Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “opacity experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Influence of substrate temperature and post annealing of CuGaO{sub 2} thin films on optical and structural properties

A transparent p-type thin film CuGaO{sub 2} was deposited by using RF sputtering deposition method on plastic (PET) and glass substrate. The characteristics of the film is investigated. The thin film was deposited at temperature range from 50-250°C and the pressure inside the chamber is 1.0×10{sup −2} Torr and Argon gas was used as a working gas. The RF power is set to 100 W. The thickness of thin film is 300nm. In this experiment the transparency of the thin film is more than 70% for the visible light region. The band gap obtain is between 3.3 to 3.5 eV. The details of the results will be discussed in the conference.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Four-wave mixing in a three-level bichromatic electromagnetically induced transparency system

We investigate the four-wave mixing (FWM) phenomenon in a three-level bichromatic electromagnetically induced transparency system. Theoretical results predict that the FWM will exhibit a multipeak structure under bichromatic coupling fields. The stronger the coupling fields are, the more FWM the peaks should exhibit. Results of an experiment carried out with cold {sup 87}Rb atoms in a magneto-optical trap agree with the theoretical prediction.

74 ATOMIC AND MOLECULAR PHYSICS↗

Low-energy {omega} ({yields}{pi}{sup 0}{gamma}) meson photoproduction in the nucleus

The {pi}{sup 0{gamma}} invariant mass distribution spectra in the ({gamma},{pi}{sup 0{gamma}}) reaction were measured by the TAPS/ELSA Collaboration to look for the hadron parameters of the {omega} meson in the Nb nucleus. We study the mechanism for this reaction, where we consider that the elementary reaction in the Nb nucleus proceeds as {gamma}N{yields}{omega}N;{omega}{yields}{pi}{sup 0}{gamma}. The {omega}-meson photoproduction amplitude for this reaction is extracted from the measured four-momentum transfer distribution in the {gamma}p{yields}{omega}p reaction. The propagation of the {omega} meson and the distorted wave function for the {pi}{sup 0} meson in the final state are described by the eikonal form. The {omega} and {pi}{sup 0} mesons' nucleus optical potentials, appearing in the {omega} meson propagator and {pi}{sup 0} meson distorted wave function respectively, are estimated using the t{rho} approximation. The effects of pair correlation and color transparency are also studied. The calculated results do not show medium modification for the {omega} meson produced in the nucleus for momentum greater than 200 MeV. It occurs because the {omega} meson predominantly decays outside the nucleus. The dependence of the cross section on the final-state interaction is also investigated. The broadening of the {omega}-meson mass distribution spectra is shown to occur due to the large resolution width associated with the detector used in the experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MODULES FOR EXPERIMENTS IN STELLAR ASTROPHYSICS (MESA)

Stellar physics and evolution calculations enable a broad range of research in astrophysics. Modules for Experiments in Stellar Astrophysics (MESA) is a suite of open source, robust, efficient, thread-safe libraries for a wide range of applications in computational stellar astrophysics. A one-dimensional stellar evolution module, MESAstar, combines many of the numerical and physics modules for simulations of a wide range of stellar evolution scenarios ranging from very low mass to massive stars, including advanced evolutionary phases. MESAstar solves the fully coupled structure and composition equations simultaneously. It uses adaptive mesh refinement and sophisticated timestep controls, and supports shared memory parallelism based on OpenMP. State-of-the-art modules provide equation of state, opacity, nuclear reaction rates, element diffusion data, and atmosphere boundary conditions. Each module is constructed as a separate Fortran 95 library with its own explicitly defined public interface to facilitate independent development. Several detailed examples indicate the extensive verification and testing that is continuously performed and demonstrate the wide range of capabilities that MESA possesses. These examples include evolutionary tracks of very low mass stars, brown dwarfs, and gas giant planets to very old ages; the complete evolutionary track of a 1 M {sub sun} star from the pre-main sequence (PMS) to a cooling white dwarf; the solar sound speed profile; the evolution of intermediate-mass stars through the He-core burning phase and thermal pulses on the He-shell burning asymptotic giant branch phase; the interior structure of slowly pulsating B Stars and Beta Cepheids; the complete evolutionary tracks of massive stars from the PMS to the onset of core collapse; mass transfer from stars undergoing Roche lobe overflow; and the evolution of helium accretion onto a neutron star. MESA can be downloaded from the project Web site (http://mesa.sourceforge.net/).

