Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “particle filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

ExINP NSA Ice Nucleating Particle Concentrations

This data set comprises cumulative ambient ice-nucleating particle (INP) concentrations measured at the National Oceanic and Atmospheric Administration's (NOAA’s) Barrow Atmospheric Baseline Observatory (71.3230° N, 156.6114° W, “BRW” hereafter), next to the Atmospheric Radiation Measurement (ARM) North Slope of Alaska (NSA) site and ~ 6 km northeast of the town of Utqiaġvik. Our INP abundance data were generated using a combination of online instrument, the Portable Ice Nucleation Experiment chamber ver. 3 (PINE-03), and an offline cold stage, the West Texas Cryogenic Refrigerator Applied to Freezing Test system (WT-CRAFT). Our online INP data are all from the Examining the Ice-Nucleating Particles from NSA (ExINP-NSA) campaign conducted from October 19, 2021 to May 24, 2024. The offline INP concentration analysis was performed at West Texas A&M University for aerosol particle samples collected on polycarbonate filters (with 0.2-micron diameter pores). The PINE-03 measurements, as well as sampling activities for offline INP measurements, were conducted using the BRW site. An inset laminar sampling stack was mounted to the instrument platform, allowing PINE-03 to intake particle-laden air. For most of the campaign period, the semi-autonomous PINE-03 chamber was remotely controlled from West Texas A&M University using the LabView interface through the BeyondTrust remote-access console. PINE-03 was set to conduct an immersion freezing expansion experiment (i.e., simulated adiabatic cooling along with RHw at or above 100%). Except during the scheduled maintenance periods, the time resolution of each expansion experiment was approximately 12 minutes. PINE-03 continuously measured INP concentrations during the entire campaign without any substantial breaks. For most of the campaign period, PINE scanned its set-point vessel air temperatures from -14 °C to -31 °C and back to -14 °C about every 120 minutes.

54 ENVIRONMENTAL SCIENCES↗

ExINP NSA Ice Nucleating Particle Concentrations

This data set comprises cumulative ambient ice-nucleating particle (INP) concentrations measured at the National Oceanic and Atmospheric Administration's (NOAA’s) Barrow Atmospheric Baseline Observatory (71.3230° N, 156.6114° W, “BRW” hereafter), next to the Atmospheric Radiation Measurement (ARM) North Slope of Alaska (NSA) site and ~ 6 km northeast of the town of Utqiaġvik. Our INP abundance data were generated using a combination of online instrument, the Portable Ice Nucleation Experiment chamber ver. 3 (PINE-03), and an offline cold stage, the West Texas Cryogenic Refrigerator Applied to Freezing Test system (WT-CRAFT). Our online INP data are all from the Examining the Ice-Nucleating Particles from NSA (ExINP-NSA) campaign conducted from October 19, 2021 to May 24, 2024. The offline INP concentration analysis was performed at West Texas A&M University for aerosol particle samples collected on polycarbonate filters (with 0.2-micron diameter pores). The PINE-03 measurements, as well as sampling activities for offline INP measurements, were conducted using the BRW site. An inset laminar sampling stack was mounted to the instrument platform, allowing PINE-03 to intake particle-laden air. For most of the campaign period, the semi-autonomous PINE-03 chamber was remotely controlled from West Texas A&M University using the LabView interface through the BeyondTrust remote-access console. PINE-03 was set to conduct an immersion freezing expansion experiment (i.e., simulated adiabatic cooling along with RHw at or above 100%). Except during the scheduled maintenance periods, the time resolution of each expansion experiment was approximately 12 minutes. PINE-03 continuously measured INP concentrations during the entire campaign without any substantial breaks. For most of the campaign period, PINE scanned its set-point vessel air temperatures from -14 °C to -31 °C and back to -14 °C about every 120 minutes.

