Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “mirror”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Fabrication and Test of an Optical Magnetic Mirror

Traditional mirrors at optical wavelengths use thin metalized or dielectric layers of uniform thickness to approximate a perfect electric field boundary condition. The electron gas in such a mirror configuration oscillates in response to the incident photons and subsequently re-emits fields where the propagation and electric field vectors have been inverted and the phase of the incident magnetic field is preserved. We proposed fabrication of sub-wavelength-scale conductive structures that could be used to interact with light at a nano-scale and enable synthesis of the desired perfect magnetic-field boundary condition. In a magnetic mirror, the interaction of light with the nanowires, dielectric layer and ground plate, inverts the magnetic field vector resulting in a zero degree phase shift upon reflection. Geometries such as split ring resonators and sinusoidal conductive strips were shown to demonstrate magnetic mirror behavior in the microwave and then in the visible. Work to design, fabricate and test a magnetic mirror began in 2007 at the NASA Goddard Space Flight Center (GSFC) under an Internal Research and Development (IRAD) award Our initial nanowire geometry was sinusoidal but orthogonally asymmetric in spatial frequency, which allowed clear indications of its behavior by polarization. We report on the fabrication steps and testing of magnetic mirrors using a phase shifting interferometer and the first far-field imaging of an optical magnetic mirror.

Hagopian, John G.↗

LUVOIR Primary Mirror Segment Alignment Control With Joint Laser Metrology and Segment Edge Sensing

An approach is developed for the alignment and stability maintenance of the LUVOIR segmented primary mirror using a segment state estimation and wavefront control method based on a hybrid segment motion sensing architecture of laser truss metrology and segment edge sensors. Our current computer model was generated for LUVOIR Architecture Option A with a 15-meter aperture, 120segment primary mirror. The methodology and simulation results will be presented and analyzed. JPL has a long history of technology development in laser metrology and edge sensors, including work in SIM [7], Keck and TMT [8], CCAT [3] and LUVOIR [1]. We will discuss our current efforts of LUVOIR laser metrology and edge-sensor models development, showing sensitivities of sensor measurements to various mirror eigenmodes, removing global modes and strengthening weak modes by performing joint (hybrid) laser-metrology and edge sensing. We will define and derive an important performance metric called wavefront error multiplier (WEM), and show that WEM provides a simple link between sensor errors and the closed-loop (controlled) system wavefront error. We will show WEM values for several hybrid sensor configuration options studied. We will discuss an algorithm for mirror shape control and maintenance through segment state and wavefront estimations using joint edge-metrology sensing. We will compare simulated performance of mirror state estimation, wavefront estimation and wavefront control based on joint edge-metrology sensing among several sensor configurations, and show the impact of sensor error distributions on the segmented mirror alignment performance. Mirror shape control performance will be also be evaluated in terms of imaging contrast between inner working angles (IWA) and outer working angles (OWA) of a LUVOIR coronagraph. The research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration. LUVOIR is a mission concept under study for the next astronomy Decadal Survey—the information presented in this paper is pre-decisional and is provided for planning and discussion purposes only.

Shelton, Chris↗

Stitching interferometry for synchrotron mirror metrology at National Synchrotron Light Source II (NSLS-II)

With the fast development of diffraction-limited storage rings and free electron lasers, the requirement for ultimate quality X-ray mirror is getting higher and the mirror surface needs to approach the sub-nm root mean square height specifications. Here, these ultimate specifications challenge the X-ray mirror metrology community. In this work, we present our developed dedicated stitching metrology platform for X-ray mirror metrology. Various stitching methods with different stitching parameters are investigated in our stitching interferometric system. Some experimental results are given to demonstrate its validity and performance. According to the measurement results, the repeatability of measuring a flat mirror in the software stitching mode is at 0.1 nm RMS level. In relative angle determinable stitching mode when measuring a curved mirror with its radius of curvature varying from 50 m to 175 m, the repeatability is around 1 nm RMS.

