Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Development of Flight Slit-Jaw Optics for Chromospheric Lyman-Alpha SpectroPolarimeter

In sounding rocket experiment CLASP, I have placed a slit a mirror-finished around the focal point of the telescope. The light reflected by the mirror surface surrounding the slit is then imaged in Slit-jaw optical system, to obtain the a-ray Lyman secondary image. This image, not only to use the real-time image in rocket flight rocket oriented direction selection, and also used as a scientific data showing the spatial structure of the Lyman alpha emission line intensity distribution and solar chromosphere around the observation area of the polarimetric spectroscope. Slit-jaw optical system is a two off-axis mirror unit part including a parabolic mirror and folding mirror, Lyman alpha transmission filter, the optical system magnification 1x consisting camera. The camera is supplied from the United States, and the other was carried out fabrication and testing in all the Japanese side. Slit-jaw optical system, it is difficult to access the structure, it is necessary to install the low place clearance. Therefore, influence the optical performance, the fine adjustment is necessary optical elements are collectively in the form of the mirror unit. On the other hand, due to the alignment of the solar sensor in the US launch site, must be removed once the Lyman alpha transmission filter holder including a filter has a different part from the mirror unit. In order to make the structure simple, stray light measures Aru to concentrate around Lyman alpha transmission filter. To overcome the difficulties of performing optical alignment in Lyman alpha wavelength absorbed by the atmosphere, it was planned 'following four steps in order to reduce standing time alignment me. 1. is measured in advance refractive index at Lyman alpha wavelength of Lyman alpha transmission filter (121.567nm), to prepare a visible light Firuwo having the same optical path length in the visible light (630nm).2. The mirror structure CLASP before mounting unit standing, dummy slit and camera standing prescribed position in leading frame is, to complete the internal alignment adjustment. 3. CLASP structure F mirror unit and by attaching the visible light filter, as will plague the focus is carried out in standing position adjustment visible flight products camera. 4. Replace the Lyman alpha transmission filter, it is confirmed by Lyman alpha wavelength (under vacuum) the requested optical performance have come. Currently, up to 3 of the steps completed, it was confirmed in the visible light optical performance that satisfies the required value sufficiently extended. Also, put in Slit-jaw optical system the sunlight through the telescope of CLASP, it is also confirmed that and that stray light rejection no vignetting is in the field of view meets request standing.

chromospheric↗

Origin of the framing camera.

Framing cameras of rotating mirror type, discussing optical principles used in American, British and Russian high speed cameras developed since original NACA camera

FRAMING CAMERA↗

Origin of the framing camera.

Framing cameras of rotating mirror type, discussing optical principles used in American, British and Russian high speed cameras developed since original NACA camera

HIGH SPEED CAMERA↗

Imaging of Venus from Galileo - Early results and camera performance

Three images of Venus have been returned so far by the Galileo spacecraft following an encounter with the planet on UT February 10, 1990. The images, taken at effective wavelengths of 4200 and 9900 A, characterize the global motions and distribution of haze near the Venus cloud tops and, at the latter wavelength, deep within the main cloud. Previously undetected markings are clearly seen in the near-infrared image. The global distribution of these features, which have maximum contrasts of 3 percent, is different from that recorded at short wavelengths. In particular, the 'polar collar', which is omnipresent in short wavelength images, is absent at 9900 A. The maximum contrast in the features at 4200 A is about 20 percent. The optical performance of the camera is described and is judged to be nominal.

Belton, M. J. S.↗

Design and evaluation of controls for drift, video gain, and color balance in spaceborne facsimile cameras

The facsimile camera is an optical-mechanical scanning device which has become an attractive candidate as an imaging system for planetary landers and rovers. This paper presents electronic techniques which permit the acquisition and reconstruction of high quality images with this device, even under varying lighting conditions. These techniques include a control for low frequency noise and drift, an automatic gain control, a pulse-duration light modulation scheme, and a relative spectral gain control. Taken together, these techniques allow the reconstruction of radiometrically accurate and properly balanced color images from facsimile camera video data. These techniques have been incorporated into a facsimile camera and reproduction system, and experimental results are presented for each technique and for the complete system.