79 ASTRONOMY AND ASTROPHYSICS↗

A support vector machine classifier reduces interscanner variation in the HRCT classification of regional disease pattern in diffuse lung disease: Comparison to a Bayesian classifier

Purpose: To investigate the effect of using different computed tomography (CT) scanners on the accuracy of high-resolution CT (HRCT) images in classifying regional disease patterns in patients with diffuse lung disease, support vector machine (SVM) and Bayesian classifiers were applied to multicenter data. Methods: Two experienced radiologists marked sets of 600 rectangular 20 Multiplication-Sign 20 pixel regions of interest (ROIs) on HRCT images obtained from two scanners (GE and Siemens), including 100 ROIs for each of local patterns of lungs-normal lung and five of regional pulmonary disease patterns (ground-glass opacity, reticular opacity, honeycombing, emphysema, and consolidation). Each ROI was assessed using 22 quantitative features belonging to one of the following descriptors: histogram, gradient, run-length, gray level co-occurrence matrix, low-attenuation area cluster, and top-hat transform. For automatic classification, a Bayesian classifier and a SVM classifier were compared under three different conditions. First, classification accuracies were estimated using data from each scanner. Next, data from the GE and Siemens scanners were used for training and testing, respectively, and vice versa. Finally, all ROI data were integrated regardless of the scanner type and were then trained and tested together. All experiments were performed based on forward feature selection and fivefold cross-validation with 20 repetitions. Results: For each scanner, better classification accuracies were achieved with the SVM classifier than the Bayesian classifier (92% and 82%, respectively, for the GE scanner; and 92% and 86%, respectively, for the Siemens scanner). The classification accuracies were 82%/72% for training with GE data and testing with Siemens data, and 79%/72% for the reverse. The use of training and test data obtained from the HRCT images of different scanners lowered the classification accuracy compared to the use of HRCT images from the same scanner. For integrated ROI data obtained from both scanners, the classification accuracies with the SVM and Bayesian classifiers were 92% and 77%, respectively. The selected features resulting from the classification process differed by scanner, with more features included for the classification of the integrated HRCT data than for the classification of the HRCT data from each scanner. For the integrated data, consisting of HRCT images of both scanners, the classification accuracy based on the SVM was statistically similar to the accuracy of the data obtained from each scanner. However, the classification accuracy of the integrated data using the Bayesian classifier was significantly lower than the classification accuracy of the ROI data of each scanner. Conclusions: The use of an integrated dataset along with a SVM classifier rather than a Bayesian classifier has benefits in terms of the classification accuracy of HRCT images acquired with more than one scanner. This finding is of relevance in studies involving large number of images, as is the case in a multicenter trial with different scanners.

60 APPLIED LIFE SCIENCES↗

Structural Study And Optical Properties Of TiO{sub 2} Thin Films Elaborated By Thermal Oxidation Of RF Magnetron Sputtered Ti Films

