Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “outdoor testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Noise of a model helicopter rotor due to ingestion of turbulence

A theoretical and experimental investigation of the noise of a model helicoper rotor due to ingestion of turbulence was conducted. Experiments were performed with a 0.76 m dia, articulated model rotor for a range of inflow turbulence and rotor operating conditions. Inflow turbulence levels varied from approximately 2 to 19 percent and tip Mach number was varied from 0.3 to 0.52. Test conditions included ingestion of a atmospheric turbulence in outdoor hover as well as ingestion of grid generated isotropic turbulence in the wind tunnel airstream. In wind tunnel testing, both forward flight and vertical ascent (climb) were simulated. Far field noise spectra and directivity were measured in addition to incident turbulence intensities, length scales, and spectra. Results indicate that ingestion of atmospheric turbulence is the dominant helicopter rotor hover noise mechanism at the moderate to high frequencies which determine perceived noise level.

Paterson, R. W.↗

Laboratory Testing and Performance Characterization of the High Efficiency Dehumidification System (HEDS) Technology

The high efficiency dehumidification system (HEDS) is a unique air handling unit (AHU) design with two water coils. Connected in series, these water coils can sensibly reheat the airstream after it is cooled and dehumidified, thereby mitigating (or sometimes eliminating) the need for conventional sensible reheat with additional energy from hot water, electric resistance or steam coils. Another unique design feature is the size of the HEDS primary cooling coil. While typical AHU cooling coils have a 6-row geometry, the HED's cooling coil has a deeper 10-row geometry enabling discharge air dew point temperatures at or below 55 degrees F despite warmer chilled water supply temperatures approaching (sometimes exceeding) 50 degrees F. The ability to meet acceptable discharge air dew points with warmer chilled water supply temperatures improves both operational efficiency and system resilience against chilled water plant operational or control issues. This report summarizes the 59 steady-state test results that form a comprehensive performance map of the HEDS technology including its reheat capability. The breadth of outdoor air conditions and flow rates over which the HEDS technology was tested and characterized encompasses the unit 1) operating as a dedicated outdoor air system or mixed air system and 2) controlled with constant air volume or variable air volume fan control.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

DISCOVR strain pipeline screening – Part II: Winter and summer season areal productivities and biomass compositional shifts in climate-simulation photobioreactor cultures

Assessing the seasonal biomass productivity and compositional shift dynamics under simulated outdoor culture conditions of the top 22 algae strains selected during Tier I flask screening is an important step in the further prioritization of strains with regard to outdoor pond cultivation. These top 22 strains were subjected to Tier II testing in the PNNL Laboratory Environmental Algae Pond Simulator (LEAPS) photobioreactors, simulating light and temperature conditions of 20 cm deep outdoor ponds during the Arizona winter and summer season. All strains were grown in two consecutive nutrient-replete batch culture experiments at their particular optimal medium salinity to quantify their respective seasonal linear-phase areal biomass productivities. To determine biomass compositional shifts in response to nutrient-depletion, the LEAPS cultures were allowed to enter a 9-day nutrient depletion phase at the end of the second batch run. The following strains were evaluated in winter-season climate-simulated cultures and are listed in the order from highest (7.9 g m -2 day -1 ) to lowest (2.3 g m -2 day -1 ) areal N-replete biomass productivity: Monoraphidium minutum 26B-AM, Tetraselmis striata LANL1001, Chlorella vulgaris LRB AZ-1201, Micractinium reisseri NREL14-F2, Monoraphidium sp. MONOR1, Chlorella vulgaris NREL4-C12, Scenedesmus obliquus UTEX393, Scenedesmus acutus LRB-AP-0401, Nannochloropsis oceanica CCAP849/10, and Stichococcus minutus CCALA727. The following strains were evaluated in summer-season climate-simulated cultures and are listed in the order from highest (31.8 g m -2 day -1 ) to lowest (14.2 g m -2 day -1 ) areal N-replete biomass productivity: Picochlorum renovo NREL39-A8, Scenedesmus obliquus UTEX393, Porphyridium cruentum CCMP675, Picochlorum celeri TG2-WT-CSM/EMRE, Chlorella sorokiniana DOE1116, Stichococcus minor CCMP819, Picochlorum oklahomensis CCMP2329, Chlorella sorokiniana DOE1412 (UTEXB3016), Scenedesmus rubescens NREL46B-D3, Picochlorum soloecismus DOE101, Tetraselmis striata LANL1001, Scenedesmus obliquus DOE 0152.z, and Agmenellum quadruplicatum UTEX2268. All LEAPS cultures experienced a significant reduction in areal biomass productivity in response to nutrient-depletion, from 7-16% in the winter season simulation and up to 1-60% in the summer season simulation. Finally, for 10 of the strains tested, the carbohydrate content more than doubled upon nutrient depletion, and for 9 strains, the lipid content increased by over 50% of the initial content.

