Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “negative transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

241 records · Page 14

Thermal Vacuum and Vibration Testing of the Differential Thermal Expansion Thermal Switch

The Extended Stroke, Reverse Operation, Differential Thermal Expansion (DTE) Thermal Switch (TS) for Extreme Variable Environments uses materials with both positive and negative coefficients of thermal expansion (CTE) arranged in concentric cylinders so that the TS operates passively, opening a gap between interfaces to create a low thermal contact when cold, and closing the gap between interfaces to create a high thermal contact when hot. This paper details the testing of the TS at Marshall Space Flight Center (MSFC) including the vibration (vibe) test, pre-vibe thermal vacuum (t-vac) cycle test, post-vibe t-vac cycle test, and long duration t-vac cycle test. The data collected from the pre- and post-vibe tests are compared to show the impact of the vibe test on performance. The data collected from the long duration test is used to calculate the total thermal contact conductance through the TS interfaces for both ‘on’ (TS closed, during hot plateau) and ‘off’ (TS open, during cold plateau) configurations, and the turndown ratio is also calculated. Challenges experienced throughout testing are also discussed.

Thermal control technology↗

Winds, Water Budgets and Stable Isotopes in Tropical Cyclones using TRMM and QUICKSCAT

Water vapor is the most abundant greenhouse gas in the atmosphere. Changes in its concentration and distribution are controlled by the hydrologic cycle. Because of its capacity to absorb and emit long wave radiation, release latent heat during condensation in storms and reflect short wave radiation when clouds form it has a major impact on Global climate change. The stable isotope ratios of water are H20 H2l6O and H0 H2l6O. These ratios change whenever water undergoes a phase change. They also change in both rain and water vapor whenever an air parcel is exposed to rain. In addition the relative changes in the two ratios differ as a &nction of the relative humidity. In short, the stable isotope ratios in water vapor in the atmosphere contain an integrated history of the processes affecting the concentration and distribution of water vapor in the atmosphere. Therefore the measurement and interpretation of changes in these stable isotope ratios are a powerful tool matched by no other method in tracing the transport history of water in the atmosphere. Our initial studies under this grant focused on the changes of the stable isotope ratios of precipitation and water vapor in tropical cyclones. The changes in time and space were found to be very large and to trace the transport of water in the storms reflecting changes in basic structural features. Because the stable isotope ratios of rains from tropical cyclones are so low flooding associated with land falling tropical cyclones introduces a negative isotopic spike into the coastal surface waters. In addition the stable isotope ratios of water vapor in the vicinity of tropical cyclones is anomalously low. This suggests that carbonate shelled organisms such as ostracoda living in coastal waters have the potential to record the isotopic spike and thereby provide a long term record of tropical storm activity in sediment cores containing fossil shells. Likewise, tree rings in coastal environments offer a similar potential. We have analyzed the oxygen isotopic composition of ostrcoda shells formed in the floodwaters of Tropical Storm Allison (2001) and discovered the negative isotopic 1 16 spike. Because we had learned that storm activity has a major impact on the stable isotope ratios of water vapor in the tropics and sub-tropics we decided to analyze the isotopic compositions of water vapor in different locations in the tropics. We did this in Puerto Escondido, Mexico in July 1998, near Kwajalein Island in the Pacific in 1999 as part of a TRMM summer field program and in 2001 in Key West, Florida as part of the CAMEX 4 summer field program. Our isotopic studies along with our earlier tropical cyclone studies showed that the low isotopic ratios in water vapor induced by exposure to rains the storms persisted for 48 hours often far away from the original storm site. We also noted that positive isotopic spikes were introduced into atmospheric water vapor if winds were high and extensive sea spray was present. These findings have a significant impact on the interpretation of the stable isotope studies of tropical ice cores found in the high mountain regions of the tropics. The assumption made in interpreting the ice core record is that the source water vapor evaporated from the sea surface is in near isotopic equilibrium with the seawater and undergoes a decrease during its transport that reflects the change in temperature from the sea surface to the site of the ice core. Because an additional isotopic depletion occurs at the sea surface source area that depends on the intensity, duration and size of the tropical rain system the isotopic variations found in the ice cores must take into account changes in past storm activity in the tropics. These systems must be an important source of water vapor to the ice cores because they charge the troposphere with water vapor to a far greater vertical height than evaporation in quiescent regions. Finally, an interest in increased heat transfer in thnterior of tropical cyclones resulting from greater amounts of sea spray is a topic of considerable interest to the research community. Increases in sea spray may be related to rapid changes in the intensity of hurricanes, a feature of hurricanes that currently is very poorly forecast. Project CBLAST of the Hurricane Research Division of NOAA is an active program that uses P3 research aircraft to evaluate this problem. An instrument has been designed and built at the University of Houston that will be placed on the P3 research aircraft during the 2004 hurricane season. It continuously measures the salt content of rain in hurricanes. Changes in the salt content of the rains should reflect the abundance of sea spray at the sea surface. In this way maps of sea spray intensity in hurricanes may be forthcoming. This should help computer modelers who simulate hurricanes to better understand the potential of changes in sea spray to change the intensity of hurricanes. The cost of designing, building and installing this instrument was borne largely by funding from this NASA grant. A list of presentations at national meetings and publications that were as the result of funding from this NASA grant are found in the report.

