Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance contracting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Performance Testing of a Moving-Bed Gasifier Using Coal, Biomass, and Waste Plastic Blends to Generate White Hydrogen

The objective of this DOE-funded project by the Electric Power Research Institute, Inc. (EPRI), Hamilton Maurer International (HMI) and Sotacarbo S.p.A. (Sotacarbo), is to qualify coal, biomass, and plastic waste blends based on performance testing of selected pellet recipes in a pilot-scale updraft moving-bed gasifier. The testing provides relevant data to advance the commercial-scale design of the moving-bed gasifier to be able to successfully use these feedstocks to produce hydrogen. In particular, the effects of the waste plastics on feedstock development (i.e., blending and pelletizing) and the resulting products (i.e., syngas compositions, organic condensate production, and ash characteristics) are a focus. The gasifier is Hamilton Mauer International, Inc. (HMI)’s moving-bed gasifier, which has been proven capable of gasifying nearly all coal ranks. It has also shown the ability in prior testing work to gasify wood chips. However, mixtures of these fuels with plastic wastes had not yet been prepared and gasified together. The feedstocks were prepared by California Pellet Mill (CPM) under contract to HMI. The technical tasks for this research project included: • Feed Procurement and Preparation: Nine different feedstocks were prepared from varying compositions of PRB coal, corn stover biomass, and car fluff waste plastics. Fuel pellets were produced by California Pellet Mill (CPM) and shipped to Sotacarbo’s test facility in Italy. • Test Plan Development: A test plan was created to define the test runs to be performed. The test plan detailed the different tests that were run, instrumentation used, extractive samples taken, and relevant figures of merit. • Gasifier Testing: Tests were performed in the pilot-scale gasifier at Sotacarbo using nine different fuel feedstocks generated from varying mixtures of coal, biomass, and plastic wastes. The testing provides information on gasification reaction efficiency/performance, yielding relevant data for models used to scale up the gasifier design. This task will also included work to reassemble the gasifier at Sotacarbo and perform a baseline 100% coal run. • Data Analysis and Reporting: Review of the data, determination of figures of merit, and interpretation of the results was reported. The results can be used to specify the range of feedstock blends that can be successfully gasified as well as quantify gasifier outputs based on specific blends. The tri-fuel pelletizing conducted at CPM and gasification testing results from Sotacarbo’s 30mm up draft moving bed gasifier are significant. Providing data for an established gasifier to help accelerate its updated design to be able to accommodate feedstocks composed of coal, biomass, and plastic waste. This should ultimately lead to development and commercialization of a lower cost, white hydrogen generation system.

01 COAL, LIGNITE, AND PEAT↗

Gasification of Mixed Blends of Coal, Biomass, and Plastic Waste

The objective of this DOE-funded project by the Electric Power Research Institute, Inc. (EPRI), Hamilton Maurer International (HMI) and Sotacarbo S.p.A. (Sotacarbo), is to qualify coal, biomass, and plastic waste blends based on performance testing of selected pellet recipes in a pilot-scale updraft moving-bed gasifier. The testing provides relevant data to advance the commercial-scale design of the moving-bed gasifier to be able to successfully use these feedstocks to produce hydrogen. In particular, the effects of the waste plastics on feedstock development (i.e., blending and pelletizing) and the resulting products (i.e., syngas compositions, organic condensate production, and ash characteristics) are a focus. The gasifier is Hamilton Mauer International, Inc. (HMI)’s moving-bed gasifier, which has been proven capable of gasifying nearly all coal ranks. It has also shown the ability in prior testing work to gasify wood chips. However, mixtures of these fuels with plastic wastes had not yet been prepared and gasified together. The feedstocks were prepared by California Pellet Mill (CPM) under contract to HMI. The technical tasks for this research project included: • Feed Procurement and Preparation: Nine different feedstocks were prepared from varying compositions of PRB coal, corn stover biomass, and car fluff waste plastics. Fuel pellets were produced by California Pellet Mill (CPM) and shipped to Sotacarbo’s test facility in Italy. • Test Plan Development: A test plan was created to define the test runs to be performed. The test plan detailed the different tests that were run, instrumentation used, extractive samples taken, and relevant figures of merit. • Gasifier Testing: Tests were performed in the pilot-scale gasifier at Sotacarbo using nine different fuel feedstocks generated from varying mixtures of coal, biomass, and plastic wastes. The testing provides information on gasification reaction efficiency/performance, yielding relevant data for models used to scale up the gasifier design. This task will also included work to reassemble the gasifier at Sotacarbo and perform a baseline 100% coal run. • Data Analysis and Reporting: Review of the data, determination of figures of merit, and interpretation of the results was reported. The results can be used to specify the range of feedstock blends that can be successfully gasified as well as quantify gasifier outputs based on specific blends. The tri-fuel pelletizing conducted at CPM and gasification testing results from Sotacarbo’s 30mm up draft moving bed gasifier are significant. Providing data for an established gasifier to help accelerate its updated design to be able to accommodate feedstocks composed of coal, biomass, and plastic waste. This should ultimately lead to development and commercialization of a lower cost, white hydrogen generation system.