09 BIOMASS FUELS↗

Field-Aging Test Bed for Behind-the-Meter PV + Energy Storage

Small DC-coupled battery test systems are deployed at the National Renewable Energy Laboratory to evaluate capacity fade models and report on performance parameters such as round-trip efficiency under indoor and outdoor deployment scenarios. Initial commercial battery products include LG Chem RESU lithium-ion (Li-ion) and Avalon vanadium redox flow batteries. Adapting indoor lab-scale test methods to outdoor systems has challenges, including maintaining constant temperature and fully controlling batteries through standard discharge curves. Initial measurements show the Li-ion battery systems performing within expectations, near 85% round-trip efficiency. Initial lifetime modeling and measurements indicate that battery capacity could degrade by 20%-35% over 10 years at current rates.

14 SOLAR ENERGY↗

Performance and loads data from a hover test of a full-scale XV-15 rotor

A hover test of a full-scale XV-15 rotor was conducted at the Outdoor Aerodynamic Research Facility at Ames Research Center. The primary objective of the test was to obtain accurate measurements of the hover performance of the original, metal-blade XV-15 rotor system. Data were acquired for rotor tip Mach numbers ranging from 0.60 to 0.73. This report presents data on rotor performance, rotor wake downwash velocities, and rotor loads.

Felker, F. F.↗

Remote sensing as a source of data for outdoor recreation planning

Specific data needs for outdoor recreation planning and the ability of tested remote sensors to provide sources for these data are examined. Data needs, remote sensor capabilities, availability of imagery, and advantages and problems of incorporating remote sensing data sources into ongoing planning data collection programs are discussed in detail. Examples of the use of imagery to derive data for a range of common planning analyses are provided. A selected bibliography indicates specific uses of data in planning, basic background materials on remote sensing technology, and sources of information on environmental information systems expected to use remote sensing to provide new environmental data of use in outdoor recreation planning.

Reed, W. E.↗

Development of a forced advection sampling technique (FAST) for quantification of methane emissions from orphaned wells

Abstract. Orphaned wells, meaning unplugged and non-producing wells lacking responsible owners, pose a significant and undersampled environmental challenge due to their vast number and unknown associated emissions. We propose, develop and test an alternative method for estimating emissions from orphaned wells using a forced advection sampling technique (FAST) that can overcome many of the limitations in current methods (cost, accuracy, safety). In contrast to existing ambient Gaussian plume methods, our approach uses a fan-generated flow to force advection between the emission source and a point methane (CH4) sensor. The fan flow field is characterized using a colocated sonic anemometer to measure the 3D wind profile generated by the fan. Using time-series measurements of CH4 concentration and wind, a simple estimate of the CH4 emission rate of the source can be inferred. The method was calibrated using outdoor controlled-release experiments and then tested on four orphaned wells in Lufkin, TX, and Osage County, OK. Our results suggest that the FAST method can provide a low-cost, portable, fast and safe alternative to existing methods with reasonable estimates of orphaned well emissions over a range of leak rates below 40 g h−1 and within certain geometric and atmospheric constraints.

Dubey, Mohit L↗

Efficiency tests of samplers for microbiological aerosols, a review

To obtain comparable results from studies using a variety of samplers of microbiological aerosols with different collection performances for various particle sizes, methods reported in the literature were surveyed, evaluated, and tabulated for testing the efficiency of the samplers. It is concluded that these samplers were not thoroughly tested, using reliable methods. Tests were conducted in static air chambers and in various outdoor and work environments. Results are not reliable as it is difficult to achieve stable and reproducible conditions in these test systems. Testing in a wind tunnel is recommended.

Henningson, E.↗

Baseline performance of solar collectors for NASA Langley solar building test facility

The solar collector field contains seven collector designs. Before operation in the field, the experimental performances (thermal efficiencies) of the seven collector designs were measured in an indoor solar simulator. The resulting data provided a baseline for later comparison with actual field test data. The simulator test results are presented for the collectors as received, and after several weeks of outdoor exposure with no coolant (dry operation). Six of the seven collector designs tested showed substantial reductions in thermal efficiency after dry operation.

