Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “operator decision support”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Sensing Electrical Networks Securely & Economically (SENSE)

The growing adoption of distributed energy resources (DERs) like battery energy storage systems and roof top solar/PV and the rapid penetration of electric vehicles (EVs), the electric grid is undergoing a major transformation with elevated stress on legacy grid assets. Despite a lot of expenditure to address these challenges, both in dollars and manpower, utilities have not been able to receive the value that was promised. The gains have been most visible at the transmission and substation level, especially where the main objective was improving operational and economic efficiency for the utility. Improving visibility and control at a few select points enhances the existing and established paradigm of centralized command and control. With changing load patterns, load types and the overall transition to an “active grid”, the centralized control and coordination paradigm gets challenged. To address the challenges, a new architecture and mechanism is needed, one that supports decentralized control and decision making, extracting value streams at the grid edge, particularly as the changes are fueled by transitions occurring in the distribution system. To address this, a communications and data processing platform, “GAMMA” was developed and demonstrated through the project. At the heart of the platform, are distributed, intelligent edge nodes with sensing and compute capabilities, that can record and analyze information locally. They are embedded in sensors and actuators specific to different distribution system applications. Phase 1 of the project focused on developing novel sensor technology that can be used for monitoring utility pole top distribution transformers. The sensors were designed with the objective of being low-cost, communicating with the GAMMA cloud using novel “delay-tolerant” networking using Bluetooth and a secure mobile application. They were non-intrusive in nature so that they can be installed quickly in the field, resulting in overall low cost of deployment and operations. Following the successful completion of Phase 1, the team manufactured 100 units for a field demonstration in Phase 2. The field demonstration was carried out on two real feeder systems with the local utility partner. In total, 100 sensors were installed and operated over a period of 6 months in the state of Georgia. The platform is operational end to end, with the cloud infrastructure deployed on a distributed, serverless environment that can serve multiple data streams, an analytics engine and a portal to securely view the data from multiple assets. The data collected through the GAMMA Mobile Phone app showcased the viability of the novel delay tolerant networking architecture, and the data processing algorithms developed through the course of the project, were successful in extracting important information about the overall network, improving the utility’s visibility and situational awareness in the distribution feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impacts of Renewable Energy and Green Hydrogen Policies on Uttar Pradesh's Power Sector Future

This report is part of a broader program focused on supporting Indian states with long-term power system planning. More information about this program can be found at the National Renewable Energy Laboratory's "Supporting India's States With Renewable Energy Integration" web page at https://www.nrel.gov/international/india-renewable-energy-integration.html. The power sector in Uttar Pradesh, India's most populous state, is poised to transform over the next few decades due to a combination of national and state-level policies impacting both the supply and demand of electricity. The Government of Uttar Pradesh has policies and plans to develop in-state solar PV, pumped storage hydropower, and green hydrogen. Power system policymakers and utilities in Uttar Pradesh are faced with the challenges of planning a system that incorporates increasing amounts of renewable energy and storage resources, meets rising electricity demand due to economic development and green hydrogen production, and satisfies operational and reliability requirements. To support these various objectives, the National Renewable Energy Laboratory (NREL), RMI, and the Uttar Pradesh New and Renewable Energy Development Agency (UPNEDA) evaluated the least-cost pathways for the state's power sector through 2050. NREL developed a capacity expansion model that identifies investment and operational decisions for every year (2024-2050) for all of India, with detailed representation for the state of Uttar Pradesh, which can provide a framework for recurring planning studies. The main insights from this study can also help inform policy development and investment decisions.

08 HYDROGEN↗

Impacts of Renewable Energy and Green Hydrogen Policies on Uttar Pradesh's Power Sector Future: Additional Modeling Scenarios to Explore Hydrogen Flexibility [Slides]

