Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “moose framework”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

236 records · Page 14

The Monolithic Heat Pipe Microreactor Reference Plant Model

This work introduces a reference plant model for a generic monolithic heat-pipe-cooled microreactor. The model will serve as a springboard to develop future evaluation models in the licensing process of similar microreactor designs at the U.S. Nuclear Regulatory Commission. This model has been developed with the Comprehensive Reactor Analysis Bundle and its specifications are based on open literature publications for the eVinci TM design. BlueCRAB is the U.S. Nu- clear Regulatory Commission non-light-water reactor analysis system based on the Multiphysics Object-Oriented Simulation Environment framework, which can couple the Griffin, BISON, and Sockeye applications to resolve the various physics that are essential for the safety analysis of this type of reactor system. The core specifications includes tristructural isotropic fuel, graphite monolith, graphite reflectors, and drums composed of graphite and B 4 C. No moderator or burnable poison pins are used in the design. The fuel enrichment is reduced to control excess reactivity in the core. This core design is not optimized and only serves for testing purposes, since the primary objective of this work is to exercise the multiphysics coupling for this type of reactor system. A three dimensional (3D) core heterogeneous Griffin discrete ordinates (SN) transport model allows the precise calculation of the flux distribution and pin powers. Griffin transfers the power density distribution and obtains a temperature distribution to and from BISON. The BISON model com- putes the 3D core temperature distribution and is coupled to 876 Sockeye subapplications running a heat pipe model. This 3D conduction model is coupled to the various heat pipes via heat flux boundary conditions. The model includes a small gap between the heat pipe and the monolith. Convective heat transfer boundaries with either ambient temperature or condenser temperature as heat sinks are imposed at the model boundaries. The 2D Sockeye heat pipe model uses a vapor- only methodology, which provides the needed resolution for transient calculations and allows the determination of various heat pipe limits. This approach is superior to the superconductor model traditionally used in steady-state calculations. BlueCRAB computes steady-state power and temperature distributions that serve as the initial condition for a loss-of-heat-sink transient simulation. The steady-state results show significant peaking due to the position of the control drum, but this is a characteristic of the particular design used, which is not optimized at this stage. The transient results show the reactor power slowly stabilizing towards a 3% power level after the partial loss of secondary heat removal. Several recriticalities are observed due to cooling through the secondary system but the reactor is self-stabilizing and behaves as expected.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