Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “occupancy modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Evaluation of the Energy, Hygrothermal, and Thermal Capacity Performance of Cross-Laminated Timber

Cross-laminated timber (CLT) construction is gaining momentum in the US because it offers multiple advantages over traditional construction methods. Benefits that have received the most attention focus on constructability, the environment, and protection (e.g., blast resistance), although CLT construction is likely to offer other benefits, as well. Still, these have not been studied at length because such evaluations are costly, requiring long-term assessments in an actual building and specialized technical knowledge. Among the possible benefits, CLT construction likely provides a higher-performing building envelope. Using CLT panels to enclose a building means fewer joints in the opaque envelope than what is required in traditional stick-framed construction. Fewer joints mean fewer locations where the air- and water-resistive barrier (WRB) could be compromised; thus, a CLT building enclosure may require less maintenance and have a longer lifespan than a traditionally built structure because of fewer air and water leaks. In addition, CLT’s thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours, reducing operational energy consumption throughout the lifetime of the CLT building (Salonvaara et al., 2022). Furthermore, more stable indoor temperatures can increase occupant comfort. The CLT’s thermal mass can also reduce energy costs by adjusting to utility time-of-use pricing without affecting occupant comfort. The ability of CLT buildings to bridge periods without HVAC operation prepares them for future grid interaction and provides a certain level of resilience against power outages. Researchers have attempted to quantify these benefits; however, their work is based on simplified simulations with numerous assumptions. To correctly understand the benefits, an actual building must be monitored. Therefore, information needs to be gathered on indoor and outdoor temperatures, HVAC energy consumption, thermostat setpoints, temperatures, and thermal transport in CLT components to comprehend how these parameters are affected by the CLT’s thermal mass. These data are needed to reduce the number of assumptions and calibrate simulation models to optimize HVAC controls to minimize overall energy consumption, reduce energy use and higher fees during peak demand, and maintain occupant comfort. Additionally, the calibrated simulation model allows the optimization exercise to be repeated in various US climates. Potential benefits can be tailored to buildings in various locations, and decisions can be made on where CLT construction could be most advantageous. Furthermore, monitoring and simulation results are needed to evaluate the durability of the CLT structures in different climates. This project’s researchers gathered information to help understand and quantify the benefits of CLT buildings concerning operational energy, moderated indoor temperatures, and comfort; the dynamic operation to provide grid services; and resilience in times of power outage. Through the corroboration of simulation models with real-world measurements, this study paves the way for extrapolating findings to other climatic zones and building typologies, thereby broadening the understanding of CLT’s multifaceted benefits and reinforcing its position as a material of choice in sustainable construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a New Chelation Model: Bioassay Data Interpretation and Dose Assessment after Plutonium Intake via Wound and Treatment with DTPA

The administration of chelation therapy to treat significant intakes of actinides, such as plutonium, affects the actinide’s normal biokinetics. In particular, it enhances the actinide’s rate of excretion, such that the standard biokinetic models cannot be applied directly to the chelation-affected bioassay data in order to estimate the intake and assess the radiation dose. Here we propose a new chelation model that can be applied to the chelation-affected bioassay data after plutonium intake via wound and treatment with DTPA. In the proposed model, chelation is assumed to occur in the blood, liver, and parts of the skeleton. Ten datasets, consisting of measurements of 14 C-DTPA, 238 Pu, and 239 Pu involving humans given radiolabeled DTPA and humans occupationally exposed to plutonium via wound and treated with chelation therapy, were used for model development. The combined dataset consisted of daily and cumulative excretion (urine and feces), wound counts, measurements of excised tissue, blood, and post-mortem tissue analyses of liver and skeleton. The combined data were simultaneously fit using the chelation model linked with a plutonium systemic model, which was linked to an ad hoc wound model. The proposed chelation model was used for dose assessment of the wound cases used in this study.