We report on the effect of thickness on the structural and optical properties of TiO{sub 2} thin films obtained by direct exposure of Ti metal film to thermal oxidation. Ti thin films with thicknesses ranging from 87 nm to 484 nm were deposited onto glass substrate by RF magnetron sputtering. Thereafter, the as-deposited Ti films were annealed in air at temperature equal to 520 deg. C. The structural evolution and optical properties of obtained TiO{sub 2} films were studied by means of Rutherford backscattering spectrometry (RBS), grazing incidence X-ray diffraction (GIXRD), scanning electron microscopy (SEM) and UV-Visible spectroscopy. The films thicknesses were extracted from RBS spectra. From X-ray diffraction spectra, we can see that all the films present three TiO{sub 2} phases (anatase, rutile and Brookite). The anatase and rutile phases exhibit a strong preferred orientation along (004) and (210) planes respectively. The grain sizes, D (nm), did not change much with increasing thickness. The average value of <D>(nm) was equal to 29 nm for anatase and 26 nm for rutile. The micrographs taken from SEM experiments indicate that the films present a dense micro structure with very small grains. Transmittance spectra show that all the films present a good transparency in the visible region. The dependence of transmittance, optical band gap and refractive index on the thickness of the films was also studied.

36 MATERIALS SCIENCE↗

Expression, Purification And Crystallization of Native And Selenomethionine Labeled Mycobacterium Tuberculosis FDG1 (Rv0407) Using a Mycobacterium Smegmatis Expression System

FGD1 is an F{sub 420}-dependent glucose-6-phosphate dehydrogenase from Mycobacterium tuberculosis that has been shown to be essential for activation of the anti-TB compound PA-824. Initial attempts to produce recombinant FGD1 using Escherichia coli as a host was unsuccessful, but when the alternative host Mycobacterium smegmatis was used, soluble protein yields of 7 mg/L of culture were achieved. Both native and selenomethionine-substituted FGD1 were obtained by culturing M. smegmatis in autoinduction media protocols originally developed for E. coli. Using these media afforded the advantages of decreased handling, as cultures did not require monitoring of optical density and induction, and reduced cost by removing the need for expensive ADC enrichment normally used in mycobacterial cultures. Selenomethionine was efficiently incorporated at levels required for multiwavelength anomalous diffraction experiments used in crystal structure determination. As far as we are aware this is the first protocol for preparation of selenomethionine-substituted protein in mycobacteria. Native and selenomethionine-labeled FGD1 were successfully crystallized by vapor diffusion, with the crystals diffracting to 2.1 AA resolution.

36 MATERIALS SCIENCE↗

Pulse propagation and optically controllable switch in coupled semiconductor-double-quantum-dot nanostructures

The problem of pulse propagation is theoretically investigated through a coupled semiconductor-double-quantum-dot (SDQD) nanostructure. Solving the coupled Maxwell–Bloch equations for the SDQD and field simultaneously, the dynamic control of pulse propagation through the medium is numerically explored. It is found that when all the control fields are in exact resonance with their corresponding transitions, a weak Gaussian-shaped probe pulse is transmitted through the medium nearly without any significant absorption and losses so that it can preserve its shape for quite a long propagation distance. In contrast, when one of the control fields is not in resonance with its corresponding transition, the probe pulse will be absorbed by the QD medium after a short distance. Then we consider the probe pulses with higher intensities. It is realized that an intense probe pulse experiences remarkable absorption and broadening during propagation. Finally, we demonstrate that this SDQD system can be employed as an optically controllable switch for the wave propagation to transit from an absorbing phase to a perfect transparency for the probe field. The required time for such switch is also estimated through realistic values.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Strengthened lithium for x-ray blast windows

Lithium's high x-ray transparency makes it an attractive material for windows intended to protect soft x-ray diagnostics in high energy density experiments. Pure lithium is soft and weak, but lithium mixed with lithium hydride powder becomes harder and stronger, in principle without any additional x-ray absorption. A comparison with the standard material for x-ray windows, beryllium, suggests that lithium or lithium strengthened by lithium hydride may well be an excellent option for such windows.

