Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “model testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Studying Corrosion Using Miniaturized Particle Attached Working Electrodes and the Nafion Membrane

We developed a new approach to attach particles onto a conductive layer as a working electrode (WE) in a microfluidic electrochemical cell with three electrodes. Nafion, an efficient proton transfer molecule, is used to form a thin protection layer to secure particle electrodes. Spin coating is used to develop a thin and even layer of Nafion membrane. The effects of Nafion (5 wt% 20 wt%) and spinning rates were evaluated using multiple sets of replicates. The electrochemical performance of various devices was demonstrated. Additionally, the electrochemical performance of the devices is used to select and optimize fabrication conditions. The results show that a higher spinning rate and a lower Nafion concentration (5 wt%) induce a better performance, using cerium oxide (CeO2) particles as a testing model. The WE surfaces were characterized using atomic force microscopy (AFM), scanning electron microscopy-focused ion beam (SEM-FIB), time-of-flight secondary ion mass spectrometry (ToF-SIMS), and X-ray photoelectron spectroscopy (XPS). The comparison between the pristine and corroded WE surfaces shows that Nafion is redistributed after potential is applied. Our results verify that Nafion membrane offers a reliable means to secure particles onto electrodes. Furthermore, the electrochemical performance is reliable and reproducible. Thus, this approach provides a new way to study more complex and challenging particles, such as uranium oxide, in the future.

42 ENGINEERING↗

TESS Discovery of a Super-Earth and Three Sub-Neptunes Hosted by the Bright, Sun-like Star HD 108236

We report the discovery and validation of four extrasolar planets hosted by the nearby, bright, Sun-like (G3V) star HD 108236 using data from the Transiting Exoplanet Survey Satellite (TESS). We present transit photometry, reconnaissance, and precise Doppler spectroscopy, as well as high-resolution imaging, to validate the planetary nature of the objects transiting HD 108236, also known as the TESS Object of Interest (TOI) 1233. The innermost planet is a possibly rocky super-Earth with a period of 3.79523{sub −0.00044}{sup +0.00047} days and has a radius of 1.586 ± 0.098 R {sub ⊕}. The outer planets are sub-Neptunes, with potential gaseous envelopes, having radii of 2.068{sub −0.091}{sup +0.10} R {sub ⊕}, 2.72 ± 0.11 R {sub ⊕}, and 3.12{sub −0.12}{sup +0.13} R {sub ⊕} and periods of 6.20370{sub −0.00052}{sup +0.00064} days, 14.17555{sub −0.0011}{sup +0.00099} days, and 19.5917{sub −0.0020}{sup +0.0022} days, respectively. With V and K {sub s} magnitudes of 9.2 and 7.6, respectively, the bright host star makes the transiting planets favorable targets for mass measurements and, potentially, for atmospheric characterization via transmission spectroscopy. HD 108236 is the brightest Sun-like star in the visual (V) band known to host four or more transiting exoplanets. The discovered planets span a broad range of planetary radii and equilibrium temperatures and share a common history of insolation from a Sun-like star (R {sub ⋆} = 0.888 ± 0.017 R {sub ⊙}, T {sub eff} = 5730 ± 50 K), making HD 108236 an exciting, opportune cosmic laboratory for testing models of planet formation and evolution.

47 OTHER INSTRUMENTATION↗

Merged Observatory Data Files (MODFs): an integrated observational data product supporting process-oriented investigations and diagnostics

A large and ever-growing body of geophysical information is measured in campaigns and at specialized observatories as a part of scientific expeditions and experiments. These collections of observed data include many essential climate variables (as defined by the Global Climate Observing System) but are often distinguished by a wide range of additional non-routine measurements that are designed to not only document the state of the environment but also the drivers that contribute to that state. These field data are used not only to further understand environmental processes through observation-based studies but also to provide baseline data to test model performance and to codify understanding to improve predictive capabilities. To address the considerable barriers and difficulty in utilizing these diverse and complex data for observation–model research, the Merged Observatory Data File (MODF) concept has been developed. A MODF combines measurements from multiple instruments into a single file that complies with well-established data format and metadata practices and has been designed to parallel the development of corresponding Merged Model Data Files (MMDFs). Using the MODF and MMDF protocols will facilitate the evolution of model intercomparison projects into model intercomparison and improvement projects by putting observation and model data “on the same page” in a timely manner. The MODF concept was developed especially for weather forecast model studies in the Arctic. The surprisingly complex process of implementing MODFs in that context refined the concept itself. Thus, this article explains the concept of MODFs by providing details on the issues that were revealed and resolved during that first specific implementation. Detailed instructions are provided on how to make MODFs, and this article can be considered a MODF creation manual.