60 APPLIED LIFE SCIENCES↗

Hyper Suprime-Cam Year 3 results: Cosmology from galaxy clustering and weak lensing with HSC and SDSS using the emulator based halo model

We present cosmology results from a blinded joint analysis of cosmic shear, galaxy-galaxy weak lensing, and projected galaxy clustering, measured from the Hyper Suprime-Cam three-year (HSC-Y3) shape catalog and the Sloan Digital Sky Survey (SDSS) DR11 spectroscopic galaxy catalog—a cosmology analysis. We define luminosity-cut, and therefore nearly volume-limited, samples of SDSS galaxies to serve as the tracers of w p and as the lens samples for Δ⁢Σ in three spectroscopic redshift bins spanning the range 0.15± and Δ⁢Σ measurements, we use a single sample of about seven million source galaxies over 416 deg 2 , selected from HSC-Y3 based on having photometric redshifts (photo-z) greater than 0.75. The deep, high-quality HSC-Y3 data enable significant detections of the Δ⁢Σ signals, with integrated signal-to-noise ratio S/N~24 in the range 3≤R/[ℎ –1 Mpc]≤30 over the three lens samples. ξ ± has S/N ~19 in the range 8' ≤$\theta$ ≤5⁢0' and 30' ≤$\theta$ ≤15⁢0' for ξ + and ξ – , respectively. For cosmological parameter inference, we use the dark emulator package, combined with a halo occupation distribution prescription for the relation between galaxies and halos, to model w p and Δ⁢Σ down to quasinonlinear scales, and we estimate cosmological parameters after marginalizing over nuisance parameters. In our baseline analysis we employ an uninformative flat prior of the residual photo-z error, given by Π⁡(Δz ph )=$U$⁡(–1,1), to model a residual bias in the mean redshift of HSC source galaxies. Comparing the relative lensing amplitudes for Δ⁢Σ in the three redshift bins and for ξ ± with the single HSC source galaxy sample allows us to calibrate the photo-z parameter Δ⁢z ph to the precision of σ⁡(Δ⁢z ph )≃0.09. With these methods, we obtain a robust constraint on the cosmological parameters for the flat Λ⁢CDM model: S 8 =σ 8 ⁢(Ω m /0.3) 0.5 =$0.763^{+0.040}_{–0.036}$, or the best-constrained parameter given by $S^{'}_{8}$ = σ 8 ⁢(Ω m /0.3) 0.22 =0.721±0.028, determined with about 4% fractional precision. Based on multidimensional tension metrics, HSC-Y3 data exhibits about 2.5σ tension with the cosmological constraint inferred by Planck for the Λ⁢CDM model, and hints at a nonzero residual photo-z bias implying that the true mean redshift of the HSC galaxies at z ≳0.75 is higher than that implied by the original photo-z estimates.

79 ASTRONOMY AND ASTROPHYSICS↗

A Framework for Identifying Building Energy Models of Localized Utility Service Areas Using Smart Meter Data

Bottom-up load modeling of buildings offers a versatile approach to simulating baseline demand and scenarios of future technology evolution and adoption at the individual building level. This capability is essential to understanding how future load shapes may change with the adoption of electric equipment and vehicles, particularly as it relates to grid planning and infrastructure investments. Traditionally, grid planning techniques have used historical load data to predict future load and infrastructure needs. However, with the anticipated rise in adoption of electrification technologies such as heat pumps and electric vehicles, historical data become less reliable predictors of the future. By employing ResStock, a high-fidelity building stock modeling tool, we can fine-tune electrification scenarios and aggregate models to represent varying geographic resolutions of the grid system, while considering the underlying features of homes. This may enable a more accurate and responsive approach to anticipate and plan for the evolving landscape of energy demands. We present a new framework that leverages building stock energy modeling to identify building models that align with the load shapes and housing attributes of buildings with AMI data. This approach applies two model layers: (1) a classification step that identifies the presence of air conditioning, electric heating, and electric water heating, and (2) an optimization routine that identifies building energy models aligning with load profile data from advanced metering infrastructure meters. This report demonstrates one approach to deploying this framework, and presents results for three test cases that use both modeled and AMI data to assess performance. For a test case using AMI data in Fort Collins, Colorado, we observed a median monthly electricity load CV-RMSE of 16.6%, and a top ten daily heating and cooling median absolute percent error of 7.7% and 8.3%, respectively. For each AMI meter, we identify a set of potential energy models so that downstream use-cases can account for uncertainty driven by variability of baseline technologies and occupant behavior, which impact the response to electrification and energy efficiency scenarios. Our results indicate that ResStock has potential as a scalable solution for modeling residential energy demand at local grid resolutions. Its performance depends on location-specific factors, underlying building characteristics, and the level of aggregation, offering a path towards more precise and adaptive distribution grid planning for the evolving energy landscape.

