Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “numerical analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Numerical analysis of downhole heat exchanger designed for geothermal energy production

A traditional way of geothermal energy production implies hot brine extraction from the reservoir to a surface facility. This method is economically profitable only for high enthalpy reservoirs associated with shallow depths and high temperatures. The low enthalpy geothermal (LEG) projects are out of consideration due to the high cost of produced electric power related to expensive drilling, cost of the binary cycle system, and long term installation cost. This paper presents a new zero mass extraction method utilizing downhole heat exchanger (DHE) with no geo-fluid production to the surface. The well design stays as a single horizontal well with coupled production and injection sections. The brine pump is located between the sections providing hot brine circulation through the DHE. The coupled fluid flow and heat transfer mathematical model was developed and simulated using nodal analysis method. The LEG reservoir prototype located in South Louisiana was used to study several cases of the DHE lengths, inclination angles, reservoir permeabilities, and flow rates optimization. According to the analysis, the power unit is able to provide 160 kW of net electric power with CO2 working fluid circulating inside a single lateral well. Increasing the reservoir temperature and the number of laterals, the available power production rises up to 600 kW with an attractive electricity cost of $21.84/MWh at 7000 m well depth. This methods opens a new prospective for the depleted petroleum wells converting them to the electricity production units.

15 GEOTHERMAL ENERGY↗

Numerical Analysis of Wave Characteristics in a Methane-Oxygen Rotating Detonation Engine

Results from the simulation of the U.S. Air Force Research Laboratory methane–oxygen rotating detonation rocket engine from four independent research groups with different flow solvers underpredicted primary detonation wave speeds by a significant margin as compared to experimental values. In a simulation performed by the authors, the average calculated speed of the detonation waves was roughly [Formula: see text] as compared to the experimentally measured value of [Formula: see text]. This paper presents a detailed analysis of the wave characteristics in this simulation to provide a more quantitative understanding of the underlying factors leading to this discrepancy. The results show that weaker counter-rotating shock waves have a significant impact on the behavior of the primary detonation waves. The wave speed of the primary detonation wave is reduced by [Formula: see text] due to collisions with the counter-rotating waves. The presence of these counter-rotating waves also has a strong influence on the flow conditions upstream of the primary detonation waves, as well as the engine heat release rate. In addition, the flow properties upstream of the detonation wave vary significantly in the radial direction. Finally, the subfilter turbulent viscosity is shown to vary radially and with proximity to detonation waves.

Engineering↗

Measurement of Transport Properties of Woody Biomass Feedstock Particles Before and After Pyrolysis by Numerical Analysis of X-Ray Tomographic Reconstructions

Lignocellulosic biomass has a complex, species-specific microstructure that governs heat and mass transport during conversion processes. A quantitative understanding of the evolution of pore size and structure is critical to optimize conversion processes for biofuel and bio-based chemical production. Further, improving our understanding of the microstructure of biochar coproduct will accelerate development of its myriad applications. This work quantitatively compares the microstructural features and the anisotropic permeabilities of two woody feedstocks, red oak and Douglas fir, using X-ray computed tomography (XCT) before and after the feedstocks are subjected to pyrolysis. Quantitative analysis of the three-dimensional (3D) reconstructions allows for direct calculations of void fractions, pore size distributions and tortuosity factors. Next, 3D images are imported into an immersed boundary based finite volume solver to simulate gas flow through the porous structure and to directly calculate the principal permeabilities along longitudinal, radial, and tangential directions. The permeabilities of native biomass are seen to differ by three to four orders of magnitude in the different principal directions, but we find that this anisotropy is substantially reduced in the biochar formed during pyrolysis. The quantitative transport properties reported here enhance the ability of pyrolysis simulations to account for feedstock-specific effects and thereby provide a useful touchstone for the biorefining community.

09 BIOMASS FUELS↗

Performance of Closed Loop Venturi Aspirated Aeration System: Experimental Study and Numerical Analysis with Discrete Bubble Model

In wastewater treatment plants, aeration plays a significant role as it encourages aerobic respiration of microbes, which are necessary to break down carbonaceous matter in the waste stream. This process can account for the majority of energy use in wastewater treatment plants. The aeration process is also necessary in odor control in lagoons and in the aquaculture industry. Generally, the aeration process is accomplished with compressors or blowers which can be of low efficiency due to ideal gas laws. This study introduces the idea of increasing aeration efficiency by looping water from a reservoir through a piping network which includes a venturi aspirator at its inlet. For this purpose, an experimental study has been conducted in a laboratory setup with a pump which pulls water from a tank, passes it through a Venturi aspirator and a helical piping network intended to increase bubble residence time, before depositing it back into the bulk fluid tank. This same process is modeled computationally, using a discrete bubble method (DBM), with good agreement with experiments. The overall purpose here is to determine the optimal configurations for standard aeration efficiency (SAE) and the standard oxygen transfer rate (SOTR). A parametric study has been implemented using the DBM based on different hydraulic and flow parameters. The model is also used to predict the SAE of a hypothetical aeration system. Results indicate that it is possible to achieve SAE values in the range of surface aerators or submersed jet aerators using the proposed aeration system with less complex components, thereby decreasing overall costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical Analysis of the Transient Response of Advanced Thermal Protection Systems for Atmospheric Entry

Equations for the transfer of heat through thermal protection shields are derived in finite difference form. These equations are applicable to charring ablators, impregnated ceramics, subliming ablators, heat sinks, and insulating materials and have been programed for solution on a high-speed digital computer. In the program, thermal properties can be functions of temperature. Provision is made for analysis of heat shields subjected to simultaneous convective and radiative heat inputs. Some typical results are presented. Limited comparisons with experimental results are made.

THERMAL PROTECTION↗