Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peak flows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Aerodynamic performance of 0.4066-scale model to JT8D refan stage

The aerodynamic performance of a scale model of the split flow JT8D rafan stage is presented over a range of flows at speeds from 40 to 100 percent design. The bypass stage peak efficiency of 0.800 occurred at a total weight flow of 35.82 kilograms per second and a pressure ratio of 1.697. The stall margin was 15 percent based on pressure ratio and weight flow at stall and peak efficiency conditions. The data indicated that the hub region of the core stators was choked at design speed over the entire flow range tested.

Moore, R. D.↗

Analysis of normal shock noise measurements on nose-cylinder bodies.

Aerodynamic noise measurements have been obtained on three nose-cylinder configurations (15 deg cone-cylinder, biconic nose-cylinder and biconic nose-corrogated cylinder) in transonic flow. The noise environment at the foot of the terminal normal shock and its associated separated flow bubble were examined in detail. A peak in the frequency spectra of the separated flow region was observed which compares well with the predicted resonance frequency of the separated pocket using Trilling's incident shock model. As a consequence of the observed sound spectra and noise level, a flow model is postulated which consist of a cellular separated flow region. In the central portion of the cell the flow resembles the classical two-dimensional recirculating bubble, but each cell is vented by a pair of counter rotating vortices, which start at the surface and steam downstream.

Reding, J. P.↗

Integrated modeling of cryogenic layered highfoot experiments at the NIF

Integrated radiation hydrodynamic modeling in two dimensions, including the hohlraum and capsule, of layered cryogenic HighFoot Deuterium-Tritium (DT) implosions on the NIF successfully predicts important data trends. The model consists of a semi-empirical fit to low mode asymmetries and radiation drive multipliers to match shock trajectories, one dimensional inflight radiography, and time of peak neutron production. Application of the model across the HighFoot shot series, over a range of powers, laser energies, laser wavelengths, and target thicknesses predicts the neutron yield to within a factor of two for most shots. The Deuterium-Deuterium ion temperatures and the DT down scattered ratios, ratio of (10–12)/(13–15) MeV neutrons, roughly agree with data at peak fuel velocities <340 km/s and deviate at higher peak velocities, potentially due to flows and neutron scattering differences stemming from 3D or capsule support tent effects. These calculations show a significant amount alpha heating, 1–2.5× for shots where the experimental yield is within a factor of two, which has been achieved by increasing the fuel kinetic energy. This level of alpha heating is consistent with a dynamic hot spot model that is matched to experimental data and as determined from scaling of the yield with peak fuel velocity. Lastly, these calculations also show that low mode asymmetries become more important as the fuel velocity is increased, and that improving these low mode asymmetries can result in an increase in the yield by a factor of several.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Columbia River Treaty History and 2014/2024 Review

The Columbia River, the fourth largest river on the continent as measured by average annual flow, generates more power than any other river in North America. While its headwaters originate in British Columbia, only about 15 percent of the 259,500 square miles of the Columbia River Basin is actually located in Canada. Yet the Canadian waters account for about 38 percent of the average annual volume, and up to 50 percent of the peak flood waters, that flow by The Dalles Dam on the Columbia River between Oregon and Washington. In the 1940s, officials from the United States and Canada began a long process to seek a joint solution to the flooding caused by the unregulated Columbia River and to the postwar demand for greater energy resources. That effort culminated in the Columbia River Treaty, an international agreement between Canada and the United States for the cooperative development of water resources regulation in the upper Columbia River Basin. It was signed in 1961 and implemented in 1964.