54 ENVIRONMENTAL SCIENCES↗

A collection of diverse micrometeorites recovered from 100 tonnes of Antarctic blue ice

A new type of meteoritic material, intermediate in size between meteorites and interplanetary dust particles (IDPs), is described. Melting and filtering of about 100 tons of blue ice near Cap Prudhomme, Antarctica, yielded 7500 or more irregular, friable particles and about 1500 melted spherules, about 100 microns in size, both showing a 'chondritic' composition suggestive of an extraterrestrial origin. Analyzed irregular particles appear to be unmelted and have similarities with the fine-grained matrix of primitive carbonaceous chondrites, but are extremely diverse in composition. Isotopic analysis of trapped neon confirms an extraterrestrial origin for 16 of 47 irregular particles and 2 of 19 spherules studied and strongly suggests that they were exposed in space as micrometeoroids. These large Antarctic micrometeorites constitute a new family, or at least a new population, of solar system objects, in a mass range corresponding to the bulk of extraterrestrial material accreted by the earth today.

Maurette, M.↗

High-gradient magnetic separation of colloidal uranium oxide particles from soil components in aqueous suspensions

The separation of uranium oxide (UO 2 ) particles from soil-surrogate particles in aqueous suspensions was achieved using filtration enhanced by a magnetic field. Enhanced attraction of paramagnetic UO 2 colloids to a ferromagnetic stainless-steel filter placed in a strong magnetic field arises because of the positive magnetic susceptibility of the particles and the high-gradient field generated near ferromagnetic fibers. Enhanced uptake of smaller particles over larger ones occurs through Brownian motion that promotes the collision of particles with the ferromagnetic fibers of the filter. Hence, this work focused on UO 2 particles in the colloidal size range. Experiments used a water-cooled electromagnet and an array of permanent magnets. Chemical analysis showed that the magnetic field increased the capture efficiency of uranium particles from a range of 27–53% with the magnet off up to 98% with the magnet on after a single pass of the suspension through the filter. Further, the recovery of the UO 2 particles from the filter, however, was more difficult to achieve. Small amounts of UO 2 , together with significant amounts of background SiO 2 particles, were removed from the filter during a first flush with the magnetic field on. A much larger recovery of UO 2 was not observed until a second out-of-field flush was performed, which also released some SiO 2 . The degree to which particle separation was enhanced through the use of multi-stage filtration compared to single pass-through filtration was also examined. A design was suggested that could be used to optimize the separation efficiency for a continuous process.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Aerosol-Assisted Deposition for TiO 2 Immobilization on Photocatalytic Fibrous Filters for VOC Degradation

Atomization and spraying are well-established methods for the production of submicrometer- and micrometer- sized powders. In addition, they could be of interest to the immobilization of photocatalytic nanoparticles onto supports because they enable the formation of microporous films with photocatalytic activity. Here, we provide a comparison of aerosol-assisted immobilization methods, such as spray-drying (SD), spray atomization (SA), and spray gun (SG), which were used for the deposition of TiO 2 dispersions onto fibrous filter media. The morphology, microstructure, and electronic properties of the structures with deposited TiO 2 were characterized by SEM and TEM, BET and USAXS, and UV-Vis spectrometry, respectively. The photocatalytic performances of the functionalized filters were evaluated and compared to the benchmark dip-coating method. Our results showed that the SG and SA immobilization methods led to the best photocatalytic and operational performance for the degradation of toluene, whereas the SD method showed the lowest degradation efficiency and poor stability of coating. We demonstrated that TiO2 sprays using the SG and SA methods with direct deposition onto filter media involving dispersed colloidal droplets revealed to be promising alternatives to the dip-coating method owing to the ability to uniformly cover the filter fibers. In addition, the SA method allowed for fast and simple control of the coating thickness as the dispersed particles were continuously directed onto the filter media without the need for repetitive coatings, which is common for the SG and dip-coating methods. Our study highlighted the importance of the proper immobilization method for the efficient photocatalytic degradation of VOCs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CERES Clouds and Radiative Swath (CRS) data in HDF. (CER_CRS_Terra-FM1-MODIS_Edition2B)

The Clouds and Radiative Swath (CRS) product contains one hour of instantaneous Clouds and the Earth's Radiant Energy System (CERES) data for a single scanner instrument. The CRS contains all of the CERES SSF product data. For each CERES footprint on the SSF the CRS also contains vertical flux profiles evaluated at four levels in the atmosphere: the surface, 500-, 70-, and 1-hPa. The CRS fluxes and cloud parameters are adjusted for consistency with a radiative transfer model and adjusted fluxes are evaluated at the four atmospheric levels for both clear-sky and total-sky. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1998-01-01; Stop_Date=2005-12-31] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Temporal_Resolution=1 hour; Temporal_Resolution_Range=Hourly - < Daily].