42 ENGINEERING↗

Optimal deformation procedure for hybrid adaptive x-ray mirror based on mechanical and piezo-driven bending system

Here, a hybrid deformable x-ray mirror consisting of a mechanical bender and a bimorph deformable mirror has been developed to realize adaptive optical systems, such as zoom condenser optics, for synchrotron-radiation-based x-ray microscopy. In the developed system, both bending mechanisms comprehensively contribute to the formation of the target mirror shape and can narrow the role of piezoelectric actuators, thereby enabling a more stable operation. In this study, the behavior of the bimorph mirror under the clamped condition was investigated, and the sharing of the deformation amount for each bending mechanism was optimized to minimize the amplitude of the voltage distribution of the bimorph mirror.

47 OTHER INSTRUMENTATION↗

Optimized manufacturing process for multilayer two-dimensional focusing mirrors in laboratory X-ray applications

Recent advances in laboratory X-ray applications require high-performance optical components that achieve exceptional imaging resolution and beam uniformity within compact experimental setups. Montel mirrors have become a preferred solution due to their unique dual-reflection focusing mechanism and a space-efficient design. Here, in this study, we present an effective manufacturing process for producing Montel mirrors tailored to focus laboratory X-ray beams. The mirrors were fabricated from single-crystal silicon substrates, chosen for their high mechanical stability and compatibility with precision polishing techniques. Our approach begins with the integration of a deterministic chemo-mechanical polishing (CMP)-based pre-shaping step followed by ion beam figuring (IBF), significantly improving manufacturing efficiency. Subsequently, our custom-developed advanced metrology and IBF techniques were employed for fabricating an off-axis, elliptical cylinder Montel mirror system with a 6-mrad total slope, with stringent optical specifications. While post-IBF processes, including multilayer coating, dicing, and gluing, introduced minor surface errors, yet their impact on performance remained negligible. The Montel mirrors manufactured with the optimized process exhibited significantly improved beam uniformity and a reduced focal spot size. These findings validate our approach as a viable solution for high-precision Montel mirror fabrication and facilitate further advancements in laboratory X-ray applications.

36 MATERIALS SCIENCE↗

A renewable double plasma mirror for Petawatt-class lasers

Exceptional pulse contrast can be critical for ultraintense laser experiments, particularly when using solid density targets, and their use is becoming widespread. However, current plasma mirror technology is becoming inadequate for the new generation of high repetition rate, high power lasers now available. We describe a novel double plasma mirror configuration based on renewable, free standing, ultrathin liquid crystal films tested at the BELLA Petawatt Laser Center. Although operating at a repetition rate of several shots per minute, this system can be scaled to a high repetition rate exceeding 1 Hz and represents an important step towards enabling sustained, continuous operation of plasma mirrors. We demonstrate an improvement of two to three orders of magnitude in contrast and a total throughput of 80%. We present the first measurements of a beam reflected from a single or double plasma mirror system using a wavefront sensor, showing a well preserved wavefront and spatial mode. Finally, we introduce a model that predicts the total throughput through this double plasma mirror. This is the first model that accurately predicts the peak reflectivity of a plasma mirror when given the laser temporal profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feasibility study of high-resolution coherent diffraction microscopy using synchrotron x rays focused by Kirkpatrick-Baez mirrors

High-flux coherent x rays are necessary for the improvement of the spatial resolution in coherent x-ray diffraction microscopy (CXDM). In this study, high-resolution CXDM using Kirkpatrick-Baez (KB) mirrors is proposed, and the mirrors are designed for experiments of the transmission scheme at SPring-8. Both the photon density and spatial coherence of synchrotron x rays focused by the KB mirrors are investigated by wave optical simulation. The KB mirrors can produce nearly diffraction-limited two-dimensional focusing x rays of approx1 mum in size at 8 keV. When the sample size is less than approx1 mum, the sample can be illuminated with full coherent x rays by adjusting the cross-slit size set between the source and the mirrors. From the estimated photon density at the sample position, the feasibility of CXDM with a sub-1-nm spatial resolution is suggested. The present ultraprecise figuring process enables us to fabricate mirrors for carrying out high-resolution CXDM experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-layer mirrors for advanced research light sources