Katzberg, S. J.↗

A Program to Detect and Characterize Extra-Solar Giant Planets

We initiated a significant hardware upgrade to the AFOE, to increase its efficiency for precise radial velocity studies to the level where we can continue to contribute usefully to extrasolar planet research on relatively bright stars. The AFOE, at a 1.5-m telescope, will of course not have the sensitivity of radial velocity instruments at larger telescopes, such as the HIRES on Keck or the Hectochelle on the MMT telescope (about to come on line). However, it has been possible to increase its efficiency for precise radial velocity studies by a factor of 4 to 5, which-combined with the large amount of telescope time available at the 1.5-m telescope-will permit us to do intensive follow-up observations of stars brighter than about 8 magnitude. The AFOE was originally designed primarily for asteroseismology using a ThAr reference. This provided useful wavelength stability over tens of minutes as required for asteroseismology, but we were unable to get a long-term (month-to-month) velocity precision better than about 15 m/s with that setup. Hence, we implemented an iodine cell as a wavelength reference for extrasolar planet studies. However, the optical design of the original AFOE did not completely span the wavelength range covered by the iodine absorption spectrum, and furthermore the optics suffered significant light loss through optical obscuration in the camera secondary. To remedy this, we replaced the AFOE grating with a new one that covered the entire iodine spectral range at somewhat lower spectral resolution, and replaced the camera with a transmitting lens. (The use of a lens was made possible by restricting the spectral range covered by the upgraded AFOE to only the iodine region.) These upgrades were successfully completed, and the instrument was tested for three nights in fall of 2002. The expected improvement in sensitivity by a factor of 4 to 5 was observed: that is, the same velocity precision as previously attained (of order 5 to 7 m/s) was now obtained on a stars that are about 4 to 5 times fainter. Unfortunately, just after installing the new AFOE optics, there was a catastrophic failure of the old Tektronix CCD. A careful investigation was made, and it was determined that the failure was probably due to too many thermal cyclings over the previous 8 years. The only solution was to purchase a new CCD. Internal funds of $16,000 were found for this purpose, and the new CCD (a thinned, back-illuminated Marconi 2K x 2K device with 13.5 micron pixels, and employing dual readout channels to keep the readout time as short as 20 seconds) was ordered, has now arrived, and is currently under test before 1 being installed in the AFOE liquid nitrogen dewar. At the same time, we expect to implement new CCD control electronics. This system should be better in many ways than the previous detector (including eliminating the need for UV flashing to maximize the quantum efficiency). We plan to install the detector on the telescope and begin operations again in April of this year.

Lindstrom, David↗

Diurnal variations in optical depth at Mars: Observations and interpretations

Viking lander camera images of the Sun were used to compute atmospheric optical depth at two sites over a period of 1 to 1/3 martian years. The complete set of 1044 optical depth determinations is presented in graphical and tabular form. Error estimates are presented in detail. Optical depths in the morning (AM) are generally larger than in the afternoon (PM). The AM-PM differences are ascribed to condensation of water vapor into atmospheric ice aerosols at night and their evaporation in midday. A smoothed time series of these differences shows several seasonal peaks. These are simulated using a one-dimensional radiative convective model which predicts martial atmospheric temperature profiles. A calculation combining these profiles with water vapor measurements from the Mars Atmospheric Water Detector is used to predict when the diurnal variations of water condensation should occur. The model reproduces a majority of the observed peaks and shows the factors influencing the process. Diurnal variation of condensation is shown to peak when the latitude and season combine to warm the atmosphere to the optimum temperature, cool enough to condense vapor at night and warm enough to cause evaporation at midday.