SHORTWAVE FLUX↗

Recalibrated Equations for Determining Effect of Oil Filtration on Rolling Bearing Life

In 1991, Needelman and Zaretsky presented a set of empirically derived equations for bearing fatigue life (adjustment) factors (LFs) as a function of oil filter ratings. These equations for life factors were incorporated into the reference book, "STLE Life Factors for Rolling Bearings." These equations were normalized (LF = 1) to a 10-micrometer filter rating at Beta(sub x) = 200 (normal cleanliness) as it was then defined. Over the past 20 years, these life factors based on oil filtration have been used in conjunction with ANSI/ABMA standards and bearing computer codes to predict rolling bearing life. Also, additional experimental studies have been made by other investigators into the relationship between rolling bearing life and the size, number, and type of particle contamination. During this time period filter ratings have also been revised and improved, and they now use particle counting calibrated to a new National Institute of Standards and Technology (NIST) reference material, NIST SRM 2806, 1997. This paper reviews the relevant bearing life studies and describes the new filter ratings. New filter ratings, Beta(sub x(c)) = 200 and Beta(sub x(c)) = 1000, are benchmarked to old filter ratings, Beta(sub x) = 200, and vice versa. Two separate sets of filter LF values were derived based on the new filter ratings for roller bearings and ball bearings, respectively. Filter LFs can be calculated for the new filter ratings.

Needelman, William M.↗

Quantifying the Impacts of PM2.5 Constituents and Relative Humidity on Visibility Impairment in a Suburban Area of Eastern Asia Using Long-Term In-Situ Measurements.

The deterioration of visibility due to air pollutants and relative humidity has been a serious environmental problem in eastern Asia. In most previous studies, chemical compositions of atmospheric particles were provided using filter-based offline analyses, which were unable to provide long-term and in-situ measurements that resolve sufficient temporal variations of air pollution and meteorology, hindering the resolution of the relationship between air quality and visibility. Here, we present a year-long continuously measured data from a comprehensive suite of online instruments to investigate diurnal and seasonal impacts of the aerosol chemical compositions in PM2.5 on visibility seasonally and diurnally. The measured dry aerosol extinction at λ = 550 nm reached a closure with that predicted by aerosol compositions within 12%. However, the hygroscopic growth of particles under ambient RH could enhance the aerosol extinction by a factor of 2 – 6, matching the perceptive visibility of the public. Particulate ammonium nitrate was most sensitive to reducing visibility, while ammonium sulfate contributed the most to the light extinction. In spring and winter, the monsoon and stagnant air masses reduced the visibility and increased PM2.5 (> 35 μg m-3).The moisture was found to substantially enhance the light extinction under RH = 60 – 90%,reducing visibility by approximately 15 km, largely attributed to hygroscopic inorganic salts.This study serves as a metric to highlight the need to consider the influence of RH, and aqueous reactions in producing secondary inorganic aerosols on atmospheric visibility, underpinning the more accurate mitigation strategies of air pollution.

visibility↗

MARCUS Ice Nucleating Particle Measurements (revised 7/2020)

These data list ice nucleating particle (INP) number concentrations active in the immersion freezing mode. Aerosol filters were collected during 4 voyages of the Aurora Australis vessel from 02 November 2017 to 22 March 2018, as part of the Measurements of Aerosols, Radiation and Clouds over the Southern Ocean (MARCUS) study. These voyages transected the Southern Ocean from Hobart, Tasmania to four Australian Antarctic Division stations, including three in Antarctica. Collections were made over alternating periods of 24 and 48 hours using open-faced polycarbonate filters that were approximately 18 m MSL, sited near the AOS trailer and other AMF measurements. The volume of air filtered ranged from 19000 to 38000 standard liters per filter sample. Filters were stored and returned frozen to Colorado State University (CSU), where immersion freezing measurements over a range from 0 to -28 degC were made using the CSU Ice Spectrometer (IS). Collected particles from each filter were resuspended in filtered, deionized water, and then dispensed into the IS and cooled to obtain cumulative INP temperature spectra. Aliquots of suspensions from selected samples were also heat treated (95 degC for 20 min) to denature and deactivate biological INPs, and digested in 10% H2O2 at 95 degC under UV-B for 20 min to remove all organic carbon INPs, prior to measurement using the IS.

