Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “potential energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Polaron catastrophe within quantum acoustics

The quantum acoustic framework has recently emerged as a nonperturbative, coherent approach to electron–lattice interactions, uncovering rich physics often obscured by perturbative methods with incoherent scattering events. Here, we model the strongly coupled dynamics of electrons and acoustic lattice vibrations within this framework, representing lattice vibrations as coherent states and electrons as quantum wave packets, in a manner distinctively different from tight-binding or discrete hopping-based approaches. We derive and numerically implement electron backaction on the lattice, providing both visual and quantitative insights into electron wave packet evolution and the formation of acoustic polarons. We investigate polaron binding energies across varying material parameters and compute key observables—including mean square displacement, kinetic energy, potential energy, and vibrational energy—over time. Our findings reveal the conditions that favor polaron formation, which is enhanced by low temperatures, high deformation potential constants, slow sound velocities, and high effective masses. Additionally, we explore the impact of external electric and magnetic fields, showing that while polaron formation remains robust under moderate fields, it is weakly suppressed at higher field strengths. These results deepen our understanding of polaron dynamics and pave the way for future studies into nontrivial transport behavior in quantum materials.

Science & Technology - Other Topics↗

Two-dimensional quantum gas with real time control of complete Hamiltonian (Final Report)

We developed a novel quantum platform with the complete capability to control individual atoms and their mutual interactions in real time. Ultracold atoms are employed since they have the lowest temperature and decoherence. This system is the ultimate dream of quantum physicists where the Hamiltonian of every single atom, including its kinetic energy, potential energy, and interactions, can be independently programmed in real time. We also initiated a new theoretical collaboration to explore its full potential.

74 ATOMIC AND MOLECULAR PHYSICS↗

Rigid-flexible coupling multi-body dynamics modeling of a semi-submersible floating offshore wind turbine

A 14-degree-of-freedom (14-DOF) flexible multibody dynamics model is developed and verified for a semi-submersible floating offshore wind turbine (FOWT). The model considers the coupled dynamics of the platform, tower, nacelle, blades, and mooring subjected to external wind and wave loads. The platform is simplified as a rigid body connected to the seabed by the mooring system. The tower and blade are modeled as flexible cantilever beams. The energy method is used to derive the governing equations of motion, where the kinetic energy, potential energy, and work done by external wind-wave forces are all deduced in a global coordinate system. The 5-MW baseline semi-submersible FOWT is used to verify the derived model against the results simulated from FAST developed by the US National Renewable Energy Laboratory (NREL) at two scenarios: free decay state and different wind-wave load cases. Results show that the established FOWT model can well reflect the vibration characteristics of FAST model. The application of the model to the control of platform pitch with a tuned mass damper is studied. Furthermore, the simplified model could provide a low-order method for the structural dynamics analysis and advanced vibration control design for the multi-body components of the semi-submersible FOWT in the future.

17 WIND ENERGY↗

Energy Index For Aircraft Maneuvers

Method and system for analyzing, separately or in combination, kinetic energy and potential energy and/or their time derivatives, measured or estimated or computed, for an aircraft in approach phase or in takeoff phase, to determine if the aircraft is or will be put in an anomalous configuration in order to join a stable approach path or takeoff path. A 3 reference value of kinetic energy andor potential energy (or time derivatives thereof) is provided, and a comparison index .for the estimated energy and reference energy is computed and compared with a normal range of index values for a corresponding aircraft maneuver. If the computed energy index lies outside the normal index range, this phase of the aircraft is identified as anomalous, non-normal or potentially unstable.

