An RF dosimeter for independent SAR measurement in MRI scanners

Purpose: The monitoring and management of radio frequency (RF) exposure is critical for ensuring magnetic resonance imaging (MRI) safety. Commercial MRI scanners can overestimate specific absorption rates (SAR) and improperly restrict clinical MRI scans or the application of new MRI sequences, while underestimation of SAR can lead to tissue heating and thermal injury. Accurate scanner-independent RF dosimetry is essential for measuring actual exposure when SAR is critical for ensuring regulatory compliance and MRI safety, for establishing RF exposure while evaluating interventional leads and devices, and for routine MRI quality assessment by medical physicists. However, at present there are no scanner-independent SAR dosimeters. Methods: An SAR dosimeter with an RF transducer comprises two orthogonal, rectangular copper loops and a spherical MRI phantom. The transducer is placed in the magnet bore and calibrated to approximate the resistive loading of the scanner's whole-body birdcage RF coil for human subjects in Philips, GE and Siemens 3 tesla (3T) MRI scanners. The transducer loop reactances are adjusted to minimize interference with the transmit RF field (B{sub 1}) at the MRI frequency. Power from the RF transducer is sampled with a high dynamic range power monitor and recorded on a computer. The deposited power is calibrated and tested on eight different MRI scanners. Whole-body absorbed power vs weight and body mass index (BMI) is measured directly on 26 subjects. Results: A single linear calibration curve sufficed for RF dosimetry at 127.8 MHz on three different Philips and three GE 3T MRI scanners. An RF dosimeter operating at 123.2 MHz on two Siemens 3T scanners required a separate transducer and a slightly different calibration curve. Measurement accuracy was ∼3%. With the torso landmarked at the xiphoid, human adult whole‑body absorbed power varied approximately linearly with patient weight and BMI. This indicates that whole-body torso SAR is on average independent of the imaging subject, albeit with fluctuations. Conclusions: Our 3T RF dosimeter and transducers accurately measure RF exposure in body-equivalent loads and provide scanner-independent assessments of whole-body RF power deposition for establishing safety compliance useful for MRI sequence and device testing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Medical imaging using ionizing radiation: Optimization of dose and image quality in fluoroscopy

The 2012 Summer School of the American Association of Physicists in Medicine (AAPM) focused on optimization of the use of ionizing radiation in medical imaging. Day 2 of the Summer School was devoted to fluoroscopy and interventional radiology and featured seven lectures. These lectures have been distilled into a single review paper covering equipment specification and siting, equipment acceptance testing and quality control, fluoroscope configuration, radiation effects, dose estimation and measurement, and principles of flat panel computed tomography. This review focuses on modern fluoroscopic equipment and is comprised in large part of information not found in textbooks on the subject. While this review does discuss technical aspects of modern fluoroscopic equipment, it focuses mainly on the clinical use and support of such equipment, from initial installation through estimation of patient dose and management of radiation effects. This review will be of interest to those learning about fluoroscopy, to those wishing to update their knowledge of modern fluoroscopic equipment, to those wishing to deepen their knowledge of particular topics, such as flat panel computed tomography, and to those who support fluoroscopic equipment in the clinic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using LiF:Mg,Cu,P TLDs to estimate the absorbed dose to water in liquid water around an {sup 192}Ir brachytherapy source