Knoll, R. H.↗

High‑performance cold‑climate heat pump using tandem compressors with and without vapor injection: Laboratory investigation and field demonstration

Cold‑climate air‑source heat pumps must maintain heating capacity and stable operation at low ambient temperatures for residential applications. This study adapts tandem single-speed compressors—proven in commercial systems —for residential CCHPs, integrating VI and validating performance across laboratory and extreme field conditions to achieve cold-climate targets. That is to achieve ≥75% of the rated heating capacity at −25.0 °C relative to 8.3 °C and heating coefficient of performance (COP) greater than 4.0 at 8.3 °C. Laboratory testing confirmed that both configurations met these targets while operating within acceptable discharge‑temperature limits. Relative to the non‑VI configuration, the VI system provided up to 15% higher heating capacity and up to 9% higher heating COP under identical conditions, yielding a 5.6–9.1% increase in heating seasonal performance factor (HSPF). Field tests in Ohio and Alaska, with minimum outdoor temperatures of −25.0 °C and −34.0 °C, respectively, showed stable operation, minimal supplemental heating (<3.2%), low defrost penalties, and consistent output. Tandem‑compressor architectures proves promising for cold-climate residential heating.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

The effects of outdoor air-side fouling on frost growth and heat transfer characteristics of a microchannel heat exchanger: An experimental study

Air source heat pumps have the potential to efficiently heat and cool buildings, but their effectiveness in many climates is limited by frost growth on the outdoor heat exchanger in heating mode. These heat exchanger coils are also subject to fouling from fibers and particulates outdoors. Frost and fouling have each independently been studied extensively, and newly available research on fouling provides a method to realistically foul the air-side of coils in the laboratory. The current paper uses this method to conduct the first laboratory study of the important interactions between fouling and frost growth for a heat pump outdoor coil. A microchannel heat exchanger is tested clean and fouled, with variations in fouling level, humidity, and initial face velocity of air. Air flow rate is allowed to vary with resistance, and a surprising result is that light fouling increases heat transfer and frost growth rates, even with a 3.5% reduction in initial airflow caused by the fouling. However, heavier fouling decreases both rates. When frost growth is normalized to heat transfer, it is found to be increased by fouling; i.e. the coil’s sensible heat ratio decreases.

42 ENGINEERING↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 1: Particulate and gaseous emissions

This study investigated how heat demand and fuel loading affect the emissions from outdoor wood-fired hydronic heaters by testing two such appliances using an integrated-duty cycle test method. This test included transient operating conditions, such as cold and hot-starts and modulation between 15 and 100% of maximum rated output. Emission values indicate transient operating conditions produce higher emissions than steady state operation. Cold starts resulted in elevated particulate matter emission factors for both appliances; in one case the particulate matter emission factor for this period was >3500 mg/MJ, which represented emissions 20 times the average value. Additionally, when heat demand was cycled—elevated CO emission factors were measured, with values >5000 mg/MJ for both appliances and more than 3 times the appliance averages, respectively. It follows that the appliance average particulate matter emission factors and CO emission factors were not representative of the actual EF values during these transient periods. In contrast, methane emission factors were relatively stable throughout all tested combustion conditions; however, they were much higher than oil-fired appliances are therefore should not be ignored. These findings demonstrate that wood-fired hydronic heater emissions during transient operating conditions can be significantly greater than emissions during steady-state test conditions, such as those used in typical certification tests. Consequently, certification test values for particulate matter and CO emission factors may significantly underestimate the actual emissions of these appliances when operated in a home. Use of integrated duty-cycle test protocols that capture cold-starts and reloading are better for representing in-use operations of wood-fired hydronic heaters and provide more realistic emissions and delivered efficiency measurements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

JT15D simulated flight data evaluation

The noise characteristics of the JT15D turbofan engine was analyzed with the objectives of: (1) assessing the state-of-art ability to simulate flight acoustic data using test results acquired in wind tunnel and outdoor (turbulence controlled) environments; and (2) predicting the farfield noise directivity of the blade passage frequency (BPF) tonal components using results from rotor blade mounted dynamic pressure instrumentation. Engine rotor tip speeds at subsonic, transonic, and supersonic conditions were evaluated. The ability to simulate flight results was generally within 2-3 dB for both outdoor and wind tunnel acoustic results. Some differences did occur in the broadband noise level and in the multiple-pure-tone harmonics at supersonic tip speeds. The prediction of blade passage frequency tone directivity from dynamic pressure measurements was accomplished for the three tip speed conditions. Predictions were made of the random and periodic components of the tone directivity. The technique for estimating the random tone component used hot wire data to establish a correlation between dynamic pressure and turbulence intensity. This prediction overestimated the tone level by typically 10 dB with the greatest overestimates occurring at supersonic conditions.