Lawrence, James R.↗

Thermal Vacuum and Vibration Testing of the Differential Thermal Expansion Thermal Switch

The Extended Stroke, Reverse Operation, Differential Expansion Thermal Switch for Extreme Variable Environments uses materials with both positive and negative coefficients of thermal expansion (CTE) arranged in concentric cylinders so that the thermal switch (TS) operates passively, opening a gap between interfaces to create a low thermal contact when cold, and closing the gap between interfaces to create a high thermal contact when hot. This paper details the testing of the TS at Marshall Space Flight Center including the pre-vibe thermal vacuum cycle test, vibration test, post-vibe thermal vacuum cycle test, and long duration thermal vacuum cycle test. The pre- and post-vibe thermal cycle and the long duration cycle test tested to hot and cold plateau initial temperatures of 40 °C, and -173 °C, respectively. The pre- and post-vibe tests required plateau holds of at least 2 hours, whereas the long duration cycle test required plateau holds of at least 20 hours. The tests each used a rate of temperature change of < 2 °C/min when transitioning between plateaus. The data collected from each thermal test is compared to show the operation of the TS both before and after the vibration test to GEVS levels, and throughout the long duration cycle test. From the data collected, the total conductance through the TS interfaces is calculated for both on (TS closed – during hot plateau) and off (TS open – during cold plateau) configurations, and the turndown ratio is also calculated. Challenges and lessons learned from the testing are also discussed.

thermal control technology↗

A Comprehensive Characterization of Microorganisms and Allergens in Spacecraft Environment