Purpose: The absorbed dose to water is the fundamental reference quantity for brachytherapy treatment planning systems and thermoluminescence dosimeters (TLDs) have been recognized as the most validated detectors for measurement of such a dosimetric descriptor. The detector response in a wide energy spectrum as that of an{sup 192}Ir brachytherapy source as well as the specific measurement medium which surrounds the TLD need to be accounted for when estimating the absorbed dose. This paper develops a methodology based on highly sensitive LiF:Mg,Cu,P TLDs to directly estimate the absorbed dose to water in liquid water around a high dose rate {sup 192}Ir brachytherapy source. Methods: Different experimental designs in liquid water and air were constructed to study the response of LiF:Mg,Cu,P TLDs when irradiated in several standard photon beams of the LNE-LNHB (French national metrology laboratory for ionizing radiation). Measurement strategies and Monte Carlo techniques were developed to calibrate the LiF:Mg,Cu,P detectors in the energy interval characteristic of that found when TLDs are immersed in water around an{sup 192}Ir source. Finally, an experimental system was designed to irradiate TLDs at different angles between 1 and 11 cm away from an {sup 192}Ir source in liquid water. Monte Carlo simulations were performed to correct measured results to provide estimates of the absorbed dose to water in water around the {sup 192}Ir source. Results: The dose response dependence of LiF:Mg,Cu,P TLDs with the linear energy transfer of secondary electrons followed the same variations as those of published results. The calibration strategy which used TLDs in air exposed to a standard N-250 ISO x-ray beam and TLDs in water irradiated with a standard{sup 137}Cs beam provided an estimated mean uncertainty of 2.8% (k = 1) in the TLD calibration coefficient for irradiations by the {sup 192}Ir source in water. The 3D TLD measurements performed in liquid water were obtained with a maximum uncertainty of 11% (k = 1) found at 1 cm from the source. Radial dose values in water were compared against published results of the American Association of Physicists in Medicine and the European Society for Radiotherapy and Oncology and no significant differences (maximum value of 3.1%) were found within uncertainties except for one position at 9 cm (5.8%). At this location the background contribution relative to the TLD signal is relatively small and an unexpected experimental fluctuation in the background estimate may have caused such a large discrepancy. Conclusions: This paper shows that reliable measurements with TLDs in complex energy spectra require a study of the detector dose response with the radiation quality and specific calibration methodologies which model accurately the experimental conditions where the detectors will be used. The authors have developed and studied a method with highly sensitive TLDs and contributed to its validation by comparison with results from the literature. This methodology can be used to provide direct estimates of the absorbed dose rate in water for irradiations with HDR{sup 192}Ir brachytherapy sources.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A modern Monte Carlo investigation of the TG-43 dosimetry parameters for an {sup 125}I seed already having AAPM consensus data

Purpose: To investigate potential causes for differences in TG-43 brachytherapy dosimetry parameters in the existent literature for the model IAI-125A{sup 125}I seed and to propose new standard dosimetry parameters. Methods: The MCNP5 code was used for Monte Carlo (MC) simulations. Sensitivity of dose distributions, and subsequently TG-43 dosimetry parameters, was explored to reproduce historical methods upon which American Association of Physicists in Medicine (AAPM) consensus data are based. Twelve simulation conditions varying{sup 125}I coating thickness, coating mass density, photon interaction cross-section library, and photon emission spectrum were examined. Results: Varying{sup 125}I coating thickness, coating mass density, photon cross-section library, and photon emission spectrum for the model IAI-125A seed changed the dose-rate constant by up to 0.9%, about 1%, about 3%, and 3%, respectively, in comparison to the proposed standard value of 0.922 cGy h{sup −1} U{sup −1}. The dose-rate constant values by Solberg et al. [“Dosimetric parameters of three new solid core {sup 125}I brachytherapy sources,” J. Appl. Clin. Med. Phys. 3, 119–134 (2002)], Meigooni et al. [“Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGE™ {sup 125}I brachytherapy source,” Med. Phys. 29, 2152–2158 (2002)], and Taylor and Rogers [“An EGSnrc Monte Carlo-calculated database of TG-43 parameters,” Med. Phys. 35, 4228–4241 (2008)] for the model IAI-125A seed and Kennedy et al. [“Experimental and Monte Carlo determination of the TG-43 dosimetric parameters for the model 9011 THINSeed™ brachytherapy source,” Med. Phys. 37, 1681–1688 (2010)] for the model 6711 seed were +4.3% (0.962 cGy h{sup −1} U{sup −1}), +6.2% (0.98 cGy h{sup −1} U{sup −1}), +0.3% (0.925 cGy h{sup −1} U{sup −1}), and −0.2% (0.921 cGy h{sup −1} U{sup −1}), respectively, in comparison to the proposed standard value. Differences in the radial dose functions between the current study and both Solberg et al. and Meigooni et al. were <10% for r ≤ 5 cm, and increased for r > 5 cm with a maximum difference of 29% at r = 9 cm. In comparison to Taylor and Rogers, these differences were lower (maximum of 2% at r = 9 cm). For the similarly designed model 6711 {sup 125}I seed, differences did not exceed 0.5% for 0.5 ≤ r ≤ 10 cm. Radial dose function values varied by 1% as coating thickness and coating density were changed. Varying the cross-section library and source spectrum altered the radial dose function by 25% and 12%, respectively, but these differences occurred at r = 10 cm where the dose rates were very low. The 2D anisotropy function results were most similar to those of Solberg et al. and most different to those of Meigooni et al. The observed order of simulation condition variables from most to least important for influencing the 2D anisotropy function was spectrum, coating thickness, coating density, and cross-section library. Conclusions: Several MC radiation transport codes are available for calculation of the TG-43 dosimetry parameters for brachytherapy seeds. The physics models in these codes and their related cross-section libraries have been updated and improved since publication of the 2007 AAPM TG-43U1S1 report. Results using modern data indicated statistically significant differences in these dosimetry parameters in comparison to data recommended in the TG-43U1S1 report. Therefore, it seems that professional societies such as the AAPM should consider reevaluating the consensus data for this and others seeds and establishing a process of regular evaluations in which consensus data are based upon methods that remain state-of-the-art.

