Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical telescopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Astrometric Telescope Facility isolation and pointing study

The Astrometric Telescope Facility (ATF), an optical telescope designed to detect extrasolar planetary systems, is scheduled to be a major user of the Space Station's Payload Pointing System (PPS). However, because the ATF has such a stringent pointing stability specification and requires + or - 180 deg roll about its line of sight, mechanisms to enhance the basic PPS capability are required. The ATF pointing performance achievable by the addition of a magnetic isolation and pointing system (MIPS) between the PPS upper gimbal and the ATF, and separately, by the addition of a passive isolation system between the Space Station and the PPS base was investigated. The candidate MIPS can meet the ATF requirements in the presence of a 0.01 g disturbance. It fits within the available annular region between the PPS and the ATF while meeting power and weight limitations and providing the required roll motion, payload data and power services. By contrast, the passive base isolator system must have an unrealistically low isolation bandwidth on all axes to meet ATF pointing requirements and does not provide roll about the line of sight.

Hibble, William↗

Swift and GRB's: Unveiling the Relativistic Universe

We report Swift observations of GRB 051109A, a bright, long burst detected with BAT. A bright afterglow was quickly detected with the X-Ray Telescope and Ultraviolet and Optical Telescope, and observations continued for more than 10 days. The X-ray light is complex with a rapid initial decay followed by a more gradual decay. There is evidence for a jet break with an indicated opening angle of a few degrees. UVOT observations with the V filter are consistent with a power-law day for the first 10 ks. We discuss the observations in light of current models.

Marshall, Francis E.↗

Thermal design trades for SAFIR architecture concepts

SAFIR is a IO-meter, 4 K space telescope optimized for wavelengths between 20 microns and 1 mm. The combination of aperture diameter and telescope temperature will provide a raw sensitivity improvement of more than a factor of 1000 over presently-planned missions. The sensitivity will be comparable to that of the JWST and ALMA, but at the critical far-IR wavelengths where much of the universe's radiative energy has emerged since the origin of stars and galaxies. We examine several of the critical technologies for SAFIR which enable the large cold aperture, and present results of studies examining the telescope optics and the spacecraft thermal architecture. Both the method by which the aperture is filled, and the overall optical design for the telescope can impact the potential scientific return of SAFIR. Thermal architecture that goes far beyond the sunshades developed for the James Webb Space Telescope will be necessary to achieve the desired sensitivity of SAFIR. By combining active and passive cooling at critical points within the observatory, a significant reduction of the required level of active cooling can be obtained.

infrared telescopes↗

Hinode Observations of the Onset Stage of a Solar Filament Eruption

We use Hinode X-Ray Telescope (XRT) and Solar Optical Telescope (SOT) filtergraph (FG) Stokes-V magnetogram observations, to study the early onset of a solar eruption that includes an erupting filament that we observe in TRACE EUV images. The filament undergoes a slow rise for about 20 min prior to its fast eruption and strong soft X-ray flaring, and the new Hinode data elucidate the physical processes occurring during the slow-rise period. Magnetic flux cancellation occurs along the neutral line of the filament, beginning several hours before eruption. During the slow-rise phase, a soft X-ray (SXR) sigmoid forms from apparent reconnection low in the sheared core field traced by the filament, and there is a low-level intensity peak in both EUV and SXRs at the start of the slow rise.

Sterling, Alphonse C.↗

Early Hinode Observations of a Solar Filament Eruption

We use Hinode X-Ray Telescope (XRT) and Solar Optical Telescope (SOT) filtergraph (FG) Stokes-V magnetogram observations to study the early onset of a solar eruption that includes an erupting filament that we observe in TRACE EUV images; this is one of the first filament eruptions seen with Hinode. The filament undergoes a slow rise for at least 30 min prior to its fast eruption and strong soft X-ray flaring, and the new Hinode data elucidate the physical processes occurring during the slow-rise period: During the slow-rise phase, a soft X-ray (SXR) sigmoid forms from apparent reconnection low in the sheared core field traced by the filament, and there is a low-level intensity peak in both EUV and SXRs during the slow rise. The SOT data show that magnetic flux cancellation occurs along the neutral line of the filament in the hours before eruption, and this likely caused the low-lying reconnection that produced the microflaring and the slow rise leading up to the eruption.