Chidester, Thomas R.↗

Momentum and Heat Flux Measurements in the Exhaust of VASIMR Using Helium Propellant

Electromagnetic thrusters typically use electric and magnetic fields to accelerate and exhaust plasma through interactions with the charged particles in the plasma. The energy required to create the plasma, i.e. ionization energy, is potential energy between the electron and ion. This potential energy is typically lost since it is not recovered as the plasma is exhausted and is known as frozen flow loss. If the frozen flow energy is a small fraction of the total plasma energy, this frozen flow loss may be negligible. However, if the frozen flow energy is a major fraction of the total plasma energy, this loss can severely reduce the energy efficiency of the thruster. Recovery and utilization of this frozen flow energy can improve the energy efficiency of a thruster during low specific impulse operating regimes when the ionization energy is a large fraction of the total plasma energy. This paper quantifies the recovery of the frozen flow energy, i.e. recombination energy, via the process of surface recombination for helium. To accomplish this task the momentum flux and heat flux of the plasma flow were measured and compared to calculated values from electrostatic probe data. This information was used to deduce the contribution of recombination energy to the total heat flux on a flat plate as well as to characterize the plasma conditions. Helium propellant was investigated initially due to its high ionization potential and hence available recombination energy.

Chavers, D. Gregory↗

Potential Heating Energy and Cost Savings of Dual Fuel Heat Pump Controls as a Residential Building Equipment Retrofit in the U.S.

This study investigated the energy and cost savings potential by modeling a dual fuel heat pump system with its control for a residential building in (5A) cold climate in U.S. The simulation analysis showed that the application of the DFHP system and its control to the target building can save the heating energy by 42% over a gas furnace system (baseline system). Although the HP-only system can save more heating energy (i.e., 53%) over the baseline system than DFHP system does, the DFHP with its control demonstrated the higher cost savings when a time of use electricity rate was considered.

Yoon, Yeobeom↗

Nationwide HVAC Energy-Saving Potential Quantification for Office Buildings with Occupant-Centric Controls in Various Climates

The occupant-centric control (OCC) is receiving an increasing attention due to its ability to reduce building heating ventilation and air-conditioning (HVAC) system energy consumptions while not affecting the occupant thermal comfort. This paper aims to investigate and quantify the nationwide energy-saving potential of implementing the occupant-centric HVAC controls in typical office buildings using a whole building simulation software EnergyPlus. First, the medium office and large office from the Department of Energy (DOE) Commercial Prototype Building Models (CBPM) were enhanced to have detailed layouts and dynamic occupancy schedules. Then, a comprehensive simulation plan was created by incorporating the multiple zone-level and system-level occupant-centric building HVAC controls recommended by the updated ASHRAE Standard 90.1 – 2019 and ASHRAE Guideline 36 – 2018. Three control scenarios with different occupancy sensing methods were identified in this simulation plan. A nation-wide parametric analysis which includes two building types, three occupancy sensing scenarios, two building code versions, and 16 U.S. climate zones was carried out. The simulation results of the key control variables and HVAC energy consumption suggest that generally, both the occupancy presence sensor and occupant counting sensor could achieve energy savings for the office buildings in majority of the scenarios. However, compared with the occupancy presence sensor, which could support both the temperature setpoint reset and operational breathing zone airflow rate reset for the unoccupied zones, the occupant counting sensor only brings a marginal benefit. Besides, a higher HVAC energy-saving ratio could be achieved in the heating-dominated zone, since the energy reduction brought with the minimum outdoor airflow rate reset is stronger in the heating mode.

Pang, Zhihong↗

Potential Cooling Energy Savings of Economizer Control and Artificial-Neural-Network-Based Air-Handling Unit Discharge Air Temperature Control for Commercial Building

Heating, ventilation, and air-conditioning (HVAC) systems play a significant role in building energy consumption, accounting for around 50% of total energy usage. As a result, it is essential to explore ways to conserve energy and improve HVAC system efficiency. One such solution is the use of economizer controls, which can reduce cooling energy consumption by using the free-cooling effect. However, there are various types of economizer controls available, and their effectiveness may vary depending on the specific climate conditions. To investigate the cooling energy-saving potential of economizer controls, this study employs a dry-bulb temperature-based economizer control approach. The dry-bulb temperature-based control strategy uses the outdoor air temperature as an indicator of whether free cooling can be used instead of mechanical cooling. This study also introduces an artificial neural network (ANN) prediction model to optimize the control of the HVAC system, which can lead to additional cooling energy savings. To develop the ANN prediction model, the EnergyPlus program is used for simulation modeling, and the Python programming language is employed for model development. The results show that implementing a temperature-based economizer control strategy can lead to a reduction of 7.6% in annual cooling energy consumption. Moreover, by employing an ANN-based optimal control of discharge air temperature in air-handling units, an additional 22.1% of cooling energy savings can be achieved. In conclusion, the findings of this study demonstrate that the implementation of economizer controls, especially the dry-bulb temperature-based approach, can be an effective strategy for reducing cooling energy consumption in HVAC systems. Additionally, using ANN prediction models to optimize HVAC system controls can further increase energy savings, resulting in improved energy efficiency and reduced operating costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A framework for estimating the energy-saving potential of occupant behaviour improvement