01 COAL, LIGNITE, AND PEAT↗

Vedizar Fingerprinter

SAND2025-03289O Vedizar Fingerprinter simplifies the process of identifying devices on a network by analyzing traffic data. It uses a unique library to recognize different devices, making it easier for users to understand what is happening on their networks. This software is ideal for IT and operational technology environments, helping organizations monitor their networks effectively. By saving results in a database, it allows for easy access and review of device information. Users can enhance their network security and optimize performance without needing specialized hardware or technical expertise. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Jacobellis, John [Sandia National Lab. (SNL-CA), L↗

SetEnvironment

SAND2025-11727O SetEnvironment software is a utility library module that uses ConfigParserEnhanced, also a library module, to read specifically formatted .ini files for setting the user's environment. It creates a consistent environment with an expected set of variables and module loads, which is important for testing. Environment variable operations include set, append, prepend, unset, remove, and others and uses the Python os.environ methods. The module operations are performed with a wrapper. Systems using the Lmod package can generate a module function, which can also perform module operations specified in the text file. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

McLendon III, William↗

Monthly Sewer Monitoring Report for LLNL Livermore Site (Jun 2020)

Lawrence Livermore National Laboratory (LLNL) collects effluent samples from its sewer outfall at the B196 Sewer Monitoring Station (SMS). Effluent flow-proportional composite samples are collected at the SMS on a daily (midnight-to-midnight), weekly (Thursday through Wednesday), and “monthly” (composited from daily) basis; effluent grab samples are also collected each month at that same location. Certified contract laboratories analyze these compliance samples, and results are used to establish LLNL compliance with the 2019 - 2020 Wastewater Discharge Permit (Permit 1250) granted by the City of Livermore Water Resources Division (WRD). Supplemental analyses for biochemical oxygen demand (BOD) and total suspended solids (TSS) are performed onsite and reported for the calculation and assessment of sewer service charges. Quarterly, effluent is sampled for metals (24-hour composite) and cyanide (grab sample) concentrations (mg/L).

54 ENVIRONMENTAL SCIENCES↗

Ionic Contraction across the Lanthanide Series Decreases the Temperature-Induced Disorder of the Water Coordination Sphere

In liquid, temperature affects the structures of lanthanide complexes in multiple ways that depend upon complex interactions between ligands, anions, and solvent molecules. The relative simplicity of lanthanide aqua ions (Ln 3+ ) make them well suited to determine how temperature induces structural changes in lanthanide complexes. In this work, we performed a combination of ab initio molecular dynamics (AIMD) simulations and extended X-ray absorption fine structure (EXAFS) measurements, both at 25 and 90 °C, to determine how temperature affects the first- and second-coordination spheres of three Ln 3+ (Ce 3+ , Sm 3+ , and Lu 3+ ) aqua ions. AIMD simulations show first lanthanide coordination spheres that are similar at 25 and 90 °C, more so for the Lu 3+ ion that remains as eight-coordinate than for the Ce 3+ and Sm 3+ ions that change their preferred coordination number from nine (at 25 °C) to eight (at 90 °C). The measured EXAFS spectra are very similar at 25 and 90 °C, for the Ce 3+ , Sm 3+ , and Lu 3+ ions, suggesting that the dynamical disorder of the Ln 3+ ions in liquid water is sufficient such that temperature-induced changes do not clearly manifest changes in the structure of the three ions. Both AIMD simulations and EXAFS measurements show very similar structures of the first coordination sphere of the Lu 3+ ion at 25 and 90 °C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Implementation of McMurchie–Davidson Algorithm for Gaussian AO Integrals Suited for SIMD Processors

