Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “office building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Wall Upgrades for Deep Energy Savings in Residential Buildings: Interim Results from a Multi-Year Study

The Pacific Northwest National Laboratory, Oak Ridge National Laboratory and the University of Minnesota are conducting a three-year, multipart study on residential retrofit wall assemblies. The project is funded by the U.S. Department of Energy’s Building Technology Office and will identify, test and verify wall assemblies for hygrothermal performance in retrofit applications. The study includes a comprehensive literature review and expert advisory group, which inform wall selection. Selected wall assemblies are then thermally simulated using EnergyPlus and THERM, and hygrothermally simulated using WUFI, to model both thermal and moisture performance of the wall assembly. Eight wall assemblies are then experimentally tested in an in-situ laboratory environment at the University of Minnesota, with a typical residential wall used as a baseline. The in-situ experiment looks at the physical hygrothermal performance of each assembly. The simulation and experimental results will be combined with an economic analysis to produce a techno-economic study of residential wall systems for deep energy retrofits. This paper presents progress after year one of the study. Wall system modeling and laboratory testing is scheduled to begin in November, 2019. We will discuss the parameters for wall selection and experimental design, which includes approaches to modeling and simulation, along with the physical experiment design. This paper will also outline the parameters for the techno-economic analysis, and criteria used to inform model development.

Antonopoulos, Chrissi A.↗

Case Study: The Tower Companies' Commercial Office Solar PV

This case study describes how the Tower Companies selected and successfully executed onsite solar photovoltaic installations at its commercial office properties and highlights the resulting increase in asset value.

solar, solar PV, photovoltaic, onsite solar, comme↗

Case Study: Healthcare Realty's Medical Office Solar PV

This case study describes how Healthcare Realty partnered with a renewable energy advisor to establish its solar program and make progress towards its energy and GHG emissions reduction goals; all of the projects in the pipeline will be financed through third-party ownership, via power purchase agreements or through a feed-in-tariff program.

solar, solar PV, photovoltaic, onsite solar, healt↗

Performance Assessment of a Dual-purpose HP-TES for a Typical Year Comparing Different Climate Zones

Complete electrification of heating and cooling systems in the United States would overload the existing electrical grid. To this end, recent research efforts have focused on energy storage as one way to reduce ever-increasing peak electricity demands. One such technology is heat pump integrated thermal-energy storage (HP-TES) systems, which can enable load-shifting and reduce demand during peak hours. In this work, a Modelica model of a 4-Ton, dual-mode (heating and cooling) HP-TES system using a room-temperature phase-change material (PCM) integrated through a secondary hydronic loop was developed and simulated for a typical meteorological year in Riverside, CA (ASHRAE Climate Zone 2B), and Chicago, IL (ASHRAE Climate Zone 5A), for a DOE small office prototype building. The COP improvement and demand reduction were analyzed during the time-of-use peak hours along with the required recharge cycle energy demand. A typical summer in Riverside, CA resulted in model-predicted peak COP increases of 50 – 100% compared to the baseline heat pump, especially at higher outdoor temperatures, coupled with maximum peak energy reductions of 22%. During shoulder and winter season simulations, heating energy savings were higher as outdoor temperatures dropped below the PCM phase change temperature. For Chicago, IL, backup heating was necessary to meet the required system capacity for very cold ambient conditions, resulting in winter peak energy savings between 16 – 60% when accounting for backup heating requirements. The recharge energy was found to be mostly below the baseline HP energy during the peak. With improved component selections and controls, the recharge energy may be reduced. The outcomes from the simulations can provide first-order estimates for potential peak energy savings, challenges, and required controls in any location before conducting any field testing.