The determination of risk from infectious disease during long-duration missions is composed of several factors including the concentration and the characteristics of the infectious agent. Thus, a thorough knowledge of the microorganisms aboard spacecraft is essential in mitigating infectious disease risk to the crew. While stringent steps are taken to minimize the transfer of potential pathogens to spacecraft, several medically significant organisms have been isolated from both the Mir and International Space Station (ISS). Historically, the method for isolation and identification of microorganisms from spacecraft environmental samples depended upon their growth on culture media. Unfortunately, only a fraction of the organisms may grow on a culture medium, potentially omitting those microorganisms whose nutritional and physical requirements for growth are not met. Thus, several pathogens may not have been detected, such as Legionella pneumophila, the etiological agent of Legionnaire s disease. We hypothesize that environmental analysis using non-culture-based technologies will reveal microorganisms, allergens, and microbial toxins not previously reported in spacecraft, allowing for a more complete health assessment. The development of techniques for this flight experiment, operationally named SWAB, has already provided advances in NASA laboratory processes and beneficial information toward human health risk assessment. The translation of 16S ribosomal DNA sequencing for the identification of bacteria from the SWAB experiment to nominal operations has increased bacterial speciation of environmental isolates from previous flights three fold compared to previous conventional methodology. The incorporation of molecular-based DNA fingerprinting using repetitive sequence-based polymerase chain reaction (rep-PCR) into the capabilities of the laboratory has provided a methodology to track microorganisms between crewmembers and their environment. Both 16S ribosomal DNA identification and bacterial fingerprinting have improved NASA s capability to better understand spacecraft environments and determine the source of contamination events. Preflight sampling has been completed for air, surface, and water samples. In-flight sample collection has been completed for a total of 8 air and surface sample collection sessions. In-flight hardware has performed well and the surface sampling device received positive feedback from the crew for its ease of use. While processing and analysis continue for these samples, early results have begun to provide information on the spacecraft environment. Using a method called Denaturing Gradient Gel Electrophoresis (DGGE), several air and samples were evaluated to determine the types of organisms that were present. Using only molecular techniques, DGGE does not depend on any microbial growth on culture media, allowing a more comprehensive assessment of the spacecraft interior. Preliminary results have identified several microorganisms that would not have been isolated using current technology, though none of these organisms would be considered medically significant. Interestingly, the isolation of Gram negative organisms is greater using DGGE than conventional media based isolation. The cause of this finding is unclear, though it may be the result of the technique s ability to isolate both viable and non-viable bacteria. The next phase of the SWAB sample analysis is the use of quantitative polymerase chain reaction (QPCR) to look for specific medically significant organisms. While not as broad as DGGE, QPCR is much more sensitive and may reveal findings that were not seen during the initial evaluation. Together, this information will lead toward an accurate microbial risk assessment to help set flight requirements to protect the safety, health, and performance of the crew.

Castro, V.A.↗

Transition in Turbine Flows

We have further developed our capabilities to analyze transition in turbine boundary layers from first principles by integrating the nonlinear parabolized stability equations (PSE) with improved initial and boundary conditions. With modified iteration schemes, we are able to proceed deeper into the transition region where skin friction coefficient and heat transfer coefficient significantly increase. Initial and boundary conditions at elevated turbulence levels can be derived by receptivity analysis. Test runs for ERCOFTAC test case T3A at 2.4\% turbulence level provide results in good agreement with the experimental data. The sharper minimum of the skin coefficient also shown by DNS results is likely due to the missing intermittency. The method has been applied to various experimentally studied turbine blades (UTRC, VKI, Zierke, Langston, Hippensteele, and others). The PSE results, though physically reasonable, do not agree as well as expected with the experimental findings. We have, therefore, performed an extensive search for the reasons of the seemingly systematic deviations. A first source of uncertainty has been found in the often insufficient documentation of the experiments (e.g. on blockage by end-wall boundary layers). However, variation of the relevant parameters does not lead to more satisfactory agreement. A second reason has been found in the "standard procedure" which considers a 2D flow at midspan and uses a panel code and subsequent boundary-layer code to obtain the laminar basic flow for the transition analysis. Comparison with the pressure distribution obtained with a 3D design code (RVC3D) shows significant three-dimensionality of the flow (e.g. in the UTRC experiments). The spanwise variation has been neglected in our original PSE code. To overcome this problem, we have developed the PSE/3D for fully 3D boundary layers to account for streamwise and spanwise variations. Since the design code does not provide the boundary-layer flow with sufficient resolution, we have generated the Euler solution and employed a 3D boundary-layer code to obtain the viscous basic flow. Although only the linear stability level of PSE/3D has been implemented so far, the discrepancies with the experiments change but do not disappear. We still find deviations between the computed and experimental variations of C(sub f), and St along the blade for laminar flow. The main reason can be seen by comparing the solution of the boundary-layer code with the viscous results of the design code. The conventional boundary-layer solution exhibits an asymptotic behavior appropriate in external aerodynamics but does not match the steep gradients of the inviscid flow through the passage and consequently provides biased results for C(sub f), and St. An attempt is currently being made to correct this deficiency. Before attempting to perform the transition analysis for the viscous flow provided by the design code, we have analyzed the implementation and "best possible" results. Code and results exhibit flaws that may negatively affect the design and are intolerable for transition analysis. Therefore, we have decided to develop a new code to obtain a reliable basis for stability and transition studies. We expect to report improved results by the time of the meeting.