Colburn, D. S.↗

Video Mosaicking for Inspection of Gas Pipelines

A vision system that includes a specially designed video camera and an image-data-processing computer is under development as a prototype of robotic systems for visual inspection of the interior surfaces of pipes and especially of gas pipelines. The system is capable of providing both forward views and mosaicked radial views that can be displayed in real time or after inspection. To avoid the complexities associated with moving parts and to provide simultaneous forward and radial views, the video camera is equipped with a wide-angle (>165 ) fish-eye lens aimed along the axis of a pipe to be inspected. Nine white-light-emitting diodes (LEDs) placed just outside the field of view of the lens (see Figure 1) provide ample diffuse illumination for a high-contrast image of the interior pipe wall. The video camera contains a 2/3-in. (1.7-cm) charge-coupled-device (CCD) photodetector array and functions according to the National Television Standards Committee (NTSC) standard. The video output of the camera is sent to an off-the-shelf video capture board (frame grabber) by use of a peripheral component interconnect (PCI) interface in the computer, which is of the 400-MHz, Pentium II (or equivalent) class. Prior video-mosaicking techniques are applicable to narrow-field-of-view (low-distortion) images of evenly illuminated, relatively flat surfaces viewed along approximately perpendicular lines by cameras that do not rotate and that move approximately parallel to the viewed surfaces. One such technique for real-time creation of mosaic images of the ocean floor involves the use of visual correspondences based on area correlation, during both the acquisition of separate images of adjacent areas and the consolidation (equivalently, integration) of the separate images into a mosaic image, in order to insure that there are no gaps in the mosaic image. The data-processing technique used for mosaicking in the present system also involves area correlation, but with several notable differences: Because the wide-angle lens introduces considerable distortion, the image data must be processed to effectively unwarp the images (see Figure 2). The computer executes special software that includes an unwarping algorithm that takes explicit account of the cylindrical pipe geometry. To reduce the processing time needed for unwarping, parameters of the geometric mapping between the circular view of a fisheye lens and pipe wall are determined in advance from calibration images and compiled into an electronic lookup table. The software incorporates the assumption that the optical axis of the camera is parallel (rather than perpendicular) to the direction of motion of the camera. The software also compensates for the decrease in illumination with distance from the ring of LEDs.

Magruder, Darby↗

The Nagoya cosmic-ray muon spectrometer 3, part 4: Track reconstruction method

One of the greatest problems in measuring particle trajectories with an optical or visual detector system, is the reconstruction of trajectories in real space from their recorded images. In the Nagoya cosmic-ray muon spectrometer, muon tracks are detected by wide gap spark chambers and their images are recorded on the photographic film through an optical system of 10 mirrors and two cameras. For the spatial reconstruction, 42 parameters of the optical system should be known to determine the configuration of this system. It is almost impossible to measure this many parameters directly with usual techniques. In order to solve this problem, the inverse transformation method was applied. In this method, all the optical parameters are determined from the locations of fiducial marks in real space and the locations of their images on the photographic film by the non-linear least square fitting.

Shibata, S.↗

Optical Memory Stores 10 12sup. Bits

Optical Mass Memory has separate recorder (write) and reproducer (read) modules. Data are recorded on fiches and stored in a carrousel. Fische is retrieved from carrousel by transporter in under 10 seconds. Input to optical memory is standard TV camera. TV monitor at memory output displays stored video images when they are retrieved from fisches. Input to the optical memory can also be taken from pseudorandom sequence generator.

Source record↗

Cameras Would Withstand High Accelerations

Very rugged cameras with all-reflective optics proposed for use in presence of high accelerations. Optics consist of four coaxial focusing mirrors in Cassegrain configuration. Mirrors are conics or aspherics. Optics achromatic,and imaging system overall passes light from extreme ultraviolet to far infrared. Charge-coupled-device video camera, film camera, or array of photodetectors placed at focal plane. Useful as portable imagers subject to rough handling, or instrumentation cameras mounted on severely vibrating or accelerating vehicles.

Meinel, Aden B.↗

Tracking-station coordinates from Geos 1 and Geos 2 optical flash data.

Center-of-mass coordinates for 28 NASA MOTS and SAO Baker-Nunn camera sites have been obtained from optical flash data from Geos 1 (1965 89A) and Geos 2 (1968 002A). More than 25,000 observations in about 100 two-day arcs were used in dynamical solutions (SAO 1969 AGU gravity model). Comparison of results with local survey solutions and with solutions from deep-space vehicle tracking suggests accuracy of about 2 meters in longitude and height and 5 meters in latitude. The relatively larger error in latitude arose from propagation of gravity-model error largely along the track of these high-inclination satellites. The results have also been compared with the solutions of the SAO 1969 standard earth for station coordinates on the North American datum. The solution obtained in the present work is much closer to the survey results in chord length between stations.