61 RADIATION PROTECTION AND DOSIMETRY↗

Free software for performing physical analysis of systems for digital radiography and mammography

Purpose: In this paper, the authors present a free software for assisting users in achieving the physical characterization of x-ray digital systems and image quality checks. Methods: The program was developed as a plugin of a well-known public-domain suite ImageJ. The software can assist users in calculating various physical parameters such as the response curve (also termed signal transfer property), modulation transfer function (MTF), noise power spectra (NPS), and detective quantum efficiency (DQE). It also includes the computation of some image quality checks: defective pixel analysis, uniformity, dark analysis, and lag. Results: The software was made available in 2009 and has been used during the last couple of years by many users who gave us valuable feedback for improving its usability. It was tested for achieving the physical characterization of several clinical systems for digital radiography and mammography. Various published papers made use of the outcomes of the plugin. Conclusions: This software is potentially beneficial to a variety of users: physicists working in hospitals, staff working in radiological departments, such as medical physicists, physicians, engineers. The plugin, together with a brief user manual, are freely available and can be found online ( http://www.medphys.it/downloads.htm ). With our plugin users can estimate all three most important parameters used for physical characterization (MTF, NPS, and also DQE). The plugin can run on any operating system equipped with ImageJ suite. The authors validated the software by comparing MTF and NPS curves on a common set of images with those obtained with other dedicated programs, achieving a very good agreement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric effects caused by couch tops and immobilization devices: Report of AAPM Task Group 176

The dosimetric impact from devices external to the patient is a complex combination of increased skin dose, reduced tumor dose, and altered dose distribution. Although small monitor unit or dose corrections are routinely made for blocking trays, ion chamber correction factors, e.g., accounting for temperature and pressure, or tissue inhomogeneities, the dose perturbation of the treatment couch top or immobilization devices is often overlooked. These devices also increase skin dose, an effect which is also often ignored or underestimated. These concerns have grown recently due to the increased use of monolithic carbon fiber couch tops which are optimal for imaging for patient position verification but cause attenuation and increased skin dose compared to the “tennis racket” style couch top they often replace. Also, arc delivery techniques have replaced stationary gantry techniques which cause a greater fraction of the dose to be delivered from posterior angles. A host of immobilization devices are available and used to increase patient positioning reproducibility, and these also have attenuation and skin dose implications which are often ignored. This report of Task Group 176 serves to present a survey of published data that illustrates the magnitude of the dosimetric effects of a wide range of devices external to the patient. The report also provides methods for modeling couch tops in treatment planning systems so the physicist can accurately compute the dosimetric effects for indexed patient treatments. Both photon and proton beams are considered. A discussion on avoidance of high density structures during beam planning is also provided. An important aspect of this report are the recommendations the authors make to clinical physicists, treatment planning system vendors, and device vendors on how to make measurements of surface dose and attenuation and how to report these values. For the vendors, an appeal is made to work together to provide accurate couch top models in planning systems.