36 MATERIALS SCIENCE↗

Deflection of slow light by magneto-optically controlled atomic media

We present a semiclassical theory for light deflection by a coherent {lambda}-type three-level atomic medium in an inhomogeneous magnetic field or an inhomogeneous control laser. When the atomic energy levels (or the Rabi coupling by the control laser) are position-dependent due to the Zeeman effect caused by the inhomogeneous magnetic field (or due to inhomogeneity of the control field profile), the spatial dependence of the refraction index of the atomic medium will result in an observable deflection of slow signal light when the electromagnetically induced transparency cancels medium absorption. Our theoretical approach based on Fermat's principle in geometrical optics not only provides a consistent explanation for the most recent experiment in a straightforward way, but also predicts the two-photon detuning dependent behaviors and larger deflection angles by three orders of magnitude for the slow signal light deflection by the atomic media in an inhomogeneous off-resonant control laser field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ionization and temperature measurements in warm dense copper using x-ray absorption spectroscopy

We detail experimental results inferring ionization and temperature for warm dense copper plasmas at several times solid density (15–25 g/cm 3 ) and temperatures of 10–21 eV. Experiments performed at the OMEGA Laser Facility generate uniform warm dense matter conditions via symmetric shock compression of a buried copper layer. The plasma is probed with a laser-generated x-ray source to collect the K-shell x-ray absorption spectrum. Fitting bound-bound absorption contributions from constituent charge states of copper provides an estimated $\overline{Z}$ of approximately 4–7 for these warm dense copper plasmas. We find that these partially ionized plasmas have K-edge shifts of 12–30 eV and bound-bound resonance 1s → 3p absorption shifts of 4–26 eV with respect to the cold K edge. This study provides necessary experimental data to improve ionization and opacity models in the warm dense matter regime.

42 ENGINEERING↗

Compact wire array sources: power scaling and implosion physics.

A series of ten shots were performed on the Saturn generator in short pulse mode in order to study planar and small-diameter cylindrical tungsten wire arrays at {approx}5 MA current levels and 50-60 ns implosion times as candidates for compact z-pinch radiation sources. A new vacuum hohlraum configuration has been proposed in which multiple z pinches are driven in parallel by a pulsed power generator. Each pinch resides in a separate return current cage, serving also as a primary hohlraum. A collection of such radiation sources surround a compact secondary hohlraum, which may potentially provide an attractive Planckian radiation source or house an inertial confinement fusion fuel capsule. Prior to studying this concept experimentally or numerically, advanced compact wire array loads must be developed and their scaling behavior understood. The 2008 Saturn planar array experiments extend the data set presented in Ref. [1], which studied planar arrays at {approx}3 MA, 100 ns in Saturn long pulse mode. Planar wire array power and yield scaling studies now include current levels directly applicable to multi-pinch experiments that could be performed on the 25 MA Z machine. A maximum total x-ray power of 15 TW (250 kJ in the main pulse, 330 kJ total yield) was observed with a 12-mm-wide planar array at 5.3 MA, 52 ns. The full data set indicates power scaling that is sub-quadratic with load current, while total and main pulse yields are closer to quadratic; these trends are similar to observations of compact cylindrical tungsten arrays on Z. We continue the investigation of energy coupling in these short pulse Saturn experiments using zero-dimensional-type implosion modeling and pinhole imaging, indicating 16 cm/?s implosion velocity in a 12-mm-wide array. The same phenomena of significant trailing mass and evidence for resistive heating are observed at 5 MA as at 3 MA. 17 kJ of Al K-shell radiation was obtained in one Al planar array fielded at 5.5 MA, 57 ns and we compare this to cylindrical array results in the context of a K-shell yield scaling model. We have also performed an initial study of compact 3 mm diameter cylindrical wire arrays, which are alternate candidates for a multi-pinch vacuum hohlraum concept. These massive 3.4 and 6 mg/cm loads may have been impacted by opacity, producing a maximum x-ray power of 7 TW at 4.5 MA, 45 ns. Future research directions in compact x-ray sources are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum-Cascade Lasers Generating at the 4.8-μm Wavelength at Room Temperature