Herbert, Thorwald↗

Implementation of A New Microwave Scattering Database and A Forward Model for Active Microwave Sensors in CRTM

Radiative transfer models are extensively used for the assimilation of satellite observations into NWP models as well as retrieving geophysical products from satellite measurements. CRTM is a community model developed by NOAA JCSDA and widely used for different purposes requiring RT calculations. CRTM requires bulk scattering lookup tables in order to perform all-sky RT calculations. However, the current CRTM lookup tables for microwave frequencies were generated based on the Mie theory by assuming spherical frozen particles. The scattering lookup tables generated using the DDA technique has shown to largely improve the RT scattering calculations in the MW region. This presentation targets (i) the implementation and validation of a DDA database that was originally developed for the ARTS RT model into CRTM, and (ii) developing the CRTM active sensor module that takes advantage of the backscattering coefficients computed using the DDA method. The DDA database only provides single scattering properties of different habits, while CRTM requires bulk scattering properties. The CRTM cloud coefficients were previously generated based on the effective radius for representing the size of the particles. However, effective radius is neither measurable nor provided by the NWP models, thus need to be estimated from other geophysical variables such as water content. Therefore, in addition to calculating the CRTM bulk scattering properties from the DDA single scattering database, the CRTM was also largely modified to use cloud water content (kg.m-3), instead of effective radius, for performing the interpolation over size/mass of the particles. CRTM already requires water content as input, thus no extra variables are required for performing scattering calculations using the new ARTS DDA database. The CRTM scattering modules search for effective radius in cloud coefficient files and will use the cloud water content if the effective radius dimension is not found in the cloud coefficient files. Figure 1 shows the CRTM simulated brightness temperatures computed using different cloud coefficients versus ATMS observed values over Hurricane Irma on September 7, 2017 at 18:00 UTC. We used all the cloud water content values included in ERA5 with default CRTM/DDA habits for water, rain, snow, ice, hail, and graupel. ERA5 does not provide separate water content values for ice, hail, and graupel, thus the ice water content values were divided between ice, hail, and graupel clouds similar to what was explained in the previous section. In channels with a frequency lower than 90 GHz, emission from water and rain clouds can compensate for cloud scattering so that cloud contaminated Tbs are larger than corresponding clear sky Tbs. The DDA simulations for channels 1-7 largely perform better than the Mie simulations. The DDA simulations show a mix of small negative and positive simulated minus observed values, while the Mie results show large negative biases. The weighting functions for some of the ATMS temperature sounding channels (channels 9-15) peak mostly above the clouds, therefore the measured Tbs become less sensitive to clouds so that the results of both Mie and DDA become very similar. The Mie lookup tables generate excessive scattering for channel 16, but not enough scattering for the water vapor channels. In the specific case of Hurricane Maria, the DDA lookup tables do not generate enough scattering for channel 16, but the DDA results are much more consistent with observations for water vapor channels than for channel 16. It should be noted that the results may vary if we use other habits to represent snow, hail, and graupel in the DDA simulations. Although these results clearly show the advantage of the DDA database over the Mie dataset, different error sources such as error in the observations, displacement of clouds in the ERA5 reanalysis, and also lack of convective clouds or in general errors in the input atmospheric and cloud profiles contribute to the differences between the simulated and observed values. Aside from the improvements in the simulations, a major advantage of the new dataset is a large number of habits that can be used to tune the data assimilation systems to perform well in different weather conditions.