25 ENERGY STORAGE↗

Clean Cities and Communities Overview

Clean Cities and Communities is a U.S. Department of Energy (DOE) partnership that fosters collaboration and innovation to advance transportation energy choices nationwide. More than 75 DOE-designated Clean Cities and Communities coalitions work in urban, suburban, and rural areas to deliver objective technical expertise based on a unique understanding of local markets. As partners with DOE's Transportation Technologies Office, coalitions build bridges between national priorities and local needs to create transportation energy systems that are affordable, reliable, and secure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying the effect of multiple load flexibility strategies on commercial building electricity demand and services via surrogate modeling

The expansion of commercial building demand response as a demand-side management resource for the electric grid necessitates new decision support resources for customers seeking to assess the benefit–risk tradeoffs of possible strategies for energy flexible building operations. To address this need, we, in this study, develop surrogate models that predict the impacts of several load flexibility strategies on commercial building electricity demand and indoor temperature, focusing on offices and retail buildings at multiple scales. The surrogate models are fit to a synthetic database generated via whole building simulations, which establish the relationships between the key operational features of a given strategy and potential changes in building demand and temperature across a variety of contexts. The surrogate models are translated to a Bayesian framework to allow straightforward communication of uncertainty and parameter updating given new evidence. We find strong predictive performance across the suite of models, underscoring the usefulness of the approach in guiding decisions about implementing load flexibility strategies under a particular set of operational and environmental conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Meta‐Analysis and Regression Modeling of the Impacts of Four Indoor Environmental Quality Metrics on Office Performance

Awareness of how buildings interact with the occupant experience—especially human performance—is becoming more prevalent, as seen by increasing interest and investment in healthy built environments. However, there is a need to synthesize the wide array of existing indoor environmental assessment and performance research in a way that can translate directly to building design and operation. Existing research in this area typically focuses on a single isolated metric and has not focused on making the results utilizable by building practitioners. The aim of this research is to investigate existing office performance literature through meta‐analyses and produce regression models for four indoor environmental quality (IEQ) metrics to support critical decision‐making for building operation and renovation. To reach this aim, a literature review was conducted to identify studies that measure the impact of changing ventilation rate, temperature, horizontal illuminance, and noise level in offices on occupant task performance. This repository of field and laboratory studies was analyzed to visualize the trends between the selected IEQ metrics and task performance. The temperature, ventilation rate, and horizontal illuminance regression models showed clear improvement potential when modifying indoor conditions toward the defined high‐performance range, while the regression model for noise level was inconclusive. The discussion notes the importance of designing holistically for all components of these IEQ categories to utilize the results, for example, good filtration on outdoor air for quantifying ventilation impact and uniform overhead lighting with low contrast for quantifying horizontal illuminance impact. The novelty of this work is in considering multiple facets of the indoor environment under a single, unified analysis schema and producing IEQ‐based performance gains that can directly inform cost‐benefit analyses of building design and renovation.

60 APPLIED LIFE SCIENCES↗

Partnership and Pipeline Office Overview [Slides]

Partnerships ensure a strong Laboratory and support our missions. Partnerships are critical to our success as a Laboratory: community relations, colleges and universities and technical communities, regional and national economic development through industrial partners, DOE Laboratories, and other federal agencies. The Laboratory has many tools to build and enhance partnerships. The Community Programs Office in our Northern New Mexico Region has K-12 educational programs, supports teacher professional development and retention in regional elementary, middle and high schools, and provides community college engagement. The Partnerships and Pipeline Office works with the National Security Education Center (NSEC) which has broad university engagement including New Mexico universities. The Feynman Center for Innovation is involved in 'tech transfer' to innovation asset stewardship. The External Assignments Office shares LANL's technical expertise. The Student and Postdoc Program Offices build our workforce of the future.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Advanced Energy Design Guide for K-12 School Buildings (AEDG) Training: Cooperative Research and Development Final Report, CRADA Number CRD-18-00761

U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (BTO), Commercial Buildings Integration (CBI) Program supports the adoption of zero energy ready buildings design practices through targeted Science, Technology, Engineering, and Mathematics (STEM) workforce development. The National Renewable Energy Laboratory (NREL) identified the opportunity to provided targeted training to those professionals that have the greatest potential to impact adoption and successful design outcomes of zero energy ready buildings projects. In January 2018, ASHRAE released Achieving Zero Energy: Advanced Energy Design Guide for K-12 School Buildings (AEDG). The AEDG was developed in collaboration with NREL, American Institute of Architects (AIA), American Society of Heating, Refrigeration and Air-conditioning Engineers (ASHRAE), U.S. Green Building Council (USGBC), and Illuminating Engineers Society (IES). The purpose of this CRADA was to create a partnership between NREL, AIA, ASHRAE, USGBC, and IES to create and host on-demand, web-based training based on the AEDG.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Developing and Evaluating Metrics for Demand Flexibility in Buildings: Comparing Simulations and Field Data

