cfm flow rate. While this airflow was still low for building applications, it was 100 times fold the airflows in the literature studies. The air was tested at 20°C and at 50 and 80% relative humidity. A two-fluid atomizing nozzle produced the droplets in the spray, and high DC electric potential, up to 25 kV, was used to charge the fine droplets electrically. The air atomizing nozzle with high voltage potential resembled an evaporative cooler process. However, a measurable reduction of the absolute humidity of up to 2% was observed compared to the case of the nozzle with no high voltage potential. The entire device had one small nozzle selected from off-the-shelf components and had less than a 9 cm2 footprint area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mobile Sorption-based Thermal Battery for Harvesting Low-Temperature Geothermal Energy

Around 20% of the total primary energy in the United States is consumed for thermal demands of buildings such as space cooling, dehumidification, and space heating (EIA 2018). Low-temperature geothermal energy is abundant and can effectively satisfy buildings’ thermal demands. However, low-temperature geothermal energy is underutilized because the energy density of geothermal fluid is too low to justify the costs associated with transporting it between existing geothermal resources and buildings. The mobile sorption-based thermal battery (MSTB) system has been developed using three-phase (i.e., vapor–liquid, solution–solid, crystal) sorption technology to harvest low-temperature heat and store it with a much higher energy density than the geothermal fluid. The energy density of salt crystals is over six times higher than geothermal fluid, which makes long-distance transportation of salt crystals economically feasible. Salt crystals can be used to dehumidify air or provide space cooling in buildings, which alleviates peak demand on the electricity grid by offsetting electricity use for these end uses. This helps improve the grid’s stability and resilience. High-energy storage density, fast crystallization, and dissolution of salt crystals are all critical to the viability and performance of the MSTB system. Therefore, the design and operation of MSTB systems need to ensure effective generation and dissolution of salt crystals inside the MSTB. To achieve this target, this seedling project developed an experimental apparatus for characterizing the crystallization and dissolution processes. The energy density and potential latent cooling capacity of the MSTB are also evaluated based on lab test results. The crystallization results showed that the generated lithium chloride hydrate crystals are fluffy, the crystallization process lasts about 50 min, and the maximum crystal fraction (i.e., the ratio of crystal mass to the mass in the MSTB) can be up to 51.1% of the total mass in the MSTB at a solution flow rate of 1.58 g/s. The dissolution results show that the salt crystals in the MSTB can be fully dissolved within 15–28 min, based on different test conditions. Reducing solution flow rate and cooling water temperature can achieve increased energy storage density and crystal fraction. While the increase in the discharge rate (i.e., latent cooling capacity for dehumidifying air) is achieved by increasing flow rate and temperature of inlet diluted solution, as well as by using a pump for internal solution circulation, the discharge rate increases by 38%, from 0.95 kW to 1.31 kW. Compared with increasing the inlet solution flow rate, power consumption of salt solution transportation can be reduced by using a pump for internal solution circulation. The crystallization test results also showed that the maximum energy storage density is 981.8 kJ/kg, and the maximum discharge rate of the dissolution tests is ≤1.79 kW. Both are above the target values of 900 kJ/kg and 1.75 kW) for this project. The work reported here proves the feasibility and advancement of the MSTB system, which is helpful to the further study and improvement of the MSTB system.

15 GEOTHERMAL ENERGY↗

ILAW Container Cost Reduction and Optimization Study

This study, performed on behalf of Washington River Protection Solutions (WRPS), examines the potential for making cost savings for the Immobilized Low Active Waste (ILAW) containers over the mission life of the Waste Treatment and Immobilization Plant (WTP). it builds on earlier study assessments 24590-LAW-RPT-M-01-001 Rev 0 ILAW Product Container Specifications Optimization Study and DOE/ORP-2013-02 Rev 0 Decision Analysis of Low-Active Waste Container Finishing Handling System Alternatives. The WTP design and installed equipment has evolved over an extended period ~20 years. Consequently, some of the existing requirements relating the ILAW containers may no longer be applicable under current mission plans where the glass filled containers are placed into the Integrated Disposal Facility (IDF) rather than stacked in an engineered purpose-built ventilated store as originally envisioned. The study team reviewed available WTP project reference documents to establish the functions the container must perform and assign requirements against each of these functions. With the assumptions that some of the existing WTP contract restrictions would not necessarily apply to the subsequent facility operations contract the container requirements were reviewed to identify those which were ‘hard constraints‘, imposed by regulatory requirements. Initially each of these hard constraints were reviewed, evaluated and documented to see if they precluded the use of an alternate less expensive material of construction, carbon steel, to the existing 304 L stainless steel in the current container specification. That review did not generate any fatal flaws for a change in material of construction to carbon steel allowing the study team to examine the impacts of material cost savings, potential changes to the design and requirements and impacts on interfaces of the containers with the existing WTP process equipment from container receipt, transfers, glass filling, cooling and export. In addition, a change in container target fill level was evaluated and qualitative, and quantitative where feasible, impacts to the container fabrication process assessed. Lastly, additional follow on development or testing activities to support the use of carbon steel were assessed and a recommended path forward with a ROM cost and timescale developed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design optimization of integrated cooling inserts in modular Fischer-Tropsch reactors