54 ENVIRONMENTAL SCIENCES↗

Wind Energy Accomplishments and Year-End Performance Report: Fiscal Year 2022

Four decades ago, construction was just beginning on experimental turbines at the National Wind Technology Center (NWTC). Today, the U.S. Department of Energy's (DOE's) National Renewable Energy Laboratory (NREL) facility is the centerpiece of the laboratory's Flatirons Campus, a world-class hub for renewable energy research. The nation's shift to 100% clean electricity by 2035 will require a mix of renewable energy sources and strategies - and together, wind and solar energy could account for 60% to 80% of that clean energy resource. In Fiscal Year (FY) 2022, NREL scientists, engineers, and analysts contributed to these visionary goals through their wind energy research. As wind innovations push into new areas, NREL continues to play a vital role in advancing technology and addressing deployment barriers in pursuit of more efficient, reliable, and predictable wind energy systems. FY 2022 wind research and development explored the potential for dramatic growth in land-based systems, the launch of the nation's first commercial-scale offshore installations, and transmission infrastructure buildout. Land-based wind energy is one of the most cost-effective electricity supply options - but utility-scale deployment will require up to 10 times the current number of turbines. An NREL plan addressed this need to accelerate U.S. wind technology rollout at distributed and utility scales. Another project conducted by NREL and the Pacific Northwest National Laboratory (PNNL) helps position the nation's first major offshore wind corridor for success. The WETO-funded Atlantic Offshore Wind Transmission Study is evaluating options for balancing electricity supply and demand, while supporting resilience of the grid and marine industries. WETO, NREL, and other partners are working to enable the enormous supply chain and workforce changes the U.S. wind energy industry will need to meet net-zero-carbon-emissions targets. As part of a seminal series of DOE-funded supply chain studies, NREL analysts reported on the trade-offs involved in manufacturing large volumes of wind technologies, while addressing cost, workforce, and logistics issues. All of this research is supported by NREL's outstanding research teams, tools, data, and facilities. A WETO-funded international wind energy field campaign, the American WAKE experimeNt (AWAKEN), has brought together experts from NREL, PNNL, and Sandia National Laboratories to create the world's most comprehensive set of high-resolution data on wind energy atmospheric phenomenon. This study could lead to more accurate predictions of losses from turbine-to-turbine wake interactions, eventually helping wind plants capture more energy and operators save millions of dollars. In addition, NREL researchers developed testing, modeling, and analysis tools to improve the security of power grids by identifying wind power plant dynamic stability problems. A new Stochastic Soaring Raptor Simulator (SSRS) protects golden eagles from turbine encounters by predicting flight paths. This report provides more detail on these top achievements and other accomplishments made by NREL and its partners during FY 2022 (between October 1, 2021, and September 30, 2022).

accomplishments↗

Developing a Composite Vacuum Insulated Panel (VIP) Insulation/Vinyl Siding Composite Technology for Retrofitting Residential Walls

This paper reports on a project that has attempted to seize on an opportunity to take a giant leap forward in commercializing a technology that would address a key opportunity to achieve energy savings in the existing residential housing stock. It is typically very difficult to increase the R-value of the walls in existing residential housing as doing so from the inside is disruptive and there have not been good solutions to increase thermal envelope performance from the exterior through adding continuous insulation due to the additional work required to fit existing architectural features to the new wall thickness and to reclad the façade. A high thermal resistivity or R-value per inch product that can be used in these applications offers an excellent solution.This paper summarizes a three-year research project to a produce vacuum insulated panel (VIP)/vinyl siding that would have sufficient R-value to meet the continuous insulation requirements of the 2018 International Energy Conservation Code (IECC, 2018) in all climate zones and has a much thinner profile that will facilitate its application to existing residential homes without the need for expensive retrimming of the architectural details. The paper will supply information on the development of the technology, its thermal modelling, testing, voice of user sessions to solicit input from architects, designers, manufacturers, contractors, and installers, and a techno-economic analysis to gauge its competitiveness with existing product options.