Building demand flexibility (DF) has attracted significant attention in recent years among researchers, technology developers and control companies, aggregators, utilities, and many others. There are numerous challenges with today’s electricity systems such as managing peak demand capacity and integrating variable renewables into the grid. Flexible building loads can provide various grid services to help reduce electricity costs, smooth out renewables intermittency and balance supply and demand. Recognizing this, the US DOE is leading the Grid-interactive Efficient Buildings (GEB) initiative which includes research to evaluate the potential, availability and timing of flexible loads. In this paper we present load shed metrics for three building types – medium office, large office and retail store – and compare prototype simulation results with measured data from 12 actual buildings that participated in hot summertime utility demand response (DR) events. The DR strategies included varying zone temperature and reducing light levels. The magnitude of a key DF metric, “demand decrease intensity” (or “shed intensity”) (W/ft2), between the simulation results and field data are similar (14-32% differences) for both mean and median values, though the field data show much larger variation among DR events. The coefficient p-values from linear regression model tests showed that outside air temperature is a significant variable for the whole building shed intensity when the resetting zone temperature strategy is deployed. These findings support the concept of using prototype building simulation to estimate building DF and expanding future simulation research to additional building types and climate zones.

Liu, Jingjing↗

Mitigation for Removal of Building 01-103 in the Area 1 Subdock, Nevada National Security Site, Nye County, Nevada

Building 01-103, the Drill Bit Repair Building was originally recorded as SHPO Resource No. B18848 in 2020 during an architectural survey of the Area 1 Subdock (Collins et al. 2022). It was recommended individually eligible for listing in the NRHP under Criteria A and C and contributing to the significance of the Area 1 Subdock Historic District. The SHPO concurred with these determinations in a letter dated April 29, 2022 (Reed 2022). The Drill Bit Repair Building retains all seven aspects of integrity. The location, materials, workmanship, feeling, and association have not changed since its original construction. The design was modified slightly in 1996 with the addition of a removable and non-destructive chain-link fence. Nearby buildings 01-101 and 01-102 were removed (Collins and Menocal 2020) but the other buildings and storage yards remain. Therefore, the integrity of setting has been changed, but not to the degree that the building no longer conveys its significance (see Figures 4 and 5 for comparison). Building 01-103 was constructed in 1985 to coincide with the relocation of the Area 3 Subdock to Area 1. The design for the new Subdock provided a centralized cluster of buildings surrounded by two large storage yards. The buildings included administrative and engineering office space, warehouses, a radiograph building, and Building 01-103 as the drill bit maintenance and repair building, among others. The Drill Bit Repair Building was critical to the success of underground nuclear testing and is eligible under Criterion A for its contribution to broad patterns of history by maintaining specially designed equipment for underground nuclear testing at the NNSS. It is also eligible under Criterion C as it is the only recorded example of a facility built specifically for the maintenance of big-hole drill bits on the NNSS. As it retains both significance and integrity, it remains individually eligible under Criteria A and C. In addition to its individual significance, the Drill Bit Repair Building also contributes to the significance of the Area 1 Subdock Historic District as a representative of a big-hole drilling support facility necessary for underground nuclear testing. The building and the equipment therein were designed specifically for testing at the NNSS, where much of the early technology and methods for big-hole drilling were developed. Its removal will result in not only the demolition of a contributing element but also a change in the physical features of the district’s setting that contribute to its historic significance. The change in setting will diminish the district’s integrity. However, the district still contains numerous examples of other buildings constructed for the purpose of supporting big-hole drilling and remains eligible under Criteria A and C.