60 APPLIED LIFE SCIENCES↗

SU-E-E-03: Developing Solutions to Critical Radiation Oncology Challenges in Tanzania

Purpose: Develop solutions to critical medical physics challenges in Tanzania. Methods: In September of 2013 we began working with Jumaa Bin Dachi, a Therapy Physicist at the Ocean Road Cancer Institute in Dar es Salaam, Tanzania. We developed a bi-lateral learning partnership over the course of eight qualitative Skype meetings with Jumaa. From these meetings we have ascertained that there is a gap between the installation of new equipment and treating patients. This gap has often been overlooked by international partners attempting to improve radiation therapy access. Relationships with academic institutions abroad can fill these gaps, and lead to sustained care of patients needing radiation. Results: Our efforts are best given in a supporting role to help develop solutions and new technology that can reduce the burden on the Medical Physicist. Solutions may include: training material, support for radiation therapy classes, development of appropriate local protocols, and peer-review on documents being produced. New technology needs to focus around simple and easy field shaping, improved patient imaging systems, and systems for patient set-up. We believe our work can help alleviate some of the burdens faced by this institute. Conclusion: While we are just in the beginning stage of this partnership, we believe there is great potential for success between both parties. We hope that the Ocean Road Cancer Institute will benefit from potential funding and resources by partnering with a High Income Country to develop affordable solutions to clinical problems in Tanzania.

60 APPLIED LIFE SCIENCES↗

SU-E-E-07: When the Old Ways Are the Best Ways: In Defense of Didactic Training

Purpose: Physics education for residents has taken on a more prominent role due to the new ABR examination format. We present a curriculum for a new radiology residency entering its second year. This curriculum favors an extensive traditional didactic teaching approach. The curriculum is designed to minimize the amount of independent learning that is necessary outside the classroom Methods and Materials: idactic training repeats yearly for all four years of residency and consists of two 1-hour lectures per week and several in-class tests. The impact of physics on clinical practice is introduced gradually throughout the residency using specific clinical cases. The extensive time spent with the residents allows lectures to be taught at a deep (almost physicist) level and reduces the necessity of learning base concepts outside of lecture. This frees the resident to use resources (e.g., AAPM/RSNA physics modules) to cement concepts through repetition or to learn a slightly confusing concept from a different teaching perspective. Consistent testing reduces the traditional resident studying technique of physics “cramming.” Results: On average, the first year residents scored in the 98th percentile on the American College of Radiology Diagnostic Radiology In-Service Training Exam (ACR DXIT). Feedback from the new first year residents was very positive and suggestions are constantly solicited and incorporated. For example, based on resident feedback, short-format quizzes each lecture were eliminated and replaced interactive questions during lecture. Residents felt they have advanced rapidly and have a better understanding of radiologic physics, though they have expressed concern that the 1-hour lecture block may not be optimal for learning physics. Conclusion: An extensive, physicist-led series of didactic lectures is effective in the teaching of physics to residents.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

SU-E-T-406: Use of TrueBeam Developer Mode and API to Increase the Efficiency and Accuracy of Commissioning Measurements for the Varian EDGE Stereotactic Linac

Purpose: The Varian EDGE machine is a new stereotactic platform, combining Calypso and VisionRT localization systems with a stereotactic linac. The system includes TrueBeam DeveloperMode, making possible the use of XML-scripting for automation of linac-related tasks. This study details the use of DeveloperMode to automate commissioning tasks for Varian EDGE, thereby improving efficiency and measurement consistency. Methods: XML-scripting was used for various commissioning tasks,including couch model verification,beam-scanning,and isocenter verification. For couch measurements, point measurements were acquired for several field sizes (2×2,4×4,10×10cm{sup 2}) at 42 gantry angles for two couch-models. Measurements were acquired with variations in couch position(rails in/out,couch shifted in each of motion axes) compared to treatment planning system(TPS)-calculated values,which were logged automatically through advanced planning interface(API) scripting functionality. For beam scanning, XML-scripts were used to create custom MLC-apertures. For isocenter verification, XML-scripts were used to automate various Winston-Lutz-type tests. Results: For couch measurements, the time required for each set of angles was approximately 9 minutes. Without scripting, each set required approximately 12 minutes. Automated measurements required only one physicist, while manual measurements required at least two physicists to handle linac positions/beams and data recording. MLC apertures were generated outside of the TPS,and with the .xml file format, double-checking without use of TPS/operator console was possible. Similar time efficiency gains were found for isocenter verification measurements Conclusion: The use of XML scripting in TrueBeam DeveloperMode allows for efficient and accurate data acquisition during commissioning. The efficiency improvement is most pronounced for iterative measurements, exemplified by the time savings for couch modeling measurements(approximately 10 hours). The scripting also allowed for creation of the files in advance without requiring access to TPS. The API scripting functionality enabled efficient creation/mining of TPS data. Finally, automation reduces the potential for human error in entering linac values at the machine console,and the script provides a log of measurements acquired for each session. This research was supported in part by a grant from Varian Medical Systems, Palo Alto, CA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-546: Use of Implant Volume for Quality Assurance of Low Dose Rate Brachytherapy Treatment Plans