power, treaty, history, hydroelectric, Columbia Ri↗

Bridging the gap between peak and average loads on science networks

Backbone networks are typically overprovisioned in order to support peak loads. Research and education networks (RENs), for example, are often designed to operate at 20–30% of capacity. Thus, Internet2 upgrades its backbone interconnects when the weekly 95th-percentile load is reliably above 30% of link capacity, and analysis of ESnet traffic between major laboratories shows a substantial gap between peak and average utilization. As science data volumes increase exponentially, it is unclear whether this overprovisioning trend can continue into the future. Even if overprovisioning is possible, it may not be the most cost-effective (and desirable) approach going forward. Under the current mode of free access to RENs, traffic at peak load may include both flows that need to be transferred in near-real time–for example, for computation and instrument monitoring and steering–and flows that are less time-critical, for example, archival and storage replication operations. Thus, peak load does not necessarily indicate the capacity that is absolutely required at that moment. We thus examine how data transfers are impacted when the average network load is increased while the network capacity is kept at the current levels. We also classify data transfers into on-demand (time-critical) and best-effort (less time-critical) and study the impact on both classes for different proportions of both the number of on-demand transfers and amount of bandwidth allocated for on-demand transfers. For our study, we use real transfer logs from production GridFTP servers to do simulation-based experiments as well as real experiments on a testbed. We find that when the transfer load is doubled and the network capacity is fixed at the current level, the gap between peak and average throughput decreases by an average of 18% in the simulation experiments and 16% in the testbed experiments, and the average slowdown experienced by the data transfers is under 1.5×. Moreover, when transfers are classified as on-demand or best-effort, on-demand transfers experience almost no slowdown and the mean slowdown experienced by best-effort transfers is under 2× in the simulation experiments and under 1.2× in the testbed experiments.

97 MATHEMATICS AND COMPUTING↗

The discovery of large amounts of cold, X-ray absorbing matter in cooling flows

The discovery of significant excess absorption in the X-ray spectra of 12 clusters of galaxies is reported. The spectra also require a cooling-flow component, which confirms the results of imaging studies of the clusters showing the strongly peaked emission characteristic of cooling flows. The total mass of absorbing gas is determined on the assumption that it is distributed through the cooling flow region and has cosmic abundance. It is shown that the gas is most likely in the form of small cold clouds. The excess absorption is interpreted as being due to photoelectric absorption in cold gas clouds distributed through the cooling flows.

White, D. A.↗

Examining Passenger Flow Choke Points at Airports Using Discrete Event Simulation

The movement of passengers through an airport quickly, safely, and efficiently is the main function of the various checkpoints (check-in, security. etc) found in airports. Human error combined with other breakdowns in the complex system of the airport can disrupt passenger flow through the airport leading to lengthy waiting times, missing luggage and missed flights. In this paper we present a model of passenger flow through an airport using discrete event simulation that will provide a closer look into the possible reasons for breakdowns and their implications for passenger flow. The simulation is based on data collected at Norfolk International Airport (ORF). The primary goal of this simulation is to present ways to optimize the work force to keep passenger flow smooth even during peak travel times and for emergency preparedness at ORF in case of adverse events. In this simulation we ran three different scenarios: real world, increased check-in stations, and multiple waiting lines. Increased check-in stations increased waiting time and instantaneous utilization. while the multiple waiting lines decreased both the waiting time and instantaneous utilization. This simulation was able to show how different changes affected the passenger flow through the airport.

Brown, Jeremy R.↗

Experimental and theoretical comparison of ion properties from nanosecond laser-produced plasmas of metal targets

The ion emission properties of laser-produced plasmas as a function of laser intensities between 4–50 GW cm –2 and varying angles with respect to the target normal were investigated. The plasmas were produced by focusing 1064 nm, 6 ns pulses from an Nd:YAG laser on various metal targets. The targets used for this study include Ti, Mo, and Gd (Z = 22, 42, 64). It is noted that all ion profiles are composed of multiple peaks—a prompt emission peak trailed by three ion peaks (ultrafast, fast, and thermal). Experimentally, it is shown that each of these ion peaks follows a unique trend as a function of laser intensity, angle, and distance away from the target. Theoretically, it is shown that simple analytical models can be used to explain the properties of the ions. The variations in the ion velocity and density as a function of laser intensity are found to be in good agreement with theoretical models of sheath acceleration, isothermal self-similar expansion, and ablative plasma flow for various ion peaks.