Isaac Moradi↗

Microbial Monitoring of New Cleanrooms Used to Curate Astrobiologically Relevant Asteroid Samples from Bennu and Ryugu

Introduction: NASA has constructed two new cleanrooms to house materials from the OSRIS-REx and Hayabusa2 missions to the asteroids Ryugu (162173) and Bennu (101955), respectively. In accordance with standard astromaterials curation practices, these cleanrooms will be monitored for particulate contamination and maintained to ISO 5 equivalent standards1. Since the samples in these collections are expected to contain prebiotic organic compounds that may help explain the origin of life on Earth, these labs will also be monitored for organic and biological contamination2. Samples from Ryugu arrived on Earth in December, 2020. After basic characterization in Japan, NASA received a subset of these samples at the astromaterials curation facility in Houston in December of 2021. OSIRIS-REx is expected to return samples in September, 2023. Here we present preliminary microbial monitoring results from monthly monitoring of these new labs and the connected microtomy and staging areas that support them, as they are being commissioned. We also compare these results to baseline values for other astromaterials curation labs. We will also briefly describe additional cleaning efforts employed to reduce the bioburden in these new cleanrooms. Methods: Microbial samples were collected from surfaces using a dry macrofoam swab (Puritan Brand 2518051PFRNDFD). Swabs were also opened in the lab but not touched to any surfaces to function as negative controls. Samples and controls were processed inside a class II biosafety cabinet to avoid inadvertent cross contamination. The swabs were suspended in 15 ml of PBS (Phosphate Buffered Saline) and vortexed for 20 seconds to remove cells from the swab surface. The PBS was used to inoculate Petri dishes filled with TSA (Tryptic Soy Agar), Blood Agar, or Reasoners 2 agar to check for microbial growth. Each plate was inoculated with 0.1 ml of PBS. The TSA and blood agar plates were incubated at 35˚C and the Reasoners 2 agar plates were incubated at 25˚C for seven days. Petri dishes filled with Potato dextrose agar, Saboraud dextrose agar, or Saboraud dextrose agar with 0.1 mg/ml of chloramphenicol, an antibiotic, were used to check for fungal growth. These plates were inoculated with 0.3 ml of PBS and incubated at 30˚C. The remaining PBS was frozen at -80 ˚C for DNA sequencing. After incubation, isolates were counted and reisolated for identification. Isolates were identified using the VITEK23 system or by sequencing a portion of the 16S rRNA gene for bacteria or the ribosomal internal transcribed spacer (ITS) for fungi. Sequencing was performed with an ABI 3500 Sanger sequencer. Results: During our initial sampling, six of the seven sites sampled (86%) displayed bacterial or fungal growth. Samples collected from the staging areas and microtomy labs are not included in this calculation since those areas are maintained at a lower ISO 7 equivalent cleanliness standard. A month later, only three of the seven sites (43%) displayed bacterial growth. No fungal growth was detected in the second sampling. Since new equipment had been introduced to the Hayabusa2 lab since the first round of sampling, an additional three sampling sites were included in the second round of sampling. None of these sites displayed microbial growth. These sites will be included in all future sampling efforts. Bacterial isolates have been identified from the following genera at multiple time points: Micrococcus, Staphylococcus, and Bacillus. Isolates from the genera: Microbacterium, Nocardioides, Methylocystis, and Microvirga were identified in the initial sampling, but were not present at later time points. Identification of fungal isolates is in progress. Results are summarized in Table 1. Discussion: The recovery rate or percentage of positive samples4 was initially 86%, which is higher than the median recovery rate for comparable ISO 5 equivalent