Purpose: To analyze the application of volume implant (V100) data as a method for a global check of low dose rate (LDR) brachytherapy plans. Methods: Treatment plans for 335 consecutive patients undergoing permanent seed implants for prostate cancer and for 113 patients treated with plaque therapy for ocular melanoma were analyzed. Plaques used were 54 COMS (10 to 20 mm, notched and regular) and 59 Eye Physics EP917s with variable loading. Plots of treatment time x implanted activity per unit dose versus v100 ^.667 were made. V100 values were obtained using dose volume histograms calculated by the treatment planning systems (Variseed 8.02 and Plaque Simulator 5.4). Four different physicists were involved in planning the prostate seed cases; two physicists for the eye plaques. Results: Since the time and dose for the prostate cases did not vary, a plot of implanted activity vs V100 ^.667 was made. A linear fit with no intercept had an r{sup 2} = 0.978; more than 94% of the actual activities fell within 5% of the activities calculated from the linear fit. The greatest deviations were in cases where the implant volumes were large (> 100 cc). Both COMS and EP917 plaque linear fits were good (r{sup 2} = .967 and .957); the largest deviations were seen for large volumes. Conclusions: The method outlined here is effective for checking planning consistency and quality assurance of two types of LDR brachytherapy treatment plans (temporary and permanent). A spreadsheet for the calculations enables a quick check of the plan in situations were time is short (e.g. OR-based prostate planning)

07 ISOTOPE AND RADIATION SOURCES↗

MO-B-16A-02: In Memoriam of Donald D. Tolbert: Surviving the Politics of Radiation Therapy

Today's healthcare work environment is ever-changing and without a doubt will continue to do so for the foreseeable future. How physicists are employed, evaluated, and valued are important aspects of our careers. With increasing demands and challenges being placed on the medical physics workforce, it is important to have the skills and knowledge to prepare for potential challenges to the status-quo of our employment status. Surviving in a world of change, consolidation, increased workload, and financial constraints is not a given, and preparing for those changes and challenges will benefit individuals as well as the medical physics community at large. Learning Objectives: Understand the challenges of succeeding in different work environments. Learn strategies to help define the role of a medical physicist to various administrators, physicians, and department staff and directors. Learn how to successfully communicate and interact with University, Hospital, and Department administrators.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-C-9A-01: Effective Medical Physics Educational Activities: Models and Methods