42 ENGINEERING↗

BULK FLOW OF HALOS IN {Lambda}CDM SIMULATION

Analysis of the Pangu N-body simulation validates that the bulk flow of halos follows a Maxwellian distribution with variance that is consistent with the prediction of the linear theory of structure formation. We propose that the consistency between the observed bulk velocity and theories should be examined at the effective scale of the radius of a spherical top-hat window function yielding the same smoothed velocity variance in linear theory as the sample window function does. We compared some recently estimated bulk flows from observational samples with the prediction of the {Lambda}CDM model we used; some results deviate from expectation at a level of {approx}3{sigma}, but the discrepancy is not as severe as previously claimed. We show that bulk flow is only weakly correlated with the dipole of the internal mass distribution, that the alignment angle between the mass dipole and the bulk flow has a broad distribution peaked at {approx}30 Degree-Sign -50 Degree-Sign , and also that the bulk flow shows little dependence on the mass of the halos used in the estimation. In a simulation of box size 1 h {sup -1} Gpc, for a cell of radius 100 h {sup -1} Mpc the maximal bulk velocity is >500 km s{sup -1}; dipoles of the environmental mass outside the cell are not tightly aligned with the bulk flow, but are rather located randomly around it with separation angles {approx}20 Degree-Sign -40 Degree-Sign . In the fastest cell there is a slightly smaller number of low-mass halos; however, halos inside are clustered more strongly at scales {approx}> 20 h {sup -1} Mpc, which might be a significant feature since the correlation between bulk flow and halo clustering actually increases in significance beyond such scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of global/chemistry model for jet-fuel thermal stability based on observations from static and flowing experiments

Two global-chemistry models for oxidative deposition of jet fuels are evaluated by integrating them into a Computational Fluid Dynamics with Chemistry (CFDC) code. A previously developed two-step global-chemistry model was found to be insufficient to describe the thermal-oxidation and -deposition rates associated with a Jet-A fuel. A new global-chemistry model has been developed systematically based on observations from flowing and static experiments. The global-autoxidation reaction is modified such that the reaction rate becomes zeroth-order with respect to the dissolved oxygen concentration. The generation of deposit-forming precursor is coupled with the autoxidation reaction by introducing a radical species ROO. A formulation for the sticking probability has also been developed. Deposition profiles are well represented by this new model under a variety of temperature and flow conditions. The model correctly predicts the changes in magnitude and spatial location of the deposition peak due to changes in flow. The CFDC model, which is designed for flowing systems, has been extended to static experiments. The model incorporates a non-depleting species F(sub s) representing all non-oxygen compounds responsible for deposition. Static experiments were found to provide a useful and inexpensive method for estimating the concentration of F(sub s) in the fuel.

V. R. Katta↗

Effect of Various Blade Modifications in Performance of a 16-Stage Axial-flow Compressor. IV - Effect on Over-all Performance Characteristics of Decreasing Twelfth through Fifteenth Stage Stator-blade Angles 3 deg and Increasing Stator Angles in the Inlet Stages