Sustainable production of liquid fuels and feedstocks from atmospheric CO 2 through carbon recycling technologies is necessary to broaden decarbonization efforts and further reduce global emissions. Fischer–Tropsch (FT) reactors can address this challenge by providing storable, high-value liquid hydrocarbon fuels and feedstocks from syngas generated through reductive CO 2 utilization. FT technology, however, is most cost effective at large-scale, fixed-site plants and does not effectively address the smaller, globally distributed CO 2 point sources. Alternatively, smaller, modular reactors can be composed together to the specific scale of the emission source, yielding a flexible solution that enables more widespread deployment. In these modular reactors, thermal management using a finned cooling insert embedded within the catalyst matrix is critical to maintaining the performance and viability. Thus, in this work, topology optimization is used to determine the cooling insert geometry that maximizes reactor productivity while preventing auto-thermal runaway. Optimal designs are generated for varying number of constituent fins and over a range of maximum operating temperatures. Constraints including minimum feature length-scales and prescribed cooling insert material are imposed on the designs to enhance manufacturability. The impact of design features such as insert tapering and increased length scale hierarchy is automatically revealed by the systematic design framework employed. Here, this approach thus generates novel optimal geometries while automating, accelerating, and enhancing the design process compared to traditional heuristic approaches for cooling insert design in modular FT reactors.

30 DIRECT ENERGY CONVERSION↗

Field Validation of Electrochemical Water Filtration System on an Open Loop Cooling Tower at Nissan Manufacturing Plant in Canton, Mississippi

The U.S. Department of Energy Industrial Efficiency and Decarbonization Office’s Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized technologies in the industrial sector to help inform decisions towards accelerating commercialization and deployment. This ITV demonstration investigated the performance of an early-commercial electrochemical water treatment technology on a cooling tower at an automotive plant. Cooling towers are vital equipment for dissipating heat from industrial processes, but they face challenges related to scaling, corrosion, and the growth of biological contaminants. Effective cooling tower water treatment is therefore essential in reducing these contaminants and other total suspended solids (TSS) and total dissolved solids (TDS). Various treatment systems, such as sand-based filters, centrifugal separators, and disc filters are available, each having its advantages and drawbacks. ElectroCell Systems, a filtration technology provider, offers an electrochemistry-based water treatment system that is skid-mounted and can be configured as a side-stream filtration system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of plug flow and multi-node stratified tank modeling approaches regarding computational efficiency and accuracy

Residential water heaters contain water stratified by temperature-driven density differences. This implies that a water tank can reach a state in which the top and bottom sections have different temperatures, unless mixing happens. A high degree of thermal stratification can improve the efficiency of some water heaters, by saving the amount of energy required for the heat-up process. Studies of stratification became popular in the 1970s and it remains an active research topic today. The research has led to the development of different models and techniques to better predict and define a stratified tanks behavior. By comparing these models and techniques used previously to describe thermal stratification, the phenomenon could be better understood, exploited, and used to increase efficiency and thermal energy capacity in modern water tanks. From the existing models, we found the one-dimensional standard plug-flow and a multi node model to be appropriate for analyzing the processes of the heat up and cool-down in a water tank. These two models are based on energy balances. This work involved comparing the accuracy and computational effort needed to implement these models. To assess accuracy, we compared both types of existing models to experimental data (also collected in this work) which included a heat up process using an external heat pump. This external process included a layering process that has an eddy diffusivity at five times the rate of thermal diffusion. For this project, we implemented the models in MATLAB, the multi-paradigm numerical computing environment. We quantified model accuracy using the root mean squared error between modeled data and experimental data for six measured tank temperatures. Comparing the accuracy and the computational time taken to run the simulation provides a method to contrast the performance of each model and a way to rate it. The multi node model was run using from 6 to 96 spatial nodes; the plug flow model was run using 1 to 0.001 º C temperature bin sizes. Additionally, timesteps were varied from 4 to 236 s. The results quantify the tradeoff between accuracy and computational time, providing guidance for simulations to intelligently select the best model type and simulation parameters. This research can be used to validate the pre-existing models and possibly improve the modern water tank.