This slide deck is part of a broader program focused on supporting Indian states with long-term power system planning. More information about this program can be found at the National Renewable Energy Laboratory's "Supporting India's States With Renewable Energy Integration" web page at https://www.nrel.gov/international/india-renewable-energy-integration.html. The power sector in Uttar Pradesh, India's most populous state, is poised to transform over the next few decades due to a combination of national and state-level policies impacting both the supply and demand of electricity. The Government of Uttar Pradesh has policies and plans to develop in-state solar PV, pumped storage hydropower, and green hydrogen. Power system policymakers and utilities in Uttar Pradesh are faced with the challenges of planning a system that incorporates increasing amounts of renewable energy and storage resources, meets rising electricity demand due to economic development and green hydrogen production, and satisfies operational and reliability requirements. To support these various objectives, the National Renewable Energy Laboratory (NREL), RMI, and the Uttar Pradesh New and Renewable Energy Development Agency (UPNEDA) evaluated the least-cost pathways for the state's power sector through 2050. NREL developed a capacity expansion model that identifies investment and operational decisions for every year (2024-2050) for all of India, with detailed representation for the state of Uttar Pradesh, which can provide a framework for recurring planning studies. The purpose of this slide deck is to supplement the main study (published in May 2024) with additional modeling scenarios to explore hydrogen flexibility.

08 HYDROGEN↗

The Second Wind Forecast Improvement Project (WFIP 2): General Overview

In 2015 the U.S. Department of Energy initiated a four-year study, the second Wind Forecast Improvement Project (WFIP 2), to improve the representation of boundary-layer physics and related processes in mesoscale models for better wind and wind power forecasts. This goal challenges numerical weather prediction models in complex terrain due to inherent assumptions underlying their boundary-layer parameterizations. The WFIP 2 effort involved the wind industry, universities, NOAA, and DOE's national laboratories in an integrated observational and modeling study. Observations spanned 18-months to assure a full annual cycle of continuously recorded observations from remote-sensing and in situ measurement systems. The study area comprised the Columbia Basin of eastern Washington and Oregon, containing more than 4 GW of installed wind capacity; nests of observational systems captured important atmospheric scales from mesoscale to NWP sub-grid scale. Model improvements targeted NOAA's High-Resolution Rapid Refresh (HRRR) model to facilitate transfer of improvements to NWS operational forecast models. This paper describes the general WFIP 2 scope and objectives, the particular scientific challenges of improving wind forecasts in complex terrain, early successes of the project, and an integrated approach to archiving observations and model output. It provides an introduction for a set of more detailed BAMS papers addressing WFIP 2 observational science, modeling challenges and solutions, practical transfer of boundary layer advances to industry use, and advances in coupling improved mesoscale models to microscale models that can represent interactions between wind plants and the atmosphere.

WFIP2, boundary layer, complex terrain, forecastin↗

What to expect when you're expecting engagement: Delivering procedural justice in large-scale solar energy deployment

Community engagement in the planning process to build large-scale solar (LSS) projects can win local support and advance procedural justice. However, an understanding of community engagement in current LSS development is lacking. Using responses from a U.S. nationwide survey (n = 979) of residential neighbors living within 3 miles (4.8 km) of completed LSS projects (i.e. “solar neighbors”) and project details from the U.S. Large-Scale Solar Photovoltaic Database (USPVDB), this study seeks to answer the following questions: How are solar neighbors' perceptions of community engagement associated with their attitudes toward their LSS projects? How do solar neighbors' perceptions of community engagement compare to their expectations? And, how do neighbors explain what they perceived about the planning process? We answer these questions using mixed methods, including regression modeling, a new gap analysis technique, and qualitative coding. We find that higher perceived engagement is associated with more positive attitudes toward the project, even when controlling for respondents who acted in opposition. Supporters and opponents alike expect more engagement than they perceived and information about projects both before construction and after operation is lacking. Awareness and engagement expectations increase at certain project size and proximity thresholds. However, most neighbors expect the public to offer input during engagement, but not make decisions. We contextualize these findings with explanatory comments from respondents.