The performance of a 16-stage axial-flow compressor, in which two modifications of unloaded inlet stages were combined with loaded exit stages, has been determined. In the first modification the exit stages were loaded by decreasing the twelfth through fifteenth stage stator angles 3 deg. as compared with the blade angles in the original compressor, and the inlet stages were unloaded by increasing the blade angles the following amounts: guide vanes and first-stage stator, 6 deg; second- and third-stage stators, 4 deg.; and fourth-stage stators, 3 deg. The over-all performance of this configuration was compared with that of the compressor with the original blade angles. The peak efficiency was increased at all speeds below design and the weight flow was higher at speeds below 80 percent of design, the same at 80 percent of design, and lower at speeds abovce 80 percent of design. The maximum reduction in weight flow occurred at design speed. The surge limit line was higher at speeds between 75 and 90 percent of design when presented on a pressure ratio against weight flow basis. The second configuration was the same as the first with the exception that the second-, third-, and fourth-stage stator blade angles were the same as in the compressor with the original blade angles. A comparison of the performance of this configuration with that of the compressor with the original blade angles showed the same general trends of changes in performance as the first configuration. Comparisons were made of compressor configurations to show the effects upon the performance of decreased loading in the inlet stages. Below 75 percent of design speed, decreased loading results in increased weight flow and peak efficiency; above 80 percent of design speed, decreased loading in the inlet stages results in decreased weight flow and small changes in peak efficiencies. Between 75 and 90 percent of design the changes in surge weight flow and pressure ratio were such that the surge limit line was raised with decreased loading in the inlet stages when presented as pressure ratio against weight flow.

Hatch, James E.↗

Performance of transonic fan stage with weight flow per unit annulus area of 198 kilograms per second per square meter (40.6(lb/sec)/sq ft)

The overall and blade-element performance are presented for an air compressor stage designed to study the effect of weight flow per unit annulus area on efficiency and flow range. At the design speed of 424.8 m/sec the peak efficiency of 0.81 occurred at the design weight flow and a total pressure ratio of 1.56. Design pressure ratio and weight flow were 1.57 and 29.5 kg/sec (65.0 lb/sec), respectively. Stall margin at design speed was 19 percent based on the weight flow and pressure ratio at peak efficiency and at stall.

Kovich, G.↗

Rotor redesign for a highly loaded 1800 ft/sec tip speed fan, 2

Tests were conducted on a 0.5 hub/tip ratio single-stage fan designed to produce a pressure ratio of 2.280 at an efficiency of 83.8 percent with a rotor tip speed of 548.6 m/sec (1800 ft/sec). The rotor was designed utilizing a quasi three dimensional design system and four-part, multiple-circular-arc airfoil sections. The rotor is the third in a series of single-stage fans that have included a precompression airfoil design and a multiple-circular-arc airfoil design. The stage achieved a peak efficiency of 82.8 percent after performance had deteriorated by 0.6 of a point. The design mass flow was achieved at the peak efficiency point, and the stage total pressure ratio was 2.20, which is lower than the design goal of 2.28. The surge margin of 13% from the peak efficiency point exceeded the design goal of 7%.

Bolt, C. R.↗

Aerothermodynamic Environment Definition for the Genesis Sample Return Capsule

NASA's Genesis sample return mission will be the first to return material from beyond the Earth-Moon system. NASA Langley Research Center supported this mission with aerothermodynamic analyses of the sample return capsule. This paper provides an overview of that effort. The capsule is attached through its forebody to the spacecraft bus. When the attachment is severed prior to Earth entry, forebody cavities remain. The presence of these cavities could dramatically increase the heating environment in their vicinity and downstream. A combination of computational fluid dynamics calculations and wind tunnel phosphor thermography tests were employed to address this issue. These results quantify the heating environment in and around the cavities, and were a factor in the decision to switch forebody heat shield materials. A transition map is developed which predicts that the flow aft of the penetrations will still be laminar at the peak heating point of the trajectory. As the vehicle continues along the trajectory to the peak dynamic pressure point, fully turbulent flow aft of the penetrations could occur. The integrated heat load calculations show that a heat shield sized to the stagnation point levels will be adequate for the predicted environment aft of the penetrations.