X-ray mirrors are needed for beam guidance, beam alignment and monochromatisation at third-generation synchrotron light sources (PETRA III) and forthcoming Free-Electron Lasers (LCLS, European XFEL). Amorphous carbon coatings are currently used as total reflection mirrors at FLASH to guide the photon beam to the various beamlines. These coatings were prepared by means of magnetron sputtering. The new GKSS sputtering facility for the deposition of single and multilayer mirrors with a length of up to 1500 mm and a width of up to 120 mm is in operation. In this contribution we present the results of this new deposition system. A major advantage is that it is now possible to prepare one, two or more mirrors with similar properties over the whole deposition length. The mirror properties were investigated by means of X-ray reflectometry and interference microscopy. The performance of the mirrors is analyzed, considering X-ray reflectivity, film thickness and surface roughness. The uniformity of these properties over the whole deposition length of 1500 mm is demonstrated. The results obtained will be discussed and compared with former results.

43 PARTICLE ACCELERATORS↗

First principle analyses of direct bandgap solar cells with absorbing substrates versus mirrors

Direct bandgap InP, GaAs, CdTe, and Ga{sub 0.5}In{sub 0.5}P solar cells containing backside mirrors as well as parasitically absorbing substrates are analyzed for their limiting open circuit voltage and power conversion efficiency with comparison to record solar cells. From the principle of detailed balance, it is shown quantitatively that mirror solar cells have greater voltage and power conversion efficiency than their substrate counterparts. Next, the radiative recombination coefficient and maximum radiative lifetime of GaAs mirror and substrate solar cells are calculated and compared to the nonradiative Auger and Shockley-Read-Hall (SRH) lifetimes. Mirror solar cells have greater radiative lifetime than their substrate variants. Auger lifetime exceeds radiative lifetime for both substrate and mirror cells while SRH lifetime may be less or greater than radiative lifetime depending on trap concentration and capture cross section. Finally, the change in free energy of the photogenerated carriers is analyzed in a comparison between InP, GaAs, CdTe, and Ga{sub 0.5}In{sub 0.5}P mirror and substrate solar cells in order to characterize the relationship between solar photon quality and free energy management in solar cells with differing bandgaps. Wider bandgap visible threshold Ga{sub 0.5}In{sub 0.5}P solar cells make better use of the available change in free energy of the photogenerated charge carriers, even when normalized to the bandgap energy, than narrower bandgap near-IR threshold InP, GaAs, and CdTe solar cells.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray microfocusing with off-axis ellipsoidal mirror

High-precision ellipsoidal mirrors for two-dimensionally focusing X-rays to nanometer sizes have not been realized because of technical problems in their fabrication processes. The objective of the present study is to develop fabrication techniques for ellipsoidal focusing mirrors in the hard-X-ray region. We design an off-axis ellipsoidal mirror for use under total reflection conditions up to the X-ray energy of 8 keV. We fabricate an ellipsoidal mirror with a surface roughness of 0.3 nm RMS (root-mean-square) and a surface figure error height of 3.0 nm RMS by utilizing a surface profiler and surface finishing method developed by us. The focusing properties of the mirror are evaluated at the BL29XUL beamline in SPring-8. A focusing beam size of 270 nm × 360 nm FWHM (full width at half maximum) at an X-ray energy of 7 keV is observed with the use of the knife-edge scanning method. We expect to apply the developed fabrication techniques to construct ellipsoidal nanofocusing mirrors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of reflection spectra of soft X-ray multilayer mirrors using a broadband laser-plasma radiation source