14 SOLAR ENERGY↗

Power System Resilience Metrics Augmentation for Critical Load Prioritization

One of the major goals of new grid operation regimes, such as transactive energy systems (TESs), is to make the power grid more resilient to withstand natural or man-made disasters and potential reliability events, and to continue to serve the maximum number of its customers. But it is a well-known fact to system operators that not all customers are the same. This implies that any discussion of TESs’ impacts on the resilience of the power system should consider the needs of its critical customers (such as the power system operation centers, fire and police stations, and hospitals) over those of other customers. When evaluating the resilience of the system, bonus points must be awarded to any system that could maintain its power supply to critical customers during a disturbance that may cause an outage. This report discusses critical infrastructure (CI) as found in the literature and then categorizes it based on the field to which the operations belong (such as human life/safety-related, operations management, necessary city operation, industrial customers, etc.). Each of these CI categories is further divided into types of critical customers (e.g., the human life/safety-related category has different types of customers like hospitals, fire and police stations, etc.). The entire demand of each of the critical customer types is not categorized as critical load (CL); instead, only a portion of the total load of these critical customers is characterized as critical load. This is done based on the categories of equipment, the function of which is crucial in the operation of the overall facility. CL categorization is performed to provide the ratio of the critical load portion to the overall load , so that it can serve as a parameter in the resilience evaluation of the grid through a metrics-based approach. Such categorization is important as it helps to augment the existing quantifiable resilience metrics with CL categorization. The metrics for a power system need to not only consider how well a system performed during a disturbance event, but also how it reduced strain and supplied power to its CLs. The first step in this process is characterize CLs in the system. After CL characterization, the next step is the inclusion of these loads in the resilience metrics. To that end, in this report weight-based augmentation of resilience metrics is proposed, where certain customers (the ones that are categorized as critical) are assigned higher weights than others. Though an overview of assigning weights to customers is discussed, there is no one-size-fits-all approach for every power system. The decisions made about assigning such weights to customers vary greatly from one operator to another, based on their unique systems and the current and predicted states of critical customers. This decision-making can include the type of disturbance event, which might only affect certain parts of the system. In general, analyzing critical customers before an event helps understand system vulnerabilities. It also helps in planning and conducting operations during the event, evaluating system performance after the event, and supporting better planning for future events. An alternative to the current practices of managing the grid for outages is an innovative TES, which has the potential to provide a platform for including distributed energy resources for managing CLs. This report also describes how TES qualities can help (1) to maintain power supply to critical customers for uninterrupted operations and (2) to restore lost power supply to the critical customers rapidly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Updates to a Preliminary Probabilistic Performance Assessment Model for Radiological and Chemical Contamination at the West Valley Site, New York - 20420

The New York State Energy Research and Development Authority (NYSERDA) is the owner of the Western New York Nuclear Service Center (WNYNSC), a 1,351-ha site located approximately 48 km south of Buffalo, New York. In 1962, Nuclear Fuel Services, Inc. (NFS) entered into agreements with the Atomic Energy Commission and New York State to construct the first commercial reprocessing plant of nuclear fuel in the United States at the WNYNSC. NFS built and operated the spent fuel reprocessing plant and waste disposal facilities, processing 640 Mg (640 metric tons) of spent nuclear fuel from 1966 to 1972 under an Atomic Energy Commission license. Nuclear fuel reprocessing operations halted in 1972 and never restarted, leaving behind radioactive and chemical wastes. The U.S. Department of Energy (DOE) was required to complete certain waste management activities under the West Valley Demonstration Project (WVDP) Act of 1980 including decommissioning of WVDP facilities. As collaborating agencies, NYSERDA and the DOE are tasked with making decisions about decommissioning and risk reduction for the West Valley Site. Neptune and Company, Inc. (Neptune) was contracted to develop a probabilistic performance assessment (PPA) model to assist the agencies in their decision making process for decommissioning the WVDP and WNYNSC. One important tool that is needed in order to inform the decision-making process is a science-based model of the West Valley Site that evaluates potential future consequences for human health and the environment. This forms the core of the spatial domain of the West Valley PPA Model. The PPA Model, developed using the GoldSim system modeling software, is a tool intended to provide support for decision making that evaluates uncertainty, in a manner that is transparent, defensible, and robust. The PPA Model includes contaminant transport and health effects components, and is organized around geographically-grouped contaminated facilities. These include the waste disposal areas licensed by the U.S. Nuclear Regulatory Commission and the State of New York, a waste tank farm for storage of high level radioactive waste resulting from reprocessing operations, and several areas contaminated with radioactive and chemical constituents. The PPA Model evaluates contaminant transport from these sources to points of exposure across the site and into receiving surface waters and sediments. Hypothetical people and wildlife could be exposed to contamination at these locations, and the effects of these exposures are evaluated. Contaminant transport processes to be evaluated in the PPA Model include groundwater and surface water transport, contaminant translocation by plants and animals, diffusion, and erosion. The evaluation of exposures to people in this preliminary model is limited to a resident farmer scenario, and ecological assessment is performed at the level of a screening analysis. The results of these preliminary evaluations inform future model developments. PPA Model results are subjected to sensitivity analysis in order to determine those pathways and parameters that are most significant in influencing the results. This information allows analysts and decision makers to focus on those aspects of Site behavior and processes. With this information, the decision makers can drive informed, defensible decisions regarding decommissioning of the Site. This paper includes an update of the information presented at WM2019 [1]. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Neural-based time series forecasting of loss of coolant accidents in nuclear power plants