Medical physics is learned in a combination of activities including classroom sessions, individual study, small-group collaborative problem solving, and direct experience in the laboratory or clinical environment. Each type of learning activity is characterized by its effectiveness in producing the desired knowledge for the learner and the cost in terms of resources and human effort required providing it. While learning and teaching is a human activity, modern technology provides a variety of tools that can be used to enhance human performance. The class or conference room is the common setting for educational sessions in both academic institutions and continuing education conferences and programs such as those sponsored by the AAPM. A major value of a class/conference room program is efficiency by bringing a group of learners together to share in a common learning experience under the guidance of one or more experienced learning facilitators (lecturers or presenters). A major challenge is that the class/conference room is separated from the real world of medical physics. The design of an educational activity needs to take into consideration the desired outcomes with respect to what the learners should be able to do. The distinction is that of being able to apply the knowledge to perform specific physics functions rather than just knowing and being able to recall facts, and perhaps do well on written examinations. These are different types of knowledge structures within the human brain and distinctly different learning activities to develop each. Much of medical physics education, especially at the post-graduate and continuing education level, is for the purpose of enhancing the ability of physicists and other related professionals to perform applied procedures and tasks and requires specific types of knowledge.In this session we will analyze various learning activity models, the values and limitations of each, and how they can be used in medical physics education. An example we will use is optimizing CT image quality and dose which is an important topic for medical physicists, radiologists and residents, along with technologists. The knowledge structure for this is best developed by a combination of learning activities including class/conference discussions, individual study and review, and direct observation and interaction in the clinical setting under the direction of a knowledgeable leader.The function of the human brain will be considered with respect to learning experiences that contribute to effective medical physics knowledge structures. The characteristics of various types of educational activities will be compared with respect to their effectiveness for producing desired outcomes along with their limitations. Emphasis will be given to the design of highly-effective classroom/conference presentations, and activities will be demonstrated with an emphasis on using technology to enhance human performance of both learners and the learning facilitators. Learning Objectives: Develop and provide highly effective medical physics educational sessions. Use technology to enhance human performance in the educational process. Identify and analyze various models of educational activities Select and use educational activities that contribute value to the medical physics profession.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

MO-D-BRF-01: Pediatric Treatment Planning II: The PENTEC Report On Normal Tissue Complications

With advances in multimodality therapy, childhood cancer cure rates approach 80%. However, both radiotherapy and chemotherapy may cause debilitating or even fatal ‘late effects’ that are critical to understand, mitigate, or prevent. QUANTEC identified the uncertainties relating to side-effects of adult treatments, but this is more complicated for children in whom a mosaic of tissues develops at different rates and temporal sequences. Childhood cancer survivors have long life expectancy and may develop treatmentinduced secondary cancers and severe organ/tissue injury decades after treatment. Collaborative long-term observational studies and clinical research programs for survivors of pediatric and adolescent cancer provide some dose-response data for follow-up periods exceeding 40 years. Data analysis is challenging due to the influence of both therapeutic and developmental variables. PENTEC is a group of radiation oncologists, pediatric oncologists, subsepcialty physicians, medical physicists, biomathematic modelers/statisticians, and epidemiologists charged with conducting a critical synthesis of existing literature aiming to: critically analyze radiation dose-volume effects on normal tissue tolerances as a function of age/development in pediatric cancer patients in order to inform treatment planning and improve outcomes for survivors; describe relevant physics issues specific to pediatric radiotherapy; propose dose-volumeoutcome reporting standards to improve the knowledge base to inform future treatment guidelines. PENTEC has developed guidelines for systematic literature reviews, data extraction tolls and data analysis. This education session will discuss:1. Special considerations for normal tissue radiation response of children/adolescents, e.g. the interplay between development and radiotherapy effects.2. Epidemiology of organ/tissue injuries and secondary cancers.3. Exploration of dose-response differences between children and adults4. Methodology for literature review, data mining of outcomes databases, and NTCP or longitudinal modeling of doseresponse. 5. PENTEC goals and timetable. Learning Objectives: Understand important differences between normal tissue effects of radiation therapy in pediatric and adult patients. Be able to identify situations where there is ‘interplay’ between organ development and radiation-induced complications. Identify methods to systematically extract quantitative dose-volumeresponse relationships from existing outcomes databases. Provide guidance for the medical physicist to properly understand, implement, guide and control contemporary technology and applications in pediatric radiation oncology.