Marsh, J. G.↗

The facsimile camera - Its potential as a planetary lander imaging system

The facsimile camera is an optical-mechanical scanning device which is an attractive candidate for planetary lander imaging systems and has been selected for the Viking/Mars mission because of its light weight, small size, and low power requirement. Other advantages are that it can provide good radiometric and photogrammetric accuracy because the complete field of view is scanned with a single photodetector located on or near the optical axis of the objective lens. In addition, this device has the potential capability of multispectral imaging and spectrometric measurements.

Huck, F. O.↗

A statistical model for evaluating GOPEX uplink performance

This article describes a statistical model to analyze the signal intensity received at the solid-state imaging (SSI) camera of the Galileo optical communications system from an Earth-based transmitter (GOPEX) demonstration. The analytical model assumes that the optical beam possesses a Gaussian profile and the communication channel has a log-normal scattering characteristic. The atmospheric-induced jitter is modelled as two independent zero mean Gaussian random variables. By modelling the system parameters as a set of independent and identically distributed (iid) random variables, the combined impact of uncertainties due to system parameters and the turbulent atmosphere can be approximated by a log-normal distributed signal intensity at the spacecraft. A Monte-Carlo software simulation package was also developed to compute the confidence interval probabilities for general optical beam profiles. Numerical results show that the approximation is valid for a wide range of operation scenarios.

Kiesaleh, K.↗

Hubble Space Telescope characterized by using phase-retrieval algorithms

We describe several results characterizing the Hubble Space Telescope from measured point spread functions by using phase-retrieval algorithms. The Cramer-Rao lower bounds show that point spread functions taken well out of focus result in smaller errors when aberrations are estimated and that, for those images, photon noise is not a limiting factor. Reconstruction experiments with both simulated and real data show that the calculation of wave-front propagation by the retrieval algorithms must be performed with a multiple-plane propagation rather than a simple fast Fourier transform to ensure the high accuracy required. Pupil reconstruction was performed and indicates a misalignment of the optical axis of a camera relay telescope relative to the main telescope. After we accounted for measured spherical aberration in the relay telescope, our estimate of the conic constant of the primary mirror of the HST was - 1.0144.

Fienup, J. R.↗

Near-Infrared Hyperspectral Image Cubes of Mars during the 1999 Opposition

We used the Goddard Space Flight Center, Acousto-Optic Tunable Filter (AOTF) Camera to obtain near-IR spectral image sets of Mars over the 1.6-3.6 micron region during the April 1999 opposition. A complete image set consists of 280 images with a spectral full-width-half maximum of 10 wavenumbers (fixed in frequency), 90 images in H-band (1.55-1.80 micron), 115 images in K-band (1.95-2.50 micron) and 75 images in L-band (2.90-3.70 micron). The short-wavelength limit is set by transmission of AOTF cell and long-wavelength limit is imposed by sensitivity of PICNIC, 256x256, HgCdTe array detector. We will discuss the new array performance and provide preliminary interpretations of some of these results. These measurements were part of a 4-observatory coordinated effort whose overall objective was to assemble a photometrically calibrated, spectrally complete ground-based image cube over the visible and near-IR spectral region. To accomplish this, four observing teams conducted the investigations with instruments spanning 0.4 to 5.0 micron. The instruments and observing facilities were (a) AOTF camera at Apache Point Observatory, 3.5m, f/10, Nasymth focus (this abstract). Primary science targets included the 3 micron water-of hydration feature and CO2, H2O ice (polar regions and clouds); (b) Visible/NIR interference-filter (24 filters) camera at Lowell Observatory, 72" telescope. 430-1050 nm. Science targets were Fe(2+), Fe(3+) mineralogy and coarse grain hematite search; (c) NMSU Tortugas Mountain Observatory, 60 cm telescope, CCD photometry with same filter set as Lowell; (d) KPNO cryogenic grating/slit spectrometer (CRSP/SALLY) at KPNO 2.1 m, f/15 Cassegrain focus (see abstract by D. Glenar, et. al., this meeting). Selected wavelengths in 3-5 micron region (L, M band). Science targets included water-of-hydration feature (3-4 micron long wave extension) and sulfate mineralogy. Observers participating in this campaign included Dave Glenar, John Hillman, Gordon Bjoraker and Fred Espenak from GSFC, Nancy Chanover, Jim Murphy and A. S. MurTell from NMSU, Leslie Young from BU, Diana Blaney from JPL and Dick Joyce from KPNO.