During the last few years, deep learning in neural networks has demonstrated impressive successes in the areas of computer vision, speech and image recognition, text generation, and many others. However, sensitive engineering areas such as nuclear engineering benefited less from these efficient techniques. In this work, deep learning expert systems are utilized to model and predict time series progression of a design-basis nuclear accident, featuring a loss of coolant accident. Two major findings are accomplished in this work. First, the ability to train expert systems with high accuracy, which could help nuclear power plant operators to figure out plant responses during the accident. Second, building fast, efficient, and accurate deep models to simulate nuclear phenomena, which could be valuable to nuclear computational science. In this work, large amount of time series data is obtained from simulation tools by simulating different conditions of the base-case/nominal accident scenario. Four critical outputs/responses are monitored during the accident (e.g. temperature, pressure, break flow rate, water level). Two approaches are adopted in this work. The first approach is to use feedforward deep neural networks (DNN) to fit all time steps and outputs in a single model. The second approach is to use long short-term memory (LSTM) to fit all time steps together for each reactor response separately. Both DNN and LSTM demonstrate very good performance in predicting the test and base-case scenarios, with accuracy as low as 92% and as high as 99%, where these test scenarios are unknown to the expert systems and are not included in the model training. In addition, both approaches demonstrate a significant reduction in computational costs, as the deep expert system is able to accurately predict the accident 100,000 times faster than the original simulation tool. Given sufficient data, the methodology adopted in this study demonstrates that DNN/LSTM expert systems can be used as a decision support system to model advanced time series phenomena within nuclear power plants with high accuracy and negligible computational costs.

42 ENGINEERING↗

Operating Experience Data Analysis for Digital Instrumentation and Control System Reliability and Risk Assessment in Nuclear Power Plants

The implementation of advanced digital instrumentation and control (DI&C) systems in U.S. nuclear power plants (NPPs) can bring significant advancements in reliability, monitoring, and control capabilities. However, these systems also introduce new challenges, particularly in assessing risks such as common-cause failures (CCFs) and establishing robust reliability estimates for DI&C components. Addressing these challenges is critical for ensuring the safe and efficient operation of NPPs. Recently, Idaho National Laboratory was tasked by the U.S. Nuclear Regulatory Commission (NRC) to conduct a DI&C reliability study using operating experience data from the nuclear industry. The two operating experience data sources for the study are the Institute of Nuclear Power Operations’ Industry Reporting and Information System (IRIS) and the NRC’s Licensee Event Report database which is hosted at Idaho National Laboratory at https://lersearch.inl.gov/LERSearchCriteria.aspx. This report provides a comprehensive examination of DI&C systems, including their architecture, operational advantages, and associated challenges. It reviews existing industry DI&C studies and failure mode taxonomies, along with reliability data from various industries. Through a detailed analysis of these databases, the study provides insights into DI&C system performance. Considerations should be given to incorporate DI&C failure data into the NRC's Integrated Data Collection and Coding System and updating the Reliability and Availability Data System to support ongoing DI&C reliability studies. Recommendations are also provided for modeling DI&C reliability and CCF in probabilistic risk assessment, thereby supporting risk-informed decision-making and enhancing the reliability and safety of NPPs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Technical Resilience Navigator: Risk-Informed Decision Making to Support Resilience Planning

The Technical Resilience Navigator (TRN) helps organizations manage the risk to critical functions at a site from disruptions in energy and water services. Developed in partnership by the Pacific Northwest National Laboratory and the National Renewable Energy Laboratory, under direction and funding from the Department of Energy’s Federal Energy Management Program, the TRN helps organizations enhance their resilience to a variety of disruptive events, both natural and human-caused, that could interrupt normal operations for an unknown period of time. This report provides an overview of the TRN’s risk-informed approach to resilience planning and formally describes how it uses a streamlined risk model to identify effective strategies for improving resilience.