The reflection spectra of several concave (spherical and parabolic) periodic Mo/Si, Mg/Si, and Al/Zr multilayer mirrors intended for cosmic experiments were studied with the help of a laser-plasma soft X-ray radiation source. An investigation was made of the reflection spectra of a laboratory aperiodic Mo/Si multilayer mirror optimised for maximum uniform reflectivity in the 125-250-A range. 'Satellites' were observed in the neighbourhood of the principal peak in the spectrum of the periodic 132-A multilayer mirror. High-intensity second-order interference reflection peaks at wavelengths of about 160 A were experimentally revealed in the reflection spectra of the periodic Mo/Si 304-A mirrors. By contrast, the second-order reflection peak is substantially depressed in the spectra of the narrow-band mirrors based on the Mg/Si multilayer structure. The experimental data are compared with theoretical calculations. Manifestations of the NEXAFS structure of the L{sub 2,3} absorption edges of Al and Al{sub 2}O{sub 3} were observed in the spectra recorded. (resonators and mirrors)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

QED with a spherical mirror

We investigate the quantum electrodynamic (QED) properties of an atomic electron close to the focus of a spherical mirror. We first show that the spontaneous emission and excited-state level shift of the atom can be fully suppressed with mirror-atom distances of many wavelengths. A three-dimensional theory predicts that the spectral density of vacuum fluctuations can indeed vanish within a volume {lambda}{sup 3} around the atom, with the use of a far-distant mirror covering only half of the atomic emission solid angle. The modification of these QED atomic properties is also computed as a function of the mirror size, and large effects are found for only moderate numerical apertures. We also evaluate the long-distance ground-state energy shift (Casimir-Polder shift) and find that it scales as ({lambda}/R){sup 2} at the focus of a hemispherical mirror of radius R, as opposed to the well-known ({lambda}/R){sup 4} scaling law for an atom at a distance R from an infinite plane mirror. Our results are relevant for investigations of QED effects as well as free-space coupling to single atoms using high-numerical-aperture lenses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Material Assessment for ITER's Collective Thomson Scattering first mirror

The International Thermonuclear Energy Reactor (ITER) Collective Thomson Scattering (CTS) system is a diagnostic instrument that measures plasma density and velocity through Thomson scattering of microwave radiation. Some of the key components of the CTS are quasi-optical mirrors that are used to produce astigmatic beam patterns, which have impact on the strength and spatial resolution of the diagnostic signal. The mirrors are exposed to neutron radiation, which may alter the quality of the signal received. In this work, three different materials (molybdenum (Mo), stainless steel 316 (SS-316) and tungsten (W)) are considered for the first mirror of the CTS. The objective is to access which of the material studied are best suited for this mirror, considering different neutron radiation loads simulated scenarios defined by ITER, based on the resultant stresses and temperature distributions. For it, the neutron irradiation, and subsequent heat-load on the mirrors are simulated using the Monte Carlo N-Particle (MCNP) code. Based on the MCNP heat-load results, transient thermal-structural Finite Element Analysis (FEA) of the mirror over a 400 s discharge, with and without cooling on the rear side, are conducted using in commercial FEA software ANSYS. Results show that of the tested materials Mo and W are the most suitable material for this application. Even though, this study does not yet consider the variation of the material properties with temperature, it presents a quick initial satisfactory assessment that may be considered in subsequent and more complex analysis. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of a 17 cm robust carbon fiber deformable mirror for adaptive optics