Bulnes, Fernando Karg↗

Performance of Public Film Cooling Geometries Produced Through Additive Manufacturing

Abstract Film cooling is an essential cooling technology to allow modern gas turbines to operate at high temperatures. For years, researchers in this community have worked to improve the effectiveness of film cooling configurations by maximizing the coolant coverage and minimizing the heat flux from the hot gas into the part. Working toward this goal has generated many promising film cooling concepts with unique shapes and configurations. However, until recently, many of these designs were challenging to manufacture in actual turbine hardware due to limitations with legacy manufacturing methods. Now, with the advances in additive manufacturing, it is possible to create turbine parts using high-temperature nickel alloys that feature detailed and unique geometry features. Armed with this new manufacturing power, this study aims to build and test the promising designs from the public literature that were previously difficult or impossible to implement. In this study, different cooling hole designs were manufactured in test coupons using a laser powder bed fusion process. Each nickel alloy coupon featured a single row of engine scale cooling holes, fed by a microchannel. To evaluate performance, the overall cooling effectiveness of each coupon was measured using a matched Biot test at engine relevant conditions. The results showed that certain hole shapes are better suited for additive manufacturing than others and that the manufacturing process can cause significant deviations from the performance reported in the literature.

Engineering↗

Impact of Additive Manufacturing on Internal Cooling Channels With Varying Diameters and Build Directions

Abstract The use of additive manufacturing (AM) processes, such as direct metal laser sintering, provides the design freedom required to incorporate complex cooling schemes in gas turbine components. Additively manufactured turbine components have a range of cooling feature sizes and, because of the inherent three-dimensionality, a wide range of build angles. Previous studies have shown that AM built directions influence internal channel surface roughness that, in turn, augment heat transfer and pressure loss. This study investigates the impact of AM on channel feature size and builds direction relative to tolerance, surface roughness, pressure losses, and convective cooling. Multiple AM coupons were built from Inconel 718 consisting of channels with different diameters and a variety of build directions. An experimental rig was used to measure pressure drop to calculate friction factor and was used to impose a constant surface temperature boundary condition to collect Nusselt number over a range of Reynolds numbers. Significant variations in surface roughness and geometric deviations from the design intent were observed for distinct build directions and channel sizes. These differences led to notable impacts in friction factor and Nusselt number augmentations, which were a strong function of build angle.

Engineering↗

Modeling of a Four-Stage Linear Ionization Cooling Channel for a Muon Collider in g4Beamline

A previous study of an eight-stage rectilinear ionization cooling channel in the ICOOL software demonstrated a five-order-of-magnitude reduction in a muon beam’s 6D emittance. In this study, we look to compare the ways ICOOL and Muons, Inc.’s g4Beamline software model ionization cooling by comparing their modeling of the first four stages of this optimized cooling channel constructed in ICOOL. We begin by identifying the parameters used to construct the optimized ionization cooling channel in ICOOL. We then reconstruct this beam in g4Beamline with identical parameter specifications and simulate the cooling of an identical input beam. Finally, we compare the two simulations based on their beam transmission, longitudinal emittance, and transverse emittance along the channel length. Through this process, we demonstrate that G4Beamline accurately reproduces transverse cooling results but predicts systematically different longitudinal emittance evolution while maintaining similar overall cooling performance, reproducing a 97.9% reduction in 6D emittance over four stages.

Keeler, Dominic [Purdue U., West Lafayette] (ORCID↗

Modeling of a Four-Stage Linear Ionization Cooling Channel for a Muon Collider in G4Beamline

A previous study of an eight-stage rectilinear ionization cooling channel in the ICOOL software demonstrated a five-order-of-magnitude reduction in a muon beam’s 6D emittance. In this study, we look to compare the ways ICOOL and Muons, Inc.’s g4Beamline software model ionization cooling by comparing their modeling of the first four stages to this optimized cooling channel constructed in ICOOL. We begin by identifying the parameters used to construct the optimized ionization cooling channel in ICOOL. We then reconstruct this beam in g4Beamline with identical parameter specifications and simulate the cooling of an identical input beam. Finally, we compare the two simulations based on their beam transmission, longitudinal emittance, and transverse emittance along the channel length. Through this process, we demonstrate that G4Beamline accurately reproduces transverse cooling results but predicts systematically different longitudinal emittance evolution while maintaining similar overall cooling performance, reproducing a 97.9% reduction in 6D emittance over four stages.

Keeler, Dominic [Purdue U., West Lafayette] (ORCID↗

Assessment of Molybdate Based Corrosion Inhibitor for use at the Savannah River Tank Farm Cooling Water System

The Savannah River Site (SRS) has relied on 51 underground storage tanks, many dating back to the 1950s, to store radioactive liquid waste generated from nuclear processing and radionuclide production. These tanks use carbon steel cooling coils, cooled by soft, acidic water, to dissipate the decayed heat produced by radioactive waste. For decades, following historical industry practices, chromate has been added to the cooling water (~450 ppm at pH 9-11) to effectively inhibit corrosion, ensuring cooling coil longevity. Inspections of failed coils reveal that chromate-treated surfaces are generally well-preserved.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