We report an implementation of the McMurchie− Davidson evaluation scheme for 1- and 2-particle Gaussian AO integrals designed for processors with Single Instruction Multiple Data (SIMD) instruction sets. Like in our recent MD implementation for graphical processing units (GPUs) [Asadchev, A.; Valeev, E. F.. J. Chem. Phys. 2024, 160, 244109.], variable-sized batches of shellsets of integrals are evaluated at a time. By optimizing for the floating point instruction throughput rather than minimizing the number of operations, this approach achieves up to 50% of the theoretical hardware peak FP64 performance for many common SIMD-equipped platforms (AVX2, AVX512, NEON), which translates to speedups of up to 30 over the state-of-the-art one-shellset-at-a-time implementation of Obara−Saika-type schemes in Libint for a variety of primitive and contracted integrals. As with our previous work, we rely on the standard C++ programming language such as the std::simd standard library feature to be included in the 2026 ISO C++ standard without any explicit code generation to keep the code base small and portable. The implementation is part of the open source LibintX library freely available at https://github.com/ValeevGroup/libintx.

Basis sets↗

Proactive Intrusion Detection and Mitigation System

SAND2023-05661O The proactive intrusion detection and mitigation system (PIDMS) provides grid-edge situational awareness for cybersecurity defense by capturing real-time distributed energy resource (DER) network traffic and performance data with a novel approach that improves the detection and prevention of cyber-physical attacks. The PIDMS addresses the grid-edge security gap with real-time analysis of both network traffic and photovoltaic performance data to deliver a novel, cyber-physical intrusion detection system (IDS) approach that increases the accuracy and effectiveness of detection and mitigation. This hybrid IDS analysis enables dual monitoring that increases the workload of the adversary; both cyber and physical data would have to be simultaneously spoofed to evade detection. Furthermore, monitoring and analyzing cyber data are insufficient in some cases. For example, in an insider threat aimed at disrupting inverter grid-support functions where proper credentials and authentication are achieved, only the altered PV performance would indicate abnormal behavior. All in all, the PIDMS provides novel capabilities for: • Distributed, real-time cyber-physical detection and mitigation analysis • Cybersecurity defense for grid-edge systems • Analysis framework that can provide situational awareness across the transmission, distribution, and DER systems The PIDMS sensor is designed to collect cyber-physical data, process the data using machine-learning algorithms, detect abnormal events, and deploy mitigations. With these goals, the main functional PIDMS objectives are: • Capability to collect cyber-physical data • Onboard storage of cyber-physical data • Peer-to-peer communication • Computationally efficient machine-learning algorithms • Online cyber-physical data analysis • Alerting/visualization capabilities • Mitigation deployment capability with bump-in-the-wire (BITW) implementation Each of these functional objectives enable PIDMS to perform effective cyber-physical intrusion detection and mitigation. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Jones, Christian↗

Performance Testing of a Moving-Bed Gasifier Using Coal, Biomass, and Waste Plastic Blends to Generate White Hydrogen