Desjarlais, Andre Omer↗

Design of a Two-Body Wave Energy Converter Featuring Controllable Geometry: Preprint

While the field of wave energy has been the subject of numerical simulation, scale model testing, and precommercial project testing for decades, wave energy technologies remain in the early stages of development and must continuing proving themselves as a promising modern renewable energy field. A wave energy converter (WEC) concept, currently being explored, is hoping to add an extra control option to WEC design is the variable-geometry WEC (VGWEC). These VGWECs attempt to incorporate controllable geometric features to adjust the floating body hydrodynamics to favor either power absorption, load shedding, or other operational goals. These variable geometry components have been proposed to be controlled on a sea-state-to-sea-state or wave-to-wave time scale depending on the force (or toque) and bandwidth limitations of the actuators required to manipulate just the controllable geometric hull features. The opportunities of having control over both the WEC geometry components and the power-take-off (PTO) have the potential to improve overall system performance and reliability if a cost-effective solution can be found for a given WEC architecture. This paper will present the recent developments and results of a VGWEC concept that incorporates variable geometry modules into a two-body WEC. In the proposed VGWEC concept, the variable geometry modules consist of air inflatable bags in the surface float and a water inflatable ring in the subsurface body. The surface float is tethered directly to the subsurface body through tether lines each connected to a separate PTO. Adjusting the geometry of both the surface and subsurface bodies along with the PTO coefficients can be shown to maximize power in design sea states while reducing motion response and PTO forces when transitioning to sea states where rated power is reached and load shedding is prioritized in hopes of increasing the sea state operational map.

geometry control↗

FY23 status report on the development of new ASME Section III, Division 5 Class B rules

This report summarizes the work done in Fiscal Year 2023 on the development of the new American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section III, Division 5, Class B rules to address the gaps identified for high temperature reactor designs. The summary of the design-by-analysis strain limit evaluation and creep-fatigue damage assessment is presented. The proposed design-by-analysis creep-fatigue damage calculation approach uses a new elastic follow-up-based Isochronous Stress Strain Curve stress relaxation procedure. This approach captures the elastic follow-up generated due to interactions of components with adjacent components, supports, and other connections in the power plant. A set of sample problems are selected to validate the proposed design-by-analysis rules for creep-fatigue damage assessment. The proposed Class B rules are evaluated against the Class A elastic design rules, and the experimental data obtained from a family of Simplified Model Test based key-feature test results. The proposed Class B creep-fatigue damage assessment methodology yields conservative design cycles estimates compared to the experimental results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Developing a Composite Vacuum Insulated Panel (VIP) Insulation/Vinyl Siding Composite Technology for Retrofitting Residential Walls

This paper reports on a project that has attempted to seize on an opportunity to take a giant leap forward in commercializing a technology that would address a key opportunity to achieve energy savings in the existing residential housing stock. It is typically very difficult to increase the R-value of the walls in existing residential housing as doing so from the inside is disruptive and there have not been good solutions to increase thermal envelope performance from the exterior through adding continuous insulation due to the additional work required to fit existing architectural features to the new wall thickness and to reclad the facade. A high thermal resistivity or R-value per inch product that can be used in these applications offers an excellent solution. This paper summarizes a three-year research project to a produce vacuum insulated panel (VIP)/vinyl siding that would have sufficient R-value to meet the continuous insulation requirements of the 2018 International Energy Conservation Code (IECC, 2018) in all climate zones and has a much thinner profile that will facilitate its application to existing residential homes without the need for expensive retrimming of the architectural details. The paper will supply information on the development of the technology, its thermal modelling, testing, voice of user sessions to solicit input from architects, designers, manufacturers, contractors, and installers, and a techno-economic analysis to gauge its competitiveness with existing product options.

Desjarlais, Andre↗

Development of a Light-Trapping, Planar-Cavity Receiver for Enclosed Solar Particle Heating

Concentrating solar thermal power (CSP) technology development has recently focused on high efficiency power cycles and chemical reactions that require high operating temperatures. An increase in receiver operating temperatures relative to current commercial CSP technology is necessary to support more efficient, high temperature power cycles or thermochemical processes. Solar receivers operating with heat transfer media temperatures >700 degrees C face various challenges including thermal performance, scalability, thermal-mechanical issues, and receiver service life. In addition, heat transfer media selection for high-temperature processes has been moving towards inert solid particles in Gen3 CSP, and reactive solid media and/or gases in solar thermochemical processes. To overcome the shortcomings and limitations of conventional designs for molten salt or particle receivers and receiver reactors, we introduce a unique light-trapping, planar cavity receiver (LTPCR) configuration and will present the current development progresses to demonstrate receiver feasibility through modeling, testing, and prototype demonstration.