We report on room-temperature generation at the 4.8-μm wavelength in a lattice-matched structure of a quantum cascade laser (QCL) grown on indium phosphide (InP) substrate. Laser heterostructures grown by molecular beam epitaxy (MBE) comprised 30 cascades and were designed to generate at the 4.80 μm wavelength corresponding to an atmospheric transparency window. Experiments demonstrated effective lasing at temperatures from 80 to 300 K on a wavelength coinciding with the calculated value, which confirmed the high quality of interfaces, high precision of layer thicknesses, and high accuracy of active region doping.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic-resonance-enhanced nonlinear optical frequency conversion with entangled photon pairs

We theoretically study nonlinear optical frequency conversion with time-frequency entangled paired photons whose sum frequency is on two-photon resonance of an atomic ensemble. Assisted by a strong coupling laser, two paired photons with wide spectrum are converted into a single monochromatic photon. The on-resonance nonlinear process is made possible due to the electromagnetically induced transparency that not only eliminates the on-resonance absorption but also enhances the nonlinear interaction between the single photons and atoms. Compared to this quantum-nonlinear conversion, the classical corresponding single-photon counts from accidental two-photon coincidence has a wide spectrum and experiences large absorption. As a result, the system can be used as an efficient two-photon quantum correlator in which the classical accidental coincidences can be suppressed. We perform numerical simulations basing on a Rb atomic vapor cell with realistic operating parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterizing falling particle curtain receivers at commercially relevant scales: Research Performance Progress Report (RPPR-1)

Sandia will construct a cold flow receiver test platform in order to characterize falling particle curtain receivers at commercially relevant scales. While Sandia has extensive experience in R&D of falling particle curtain receivers, most have been at pilot scale and smaller - on the order of 1 MWth with characteristic dimensions of nominally 1-2 m to adequately collect solar energy from the heliostat field at the National Solar Thermal Test Facility (NSTTF). However, scaling up receivers to commercially relevant scales (25 MWth and above) will require a thorough understanding of particle curtain dynamics at larger scales, especially longer drop heights, for design certainty. The goal of this project will be to construct a cold falling particle curtain test rig capable of simulating particle characteristics that are expected in a commercial scale CSP plant, namely the drop height, curtain thickness, and particle mass flow rate (normalized by length of curtain). This will enable data collection on curtain opacity and spread, both of which are correlated to receiver efficiency and reliable construction, for commercially relevant scales. It will also permit validation of numerical models that will enable detailed receiver characterization and design past currently validated scales.

14 SOLAR ENERGY↗

Observation of atomic localization using electromagnetically induced transparency

We present a proof-of-principle experiment in which the population of an atomic level is spatially localized using the technique of electromagnetically induced transparency (EIT). The key idea is to utilize the sensitive dependence of the dark state of EIT on the intensity of the coupling laser beam. By using a sinusoidal intensity variation (standing wave), we demonstrate that the population of a specific hyperfine level can be localized much more tightly than the spatial period.

74 ATOMIC AND MOLECULAR PHYSICS↗

Characterizing falling particle curtain receivers at commercially relevant scales: Research Performance Progress Report (RPPR-1)

Sandia will construct a cold flow receiver test platform in order to characterize falling particle curtain receivers at commercially relevant scales. While Sandia has extensive experience in R&D of falling particle curtain receivers, most have been at pilot scale and smaller - on the order of 1 MW th with characteristic dimensions of nominally 1-2 m to adequately collect solar energy from the heliostat field at the National Solar Thermal Test Facility (NSTTF). However, scaling up receivers to commercially relevant scales (25 MW th and above) will require a thorough understanding of particle curtain dynamics at larger scales, especially longer drop heights, for design certainty. The goal of this project will be to construct a cold falling particle curtain test rig capable of simulating particle characteristics that are expected in a commercial scale CSP plant, namely the drop height, curtain thickness, and particle mass flow rate (normalized by length of curtain). This will enable data collection on curtain opacity and spread, both of which are correlated to receiver efficiency and reliable construction, for commercially relevant scales. It will also permit validation of numerical models that will enable detailed receiver characterization and design past currently validated scales.

14 SOLAR ENERGY↗