The objective of this DOE-funded project by the Electric Power Research Institute, Inc. (EPRI), Hamilton Maurer International (HMI) and Sotacarbo S.p.A. (Sotacarbo), is to qualify coal, biomass, and plastic waste blends based on performance testing of selected pellet recipes in a pilot-scale updraft moving-bed gasifier. The testing will provide relevant data to advance the commercial-scale design of the moving-bed gasifier to be able to successfully use these feedstocks to produce hydrogen. In particular, the effects of the waste plastics on feedstock development (i.e., blending and pelletizing) and the resulting products (i.e., syngas compositions, organic condensate production, and ash characteristics) are a focus. The gasifier is Hamilton Mauer International, Inc. (HMI)’s moving-bed gasifier, which has been proven capable of gasifying nearly all coal ranks. It has also shown the ability in prior testing work to gasify wood chips. However, mixtures of these fuels with plastic wastes have not been prepared and gasified together. The feedstocks will be prepared by California Pellet Mill (CPM) under contract to HMI. The technical tasks and current status for this two-year research project are: Feed Procurement and Preparation: Nine different feedstocks were prepared from varying compositions of PRB coal, corn stover biomass, and car fluff waste plastics. Fuel pellets were produced by California Pellet Mill and shipped to Sotacarbo’s test facility in Italy. Test Plan Development: A test plan was created to define the test runs to be performed. The test plan detailed the different tests that were run, instrumentation used, extractive samples taken, and relevant figures of merit. Gasifier Testing: Tests are currently being performed in the pilot-scale gasifier at Sotacarbo using nine different fuel feedstocks generated from varying mixtures of coal, biomass, and plastic wastes. The testing will provide information on gasification reaction efficiency/performance, yielding relevant data for models used to scale up the gasifier design. This task will also include work to reassemble the gasifier at Sotacarbo and perform a baseline 100% coal run. Data Analysis and Reporting: Review of the data, determination of figures of merit, and interpretation of the results to be reported. The results will be used to specify the range of feedstock blends that can be successfully gasified as well as quantify gasifier outputs based on specific blends. This paper will be summarize the pelletizing procedure that insures the viability of the tri-fuel pellets for the gasification runs that are being performed at Sotacarbo’s 30mm up draft moving bed gasifier. Initial gasification tests have been conducted, and all the lab scale tri-fuel pellet gasification runs will be completed by the fall of 2022. Performance data will enable modeling of a full-scale HMI industrial scale gasifier supporting both CHP and Hydrogen production.

01 COAL, LIGNITE, AND PEAT↗

Variational Kalman Filtering with Hinf-Based Correction v.1.0

SAND2024-01664O This software demonstrates the usage of the Variational Kalman Filtering with Hinf-Based Correction software, which can be used to calculate the mean and covariance of the estimate of a high-dimensional parameter. The software performs this task faster than the traditional Kalman filtering technique. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

SciDAC↗

Linv_hfem3d

SAND2022-14658 O Linv-hfem3d uses geophysical electrical (E) field data to perform automated wellbore integrity monitoring at an affordable computational cost. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Beskardes, Gungor↗

Structural Simluation Toolkit (SST) v.12.0

The Structural Simulation Toolkit (SST) was developed to explore innovations in highly concurrent computing systems where the instruction set architecture (ISA), micro-architecture, and memory interact with the programming model and communications system. The package provides a fully modular design for extensive exploration of an individual system parameter as well as a parallel simulation environment based on message passing interface (MPI) which enable a high level of performance as well as the ability to look at large systems. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Rodrigues, ArunF.↗

norma-opinf

SAND2025-10454O norma-opinf is a set of tools to perform operator inference. It is specifically tailored for the norma codebase. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Tezaur, Irina [Sandia National Lab. (SNL-CA), Live↗

NSVA-3 Spectrum Adjustment Code

SAND2025-03756O The NSVA-3 Spectrum Adjustment Code performs a least-square spectrum adjustment on multiple neutron fields and provides a best-estimate neutron spectrum and associated uncertainty. The code was developed to perform a least-square spectrum adjustment for neutron benchmark fields. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Griffin, Patrick↗

Monthly Sewer Monitoring Report for LLNL Livermore Site, April 2020

Lawrence Livermore National Laboratory (LLNL) collects effluent samples from its sewer outfall at the B196 Sewer Monitoring Station (SMS). Effluent flow-proportional composite samples are collected at the SMS on a daily (midnight-to-midnight), weekly (Thursday through Wednesday), and “monthly” (composited from daily) basis; effluent grab samples are also collected each month at that same location. Certified contract laboratories analyzes these compliance samples, and results (Tables 1–3) are used to establish LLNL compliance with the 2019–2020 Wastewater Discharge Permit (Permit 1250) granted by the City of Livermore Water Resources Division (WRD). Supplemental analyses for biochemical oxygen demand (BOD) and total suspended solids (TSS) are performed onsite and reported (Table 4) for the calculation and assessment of sewer service charges. Quarterly, effluent is sampled for metals (24-hour composite) and cyanide (grab sample) concentrations (mg/L). The results are presented in Table 5. In addition to the sampling noted above, the SMS continuously monitors LLNL sewage effluent in real-time for flow rate, pH, metals, and radioactivity. Standard measurement methods are used to monitor flow and pH to determine permit compliance. Unique nonstandard analytical methods monitor for the presence of metals and radioactivity using x-ray fluorescence (XRF) and gamma spectroscopy, respectively. If an anomalous condition is detected by the monitoring system, an alarm activates LLNL’s Sewer Diversion Facility (SDF) and Livermore Water Reclamation Plant (LWRP) operators are notified that a potential release has occurred.