99 GENERAL AND MISCELLANEOUS↗

City of Largo Clear Sky Assessment Process: Prioritizing Solar + Storage for Resilient Facilities & Communities

The Clear Sky Tampa Bay project was a 15-month collaborative research effort to support solar + storage deployment for community resilience in Florida. The Clear Sky Decision Support Toolkit is a collection of resources designed to support users in conducting solar + storage prioritization and feasibility screening assessments at critical facilities. The Tampa Bay Regional Planning Council worked with four local governments in the region to test and apply the Toolkit. This case study series describes how each partner government used the Toolkit and highlights key insights and lessons learned that other users could follow to replicate the process. The City of Largo used the Clear Sky Decision Support Toolkit to advance community solar + storage resilience goals by collaborating with staff across departments and disciplines and engaging with utility stakeholders. The City of Largo conducted an analysis of its Wastewater Treatment Facility (WWTF), which processes an average of 43 million gallons of wastewater daily. Water treatment operations are both critical and energy intensive, requiring sustained energy throughout the day.

14 SOLAR ENERGY↗

ARM FY2026 Radar Plan

The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility maintains a suite of advanced atmospheric radar systems that serve as critical tools in ARM’s mission to provide continuous, high-quality observations for advancing the understanding and modeling of atmospheric processes. These radar systems enable detailed characterization of clouds, precipitation, and dynamic structures in the atmosphere, supporting a broad range of scientific applications. The number of deployed systems exceeds what current staffing levels can fully support for continuous 24/7/365 operation. As such, it is essential to have a clearly defined and community-informed plan that prioritizes radar operations and communicates ARM’s strategy for sustaining and evolving these observational assets. This FY2026 Radar Plan outlines ARM’s approach to managing its radar portfolio—balancing scientific impact, operational feasibility, and long-term sustainability. It reflects ARM’s continued commitment to delivering calibrated, well-documented radar data products that enable process-level studies and support the development and evaluation of weather and climate models. Through this plan, ARM aims to ensure transparency in decision-making, alignment with user needs, and support for innovative science across the facility’s fixed and mobile observatories. Given uncertainties around the Fiscal Year (FY) 2026 budget, this plan was developed to assume business as usual and will be updated as budgets and plans may change. It should be noted that, given the limited timeframe involved, this plan will be more succinct than previous plans.

47 OTHER INSTRUMENTATION↗

Decentralized Microgrid Protection Through Relative Fault Direction Classification: Preprint

Protection in inverter-based resources (IBRs) dominated microgrids generally face significant challenges due to the low fault current and inconsistent fault behaviors from IBRs. Recently, machine learning-based approaches have attracted considerable attention to address these challenges. This paper introduces a novel decentralized protection strategy for microgrids. The proposed method decomposes the protection challenge into several distributed learning tasks, enabling individual relays to autonomously determine the direction of faults using a binary classification framework based on support vector machine (SVM) algorithms. Following the distributed fault direction estimation, classifier outcomes are shared among neighboring relays, facilitating a local decision-making process to ascertain the presence of faults within the neighborhood. Finally, a tripping signal is generated based on the classifier results of each relay to operate the circuit breaker. To test and validate this approach, a 100% renewable microgrid model is simulated in MATLAB/Simulink. In the numerical analysis, the application of SVM classifiers in our approach yields impressive results: an average relay classification accuracy of 98%, and a 96% accuracy in circuit breaker control. These findings highlight the potential of machine-learning-based approaches in enhancing the efficiency and reliability of microgrid protection systems.

decentralized algorithm↗

Investigation of Multiple Data Streams for Gearbox Bearing Fault Prediction Through Machine-Learning Models