Energy-related occupant behaviour in buildings has demonstrated considerable energy-saving potential. However, the current modelling method of occupant behaviour does not give sufficient considerations on the implementation difficulty of behaviour and provide a holistic map from survey data to various behaviour models. This article proposes a holistic survey-and-simulation-based framework for estimating the energy-saving potential of occupant behaviour improvement. In the framework, seven typical categories of occupant behaviour models are identified based on the survey results. According to the implementation difficulty, the models are integrated into four behaviour styles (baseline, wasteful, moderate and austere) to represent different levels of energy-saving consciousness of occupants. Based on a case study with a nationwide survey in Singapore, there are remarkable energy savings potential if occupant behaviour is improved; the building energy consumption can be reduced by up to 9.5% with the moderate behaviour improvement, and up to 21.0% with the aggressive behaviour improvement. The simulation results accord well with the measured results within a reasonable range of deviation. The framework can be applied to estimate the energy-saving potential of occupant behaviour improvement in a building with affordable cost, and the findings can inform a behaviour improvement programme with effective and efficient measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Theory and Implementation of the Spectacular Nonlinear Viscoelastic Constitutive Model

This report is a comprehensive guide to the nonlinear viscoelastic Spectacular model, which is an isotropic, thermo-rheologically simple constitutive model for glass-forming materials, such as amorphous polymers. Spectacular is intermediate in complexity to the previous PEC and SPEC models (Potential Energy Clock and Simplified Potential Energy Clock models, respectively). The model form consists of two parts: a Helmholtz free energy functional and a nonlinear material clock that controls the rate of viscoelastic relaxation. The Helmholtz free energy is derived from a series expansion about a reference state. Expressions for the stress and entropy functionals are derived from the Helmholtz free energy following the Rational Mechanics approach. The material clock depends on a simplified expression for the potential energy, which itself is a functional of the temperature and strain histories. This report describes the thermo-mechanical theory of Spectacular, the numerical methods for time-integrating the model, model verification for its implementation in LAMÉ, a user guide for its implementation in LAMÉ, and ideas for future work. A number of appendices provide supplementary mathematical details and a description of the procedure used to derive the simplified potential energy from the full expression for the potential energy. The goal of this report is create a convenient point-of-entry for engineers who wish to learn more about Spectacular, but also to serve as a reference manual for advanced users of the model.

36 MATERIALS SCIENCE↗

Learning local and semi-local density functionals from exact exchange-correlation potentials and energies

Finding accurate exchange-correlation (XC) functionals remains the defining challenge in density functional theory (DFT). Despite 40 years of active development, attaining general purpose chemical accuracy is still elusive with existing functionals. We present a data-driven pathway to learn the XC functional by using the exact density, XC energy, and XC potential. While the exact densities are obtained from accurate configuration interaction (CI), the exact XC energies and XC potentials are obtained via inverse DFT calculations on the CI densities. We demonstrate how simple neural network (NN)–based local density approximation (LDA) and generalized gradient approximation (GGA), trained on just five atoms and two molecules, provide remarkable improvement in total energies and densities. Particularly, the NN-based GGA functional attains similar accuracy as the higher rung SCAN meta-GGA on various thermochemistry datasets. These results underscore the promise of using the XC potential in modeling XC functionals and can pave the way for systematic learning of increasingly accurate XC functionals.