Sterling, Alphonse C.↗

Hinode Observations of the Onset Stage of a Solar Filament Eruption

We used Hinode X-Ray Telescope (XRT) and Solar Optical Telescope (SOT) filtergraph (FG) Stokes-V magnetogram observations, to study the early onset of a solar eruption that includes an erupting filament that we observe in TRACE EUV images. The filament undergoes a slow rise for at least 20min prior to its fast eruption and strong soft X-ray (SXR) flaring; such slow rises have been previously reported, and the new Hinode data elucidate the physical processes occurring during this period. XRT images show that during the slow-rise phase, an SXR sigmoid forms from apparent reconnection low in the sheared core field traced by the filament, and there is a low-level intensity peak in both EUV and SXRs during the slow rise. MDI and SOT FG Stokes-V magnetograms show that the pre-emption filament is along a neutral line between opposing-polarity enhanced network cells, and the SOT magnetograms show that these opposing fields are flowing together and canceling for at least six hours prior to eruption. From the MDI data we measured the canceling network fields to be approx. 40 G, and we estimated that approx. 10(exp 19)Mx of flux canceled during the five hours prior to eruption; this is only approx.5% of the total flux spanned by the eruption and flare, but apparently its tether-cutting cancellation was enough to destabilize the sigmoid field holding the filament and resulted in that field's eruption.

Sterling, Alphonse C.↗

Hinode Observations of the Onset Stage of a Solar Filament Eruption

We use Hinode X-Ray Telescope (XRT) and Solar Optical Telescope (SOT) filtergraph (FG) Stokes-V magnetogram observations, to study the early onset of a solar eruption that includes an erupting filament that we observe in TRACE EUV images. The filament undergoes a slow rise for at least 20 min prior to its fast eruption and strong soft X-ray flaring; such slow rises have been previously reported, and the new Hinode data elucidate the physical processes occurring during this period. XRT images show that during the slow-rise phase, a soft X-ray (SXR) sigmoid forms from apparent reconnection low in the sheared core field traced by the filament, and there is a low-level intensity peak in both EUV and SXRs during the slow rise. MDI and SOT FG/V magnetograms show that the pre-eruption filament is along a neutral line between opposing-polarity enhanced network cells, and the SOT magnetograms show that these opposing fields are flowing together and canceling for at least six hours prior to eruption. From the MDI data we measure the canceling network fields to be approx. 40 G, and we estimate that approx. 10(exp 19) Mx of flux canceled during the five hours prior to eruption; this is only approx. 5% of the total flux spanned by the eruption and flare, but apparently its tether-cutting cancellation was enough to destabilize the sigmoid field holding the filament and resulted in that field's eruption.

Sterling, Alphonse C.↗

Cryogenic Thermal Distortion Model Validation for the JWST ISIM Structure

The James Webb Space Telescope (JWST) is a large, infrared-optimized space telescope consisting of an Optical telescope element (OTE), Integrated science instrument module (ISIM), a Spacecraft, and a Sunshield. The Integrated Science Instrument Module (ISIM) consists of the JWST science instruments (NIRCam, MIRI, NIRSpec), a fine guidance sensor (FGS), the ISIM Structure, and thermal and electrical subsystems. JWST's instruments are designed to work primarily in the infrared range of the electromagnetic spectrum, and the instruments and telescope operate at cryogenic temperatures (approximately 35 K for the instruments).