54 ENVIRONMENTAL SCIENCES↗

Accelerated Aging Humidity Chamber for Nuclear Grade HEPA Filter Media

A unique accelerated aging humidity chamber for simulating the natural aging process of nuclear grade high efficiency particulate air (HEPA) filter media is being designed, implemented, and tested. The nuclear industry currently lacks information regarding the shelf life and service life of HEPA filter media. The Department of Energy recommends disposing of HEPA filters 10 years after the manufacture date for filters operated under dry conditions. Studies have shown the tensile strength and water repellency of HEPA filter media diminish with age. The chamber's principal function is to sustain an elevated relative humidity condition for an extended duration specified by the Arrhenius aging model. To accomplish this, various design parameters were established: (1) consistently achieve uniform humidity conditions within the chamber to equally expose media sheets, (2) ensure the chamber is sufficiently sealed to mitigate the uncontrolled infiltration of air, (3) confidently secure the media sheets to avert the introduction of unnecessary stressing/creasing, (4) fabricate the chamber from clear polycarbonate material to allow inspection of the media sheets, (5) provide a safe and ergonomic design for personnel, (6) ensure the chamber design is replicable and relatively easy to fabricate/assemble. A humidity source, fan, PID controller, humidity and temperature transmitters, and data loggers are required for proper operation and control of the chamber. The humidity source must accommodate target values up to 95% relative humidity throughout the chamber. The three humidity and temperature transmitters are strategically spaced throughout the chamber to ensure uniform conditions. The 10 cubic feet per minute (CFM) fan selected intends to accomplish the desired air change rate inside the chamber of approximately 20 air changes per hour (ACH). The 2 plenums on the upper and lower portions of the chamber utilize a perforated design to uniformly distribute air, promote air mixing, and control the air velocity entering the chamber. Industrial blueprint hanging clamps are being retrofitted to be seated within the chamber drawers and firmly secure the nuclear grade filter media. The aged media will be evaluated using autopsy methodology, and the results obtained intend to help clarify the useful life of nuclear grade HEPA filters. Nuclear grade high efficiency particulate air (HEPA) filters are defined as disposable, extended-media, dry-type filters with a rigid casing enclosing the full depth of the pleats and have a minimum particle removal efficiency of 99.97%. [1] - HEPA filters are constantly exposed to stressors and subsequently have been shown to degrade as the filter ages. Properties such as tensile strength and water repellency, along with others, are negatively impacted. [2] - Due to the scarcity of naturally aged HEPA filters available, it is crucial to develop accelerated aging methods which effectively mimic the natural degradation effects. - After accelerated aging, the filters are subject to testing in the Axial Flow Large Scale Test Stand (ALSTS) and other analysis techniques such as the same qualification tests performed directly after being manufactured. - Quality data is necessary for future decisions regarding the lifetime of nuclear grade HEPA filters. - The objective is to develop a prototype accelerated aging humidity chamber for nuclear grade HEPA filter media. The chamber should expose the media to commonly occurring stressors to expedite the degradation process caused by aging. PID yields reliable and reproducible results: - CFD model correlates well with actual performance; - Further analysis is needed to complete characterization; - Future work for the chamber is still to be completed. The data shown in Figure 5 and Table 1 indicate the system is functioning as designed. As can be determined from the system response evaluation in Table 1, the PID controller is yielding reliable and reproducible results at each set point. As the set point increases, the time constant and 20% settling time increase accordingly. From the results in Table 1, it stands to reason that the CFD model correlates well with the actual performance of the system. Each system response parameter for the 90%RH* CFD model is slightly lower than the parameters collected from the physical model tested at an equivalent set point. This is to be expected considering the inlet in the CFD model is a constant supply of water vapor, whereas the physical model uses a PID controller to monitor the amount of water vapor needed and reacts accordingly. More analysis is still to be done on the prototype chamber. A pressure test will be conducted in order to determine the hourly leak rate of the chamber. This test will involve constant air flow into the chamber until the desired pressure is reached. A uniformity test will also be conducted in order to ensure each filter medium is being exposed to equivalent relative humidity levels. This test will involve an array of humidity meters strategically oriented inside the chamber to record any possible gradients. Future work for the chamber includes dehumidification abilities, tests while fully loaded with filters, and temperature control. Once completed, the autopsy team at Institute of Clean Energy Technology will conduct necessary accelerated aging studies as needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of particle size on the capture of uranium oxide colloidal particles from aqueous suspensions via high-gradient magnetic filtration