54 ENVIRONMENTAL SCIENCES↗

An Architectural Survey of the Pluto Test Bunker Facility, Nevada National Security Site, Nye County, Nevada

The U.S. Department of Energy (DOE), in conjunction with the National Nuclear Security Administration Nevada Field Office (NNSA/NFO), proposes to reactivate Building 26-2205 as part of a project to detect foundry-type operations with remote sensing. The project is known as the Signals Exploration Testbed, or SET for short. Building 26-2205 (State Historic Preservation Office [SHPO] Resource No. B11558) is the former Compressor Building for the Pluto Program in Area 26 of the Nevada National Security Site (NNSS). Proposed actions at Building 26-2205 include removal of exterior building and site features, such as fencing, concrete pads, a large steel tank, and visible utilities, as well as interior changes to the building’s floor plan. These activities constitute an undertaking subject to review under Section 106 of the National Historic Preservation Act (NHPA) (54 United States Code [USC] § 306101) and its implementing regulations, 36 Code of Federal Regulations (CFR) Part 800.

54 ENVIRONMENTAL SCIENCES↗

Indoor Occupant Counting by RF Backscattering

Building HVAC (heating, ventilation and air conditioning) consumes approximately 13% of all energy consumption in USA. Motion detectors, cameras and user programmable thermostats have been shown to be ineffective for HVAC controls to save energy, mostly due to the user concerns of comfort, reliability and privacy. A new HVAC control system based on real-time occupant counting that is fully automated, highly accurate, economically sensible and preserving privacy and aesthetics can thus bring forth a disruptive impact to this large energy sector. Our indoor occupant monitoring technology is based on the radio-frequency identification system (RFID), deployed in the room, not on the occupants. One reader with four antennas can be deployed on the ceiling or behind the ceiling panels for every thousand square feet in home, office and assisted living, with or without room partitions. The sticker-like passive tag, 10 cents each and maintenance-free, are profusely hidden on the wall or inside the furniture at arbitrary position, preserving privacy and aesthetics. The large number of tags can realize diverse observation points to accommodate arbitrary room layouts, which is impractical by other active units of camera, infrared, radar or lidar. With 20 tags, the system can reliably detect the number of occupants. For 100 tags, occupant posture and location can be known. The technology has been verified in the research labs and test buildings with very high accuracy. When the real-time occupant number can be accurately known without assuming devices on occupants or occupant motion, the building HVAC system can be automated to achieve building energy saving without sacrificing occupant comfort. According to our limited testing in a few types of building models and the simplified cost calculation, the RFID system has low overall cost in production, deployment, operation and maintenance. The signal processing algorithm based on machine learning requires very small number of training cases as most learning is transferrable for various layouts, and very low computational needs during operation, according to our testing in four different room sizes and layouts. In our preliminary estimate from HVAC saving alone, the RFID system can potentially pay for itself within 1.5 years, in addition to the other enhancement in building automation systems (BAS). Our commercialization strategy and business pitch deck focus on venturing this Cornell occupant monitoring technology into BAS and energy management markets. We have identified three broad BAS market segments of senior living, residential buildings, and office buildings. We have put together the minimum viable product characteristics for these identified segments, including analyses on total cost and competing technologies, as well as the fit and technical gaps for these market segments. We intend to bring the technology to market by licensing or partnering with existing BAS vendors. A list of potential collaborators and licensing partner candidates was assembled for different aspects of integrating our technology into a potential product that can be used with BAS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Making Northway, Alaska Resilient and Sustainable Through Energy Efficiency and Solar Power