Carbon-fiber reinforced polymer (CFRP) composite is an attractive material for fabrication of optics due to its high stiffness-to-weight ratio, robustness, zero coefficient of thermal expansion (CTE), and the ability to replicate multiple optics from the same mandrel. We use 8 and 17 cm prototype CFRP thin-shell deformable mirrors to show that residual CTE variation may be addressed with mounted actuators for a variety of mirror sizes. We present measurements of surface quality at a range of temperatures characteristic of mountaintop observatories. For the 8 cm piece, the figure error of the Al-coated reflective surface under best actuator correction is {approx}43 nm RMS. The 8 cm mirror has a low surface error internal to the outer ring of actuators (17 nm RMS at 20 C and 33 nm RMS at -5 C). Surface roughness is low (< 3 nm P-V) at a variety of temperatures. We present new figure quality measurements of the larger 17 cm mirror, showing that the intra-actuator figure error internal to the outer ring of actuators (38 nm RMS surface with one-third the actuator density of the 8 cm mirror) does not scale sharply with mirror diameter.

79 ASTRONOMY AND ASTROPHYSICS↗

Mirror Technology Roadmap for NASA's Exoplanet Exploration Program

There are several possible approaches to designing exoplanet missions: (1) Coronagraphs (2) Interferometers (3) Starshades Wavefront sensing and control is the central concern, not mirror size (1) Starlight suppression with deformable mirrors (2) Thermal and structural stability (3) Metrology for sensing and control Diffraction-limited optical primary mirrors 4-m or larger are needed to detect Earthlike planets (1) Surface figure similar to HST required (2) Smaller primary mirrors can be used with aggressive coronagraph designs, but the stability tolerances become the driving concern (3) Stability tolerances of coronagraphs are greatly reduced when larger primaries are used in conjunction with 8th-order masks Long term vision for large telescope development includes space-based segmented-mirror telescopes using actively-controlled glass segments or silicon carbide hybrid-mirror designs

technology↗

Kinematic Alignment and Bonding of Silicon Mirrors for High-Resolution Astronomical X-Ray Optics

Optics for the next generation's high-resolution, high throughput x-ray telescope requires fabrication of well-formed lightweight mirror segments and their integration at arc-second precision. Recent advances in the fabrication of silicon mirrors developed at NASA/Goddard prompted us to develop a new method of mirror alignment and integration. In this method, stiff silicon mirrors are aligned quasi-kinematically and are bonded in an interlocking fashion to produce a "meta-shell" with large collective area. We address issues of aligning and bonding mirrors with this method and show a recent result of 4 seconds-of-arc for a single pair of mirrors tested at soft x-rays.

X-ray optics↗

Effects of electron temperature anisotropy on proton mirror instability evolution

Proton mirror modes are large amplitude nonpropagating structures frequently observed in the magnetosheath. It has been suggested that electron temperature anisotropy can enhance the proton mirror instability growth rate while leaving the proton cyclotron instability largely unaffected, therefore causing the proton mirror instability to dominate the proton cyclotron instability in Earth's magnetosheath. In this paper we use particle-in-cell simulations to investigate the electron temperature anisotropy effects on proton mirror instability evolution. Contrary to the hypothesis, electron temperature anisotropy leads to excitement of the electron whistler instability. Finally, our results show that the electron whistler instability grows much faster than the proton mirror instability and quickly consumes the electron-free energy so that there is no electron temperature anisotropy left to significantly impact the evolution of the proton mirror instability.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prospects for a high-field, compact break-even axisymmetric mirror (BEAM) and applications

This paper explores the feasibility of a break-even-class mirror referred to as BEAM (break-even axisymmetric mirror): a neutral-beam-heated simple mirror capable of thermonuclear-grade parameters and $Q\sim 1$ conditions. Compared with earlier mirror experiments in the 1980s, BEAM would have: higher-energy neutral beams, a larger and denser plasma at higher magnetic field, both an edge and a core and capabilities to address both magnetohydrodynamic and kinetic stability of the simple mirror in higher-temperature plasmas. Axisymmetry and high-field magnets make this possible at a modest scale enabling a short development time and lower capital cost. Such a $Q\sim 1$ configuration will be useful as a fusion technology development platform, in which tritium handling, materials and blankets can be tested in a real fusion environment, and as a base for development of higher- $Q$ mirrors.

Physics↗