Operations and maintenance (O&M) cost of wind plant accounts up to 30% of total energy cost, which can be reduced through continuous monitoring and successfully detecting incipient wind turbine failures. To accomplish this, condition monitoring and predictive maintenance systems are being implemented in wind industry to support O&M decision making. A wide range of approaches for condition monitoring and fault prediction have been developed. These approaches generally use historical data of wind turbines collected by Supervisory Control and Data Acquisition (SCADA) system to identify patterns that lead to failure. These SCADA data show the overall condition of a wind turbine and can be leveraged to detect when the turbine's performance is degrading and to identify if a fault is developing. However, it becomes challenging to predict the failure of a specific wind turbine gearbox bearing, because the SCADA data are often not directly linked to the component. To bridge the gap, we have investigated features calculated from SCADA data using physics-based models and the gearbox design over the years. The damaged metric we used in the physics domain is frictional energy. Combining these physics domain variables with SCADA data as inputs to various machine learning models for gearbox bearing fault prediction, we have demonstrated the benefits of leveraging both physics and data domain models. It was an attempt to improve frictional-energy-based damage metric by adding data domain inputs, as we had learned that the frictional-energy-based damage metric alone is not sufficient to single out failed bearings from healthy. As condition monitoring data (either vibration or oil debris data) has become available at more and more wind plants, we would like to evaluate whether by adding the condition monitoring data can help further improve the performance of frictional-energy-based damage metric for gearbox bearing fault prediction. Both cases by modeling through various machine learning algorithms are discussed in this study along with some observations.

fault prediction↗

Use of Digital Real-Time Simulation and Optimization to Identify Maximum Real Power Injection on Banshee Distribution Network

This study investigates the hosting capacity of the Banshee Distribution Network by optimizing the real power injection at carefully selected Distributed Energy Resource (DER) locations. The analysis is conducted within the framework of power system operational constraints, including bus voltage ranges, thermal line ratings, and transformer loading limits. A Python-based Genetic Algorithm (GA), implemented using the PyGAD library, is employed to iteratively identify the optimal power injection configuration that maximizes network utilization while preserving system reliability. The methodology integrates a real-time simulation environment using the Real-Time Digital Simulator (RTDS), allowing high-fidelity evaluation of power flow and voltage behavior under each proposed injection scenario. By coupling the optimization algorithm with real-time simulation feedback, this approach ensures that both static and dynamic constraints are enforced during the evaluation process. The GA leverages evolutionary operators such as selection, crossover, and mutation to navigate the nonlinear search space efficiently. The results of the study delineate the feasible hosting capacity at three targeted buses, reflecting maximum real power levels that can be injected without causing voltage violations, transformer overloading, or line congestion. These findings provide a decision- support tool for distribution planners and utilities aiming to integrate higher penetrations of DERs in existing infrastructure. Additionally, the work lays the foundation for extending such optimization techniques to multi-objective formulations, including economic dispatch and reactive power coordination, in future studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Use of Digital Real-Time Simulation and Optimization to Identify Maximum Real Power Injection on the Banshee Distribution Network: Preprint

This study investigates the hosting capacity of the Banshee Distribution Network by optimizing the real power injection at carefully selected Distributed Energy Resource (DER) locations. The analysis is conducted within the framework of power system operational constraints, including bus voltage ranges, thermal line ratings, and transformer loading limits. A Python-based Genetic Algorithm (GA), implemented using the PyGAD library, is employed to iteratively identify the optimal power injection configuration that maximizes network utilization while preserving system reliability. The methodology integrates a real-time simulation environment using the Real-Time Digital Simulator (RTDS), allowing high-fidelity evaluation of power flow and voltage behavior under each proposed injection scenario. By coupling the optimization algorithm with real-time simulation feedback, this approach ensures that both static and dynamic constraints are enforced during the evaluation process. The GA leverages evolutionary operators such as selection, crossover, and mutation to navigate the nonlinear search space efficiently. The results of the study delineate the feasible hosting capacity at three targeted buses, reflecting maximum real power levels that can be injected without causing voltage violations, transformer overloading, or line congestion. These findings provide a decision- support tool for distribution planners and utilities aiming to integrate higher penetrations of DERs in existing infrastructure. Additionally, the work lays the foundation for extending such optimization techniques to multi-objective formulations, including economic dispatch and reactive power coordination, in future studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Designing a Site Closure Strategy for Uranium in Groundwater and Surface Water - 19534