This project implemented energy efficiency measures and installed 6 kW solar arrays on three community buildings in Northway, Alaska, in a collaboration between the Department of Energy - Office of Indian Energy Policy and Programs, the Northway Village Council (NVC), the Tanana Chiefs Conference (TCC), and the Alaska Native Tribal Health Consortium (ANTHC). Northway is a small community in interior Alaska, close to the Canadian border, with high fuel and energy costs: $3.00 per gallon of diesel and $0.56 per kWh, respectively, in 2016, when the project began. The energy efficiency and solar power installation plans aligned with Northway’s long-term energy goals of increasing renewable energy and decreasing reliance on fossil fuels, per the Northway Community Energy Action Plan, the Alaska Interior Regional Energy Plan, and TCC Comprehensive Economic Development Strategy. The project focused on three buildings: (1) the community hall (and later office) building, (2) the washeteria building, and (3) the water/sewer garage. It included multiple directions for energy efficiency measures, such as installing LED lighting upgrades, programmable thermostats, vending machine energy misers, efficient pumps, and adding glycol loops at the water/sewer plant. Since the village has a high potential for solar energy, in order to increase resilience and decrease costs, solar systems were installed on three community buildings. Later, a battery was installed in the community hall to capture solar power produced but not used during the day, and allow the flexibility to use that power during evening and night, further decreasing the reliance on grid power for that building. Electricity savings realized by the village between 2011-2012 and 2018-2019 by improving energy efficiencies in the buildings and adding solar was 23%. This is despite the community hall doubling in size during the same time period. If that is taken into consideration (by adding community hall usage into the 2011-2012 usage one additional time), the energy savings from 2011-2012 to 2018-2019 was 37%.

14 SOLAR ENERGY↗

Historic Significance and Current Condition Assessment of Building 06-CP-10, Device Assembly Building, Area 6, Nevada National Security Site, Nye County, Nevada

This report was produced in partial fulfillment of the mitigation of adverse effects to Building 06-CP-10, the first device assembly building on the Nevada National Security Site (NNSS), and is intended to comply with the 2021 Memorandum of Agreement DE-GM58-21NA25543 Between the U.S. Department of Energy and the Nevada State Historic Preservation Officer Regarding Demolition of Fourteen Buildings and Structures in Area 6 of the Nevada National Security Site, Nye County (hereafter referred to as the MOA). This MOA was executed to resolve adverse effects from the U.S. Department of Energy (DOE) plan to demolish 14 architectural resources at the Control Point and in the vicinity in Area 6 of the NNSS. The management and operations contractor for the NNSS identified these 14 architectural resources as environmental hazards unsafe for human occupation due to deterioration and rodent infestation. Building 06-CP-10 and two small magazine bunkers (06-CP-10A and 06-CP-805) associated with Building 06-CP-10 are scheduled for demolition as part of this undertaking. Building 06-CP-10 was originally recorded in 2003 during a historical evaluation of four buildings in Area 6. In consultation with the Nevada State Historic Preservation Office, the building was determined individually eligible for inclusion in the NRHP under the Secretary of the Interior’s Significance Criterion A because of its association with nuclear testing and under Significance Criterion C as a distinct type of construction associated with the nuclear industry. Building 06-CP-10A, a munitions magazine, and 06- CP-805, a cap-and-fuse bunker, have been recorded as contributing accessory resources to 06-CP-10. Pursuant to Stipulation III.C.3 of the MOA, this report provides a summary of the historic significance of Building 06-CP-10 and a description of its current condition and accessory resources. In addition, an updated Architectural Resource Assessment (ARA) form with new information and photographs is included in the appendix in fulfillment of Stipulation III.C.2.

54 ENVIRONMENTAL SCIENCES↗

Commercial Energy Code Compliance – Just the Facts, Ma’am

What percent of newly constructed commercial buildings comply with the energy code? How much energy and cost could be saved if the compliance increased? Which code requirements have both low compliance rates and high savings potential? These are the questions U.S. Department of Energy (DOE) is trying to answer through its Commercial Energy Code Field Study. Previous commercial studies have been very limited and did not result in a widely accepted and tested methodology. DOE’s goal is to create a standardized methodology that can produce actionable results at a reasonable study cost, that can be used by state and local governments and utilities and provides valuable information to policy makers. This paper builds on the methodology presented at the 2016 Summer Study and provides a first glimpse of the results as seen in the field. The field study team has implemented the pilot methodology, compiling a data set of over 200 office and retail buildings in climate zones 2A and 5A. The approach is based on identifying lost savings on a total energy cost basis rather than simply counting the quantity of measures that do not meet code. This paper will review the findings of that analysis, discuss critical aspects of the methodology, such as sampling and recruitment strategies, and identify areas where the greatest return—bang for the buck—exists in improving compliance with codes in commercial buildings. In addition, the team will make specific recommendations for jurisdictions looking to use the methodology to maximize energy code savings achieved in the field.

Cheslak, Kimberly↗