Science & Technology - Other Topics↗

Direct coherent switching with decay of mixing for intersystem crossing dynamics of thioformaldehyde: The effect of decoherence

We evaluate the effect of electronic decoherence on intersystem crossing in the photodynamics of thioformaldehyde. First, we show that the state-averaged complete-active-space self-consistent field electronic structure calculations with a properly chosen active space of 12 active electrons in 10 active orbitals can predict the potential energy surfaces and the singlet–triplet spin–orbit couplings quite well for CH 2 S, and we use this method for direct dynamics by coherent switching with decay of mixing (CSDM). We obtain similar dynamical results with CSDM or by adding energy-based decoherence to trajectory surface hopping, with the population of triplet states tending to a small steady-state value over 500 fs. Without decoherence, the state populations calculated by the conventional trajectory surface hopping method or the semiclassical Ehrenfest method gradually increase. This difference shows that decoherence changes the nature of the results not just quantitatively but qualitatively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Overall chilled water system energy consumption modeling and optimization

The emergence of increasingly affordable variable-speed drive technology has changed the approach used to control chilled water systems equipped with these drives. The purpose of this research was to develop an integrated chilled water modeling technique that can determine the optimal system setpoints and estimate the energy saving potential of chiller system. The chiller system equipped with Variable Frequency Drives (VFDs) on cooling tower fans and condenser water pumps. To accomplish the objective, physical component models of the centrifugal chiller, cooling tower and condenser water pump were established with the goal of incorporating the system’s condenser water flow rate and cooling tower fan speeds as optimization variables. Furthermore, a cooling load prediction algorithm was developed using a multiple non-linear regression model to approximate the building’s cooling load subject to a range of environmental conditions. The inputs and outputs of the individual component models were linked to estimate how adjusting the cooling tower fan and condenser water pump speed would influence the system’s comprehensive performance. Here, the overall system model was then optimized using a generalized reduced gradient optimization algorithm to determine the potential energy savings through speed control with VFDs and to ascertain a control logic strategy for the building automation system to operate the heating and cooling system. A case-study was performed on a single chiller system at a museum and the model was calibrated according to logged data collected over four months. Results showed that for the system analyzed, the energy saving of optimizing the cooling tower fan system was found to be 12–15%, while the energy saving potential of optimizing the condenser water pump with the cooling tower fan was negligible. Additionally, comparing different cooling tower fan control strategies showed that a wet-bulb approach-based cooling tower control strategy was shown to have the highest correlation to the optimized fan speed with an R 2 of 0.924.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unmasking Static Correlation Error in Hybrid Kohn–Sham Density Functional Theory

To uncover the way Hartree–Fock exchange brings static correlation error into hybrid Kohn–Sham density functional theory, we compare the potential energy curves of four diatomic molecules, namely, H 2 , F 2 , HF, and NaF, using both restricted and unrestricted Kohn–Sham theory. Here, we find that increasing the percentage of Hartree–Fock exchange significantly increases the static correlation error because Hartree–Fock exchange replaces the ability of local exchange in density functionals to account for the localization effects associated with static correlation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simultaneous velocity and density measurements of fully developed Rayleigh-Taylor mixing