Hillman, John J.↗

A Third Arm for the Surgeon

In laparoscopic surgery, tiny incisions are made in the patient's body and a laparoscope (an optical tube with a camera at the end) is inserted. The camera's image is projected onto two video screens, whose views guide the surgeon through the procedure. AESOP, a medical robot developed by Computer Motion, Inc. with NASA assistance, eliminates the need for a human assistant to operate the camera. The surgeon uses a foot pedal control to move the device, allowing him to use both hands during the surgery. Miscommunication is avoided; AESOP's movement is smooth and steady, and the memory vision is invaluable. Operations can be completed more quickly, and the patient spends less time under anesthesia. AESOP has been approved by the FDA.

Source record↗

The Star Formation History of Orion and its Environs

During the period of performance, we have obtained the following observations and carried out the analysis of the Orion associations itemized below. Optical Photometry: The Quest camera that had been damaged by lightning on Sept. 2001 was reconfigured to use 10 chips and only 3 filters instead of the original 4 but retaining its spatial coverage of 2.3deg wide in declination. During the Winter and Fall 2002 observing campaigns, we obtained multifilter photometry using the Quest camera on the 1mt Schmidt of the Venezuelan National Observatory, to continue the survey of the Orion clouds. In the Winter 2002 season, we obtained photometry for 10 scans at DEC=+5, 7 scans at DEC=-5. Several additional scans at DEC=-3 were obtained during the Fall 2002 observing campaign. Slit spectroscopy of bright candidates: During 2002 spectra for some 235 candidate PMS stars were obtained with the FAST spectrograph at the SAO 1.5m telescope in Mt. Hopkins. These objects, all brighter than V=16, are located in two strips centered at DEC=+l and -5, and spanning from RA=5h-6h. The spectra are being analyzed. Multifiber spectroscopy: Spectroscopy for our fainter (V less than or equal to 16) candidates has not kept pace with our spectroscopy of brighter candidates, because of the delay in the commissioning of the Hectospec and Hectoechelle multi-object spectrographs at the new 6.5m MMT. We obtained some data with the Hydra spectrograph on the WIYN telescope: Feb 1-4, 2002. Time granted to the project: "A Large Scale Survey of the Low-Mass Young Population in the Orion OB1 Association" (P.I.: C. Briceno). Three half-nights (we used the first half of the night, the second half of the night was used with the Mini-Mosaic imager by another team). Only the first half night was clear. We observed 3 fields centered in a 2.3 deg wide strip centered at DEC=-1 and spanning RA=Sh to 6h. A total of 250 spectra were obtained for the same number of candidate PMS stars. Nov. 13-15, 2002. Time granted to the project "Cluster survey of protoplanetary disk evolution", (P.I.: A. Sicilia-Aguilar). Clear weather throughout. We obtained spectra for some 200 candidate PMS stars in 3 fields located in a 2.3 deg wide strip centered at DEC=+l and spanning from RA=5h20m to 5h35m. Data for both observing runs is partially reduced and is being analyzed. U photometry: During Nov.29-Dec.4, 2002 we were granted time with the 4-shooter CCD Mosaic Camera at the SAO 1.2m telescope, to obtain U-band photometry of a subset of the newly identified T Tauri stars in the strip centered at DEC=-1. This sample is composed of strong H(alpha) emitting PMS stars (Classical T Tauri stars) located mostly in the Orion OB lb association, around the Orion Belt area. Our data will be combined with our calibration of the U-band excess (Gullbring et al. 1998) to derive mass accretion rates. Because of bad weather we observed only 20 stars during 1.5 clear nights. Near IR photometry: During Dec. 14-19, 2002 we used the IR Camera on the SAO 1.2m telescope, to obtain L-band photometry of a set of 17 the newly identified Orion OB 1a and 1b stars, in order to look for IR excess emission coming from the hotter inner parts of circumstellar disks. Again, mediocre weather prevented a larger set to be observed. These stars were also observed with the OSCIR mid-IR camera on Gemini North during later 2001. Our goal is to construct SEDs from the visual out to the mid-IR (by combining our optical/IR data with 2MASS JHK magnitudes) in order to explore disk dissipation at the critical ages of 5-10 Myr spanned by these stars.

Calvet, Nuria↗