Johnston, John↗

Three-Axis Attitude Estimation With a High-Bandwidth Angular Rate Sensor

A continuing challenge for modern instrument pointing control systems is to meet the increasingly stringent pointing performance requirements imposed by emerging advanced scientific, defense, and civilian payloads. Instruments such as adaptive optics telescopes, space interferometers, and optical communications make unprecedented demands on precision pointing capabilities. A cost-effective method was developed for increasing the pointing performance for this class of NASA applications. The solution was to develop an attitude estimator that fuses star tracker and gyro measurements with a high-bandwidth angular rotation sensor (ARS). An ARS is a rate sensor whose bandwidth extends well beyond that of the gyro, typically up to 1,000 Hz or higher. The most promising ARS sensor technology is based on a magnetohydrodynamic concept, and has recently become available commercially. The key idea is that the sensor fusion of the star tracker, gyro, and ARS provides a high-bandwidth attitude estimate suitable for supporting pointing control with a fast-steering mirror or other type of tip/tilt correction for increased performance. The ARS is relatively inexpensive and can be bolted directly next to the gyro and star tracker on the spacecraft bus. The high-bandwidth attitude estimator fuses an ARS sensor with a standard three-axis suite comprised of a gyro and star tracker. The estimation architecture is based on a dual-complementary filter (DCF) structure. The DCF takes a frequency- weighted combination of the sensors such that each sensor is most heavily weighted in a frequency region where it has the lowest noise. An important property of the DCF is that it avoids the need to model disturbance torques in the filter mechanization. This is important because the disturbance torques are generally not known in applications. This property represents an advantage over the prior art because it overcomes a weakness of the Kalman filter that arises when fusing more than one rate measurement. An additional advantage over prior art is that, computationally, the DCF requires significantly fewer real-time calculations than a Kalman filter formulation. There are essentially two reasons for this: the DCF state is not augmented with angular rate, and measurement updates occur at the slower gyro rate instead of the faster ARS sampling rate. Finally, the DCF has a simple and compelling architecture. The DCF is exactly equivalent to flying two identical attitude observers, one at low rate and one at high rate. These attitude observers are exactly of the form currently flown on typical three-axis spacecraft.

Bayard, David S.↗

Stray Light Modeling of the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM)

This paper describes an integrated stray light model of each Science Instrument (SI) in the Integrated Science Instrument Module (ISIM) of the James Webb Space Telescope (JWST) and the Optical Telescope Element Simulator (OSIM), the light source used to characterize the performance of ISIM in cryogenic-vacuum tests at the Goddard Space Flight Center (GSFC). We present three cases where this stray light model was integral to solving questions that arose during the testing campaign - 1) ghosting and coherent diffraction from hardware surfaces in the Near Infrared Imager and Slitless Spectrograph (NIRISS) GR700XD grism mode, 2) ghost spots in the Near Infrared Camera (NIRCam) GRISM modes, and 3) scattering from knife edges of the NIRCam focal plane array masks.

stray light modeling↗

Monitoring and Detecting X-ray Transients with the Swift Observatory

Swift is a multi-wavelength observatory specifically designed to detect transients sources in the gamma-ray energy band 15-200 keV. The primary goals of the mission involve gamma ray burst (GRB) astronomy, namely to determine the origin of GRBs and their afterglows, and use bursts to probe the early Universe. However, Swift will also discover new X-ray transient sources, and it will be possible to bring Swift's considerable multi-wavelength capabilities to bear on these sources, and those discovered by other means. The Burst Alert Telescope (BAT) is a coded mask instrument sensitive to 15-200 keV gamma rays, and has a field of view which covers approximately 1/8th of the sky in a single pointing. Over a typical observing day, the almost the entire sky will be observed and monitored for new transient sources. Sources will be detected within several hours of observation. The two narrow field instruments, the X-ray Telescope and Ultra-Violet Optical Telescope, can provide sensitive simultaneous imaging and spectroscopy observations in the optical through soft X-ray bands. The Swift science operations team will entertain requests for targets of opportunity for sources which are astrophysically significant. Swift will be ideally suited for the detection of transients which produce hard X-rays, such as black hole binaries and some neutron star systems.