Here, the dynamics of molecular mixing and the energy transfer process in the Rayleigh-Taylor instability (RTI) are studied through the collection of simultaneous density-velocity measurements. These experiments provide simultaneous density-velocity field measurements, in contrast to previous point measurements. Statistically stationary experiments are performed in a “convective-type” gas tunnel facility, with density contrast achieved through the injection of helium into the bottom stream. Three experiments at Atwood number ≈ 0.1 are captured at three outer scale Reynolds numbers Re = 520, 2260, and 4050. Particle image velocimetry and laser induced fluorescence are employed simultaneously. Statistics of the density and velocity show self-similar collapse of RTI profiles at large Reynolds number Re >2000. Flat velocity profiles indicate homogeneous turbulence characteristics in the core of the mixing region. Significant anisotropy develops in the flow, with horizontal velocity fluctuations being only 60% of the vertical velocity fluctuations. The turbulent mass flux is found to be asymmetric about the centerline, with increased peak towards the spike. Measurements of the molecular mixing show that mixing is maximized at the core of the flow and increases with increased Reynolds number. The transport equation of density-specific-volume correlation b shows that it is mostly produced in the core of the mixing region, and that the spatial evolution of its profile is the result of transport by bulk motion of the bubble and spike. Energy transfer from gravitational potential energy to turbulent kinetic energy and viscous dissipation is observed to occur in the experiment with a ratio of dissipated energy to potential energy released of 38%. The analysis of the turbulent kinetic energy transport equation budget reveals that production is the primary mechanism towards the growth of turbulent kinetic energy in the core of the flow, and is asymmetrically slightly skewed towards the spike. However, it is through the transport that the strong advection at the edges of the mixing region is maintained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic Energy Accuracy of Neural Network Potentials: Harnessing Pretraining and Transfer Learning

Machine learning-based interatomic potentials (MLIPs) have transformed the prediction of potential energy surfaces (PESs), achieving accuracy comparable to ab initio calculations. However, atomic energy predictions, often assumed to lack physical meaning, remain underexplored. In this study, we demonstrate that inaccuracies in atomic energy predictions reduce the robustness and transferability of Neural Network Potentials (NNPs) and atomic energy error can be masked in total energy predictions due to error cancellation. Here, we validate this finding using challenging configurations involving deformation and failure under tensile loading. By pretraining atomic energy predictions using empirical potentials and applying transfer learning with density functional theory (DFT) data, we achieve notable improvements in the accuracy of total energy, forces, and stress predictions. Furthermore, this approach enhances the robustness and transferability of NNPs, emphasizing the importance of atomic energy predictions in developing high-quality and reliable MLIPs.

Active Learning↗

A numerical simulation of seasonal stratospheric climate. II - Energetics

The paper analyzes the energetics involved in the two numerical experiments described in Part I, concerning a longwave radiative transfer model and a simple Newtonian cooling (or heating) model. A three-dimensional quasi-geostrophic model is developed and used over the entire annual cycle to test the climatic responses of the stratospheric circulation to the cited two different longwave radiative heating models. It is shown that the eddy energy parameters (eddy kinetic energy, eddy available potential energy, generation of the latter, and vertical propagation of eddy geopotential energy) undergo annual variations with maximum values in winter and minimum values in summer. The zonal energy parameters exhibit semiannual variations with major maximum values in winter, minor maxima in summer and minima in spring and fall. Analysis of the energy cycle reveals that the vertical propagation of eddy geopotential energy and the generation of eddy available potential energy are the energy sources for energetics in the upper stratosphere. Ways in which the longwave radiative processes may affect the stratospheric energetics are identified.

Chen, T.-C.↗

Energy-saving potential evaluation for primary schools with occupant-centric controls

Recent studies demonstrated that there is significant energy-saving potential for primary schools, which heating, ventilation, and air-conditioning (HVAC) systems with occupant-centric control (OCC) is an excellent candidate to save energy. However, such an energy impact has yet to be evaluated for different climate zones as well as different energy code versions, but is critical for technology transfer and deployment. Therefore, this paper conducts comprehensive evaluation on the energy-saving potentials for the primary schools with two advanced OCC strategies: presence-based and counting-based. In this work, ninety-six building energy models with stochastic behavior of occupants are developed and simulated, which consist of two building energy code versions, 16 climate zones, and baseline case (without OCC) and two advanced cases (with OCC). To evaluate the energy saving potentials for OCC, primary schools in the U.S. are used as an example. The results show that there is significant energy-saving potential for primary schools by considering OCC strategies, especially the counting-based case. The energy-saving potential is up to 10.2% for presence-based OCC and 12.41% for counting-based OCC. Furthermore, both climate and code version have a significant impact on energy savings from OCC strategies. The energy-saving potentials vary from 1.79% to 12.41% for different climates and code versions. This evaluation can also contribute to quantify the nationwide energy saving potential for other countries.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