ENGINEERING,SOLAR ENERGY↗

DESI DR2 Reference Mocks: Clustering results from UCHUU ELGs and QSOs

High-redshift galaxy clustering provides a powerful probe of the growth of structure, testing models of dark matter, dark energy, and galaxy formation during the epoch when the Universe was rapidly evolving. Emission line galaxies (ELGs) and quasars (QSOs) are used as tracers of dark matter by the Dark Energy Spectroscopic Instrument (DESI) to probe this redshift regime. We present results from ELG and QSO mock catalogs created from the Uchuu N-body simulation and tuned to DESI Data Release 2 (DR2) clustering. Employing a modified subhalo abundance matching (SHAM) technique, we populate Uchuu halos and subhalos with QSOs between 0.8 < z < 2.1. For ELGs, we modify this method to select satellite galaxies with low velocities relative to their associated central halos, and populate a separate set of Uchuu halos and subhalos with ELGs between 0.8 < z < 1.6. In this paper, we reproduce the redshift evolution of number density and clustering statistics across the fitted range of scales. We also measure the large-scale clustering bias of both the data and mock samples. These results improve simulated lightcone construction from cosmological models and enhance our understanding of the galaxy-halo connection.

Vaisakh, R. [Southern Methodist U.] (ORCID:0009000↗

Cloud-based implementation of white-box model predictive control for a GEOTABS office building: A field test demonstration

Model predictive control (MPC) has been proven in simulations and pilot case studies to be a superior control strategy for large buildings. MPC can utilize the weather and occupancy schedule forecasts, together with the system model, to predict the future thermal behavior of the building and minimize the overall energy use and maximize thermal comfort. However, these advantages come with the cost of increased modeling effort, computational demands, communication infrastructure, and commissioning efforts. Thus a typical approach is to, often rapidly, simplify the building modeling and MPC optimization problem while paying a price of not reaching the full performance potential. It has been shown that by employing accurate physics-based models, MPC performance can be notably increased closer to its theoretical performance bound. However, implementation of such high-fidelity MPC in real buildings remains a challenge, resulting in a lack of successful field test studies. This work presents the methodology and field test demonstration of a computationally efficient implementation of the white-box MPC in an office building in Belgium. The detailed model of the building is based on first-principle physical equations. The deployment and supervision of MPC operation in a practical setting are supported by an automated cloud-based communication infrastructure. The motivating factor behind the cloud-based architecture is its compatibility with a commercially appealing control as a service concept. The building is equipped with a ground source heat pump (GSHP) and thermally activated building structures (TABS), where the combination of both is also known as GEOTABS. From a control perspective, GEOTABS buildings are particularly challenging systems due to large scale, complex heating, ventilation and air conditioning (HVAC) system, and slow dynamics with time delays. On the other hand, there is an increased potential for energy savings due to the high thermal mass, which acts as thermal storage. The MPC operation is demonstrated during the challenging transient seasons (switching between heating and cooling), and its performance is compared to a traditional rule-based controller (RBC). We provide a proof of concept of real MPC operation for the most difficult seasons with notable GSHP energy use savings equal to 53.5% and thermal comfort improvement by 36.9%. Other MPC applications found in the literature describe tests for only cooling or only heating, and up to now only for a black-box or a grey-box approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detecting shearless phase-space transport barriers in global gyrokinetic turbulence simulations with test particle map models

In magnetically confined fusion plasmas, the role played by zonal 𝐸 x 𝐵 flow shear layers in the suppression of turbulent transport is relatively well understood. However, less is understood about the role played by the weak shear regions that arise in the non-monotonic radial electric field profiles often associated with these shear layers. In electrostatic simulations from the global total-𝑓 gyrokinetic particle-in-cell code XGC, we demonstrate how shearless regions with non-zero flow curvature form zonal ‘jets’ that, in conjunction with neighbouring regions of shear, can act as robust barriers to particle transport and turbulence spreading. By isolating quasi-coherent fluctuations radially localised to the zonal jets, we construct a map model for the Lagrangian dynamics of gyrokinetic test particles in the presence of drift waves. We identify the presence of shearless invariant tori in this model and verify that these tori act as partial phase-space transport barriers in the simulations. We also demonstrate how avalanches impinging on these shearless tori cause eddy detachment events that form ‘cold/warm core ring’ structures analogous to those found in oceanic jets, facilitating transport across the barriers without destroying them completely. We discuss how shearless tori may generically arise from tertiary instabilities or other types of discrete eigenmodes, suggesting their potential relevance to broader classes of turbulent fluctuations.