The effectiveness of High Gradient Magnetic Filtration (HGMF) in capturing uranium oxide particles from suspensions was investigated in this study. Two sets of experiments were performed to evaluate the importance of size on the capture of uranium oxide particles. The first considered two batches sieved into size bins of< 5, 5–10, 10–15, and 15–20 µm, while the second was performed using two suspensions with diameters smaller than 1.0 µm and between 1.0 and 1.5 µm. Iron oxide experiments, with particles between 0.3 and 0.8 µm, were performed for calibration purposes. In all experiments, a surfactant (Triton-X100 or sodium dodecyl sulfate) was used to prevent particle aggregation and limit the influence of non-magnetic capture mechanisms. A magnetic field of approximately 1.1 Tesla was generated using a water cooled electromagnet. HGMF was performed using tubular filters packed with ferromagnetic stainless-steel wool. Of the initial four uranium oxide particle sizes, magnetic capture was only observed for particles with a diameter of less than 5 µm, while larger particles experienced no magnetic and minimal total capture. For particles with diameters smaller than 1.0 µm and between 1.0 and 1.5 µm, capture efficiencies increased by 39 ± 9% and 34 ± 6% respectively, solely due to the magnetic field. Although the magnetic force is proportional to particle diameter, the capture efficiency decreased as diameter increased. So these results suggest that Brownian diffusion, which is influential for micron sized particles and increases with decreasing particle size, is acting in conjunction with the magnetic force to influence the efficacy of HGMF for uranium oxide. This important finding underscores the effectiveness of Brownian diffusion in increasing the rate of collision between particles and collector fibers. A stochastic trajectory model was developed to incorporate the influence of Brownian motion on particle behavior and filter removal efficiency. Modeling results are discussed and compared for uranium and iron oxide particles.

42 ENGINEERING↗

Characterization of Iron and Organic Carbon Colloids in Boreal Rivers and Their Fate at High Salinity

Riverine colloids are important carriers of macronutrients, trace metals, and pollutants into marine waters. The aim of the current study was to extend the understanding of iron (Fe) and organic carbon (OC) colloids in boreal rivers and their fate at higher salinities. X-ray absorbance spectroscopy (XAS) and dynamic light scattering (DLS) were combined to explore Fe speciation and colloidal characteristics such as size and surface charge and how these are affected at increasing salinity. XAS confirmed the presence of two Fe phases in the river waters—Fe-organic matter (OM) complexes and Fe(oxy)hydroxides. From DLS measurements on filtered and unfiltered samples, three particle size distributions were identified. The smallest particles (10–40 nm) were positively charged and suggested to consist of essentially bare Fe (oxy)hydroxide nanoparticles. The largest particles (300–900 nm) were dominated by Fe(oxy)hydroxides associated with chromophoric molecular matter. An intermediate size distribution (100–200 nm) with a negative surface charge was presumably dominated by OM and containing Fe-OM complexes. Increasing the salinity resulted in a removal of the smallest distribution. Unexpectedly, both the intermediate and largest size distributions were still detected at high salinity. The collective results suggest that Fe(oxy) hydroxides and Fe-OM complexes are both found across the wide size range studied and that colloidal size does not necessarily reflect either Fe speciation or stability toward salinity-induced aggregation. The findings further demonstrate that also particles beyond the typically studied <0.45-μm size range should be considered to fully understand the riverine transport and fate of macronutrients, trace metals, and pollutants.