Holm, R. G.↗

Automated sUAS Inspection Capability for NASA’s Mission Critical Testing Facilities

The wind tunnels at Ames are crucial to NASA and industry but pose unique inspection challenges. Current inspection processes are highly manual, and as such are labor and schedule intensive. These needs can be better met with emerging technology such as sUAS (drones), computer vision, and machine learning. This work seeks to bring the drone based inspection workflow into production-ready status and integrate into existing facility inspections. This includes operation of a drone platform, establishing a photogrammetry pipeline, development of procedures and streamlining flight approval processes, and establishing a base of experience at Ames for this work. We have worked with the NFAC, unitary, and Arcjet facilities to identify use cases and have performed test flights at Ames (both indoors and outdoors). The system is being readied for incorporation into routine inspection operations.

David Daisuke Murakami↗

Suitable low Global Warming Potential (GWP) refrigerants for two-speed Heat Pumps for residential applications based on speed Heat Pumps for residential applications based on simulated performance simulated performance

Cold climate Heat Pumps (CCHPs) using single-speed compressors in tandem have been successfully built and tested to reach its performance metrics with outdoor temperatures as low as -25°C. CCHPs must be designed to alleviate the problems of too high discharge temperatures, low suction pressure and high-pressure ratio at low ambient conditions and insufficient heating capacity relative to the heating capacity at 8.3°C. In this paper we recognize those concerns. Low-GWP refrigerants are screened based on the shape of their T-S saturation boundary. Simulations of the performance of low-GWP refrigerants (R32, R454B, R466A, and R452B) relative to R410A is done using the DOE/ORNL Heat Pump Design Model at the component level. Systemic inefficiency, the root cause of lost work, is addressed by component-level exergy analysis to refine design options. CCHPs using low-GWP refrigerants addresses issues of reducing energy consumption, lowering carbon footprint, and enabling environmentally sustainability. The CCHP was designed to meet a HSPF > 11.0 and SEER > 15.0 having adequate heat pump heating capacity down to -25°C. It is estimated that at least 2.6 million U.S homes using electric furnaces and heat pumps in cold or very old climates with an annual energy consumption of 0.17EJ would benefit by CCHPs.

Ally, Moonis↗

Characterizing photovoltaic backsheet adhesion degradation using the wedge and single cantilever beam tests, Part I: Field Modules

Photovoltaic backsheets are exposed to harsh outdoor weathering conditions throughout their service lives that can compromise their protective function, through adhesive debonding between their constituent layers and between the backsheet and the module. We report a large-scale study on adhesive degradation was conducted on 37 field-exposed modules, that spanned 19 different module manufacturers, that were deployed among six Köppen–Geiger climatic zones, and that were fielded between 0 and 28 years. Six outer layer polymer classes were identified among the backsheets: polyamide (PA), polyethylene terephthalate (PET), polyvinyl fluoride (PVF), polyvinylidene fluoride (PVDF), fluoroethylene vinyl ether copolymer (FEVE), and tetrafluoroethylene hexafluoropropylene vinylidene fluoride copolymer (THV). Two adhesion tests were used to measure the adhesive strength: the wedge test and the width-tapered single-cantilever beam (SCB) test. Adhesion energies were compared across exposure time and Köppen–Geiger climatic zone. Many of the PET-, PVF-, and PVDF-based backsheets experienced degradation of the adhesive layer between the backsheet outer and core layers. A consistent trend of decreasing adhesion energy with exposure time was observed in five out of the six backsheet types. Trends among adhesion energy and climatic zone, while expected, were not observed, possibly due to broad ranges in temperature, humidity, and precipitation defining Köppen–Geiger climatic zones. The cantilever beam measurements produced an upper cutoff of approximately 100 J/m 2 , above which no modules exhibited field delamination. The results are part of a two-part study quantifying adhesion in both field-weathered and indoor-exposed PV backsheets.

14 SOLAR ENERGY↗

Performance and loads data from a hover test of a full-scale advanced technology XV-15 rotor

A hover test of a full-scale, composite, advanced technology XV-15 rotor was conducted at the Outdoor Aerodynamic Research Facility at Ames Research Center. The primary objective of the test was to obtain accurate measurements of the hover performance of this rotor system. Data were acquired for rotor tip Mach numbers ranging from 0.35 to 0.73. The rotor was tested with several alternate blade root and blade-tip configurations. Data are presented on rotor performance, rotor-wake downwash velocities, and rotor system loads.

Felker, Fort F.↗