24 POWER TRANSMISSION AND DISTRIBUTION↗

LA100 Equity Strategies. Chapter 6: Universal Access to Safe and Comfortable Home Temperatures

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. This chapter focuses on housing weatherization and cooling technologies as means to increase access to safe and comfortable home temperatures. Lack of cooling access and use can have severe health impacts on building occupants during heat waves. Specifically, NREL developed and used a residential building stock model to simulate the energy use of 50,000 dwellings representing the diversity of housing types, appliances, climate zones, and household incomes across Los Angeles. We compared a baseline scenario with seven upgrade scenarios. Five scenarios cooled the entire household and featured cooling systems at varying efficiency levels with various improvements to the envelope, roof, and shading, and two scenarios cooled a single room in a household with no prior cooling using either a room air-conditioning or a heat pump system. For each scenario, we evaluated impacts on utility bills, payback periods, and changes in energy burdens, as well as ability to achieve safe and comfortable temperatures. We also examined the effects of building types (multifamily vs. single-family) on indoor air temperatures. Based on the results of modeling, analysis, and community guidance, we identified six short-term and two long-term strategies for improving access to building envelope upgrades and cooling strategies that could save lives and maintain safe home temperatures for Los Angeles' low-income households during heat waves. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

air conditioning↗

Meta‐Analysis and Regression Modeling of the Impacts of Four Indoor Environmental Quality Metrics on Office Performance

Awareness of how buildings interact with the occupant experience—especially human performance—is becoming more prevalent, as seen by increasing interest and investment in healthy built environments. However, there is a need to synthesize the wide array of existing indoor environmental assessment and performance research in a way that can translate directly to building design and operation. Existing research in this area typically focuses on a single isolated metric and has not focused on making the results utilizable by building practitioners. The aim of this research is to investigate existing office performance literature through meta‐analyses and produce regression models for four indoor environmental quality (IEQ) metrics to support critical decision‐making for building operation and renovation. To reach this aim, a literature review was conducted to identify studies that measure the impact of changing ventilation rate, temperature, horizontal illuminance, and noise level in offices on occupant task performance. This repository of field and laboratory studies was analyzed to visualize the trends between the selected IEQ metrics and task performance. The temperature, ventilation rate, and horizontal illuminance regression models showed clear improvement potential when modifying indoor conditions toward the defined high‐performance range, while the regression model for noise level was inconclusive. The discussion notes the importance of designing holistically for all components of these IEQ categories to utilize the results, for example, good filtration on outdoor air for quantifying ventilation impact and uniform overhead lighting with low contrast for quantifying horizontal illuminance impact. The novelty of this work is in considering multiple facets of the indoor environment under a single, unified analysis schema and producing IEQ‐based performance gains that can directly inform cost‐benefit analyses of building design and renovation.

60 APPLIED LIFE SCIENCES↗

The completed SDSS-IV extended Baryon Oscillation Spectroscopic Survey: N -body mock challenge for the quasar sample

ABSTRACT The growth rate and expansion history of the Universe can be measured from large galaxy redshift surveys using the Alcock–Paczynski effect. We validate the Redshift Space Distortion models used in the final analysis of the Sloan Digital Sky Survey (SDSS) extended Baryon Oscillation Spectroscopic Survey (eBOSS) Data Release 16 quasar clustering sample, in configuration and Fourier space, using a series of halo occupation distribution mock catalogues generated using the OuterRim N-body simulation. We test three models on a series of non-blind mocks, in the OuterRim cosmology, and blind mocks, which have been rescaled to new cosmologies, and investigate the effects of redshift smearing and catastrophic redshifts. We find that for the non-blind mocks, the models are able to recover fσ8 to within 3 per cent and α∥ and α⊥ to within 1 per cent. The scatter in the measurements is larger for the blind mocks, due to the assumption of an incorrect fiducial cosmology. From this mock challenge, we find that all three models perform well, with similar systematic errors on fσ8, α∥, and α⊥ at the level of $\sigma _{f\sigma _8}=0.013$, $\sigma _{\alpha _\parallel }=0.012$, and $\sigma _{\alpha _\bot }=0.008$. The systematic error on the combined consensus is $\sigma _{f\sigma _8}=0.011$, $\sigma _{\alpha _\parallel }=0.008$, and $\sigma _{\alpha _\bot }=0.005$, which is used in the final DR16 analysis. For baryon acoustic oscillation fits in configuration and Fourier space, we take conservative systematic errors of $\sigma _{\alpha _\parallel }=0.010$ and $\sigma _{\alpha _\bot }=0.007$.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of Electric Vehicle Charging Behavior Patterns with Function Principal Component Analysis Approach