fusion plasma↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management facility (EMF) stack monitor location was qualified using the LV-S1 scale model stack as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale models and its sampling locations were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the EMF stack was performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of stack flow rates for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on the LV-S1 scale model test DV values, the corresponding stack flow rates for the EMF stack are as listed in Table S1. Table S1. Effluent Management Facility Stack Qualified Flow Range. Stack Parameter EM-1 Minimum Qualified Stack Flow (scfm) 781 Maximum Qualified Stack Flow (scfm) 53,432 The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were less than 5°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, which were all within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes each combination of ACV fan with the DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental methods to test photoionized plasma models in emission

The expanding foil photoionized plasma platform was developed on the Z-machine at Sandia National Laboratories to produce terrestrial photoionized plasmas at some of the same conditions as those observed in astrophysical black hole accretion disks. The specific scientific goals of the platform are motivated by long-standing astrophysical puzzles related to accreting black hole systems. Ultimately, the experimental goal is to inform the supersolar Fe abundance problem by testing photoionized plasma models in emission with at-parameter laboratory data. High quality high resolution emission data with absolute intensity calibration from a laboratory photoionized plasma have never been collected prior to the experiments described here, providing broader motivation. A robust test of the model predictions requires the successful production of a laboratory photoionized plasma along with measurements of the supporting model inputs including the radiation drive spectrum used to create the photoionized plasma, the electron density, and the temperature. The measured absolute spectral radiance in emission collected from the independently diagnosed plasma can be compared against model calculations performed using the measured inputs. In this paper, we focus on the experimental platform and the model inputs, specifically detailing the methodology used to measure the plasma conditions. The moderate electron temperature of ∼41 eV ± 15 eV and electron density of ∼1e19 ± 1.6e18 e−/cm3 and the ∼3e12 W/cm2 x-ray irradiance at the sample confirm that photoionization dominates the plasma ionization and spectra.

Cho, P. B. (ORCID:0000000291632905)↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management Facility (EMF) stack monitor location was qualified using a combination of scale model stacks to mitigate the risk of identifying that the sampling location does not meet the qualification criteria on the full-scale stack. The LV-S1 scale model stack was used as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling locations were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. The LV-S1, LB-S1, and LV-S2 scale model stack tests have met the criteria of the ANSI/HPS N13.1-1999 standard to demonstrate the stack sampling locations are well mixed. Verification tests of the EMF stack were performed at normal operating conditions. The minimum 1/6 DV value and the maximum 6 DV value from the scale model testing determine the range of stack flow rates for which the full-scale stack may be operated while remaining in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rate along with the average and maximum qualified stack flow rate based on the LV-S1 scale model DV values. The operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were <5°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, all of which were within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all planned fan operating configurations. This includes each combination of ACV fans with DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MODELING A SPENT NUCLEAR FUEL CASK SEISMIC TEST

The US Department of Energy Spent Fuel and Waste Science and Technology (SFWST) program is planning to conduct a series of full-scale shake table tests to simulate hypothetical earthquake conditions and record the response of surrogate spent nuclear fuel (SNF) assemblies in a canister dry storage system mockup. The shake table motions will represent a range of hypothetical earthquake conditions at hypothetical locations in the continental US to generally define the range of mechanical loads that SNF can be expected to experience during extended dry storage periods. The earthquake conditions will represent seismic hazards in the 2,000-to-20,000-year return period range. The test will use instrumented pressurized water reactor fuel assemblies with surrogate mass inside the fuel rods instead of radioactive fuel pellets. Dummy assemblies with similar mass and dimensions to actual fuel assemblies will occupy the rest of the fuel assembly locations in a SNF canister that holds 32 fuel assemblies. The canister will be located inside a mockup vertical concrete cask. Instrumentation will record the motion of the major components of the complex dynamic system, and strain gauges will be used to record the cladding strain at select locations. Preparations for the test require modeling predictions to identify the range of response of the system and to help select specific earthquake cases to be simulated on the shake table from a large set of potential cases. This paper describes the pretest nonlinear finite element modeling efforts that have been completed to date, including cask system level modeling and fuel assembly modeling in LS-DYNA. The cask system level models are critical for anticipating sliding or tipping of an unanchored cask during the test. The fuel assembly model is needed to estimate the range of cladding strain response and fuel assembly structural response to be expected during the test and cladding strain measurements will be key metrics for model validation and the development of modeling best practices after the test is concluded.

Klymyshyn, Nicholas A.↗