60 APPLIED LIFE SCIENCES↗

MO-E-18A-01: Imaging: Best Practices In Pediatric Imaging

This imaging educational program will focus on solutions to common pediatric imaging challenges. The speakers will present collective knowledge on best practices in pediatric imaging from their experience at dedicated children's hospitals. Areas of focus will include general radiography, the use of manual and automatic dose management in computed tomography, and enterprise-wide radiation dose management in the pediatric practice. The educational program will begin with a discussion of the complexities of exposure factor control in pediatric projection radiography. Following this introduction will be two lectures addressing the challenges of computed tomography (CT) protocol optimization in the pediatric population. The first will address manual CT protocol design in order to establish a managed radiation dose for any pediatric exam on any CT scanner. The second CT lecture will focus on the intricacies of automatic dose modulation in pediatric imaging with an emphasis on getting reliable results in algorithmbased technique selection. The fourth and final lecture will address the key elements needed to developing a comprehensive radiation dose management program for the pediatric environment with particular attention paid to new regulations and obligations of practicing medical physicists. Learning Objectives: To understand how general radiographic techniques can be optimized using exposure indices in order to improve pediatric radiography. To learn how to establish diagnostic dose reference levels for pediatric patients as a function of the type of examination, patient size, and individual design characteristics of the CT scanner. To learn how to predict the patient's radiation dose prior to the exam and manually adjust technique factors if necessary to match the patient's dose to the department's established dose reference levels. To learn how to utilize manufacturer-provided automatic dose modulation technology to consistently achieve patient doses within the department's established size-based diagnostic reference range. To understand the key components of an enterprise-wide pediatric dose management program that integrates the expanding responsibilities of medial physicists in the new era of dose monitoring.

60 APPLIED LIFE SCIENCES↗

MO-E-BRE-01: Determination, Minimization and Communication of Uncertainties in Radiation Therapy

Medical Physicists have a general understanding of uncertainties in the radiation treatment process, both with respect to dosimetry and geometry. However, there is a desire to be more quantitative about uncertainty estimation. A recent International Atomic Energy Agency (IAEA) report (about to be published) recommends that we should be as “accurate as reasonably achievable, technical and biological factors being taken into account”. Thus, a single recommendation as a goal for accuracy in radiation therapy is an oversimplification. That report also suggests that individual clinics should determine their own level of uncertainties for their specific treatment protocols. The question is “how do we implement this in clinical practice”? AAPM Monograph 35 (2011 AAPM Summer School) addressed many specific aspects of uncertainties in each of the steps of a course of radiation treatment. The intent of this symposium is: (1) to review uncertainty considerations in the entire radiation treatment process including uncertainty determination for each step and uncertainty propagation for the total process, (2) to consider aspects of robust optimization which optimizes treatment plans while protecting them against uncertainties, and (3) to describe various methods of displaying uncertainties and communicating uncertainties to the relevant professionals. While the theoretical and research aspects will also be described, the emphasis will be on the practical considerations for the medical physicist in clinical practice. Learning Objectives: To review uncertainty determination in the overall radiation treatment process. To consider uncertainty modeling and uncertainty propagation. To highlight the basic ideas and clinical potential of robust optimization procedures to generate optimal treatment plans that are not severely affected by uncertainties. To describe methods of uncertainty communication and display.

60 APPLIED LIFE SCIENCES↗

MO-E-18C-06: Enriching Medical Physics Education By Visualizing The Invisible

Purpose: To enhance the understanding of medical physics concepts and develop higher levels of learning relating to invisible physics phenomena such as radiation. To provide medical physics educators in all countries of the world with understanding of knowledge structures in the human brain, the different levels of learning, and the types of knowledge required for higher level functions such as problem solving, creative innovations, and applied clinical applications. To provide medical physics educators with an open access resource (tool) that they can use in their teaching activities to enrich and elevate the level of learning for their students, residents, etc. with respect to the invisible realm of medical physics. Methods: An experienced clinical medical physicist and educator has created and provided with open access three complementary web-based resources to achieve the purposes described above. One is a module focusing on the medical physics learning process with respect to mental knowledge structures, how they relate to outcomes and applications, and learning activities that are required to develop the required knowledge structures. The second is an extensive set of visuals that educators can use in their activities (classes, small group discussions, etc.) to visualize the invisible. The third is an interactive online simulation where learners can adjust factors and visually observe changes in x-radiation.These resources are available online at www.BLINDED FOR REVIEW . Results: Medical physics education, especially for non-physicists, is becoming much more interesting and useful especially with respect to invisible radiation. The global impact is that medical imaging professionals can be more effective in optimizing x-ray imaging procedures and risk management when they have knowledge levels that enhance problem solving, innovation, and creativity. Conclusion: Medical physics educators in all institutions can be much more effective and efficient in the sharing of their knowledge and experience when enhanced with high-quality visuals.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