This manuscript focused on analyzing electric vehicles’ (EV) charging behavior patterns with a functional data analysis (FDA) approach, with the goal of providing theoretical support to the EV infrastructure planning and regulation, as well as the power grid load management. 5-year real-world charging log data from a total of 455 charging stations in Kansas City, Missouri, was used. The focuses were placed on analyzing the daily usage occupancy variability, daily energy consumption variability, and station-level usage variability. Compared with the traditional discrete-based analysis models, the proposed FDA modeling approach had unique advantages in preserving the smooth function behavior of the data, bringing more flexibility in the modeling process with little required assumptions or background knowledge on independent variables, as well as the capability of handling time series data with different lengths or sizes. In addition to the patterns revealed in the EV charging station’s occupancy and energy consumption, the differences between EV driver’s charging time and parking time were analyzed and called for the needs for parking regulation and enforcement. The different usage patterns observed at charging stations located on different land-use types were also analyzed.

Engineering↗

Machine learning predictions for local electronic properties of disordered correlated electron systems

We present a scalable machine learning (ML) model to predict local electronic properties such as on-site electron number and double occupation for disordered correlated electron systems. Our approach is based on the locality principle, or the nearsightedness nature, of many-electron systems, which means local electronic properties depend mainly on the immediate environment. A ML model is developed to encode this complex dependence of local quantities on the neighborhood. We demonstrate our approach using the square-lattice Anderson-Hubbard model, which is a paradigmatic system for studying the interplay between Mott transition and Anderson localization. We develop a lattice descriptor based on the group-theoretical method to represent the on-site random potentials within a finite region. The resultant feature variables are used as input to a multilayer fully connected neural network, which is trained from data sets of variational Monte Carlo (VMC) simulations on small systems. We show that the ML predictions agree reasonably well with the VMC data. Our work underscores the promising potential of ML methods for multiscale modeling of correlated electron systems.

36 MATERIALS SCIENCE↗

Thermodynamic Band Gap Model for Photoinduced Phase Segregation in Mixed-Halide Perovskites

Provided is a comprehensive description of a band gap thermodynamic model, which predicts and explains key features of photosegregation in lead-based, mixed-halide perovskites. The model gives a prescription for illustrating halide migration driven by photocarrier energies. Where possible, model predictions are compared with experimental results. Free energy derivations are provided for three assumptions: (1) halide mixing in the dark, (2) a fixed number of photogenerated carriers funneling to and localizing in low band gap inclusions of the alloy, and (3) the statistical occupancy of said inclusions from a bath of thermalized photocarriers in the parent material. Model predictions include excitation intensity (I exc )-dependent terminal halide stoichiometries (x terminal ), temperature-independent x terminal , excitation intensity thresholds (I exc,threshold ) below which photosegregation is suppressed, and reduced segregation in nanocrystals as compared to thin films. Here, the model also offers insight into kinetically manipulating photosegregation rates via control of underlying mediators and rationalizes asymmetries in forward and reverse photosegregation rate constants/activation energies. What emerges is a cohesive framework for understanding ubiquitous photosegregation in mixed-halide perovskites and a rational basis by which to manage the phenomenon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessing the performance of global thermostat adjustment in commercial buildings for load shifting demand response

Abstract Efficiently leveraging new sources of flexibility is critical to mitigating load balancing challenges posed by variable renewable resources. The thermal inertia of commercial buildings allows us to shift their power consumption on minute to hourly timescales to provide demand response to the grid while maintaining occupant comfort. Global thermostat adjustment (GTA) provides a readily available and scalable approach for implementing load shifting demand response using commercial heating, ventilation, and air conditioning (HVAC) systems, since it leverages the inherent sophistication of modern building automation systems. However, there is an incomplete understanding of GTA’s performance for this purpose and its impact on building systems and occupant comfort. In this paper, we explore the performance of GTA by analyzing results from nearly nine hundred experiments on eight university campus buildings in Michigan and North Carolina. Using GTA, we manipulate each building’s thermostat setpoints causing the building to shift its power consumption with respect to its baseline. We quantify the magnitude of HVAC power response, energy use of HVAC subsystems, and impact on occupant comfort. Finally, we connect our experimental results with power system operation using an optimization model that coordinates GTA actions across a large collection of grid-interactive efficient buildings (GEBs) to reduce high ramp rates on the grid and mitigate renewable energy curtailment. Overall, our work finds that the impacts on HVAC subsystems are often complex, and may result in additional energy being consumed by fans and terminal reheat. These effects must be considered when using GTA for load shifting. Additionally, we demonstrate that occupant comfort, as assessed by indoor temperature and humidity, can be maintained during GTA events. From a societal perspective, our modeling work finds that the additional renewable energy that can be integrated through the use of GTA strategies eclipses any additional energy consumed by buildings.