54 ENVIRONMENTAL SCIENCES↗

Continuous Monitoring and Partial Water Softening for Cooling Tower Water Treatment

Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. They are the point in the system where heat is dissipated to the atmosphere through the evaporative cooling process. Cooling towers are commonly found in industrial applications and are also often used in water-cooled chilled water plants in medium to large commercial buildings. Continuous monitoring and partial water softening for cooling towers used in medium to large commercial buildings are the focus of this paper. Cooling towers consume large amounts of water. Cooling tower-related water consumption is one of largest potable water loads within buildings in the United States, with substantial building water use associated with heating and cooling. Regional water shortages have highlighted a need to reduce water consumption; the U.S. General Services Administration (GSA) and Executive Order 13834 place priority on reducing water consumption. This priority has fueled interest in the identification, investigation, and potential broad deployment of cost-effective opportunities to reduce water use, such as alternative water treatment (AWT) technologies for cooling towers. Traditional water treatment approaches use chemicals to extend the ability of the water to hold scaling minerals in suspension, minimize corrosion, and prevent biological growth. This treatment protects the chillers and cooling tower equipment; however, even when chemicals are used regularly, a certain percentage of condenser water must be drained and made up with fresh water to maintain system water quality parameters. In addition, the use of chemicals sometimes creates a waste disposal issue and can cause building owners to incur additional fees, such as disposal or wastewater charges. To manage cooling tower water treatment, GSA typically contracts with a company specializing in conventional chemical maintenance for a fixed fee. While there are many types and vendors of AWT systems, this project assesses the effectiveness of one technology provided by Aqualogix. This system is a chilled water plant monitoring and control system aimed at optimizing system performance by reducing the blowdown occurrences used to remove mineral build-up. The technology consists of two components – continuous programmable logic control (PLC) monitoring and side-stream filtration with partial water softening. PLC monitoring calculates cycles of concentration (CoC) and determines the optimum amount of blowdown water required to satisfy all water chemistry requirements. Side-stream filtration removes suspended matter and improves biocide efficacy while precisely dispensing softened water to achieve optimal makeup water hardness. Unlike other AWT systems evaluated by GSA to date, this system does not replace the legacy treatment system but is used in addition to chemical water treatment. The vendor claims their technology will reduce water consumption, water discharge, and maintenance costs. The AWT system evaluated in this demonstration is a commercialized technology. Given its commercialized state, the system evaluated in this report is at a Technology Readiness Level 9 according to National Aeronautics and Space Administration (NASA) definitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

HAERO: High-performance aerosols

SAND2021-15059 O Haero is a software library for representing aerosol size distributions, chemical species, and parameterized processes to use with a coupled atmospheric dynamics model or as a standalone tool. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Bosler, Peter↗

Interstitial Nature of Mn 2+ Doping in 2D Perovskites

Halide perovskites doped with magnetic impurities (such as the transition metals Mn 2+ , Co 2+ , Ni 2+ ) are being explored for a wide range of applications beyond photovoltaics, such as spintronic devices, stable light-emitting diodes, single-photon emitters, and magneto-optical devices. However, despite several recent studies, there is no consensus on whether the doped magnetic ions will predominantly replace the octahedral B-site metal via substitution or reside at interstitial defect sites. Here, by performing correlated nanoscale X-ray microscopy, spatially and temporally resolved photoluminescence measurements, and magnetic force microscopy on the inorganic 2D perovskite Cs 2 PbI 2 Cl 2 , we show that doping Mn 2+ into the structure results in a lattice expansion. The observed lattice expansion contrasts with the predicted contraction expected to arise from the B-site metal substitution, thus implying that Mn 2+ does not replace the Pb 2+ sites. Photoluminescence and electron paramagnetic resonance measurements confirm the presence of Mn 2+ in the lattice, while correlated nano-XRD and X-ray fluorescence track the local strain and chemical composition. Density functional theory calculations predict that Mn 2+ atoms reside at the interstitial sites between two octahedra in the triangle formed by one Cl – and two I – atoms, which results in a locally expanded structure. These measurements show the fate of the transition metal dopants, the local structure, and optical emission when they are doped at dilute concentrations into a wide band gap semiconductor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