MO-F-16A-06: Implementation of a Radiation Exposure Monitoring System for Surveillance of Multi-Modality Radiation Dose Data

Purpose: We have implemented a commercially available Radiation Exposure Monitoring System (REMS) to enhance the processes of radiation dose data collection, analysis and alerting developed over the past decade at our sites of practice. REMS allows for consolidation of multiple radiation dose information sources and quicker alerting than previously developed processes. Methods: Thirty-nine x-ray producing imaging modalities were interfaced with the REMS: thirteen computed tomography scanners, sixteen angiography/interventional systems, nine digital radiography systems and one mammography system. A number of methodologies were used to provide dose data to the REMS: Modality Performed Procedure Step (MPPS) messages, DICOM Radiation Dose Structured Reports (RDSR), and DICOM header information. Once interfaced, the dosimetry information from each device underwent validation (first 15–20 exams) before release for viewing by end-users: physicians, medical physicists, technologists and administrators. Results: Before REMS, our diagnostic physics group pulled dosimetry data from seven disparate databases throughout the radiology, radiation oncology, cardiology, electrophysiology, anesthesiology/pain management and vascular surgery departments at two major medical centers and four associated outpatient clinics. With the REMS implementation, we now have one authoritative source of dose information for alerting, longitudinal analysis, dashboard/graphics generation and benchmarking. REMS provides immediate automatic dose alerts utilizing thresholds calculated through daily statistical analysis. This has streamlined our Closing the Loop process for estimated skin exposures in excess of our institutional specific substantial radiation dose level which relied on technologist notification of the diagnostic physics group and daily report from the radiology information system (RIS). REMS also automatically calculates the CT size-specific dose estimate (SSDE) as well as provides two-dimensional angulation dose maps for angiography/interventional procedures. Conclusion: REMS implementation has streamlined and consolidated the dosimetry data collection and analysis process at our institutions while eliminating manual entry error and providing immediate alerting and access to dosimetry data to both physicists and physicians. Brent Stewart has funded research through GE Healthcare.

60 APPLIED LIFE SCIENCES↗

MO-G-9A-01: Imaging Refresher for Standard of Care Radiation Therapy

Imaging techniques and technology which were previously the domain of diagnostic medicine are becoming increasingly integrated and utilized in radiation therapy (RT) clinical practice. As such, there are a number of specific imaging topics that are highly applicable to modern radiation therapy physics. As imaging becomes more widely integrated into standard clinical radiation oncology practice, the impetus is on RT physicists to be informed and up-to-date on those imaging modalities relevant to the design and delivery of therapeutic radiation treatments. For example, knowing that, for a given situation, a fluid attenuated inversion recovery (FLAIR) image set is most likely what the physician would like to import and contour is helpful, but may not be sufficient to providing the best quality of care. Understanding the physics of how that pulse sequence works and why it is used could help assess its utility and determine if it is the optimal sequence for aiding in that specific clinical situation. It is thus important that clinical medical physicists be able to understand and explain the physics behind the imaging techniques used in all aspects of clinical radiation oncology practice. This session will provide the basic physics for a variety of imaging modalities for applications that are highly relevant to radiation oncology practice: computed tomography (CT) (including kV, MV, cone beam CT [CBCT], and 4DCT), positron emission tomography (PET)/CT, magnetic resonance imaging (MRI), and imaging specific to brachytherapy (including ultrasound and some brachytherapy specific topics in MR). For each unique modality, the image formation process will be reviewed, trade-offs between image quality and other factors (e.g. imaging time or radiation dose) will be clarified, and typically used cases for each modality will be introduced. The current and near-future uses of these modalities and techniques in radiation oncology clinical practice will also be discussed. Learning Objectives: To review the basic physical science principles of CT, PET, MR, and ultrasound imaging. To understand how the images are created, and present their specific role in patient management and treatment planning for therapeutic radiation (both external beam and brachytherapy). To discuss when and how each specific imaging modality is currently used in clinical practice, as well as how they may come to be used in the near future.

60 APPLIED LIFE SCIENCES↗