Keskar, Aditya (ORCID:0000000244617980)↗

Decoding Ethiopian Abodes: Towards Classifying Buildings by Occupancy Type Using Footprint Morphology

Building occupancy classification plays a crucial role in urban planning, disaster management, and population modeling. Traditional methods often require extensive field surveys or detailed datasets, which can be time-consuming, expensive, and may yield incomplete or erroneous data. In this paper, we present a novel approach for classifying buildings as residential or non-residential using only building footprint data. By extracting geometric shape derivatives that characterize building morphology, we developed a high-accuracy classification model employing a combination of unsupervised and supervised learning methods. We utilized open-source data from Open Street Map, aggregating it to create binary labels for buildings based on their respective human use type. Our approach demonstrates the potential for scalability without the need for additional data sources other than building footprints and labels, offering a more efficient solution for building occupancy classification.

Adams, Daniel↗

In-beam γ -ray spectroscopy of negative-parity states of 37 K populated in dissipative reactions

In-beam γ-ray spectroscopy was used to study excited states of the neutron-deficient nucleus 37 K populated in fast-beam inelastic-scattering and proton-removal reactions at high-momentum loss. New γ-ray transitions and γγ coincidence relationships were established using the γ-ray tracking array GRETINA. The extension of the level scheme up to the first (13/2 – ) state highlights the potential of this recently demonstrated population pathway for studies of isospin symmetry involving mirror-energy differences. Furthermore, the nature of the newly identified states is discussed in comparison to shell-model calculations with the FSU cross-shell effective interaction. The calculated occupation numbers of individual orbitals are shown to offer a consistent explanation of the measured mirror-energy differences between 37 K and 37 Ar.

20 ≤ A ≤ 38↗

Framework to select robust energy retrofit measures for residential communities

Residential building energy retrofits are essential for enhancing environmental sustainability and reducing energy costs. The selection of retrofit measures is influenced by factors such as building systems, occupant behavior, government policy, weather variability, and climate change, all of which can significantly impact energy performance. Compared to retrofitting individual homes, evaluating and selecting optimal retrofit solutions for an entire community is challenging due to diverse residential compositions and variability present. Therefore, engineering robustness is crucial for ensuring consistent energy performance and resilience across different conditions. In this context, robustness refers to the ability of a retrofit measure to maintain its functionality and remain an optimal choice despite external disturbances or changes in inputs and conditions. This study presents a framework for evaluating the robustness of multiple retrofit measures across various building systems, occupant behaviors, and environmental scenarios at the community level. The framework comprises five key steps: scenario model development, integration of the National Residential Efficiency Measures database, energy performance simulation, cost-benefit aggregation, and retrofit solution selection. Each step enhances the framework’s robustness by incorporating the diversity of building characteristics, occupant behaviors, environmental conditions, retrofit options, and evaluation criteria. The framework’s effectiveness is demonstrated through a case study in southern Michigan in the United States, which includes 63 one-story single-family houses, 121 two-story single-family houses, and 8 townhouses. The study identifies furnace retrofits as the most robust solution for the entire community, consistently achieving source energy reductions of 4.7 %–8.0 % and payback period of 10–20 years across various scenarios. These findings are consistent with previous research, indicating the framework’s potential for broader applications in optimizing community-scale residential energy retrofits.

Shu, Lei↗

Physically motivated analytical expression for the temperature dependence of the zero-field splitting of the nitrogen-vacancy center in diamond

The temperature dependence of the zero-field splitting (ZFS) between the | $m_s$ = 0 $\rangle$ and | $m_s$ = ±1 $\rangle$ levels of the nitrogen-vacancy (NV) center's electronic ground-state spin triplet can be used as a robust nanoscale thermometer in a broad range of environments. However, despite numerous measurements of this dependence in different temperature ranges, to our knowledge no analytical expression has been put forward that captures the scaling of the ZFS of the NV center across all relevant temperatures. Here we present a simple, analytical, and physically motivated expression for the temperature dependence of the NV center's ZFS that matches all experimental observations, in which the ZFS shifts in proportion to the occupation numbers of two representative phonon modes. In contrast to prior models our expression does not diverge outside the regions of fitting. In conclusion, we show that our model quantitatively matches experimental measurements of the ZFS from 15 to 500 K in single NV centers in ultrapure bulk diamond, and we compare our model and measurements to prior models and experimental data.