Cheatwood, F. McNeil↗

Quantifying CTFE content in FK-800 using ATR-FTIR and time to peak crystallization

The chlorotrifluoroethylene (CTFE) content in vinylidene fluoride (VDF)-CTFE copolymers greatly influences the chemical and physical properties and ultimately determines the application. The copolymer known as FK-800 has a VDF:CTFE ratio of ~1:3 and is used almost exclusively as the binder in the insensitive high explosive (HE) formulation PBX 9502. Due to the dangerous nature of HE work and the effect CTFE content variations have, the ability to quickly and easily quantify CTFE content is of interest. Two techniques, attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) and time to peak crystallization measured by heat flow calorimetry, were evaluated here as potential means for quantifying CTFE content. Based on the certificate of analyses (COAs), FK-800 lots with varied CTFE content encompassing the range historically used in HE applications were used as standards for both methodologies. For FTIR, a linear regression was performed on the peak area of the C-Cl IR stretch and the CTFE content; the methodology was then demonstrated on four samples, two lots of unadulterated material and material recovered from two HE samples. The calculated CTFE content and COAs were in good agreement for all four samples. Heat flow calorimetry revealed the relationship between time to peak crystallization and CTFE content was best fit by a power regression; the methodology was then tested on two different FK-800 lots. Only one sample showed good agreement between the calculated CTFE content and the COA. This discrepancy indicates the method developed is not suitable for quantifying CTFE, but provides valuable insight regarding the crystallization behavior of VDF-CTFE copolymers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance of J33-A-27 Turbojet-Engine Compressor: Center for Infrastructure Engineering Studies - 1

The J33-A-27 compressor was operated at an inlet pressure of 14 inches of mercury absolute and ambient inlet temperature over a range of equivalent impeller speeds from 6100 to 11,800 rpm. At the design equivalent speed of 11,800 rpm, the J33-A-27 compressor had a peak pressure ratio of 4.40 at an equivalent weight flow of 105.7 pounds per second and a peak adiabatic temperature-rise efficiency of 0.745. The maximum equivalent weight flow at design speed was 113.5 pounds per second.

Kovach, Karl↗

System efficiency of packed bed TES with radial flow vs. axial flow – Influence of aspect ratio

Here, this paper compares the net system efficiency, including thermal efficiency and pressure drop effects, of radial versus axial flow packed beds for thermal energy storage. The traditional packed bed system is a cylindrical geometry where fluid flows axially from one end to another. However, issues of thermal stratification and high-pressure drop have led to recent studies on radial flow systems. One potential benefit is the reduced pressure drop in a radial flow system. This paper compares the performance of radial flow and axial flow systems at a range of aspect ratios (AR = H/D bed ) from 0.21 to 1.92 using a numerical model where the storage volume is held constant in all cases. When the radial flow bed is at a low aspect ratio (short/wide), the thermal front is improved but the pressure drop is high. At a high aspect ratio, the velocity is reduced in radial flow, leading to decreased pressure drop but an increased spreads in the thermal front that lowers thermal efficiency. The opposite trends are noted in axial flow. Thermal efficiencies of 83–91 % were noted for radial flow, while they ranged from 85 to 94 % in axial flow. Net efficiencies including pressure drop ranged from 74 to 82 % for radial flow and 80–87 % for axial flow. In both systems, a peak net efficiency was noted between the highest and lowest aspect ratio. While some aspect ratios with radial flow outperform axial flow from a net efficiency perspective, the results show that the highest net efficiency from axial flow is higher than that from radial flow. Overall, this paper highlights the importance of innovative TES designs and their potential to improve energy efficiency.

25 ENERGY STORAGE↗

Three-dimensional flow field in the tip region of a compressor rotor passage. I - Mean velocity profiles and annulus wall boundary layer

A rotating three-sensor, hot-wire probe has been used along with rotor blade static pressure measurements to investigate the complex inviscid and viscid effects in the annulus wall flowfield, including the three components of mean velocity, turbulence intensity, and turbulence stress inside the rotor blade passage. It is found that the tip leakage flow originates near quarter-chord, with peak values occurring near mid-chord. The leakage flow, which is in the form of a jet within the blade row, is augmented by the blade rotation and travels further away from the suction surface than that observed in stationary blade rows and cascades. This leakage flow tends to roll up between the mid-passage and the pressure surface near the tip region; the vortex formation does not occur within the passage in this particular case.

Lakshminarayana, B.↗