curation labs like Stardust (33%), Hayabusa (33%), and Cosmic Dust (50%). However, after a month of operation, the recovery rate for these same sites decreased to 43%, which is similar to what we observe in comparable curation cleanrooms with no microbial control requirements. Adding in the new sampling sites further decreases the recovery rate to 30%. With the reduction in recovery rate, we also observed a decrease in microbial diversity. At the first time point, we observed at least 10 different bacterial species and at least two different fungi. This is a higher diversity than the median values for comparable ISO 5 equivalent labs (2-4 isolates per sampling event). After the second sampling, we observed at least 4 bacterial species and no fungi, which is more consistent with comparable labs. We expect the recovery rate and diversity in both labs to continue to decrease as routine operation continues. We will use ultrapure hydrogen peroxide to disinfect equipment and work areas prior to opening any sample containers. Most of the bacterial and fungal isolates were detected on samples from the cleanroom floors. This is consistent with baseline results from other curation labs. Organisms from the genera Bacillus, Staphylococcus, and Micrococcus that were repeatedly detected are common in cleanrooms and on human skin5,6. These organisms are generally thought to be introduced when people enter the cleanroom. Microbacterium, Nocardioides, and Microvirga have also previously been identified in astromaterials cleanrooms, but not as frequently as Bacillus, Staphylococcus, and Micrococcus. Methylocystis is a novel genus in the astromaterials cleanrooms, but it was identified with low accuracy (93% match in the sequenced region of the 16S rRNA gene) and further work is needed to confirm this identification. Microbacterium is a diverse genus with isolates identified from terrestrial and aquatic sediments. Some species of Microbacterium are capable of degrading complex organic compounds found in crude oil. The presence of these bacteria in the OSIRIS REx and Hayabusa2 cleanrooms should be closely monitored. Methylocystis is a genus of methanotrophic bacteria capable of oxidizing methane. If this identification proves to be correct and it is detected again, it should be closely monitored as well. Under nominal operating conditions, samples should not ever encounter the cleanroom floor or other high traffic areas. If we observe an increase in the bioburden in sensitive work areas that appears to be influenced by organism transfer from high traffic areas like the floors, we can employ additional hydrogen peroxide treatments to disinfect high traffic areas. Routine microbial monitoring of these labs will ensure that NASA’s astromaterials collections remain pristine and useful for scientific study. Table 1. Sampling Locations and Colony Counts Bacterial CFUa Fungal CFU Bacterial CFU Fungal CFU Lab - Location 11/2/2021 11/2/2021 12/13/2021 12/13/2021 H2b-Floor 4 8 1 0 H2-staging pass through 3 0 0 0 H2-microtomy pass through TNTCc 0 0 0 H2 Microscope 1 NA NA 0 0 H2 Microscope 2 NA NA 0 0 H2-Table NA NA 0 0 OREXd- microtomy pass through 0 0 6 0 OREX – Anteroom pass through 0 0 0 0 OREX – Floor 1 2 0 0 OREX Witness Foil Table 3 0 1 0 Staging-Floor 16 0 15 0 Microtomy-Floor 3 0 2 0 a: CFU = Colony Forming Unit b: H2 = Hayabusa2 Lab c: TNTC = too numerous to count d: OREX = OSIRIS-REx Lab References: 1. ISO 14644-1:2015 - Cleanrooms and associated controlled environments -- Part 1: Classification of air cleanliness by particle concentration. 37 (2015). 2. McCubbin, F. M. et al. Space Sci Rev 215, (2019). 3. Pincus, D. H. Encyclopedia of Rapid Microbiological Methods (2005). 4. The United States Pharmacopeial Convention. USP General Chapter <1116> 17, 784–794 (2013). 5. Sheraba, N. S., Yassin, A. S. & Amin, M. BMC Research Notes 3, 278 (2010). 6. Utescher, C. L. de A., Franzolin, M. R., Trabulsi, L. R. & Gambale, V. Brazilian Journal of Microbiology 38, 710–716 (2007).

A B Regberg↗