36 MATERIALS SCIENCE↗

Lighting application efficacy: A framework for holistically measuring lighting use in buildings

Lighting consumes significant energy in buildings, but current measurements of lighting efficiency are inadequate in capturing the spatial and temporal effectiveness of light. The most widely used lighting energy efficiency measure, luminous efficacy, quantifies the amount of light generated by individual light sources. While luminous efficacy provides manufacturers and designers with a useful metric for quantifying the energy efficiency of individual lighting devices, it does not fully address the use of lighting in architectural spaces. Instead, application efficacy, the relationship between the electrical power consumed by lighting hardware and the amount of light that contributes to the visual perception of building occupants, must be measured. Here, we propose a framework for calculating lighting application efficacy (LAE) based on the primary pathway of light in architectural settings: the generation and emission of light from a luminaire, the travel of the light throughout the space and into occupants’ eyes, and the process of visual perception. The LAE framework will include the development of computational methods for estimating the proportion of emitted light that is directed to task areas and areas corresponding to occupants’ visual fields using ray-tracing lighting design software. Future modeling and validation work will quantify energy efficiency of buildings.

Durmus, Dorukalp↗

Quantifying Occupant Health and Productivity for Deep Retrofits: Beyond Traditional IEQ Studies

As energy-efficiency standards for both new construction and existing building renovations become more stringent, further reductions become less tractable and more expensive. With increasing interest and rising investment in healthy built environments, integrating energy efficiency with improved occupant experience (i.e., health, comfort, and work performance) offers a new path to drive deep energy retrofits. However, the difficulty in quantifying and verifying health and productivity gains from building upgrades leads to lower valuation of human benefits in practice. Building codes and standards have progressive energy targets but often give minimum requirements to occupant health for factors such as ventilation and thermal comfort. State and federal laws in the United States that govern the energy service performance contract (ESPC) have no clear and consistent guidance on quantifying non-energy benefits and incorporating them into a formal cost-effectiveness analysis. This paper presents a methodology to measure a building’s potential performance improvement regarding occupant health based on existing evidence correlating IEQ to occupant outcomes. Health improvement measures are integrated with a building energy model to identify and measure the impact of holistic improvement strategies. The net present value of these measures is determined based on the investment costs required to attain those improvements, energy savings, and personnel gains. We will discuss results from one pilot building, which showed nearly $50 per square foot 20-year net present value using the integrated approach.

Keene, Kevin M.↗

Terra-Populus v0.1: A Python Library for LandScan High-Definition Population Analysis and Modeling

The terra-populus library is designed for use by the LandScan HD technical team, offering a streamlined set of tools for generating and updating LandScan HD datasets from foundational building-level data, referred to as 'molecules,' provided by the building-level attribution team. This document serves as the primary technical documentation for terra-populus. Version 0.1 of the library includes the core modeling components necessary for LandScan HD production. It enables the generation of the LandScan HD Baseline dataset as well as corresponding confidence measures for the occupancy rates used. Parameters have been included for incorporating damaged building indicators and changes in population, to faciliate the creation of rapid updates for LandScan HD. Future iterations of terra-populus will introduce tools for creating a confidence index, and quantifying and propagating uncertainty, facilitating the creation of probabilistic LandScan HD outputs. This report provides an overview of the tools available in the library and the corresponding code implementations. One of the key advancements implemented in terra-populus is a redefinition of the atomic modeling unit for LandScan HD. Traditionally, the LandScan HD vector analytical framework has generated population estimates at the building sub-component (molecule) level. However, terra-populus adopts a building-level modeling approach. This shift is an operational decision aimed at aligning LandScan HD outputs with confidence measures, which are computed and validated at the building level (confidence measures are not included in this version of terra-populus, aside from those associated with the occupancy rates). Additional advancements to the LandScan HD modeling, as implemented by terra-populus, include a minimum population value parameter and an auto assignment of building floor counts. The population minimum value was implemented to prevent buildings and subsequent LandScan HD pixels that contained small values that may not rasterize in production. An 'auto' value has been included as a method for dealing with buildings lacking floor count information, where it is the average floor count of all other buildings with a residential building use type tag. The logic behind this is to remain consistent with the current logic employed for dealing with building use type null instances, where a null use type is defaulted to residential since it is the most common building type. The auto logic is intended to apply the most common building floor count of the most common type of buildings. The tools provided in terra-populus represent a significant step forward in improving the efficiency, reproducibility, and transparency of the LandScan HD modeling process. As the library evolves, it will continue to serve as a foundational resource for high-resolution population modeling.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