Markwardt, Craig↗

Wavefront Sensing of X-Ray Telescopes

Phase Retrieval analysis of off-axis or defocused focal-plane data from telescope optics has been proven effective in understanding misalignments and optical aberrations in normal incidence telescopes. The approach is used, e.g., in commissioning of the James Webb Space Telescope (JWST) segmented primary mirror. There is a similar need for evaluating low-order figure errors of grazing incidence mirrors and nested telescope assemblies. When implemented in these systems, phase retrieval does not depend on normal incidence access to each mirror (shell) surface and, therefore, provides an effective means for evaluating nested x-ray telescopes during integration and test. We have applied a well-known phase retrieval algorithm to grazing incidence telescopes. The algorithm uses the Levenberg-Marquardt optimization procedure to perform a non-linear least-squares fit of the telescope Point Spread Function (PSF). The algorithm can also retrieve low order figure errors at visible wavelengths where optical diffraction is the dominant defect in the PSF. In this paper we will present the analytical approach and its implementation for grazing incidence mirrors of the International X-Ray Observatory (IXO). We analyze the effects of low order axial surface errors individually, and in combination on the system PSF at 633 nanometers. We demonstrate via modeling that the wavefront sensing algorithm can recover axial errors (of the grazing incidence mirrors) to a small fraction of the known axial figure errors using simulated PSFs as input data to the algorithm.

Saha, Timo↗

The rapidly moving telescope - A progress report

A ground-based optical telescope system has been constructed with the capability to locate fast optical transients that may be associated with gamma-ray bursts (GRBs). The instrument has been integrated and operated during a shakedown period at GSFC, Maryland. Results of 35 hours of 'state mode' data are presented. The telescope has the proven capability to slew to any point on the night sky within 1.0 sec, track that position with better than one arcsecond stability, and image a 9 x 12 arcmin field of view with 1 arcsec angular resolution with 1.5 sec time resolution. The telescope-CCD camera system has a sensitivity of 13th magnitude for transients and 14th mag for field stars. In the 35 hr of operation many single frame transients of instrumental and optical origin have been observed; no two-sequential frame astrophysical transients have been identified. The combined rate of instrumental transients (predominantly sea-level muons) is 7.2/hr and of optical transients (satellite glints, airplane strobe lights, and meteors) is 5.1/hr. The RMT will operate in conjunction with the MIT Explosive Transient Camera survey instrument at Kitt Peak National Observatory, Tucson. The RMT is now being installed at Kitt Peak. Full operation will begin this summer.

Barthelmy, S. D.↗

On-Orbit Multi-Field Wavefront Control with a Kalman Filter

A document describes a multi-field wavefront control (WFC) procedure for the James Webb Space Telescope (JWST) on-orbit optical telescope element (OTE) fine-phasing using wavefront measurements at the NIRCam pupil. The control is applied to JWST primary mirror (PM) segments and secondary mirror (SM) simultaneously with a carefully selected ordering. Through computer simulations, the multi-field WFC procedure shows that it can reduce the initial system wavefront error (WFE), as caused by random initial system misalignments within the JWST fine-phasing error budget, from a few dozen micrometers to below 50 nm across the entire NIRCam Field of View, and the WFC procedure is also computationally stable as the Monte-Carlo simulations indicate. With the incorporation of a Kalman Filter (KF) as an optical state estimator into the WFC process, the robustness of the JWST OTE alignment process can be further improved. In the presence of some large optical misalignments, the Kalman state estimator can provide a reasonable estimate of the optical state, especially for those degrees of freedom that have a significant impact on the system WFE. The state estimate allows for a few corrections to the optical state to push the system towards its nominal state, and the result is that a large part of the WFE can be eliminated in this step. When the multi-field WFC procedure is applied after Kalman state estimate and correction, the stability of fine-phasing control is much more certain. Kalman Filter has been successfully applied to diverse applications as a robust and optimal state estimator. In the context of space-based optical system alignment based on wavefront measurements, a KF state estimator can combine all available wavefront measurements, past and present, as well as measurement and actuation error statistics to generate a Maximum-Likelihood optimal state estimator. The strength and flexibility of the KF algorithm make it attractive for use in real-time optical system alignment when WFC alone cannot effectively align the system.

Lou, John↗