54 ENVIRONMENTAL SCIENCES↗

Search for the Tunguska event in the Antarctic snow

The Tunguska explosion in 1908 is supposed to have been produced by the impact of a small celestial body. The absence of any identifiable crater together with the huge energy released by the event suggest that the impactor exploded in midair and that its material was widely spread over the Earth. The short term contribution of such exceptional events to the total accretion rate of extraterrestrial material by the Earth could be significant. Samples were chosen in a core electromechanically drilled in 1984 near South Pole Station. There, the low temperatures, preventing melting all year long, and the nearly regular snow fall rate provide good conditions for a reliable continuous record of any infalling material. In many samples Ir was below the detection limit of the instrumentation. The iridium infall averaged over 45 samples is given. In a few samples the iridium content is significantly higher than the average: the frequency and amplitude of such fluctuations can be explained by the presence on some filters of finite size cosmic particles. No significant systematic increase above the average level is observed in the part of the core corresponding to the Tunguska event. The two major results of this study are: (1) The presence of Tunguska explosion debris in the Antarctic snow is not confirmed; and (2) The estimate of the average iridium infall, is an order of magnitude lower than the Ganapathy's background but is close to the values measured in Antarctic snow and atmospheric samples by Takahashi et al. The results are also consistent with the flux of micrometeoroids deduced from optical and radar observations or derived from the study of Greenland cosmic dust collection but are lower than the flux at mid-latitude measured in paleocene-oligocene sediments from the central part of the Pacific Ocean.

Rocchia, R.↗

Nuclear Thermal Rocket Element Environmental Simulator (NTREES) Upgrade Activities

Over the past year the Nuclear Thermal Rocket Element Environmental Simulator (NTREES) has been undergoing a significant upgrade beyond its initial configuration. The NTREES facility is designed to perform realistic non-nuclear testing of nuclear thermal rocket (NTR) fuel elements and fuel materials. Although the NTREES facility cannot mimic the neutron and gamma environment of an operating NTR, it can simulate the thermal hydraulic environment within an NTR fuel element to provide critical information on material performance and compatibility. The first phase of the upgrade activities which was completed in 2012 in part consisted of an extensive modification to the hydrogen system to permit computer controlled operations outside the building through the use of pneumatically operated variable position valves. This setup also allows the hydrogen flow rate to be increased to over 200 g/sec and reduced the operation complexity of the system. The second stage of modifications to NTREES which has just been completed expands the capabilities of the facility significantly. In particular, the previous 50 kW induction power supply has been replaced with a 1.2 MW unit which should allow more prototypical fuel element temperatures to be reached. The water cooling system was also upgraded to so as to be capable of removing 100% of the heat generated during. This new setup required that the NTREES vessel be raised onto a platform along with most of its associated gas and vent lines. In this arrangement, the induction heater and water systems are now located underneath the platform. In this new configuration, the 1.2 MW NTREES induction heater will be capable of testing fuel elements and fuel materials in flowing hydrogen at pressures up to 1000 psi at temperatures up to and beyond 3000 K and at near-prototypic reactor channel power densities. NTREES is also capable of testing potential fuel elements with a variety of propellants, including hydrogen with additives to inhibit corrosion of certain potential NTR fuel forms. Additional diagnostic upgrades included in the present NTREES set up include the addition of a gamma ray spectrometer located near the vent filter to detect uranium fuel particles exiting the fuel element in the propellant exhaust stream to provide additional information any material loss occurring during testing. Other aspects of the upgrade included reworking NTREES to reduce the operational complexity of the system despite the increased complexity of the induction heating system. To this end, many of the controls were consolidated on fewer panels. As part of this upgrade activity, the Safety Assessment (SA) and the Standard Operating Procedures (SOPs) for NTREES were extensively rewritten. The new 1.2 MW induction heater consists of three physical units consisting of a transformer, rectifier, and inverter. This multiunit arrangement facilitated increasing the flexibility of the induction heater by more easily allowing variable frequency operation. Frequency ranges between 20 and 60 kHz can be accommodated in the new induction heater allowing more representative power distributions to be generated within the test elements.