A site closure strategy was designed and mapped for residual uranium present in groundwater and surface water at the US DOE Office of Legacy Management (LM) Monticello Mill Tailings Site (MMTS) Operable Unit (OU) III, which is regulated under CERCLA. The MMTS is a former mill site that was used to process uranium and vanadium ore in southeastern Utah until 1960. OU III includes surface water in Montezuma Creek and groundwater present in a shallow alluvial aquifer along the creek valley for several kilometers downgradient of the former mill site. The current remedy consists of an operating pump-and-treat system, monitored natural attenuation (MNA), and institutional controls (ICs). Performance evaluations indicate that a prolonged restoration period is likely, as well as an asymptotic trend in uranium concentrations that still exceed the remediation goal. Multiple strategies and scenarios were evaluated before selecting a preferred site closure strategy. Recommendations were developed to support advancing the site towards closure over the next few years and guide the process of regulatory interactions and decision making at the MMTS OU III. Site closure is an important milestone that reflects successful remedial progress at LM sites. Post-closure site management would be maintained to ensure conditions are protective of human health and the environment. The site closure strategy was considered in the context of site remedial progress. The primary sources of groundwater contamination have been removed, including mill tailings and contaminated soils, sediment, and debris. Five-year reviews have regularly concluded that the remedy is protective of human health and environment and that ICs are effective in preventing exposure to contaminated groundwater. The affected aquifer is low-yielding and has no history of domestic use. In 2004, the final remedy selected in the Record of Decision (ROD) was MNA with ICs. However, a pump-and-treat system was installed and continues to operate as a contingency remedy in the area with the highest residual uranium concentrations. The need for a contingency pump-and-treat system was triggered by a departure of the long-term monitoring data from model projections that were used as the basis for remedy performance metrics specified in the ROD. In 2015, the pump-and-treat system was expanded. Average uranium concentrations have declined locally over time. However, monitoring data and column studies indicate that the system effectiveness will eventually become ineffective in reducing uranium concentrations, likely due to the reequilibration of uranium present in the solid matrix in various states (i.e., sorbed, precipitated). Currently, there are no agreed-upon metrics for discontinuing the contingency pump-and-treat system. Three closure strategies effectively applied at other CERCLA sites were considered at MMTS OU III: (1) restoring natural attenuation conditions and conducting MNA; (2) applying alternate concentration limits (ACLs); and (3) waiving a remedial goal based on technical impracticability (TI). Each closure strategy was evaluated in the following manner: (1) identifying the criteria and requirements associated with current regulations, policy, and guidance, (2) assessing the ability to meet those criteria based on the current site knowledge and the conceptual site model, and (3) identifying data gaps that need to be filled to further assess the closure strategy. Following this evaluation, a preferred closure strategy was selected: to transition to a remedy based on MNA and maintenance of ICs, without active remediation. Several scenarios for transitioning to the preferred closure strategy were identified. Each scenario consisted of 'if/then logic' associated with a larger decision diagram. The decision diagram considered the current conceptual site model (CSM) and potential outcomes of studies that will be conducted to fill data gaps, as well as the performance of the existing treatment system and long-term monitoring data. Two scenarios for transitioning to the preferred closure strategy were highlighted for future planning and were described in detail. For both scenarios, the preferred closure strategy includes demonstrating criteria for MNA acceptance, pump-and-treat termination, long-term monitoring, and eventual site delisting. Recommended actions over the next few years were also developed, including updating the CSM, conducting numerical modeling to predict remedial performance and time frames, conducting geochemical analyses to assess uranium fate and transport, and summarizing the lines of evidence and basis for MNA. This detailed example of the development of a site-specific closure strategy provides the thought process and decision logic used to assess uncertainty using an if/then framework; identify common elements and recommended actions to advance the site towards closure; and navigate the inherent uncertainty in the timing of future events, outcome of regulatory discussions, and remedial progress over time that is common to many complex US DOE facilities. In addition, the national regulations, policy, guidance, and state of practice regarding commonly used site closure strategies was summarized for consideration, including MNA, ACLs, and TI. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Concise Guide on Hydrogen for Ports

This Concise Guide on Hydrogen for Ports provides port stakeholders with a comprehensive overview of hydrogen as an emerging energy solution for maritime and land-based operations. It explains hydrogen’s fundamental properties, production pathways, and emissions profiles, while highlighting its potential benefits and associated challenges. The document explores practical applications for hydrogen at ports alongside considerations for storage, delivery, and integration. It also outlines implementation frameworks, stakeholder engagement approaches, and risk assessment methodologies to support informed decision-making. The guide aims to provide a pathway forward for ports that choose to consider implementation of hydrogen technology at their facility.

08 HYDROGEN↗