Emrich, William J., Jr.↗

ELM: Europa Luminescence Microscope

The Europa Luminescence Microscope (ELM) is an automated fluorescence and bright-field microscope designed to meet key objectives defined in the 2016 NASA Europa Lander Study Report, including the identification and characterization of morphological biosignatures. ELM’s heritage stems from a 2U cubesat fluorescence microscope, the Fluorescence Analysis for In situ Research imager, designed and built at NASA Ames Research Center, for the autonomous study of microbial biology in low Earth orbit. For ELM implementation, a sample is autonomously manipulated with a microfluidic system using in-line 10, 1.0, and 0.2 μm pore-size filters to capture successively smaller particles for imaging. For bright-field imaging, ELM uses deep-ultraviolet, ultraviolet and visible light to image organic and inorganic structures with submicron resolution. The ability to detect biosignatures as small as 0.2 μm in size is achieved by imaging native fluorescence and using fluorescence microscopy stains to identify key structural and functional indicators of microbial life (proteins, lipids, nucleic acids). For fluorescence imaging, ELM uses 265, 370, 470, and 530 nm LEDs with five emission bands. The use of multiple excitation and emission wavelengths for native fluorescence imaging enables the detection of a wide range of molecular species and their rough classification. Excitation at 265 nm allows for the detection of smaller polycyclic aromatic hydrocarbons (PAH), aromatic amino acids, and proteins with little to no interference from mineral fluorescence, given proper emission band selection. 370 and 470 nm light excites increasingly larger PAH structures and larger aromatic biomolecules that may be present (e.g., protective pigments). Similarly, inorganic fluorescence can be characterized and separated from organic fluorescence, allowing the recognition and in some cases classification, of minerals and other abiotic particles. ELM is based upon work supported by the NASA COLDTech and ICEE-2 programs.

Richard C Quinn↗

Variable-focus magnetostatic lens

Variable-focus solenoidal lenses for charged particle beams with integrated emittance filtering are disclosed. The emittance may be controlled via selection of collimating irises. The focal length may be changed by altering the spacing between two permanent ring magnets.

Lewellen, John↗

Low-Pressure Generator Makes Cleanrooms Cleaner

Scientists at NASA's Kennedy Space Center work in cleanrooms: laboratories with high degrees of cleanliness provided by strict control of particles such as dust, lint, or human skin. They are contaminant-free facilities, where the air is repeatedly filtered, and surfaces are smooth to prevent particles from getting lodged. Technicians working in these environments wear specially designed cleanroom "bunny suits" and booties over their street clothes, as well as gloves and face masks to avoid any contamination that may be imparted from the outside world. Even normal paper is not allowed in cleanrooms, only cleanroom low-particulate paper. These are sensitive environments where precision work, like the production of silicon chips or hard disk drives, is performed. Often in cleanrooms, positive air pressure is used to force particles outside of the isolated area. The air pressure in the Kennedy cleanrooms is monitored using high-accuracy, low-differential pressure transducers that require periodic calibration. Calibration of the transducers is a tricky business. In prior years, the analysis was performed by sending the transducers to the Kennedy Standards Laboratory, where a very expensive cross-floated, labor- intensive, dead-weight test was conducted. In the early 1990s, scientists at Kennedy determined to develop a technique and find equipment to perform qualification testing on new low-differential pressure transducers in an accurate, cost-effective manner onsite, without requiring an environmentally controlled room. They decided to use the highly accurate, cost-effective Setra Model C264 as the test transducer. For qualification testing of the Setra, though, a portable, lower-cost calibrator was needed that could control the differential pressure to a high degree of resolution and transfer the accuracy of the Standards Laboratory testing to the qualification testing. The researchers decided that, to generate the low-differential pressure setpoints needed for qualification testing, very small gas volume changes could be made against the test article, and a corresponding pressure change would be detected by a pressure standard. This allowed the researchers to recreate cleanroom air pressure settings without the use of a cleanroom. Thus was born the low-differential pressure generator. In 1993, a prototype was developed using a pair of PVC tanks, a volume controller, and a 1-pound-per-square-inch pressure standard. By 1995, the prototype was perfected into the unit that is still used today.

Source record↗

Miniaturized Optical Particle Counter (MOPC) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) aerosol counting, composition, extinction, and sizing system (ACCESS) includes a base module (9400), a filter sampler (9401), an advanced mixing condensation particle counter (MCPC, 9403), a miniaturized optical particle counter (mOPC, 9405), and a single-channel tricolor absorption photometer (STAP, 9406). This handbook focuses on the mOPC, which measures the aerosol particle size distribution between 0.19 and 3 μm.

54 ENVIRONMENTAL SCIENCES↗