Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “micro”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A new flow pattern map for flow boiling of R410A in horizontal micro-fin tubes considering the effect of the helix angle

This paper presents an improved flow pattern map for flow boiling in horizontal micro-fin tubes considering the effect of helix angle. The proposed map is modified from the one developed for horizontal smooth tubes by Wojtan et al. (2005) and takes the early transition to annular flow due to micro-fin geometry into account. Visualization of R410A flow boiling is carried out through the transparent smooth and micro-fin tubes with 0°, 10° and 18° helix angle and plotted on the proposed map for comparison. The result shows that the flow pattern map for micro-fin tube with 0° helix angle is generally similar to that for the smooth tube. For the tube with 10° and 18° helix angle, the annular flow occurs at lower vapor quality and lower mass flux. The proposed map shows good agreements when compared with the visualization and reflects the downward shift (to lower mass flux and vapor quality conditions) of the SW-WA transition with the increase of the helix angle. In order to further validate the proposed model, the flow pattern transitions calculated from the equations are also compared with the experimental data of the micro-fin tube in literature. The results show that the modified map increase the prediction accuracy of the flow patterns in the micro-fin tube.

42 ENGINEERING↗

Macro- and micro-compression testing of shales

Here, macro- and micro-geomechanical properties of shales were investigated at millimeter- and micrometer-scale using an example of the Woodford Shale. Geomechanical properties, such as uniaxial (unconfined) compressive strength and Young's modulus, were quantified at the millimeter-scale and compared with results from micro-compression testing experiments of FIB-SEM-nanofabricated micro-pillars. Size-scale and compositional/structural heterogeneity effect on elasto-plastic deformation and failure behavior of shales were investigated. Also, relationship between elemental/mineral composition and unconfined compressive strength and Young's modulus, at a micrometer-scale, was discussed. It was shown that geomechanical properties of shales are scale-dependent and are strongly affected by compositional/structural anisotropy. In particular, micro-compression testing experiments showed non-uniformly distributed compressive strength and Young's modulus within the investigated Woodford Shale rock samples. It was demonstrated, that geomechanical properties of shales, investigated at the micrometer-scale, tend to be affected by different minerals and/or pores, while the same properties, investigated at the millimeter-scale, are governed by different micro-facies (and/or micro-fractures) present within the rock. This shows that geomechanical properties of shales can be dramatically different depending on the scale of investigation and compositional/structural heterogeneity of these rocks, and therefore are not easily transferable across the scales.

58 GEOSCIENCES↗

Sulphur variations in annually layered stalagmites using benchtop micro-XRF

Variation of sulphur in annually laminated stalagmites can be used to infer the impact of past volcanic activities, anthropogenic pollution, and climate change due to increased bushfire activity. The synchrotron radiation micro-X-Ray fluorescence (SR-XRF) microprobe is a powerful tool to analyse and image sulphur recorded in stalagmites with micrometre resolution. However, access to SR-XRF beamlines can be limited, so researchers must select the most promising stalagmites for imaging. Benchtop micro-XRF is an effective tool for trace elemental analysis of speleothem samples and is a candidate for routine laboratory measurement of sulphur along stalagmite laminae and screening for SR-XRF. Here, this study describes a protocol using matrix-matched standards to measure annual variations of sulphur at trace to percent level along the laminae of two Western Australian stalagmites, one of which already having been analysed using SR-XRF. Parameters that affected quantitation include X-ray tube voltage and current, spot size of the X-ray beam and stalagmite surface roughness and porosity. The use of a 20 μm X-ray spot size provides sub-annual spatial resolution that can be completed in an overnight scan. The features in a 1000 point micro-XRF analysis of sulphur along a 20 mm transect show good consistency with SR-XRF microprobe data. Micro-XRF mapping was also performed to produce chemical images on the stalagmite and compared with Raman and X-ray diffraction (XRD) to confirm that the stalagmite is exclusively calcite, with no aragonite, and that the source of sulphur in the samples was gypsum and anhydrite. Regions of very high sulphur in the micro-XRF maps were found to be artefacts due to diffraction of the incident beam but these could be efficiently removed by using a multiple point statistics approach to produce a clean image suitable for analysis of the laminae. This work shows the potential of micro-XRF for routine analysis of sulphur in stalagmites, and to streamline sample characterisation before SR-XRF imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automatic Detection and Evaluation of Solar Cell Micro-Cracks in Electroluminescence Images Using Matched Filters

A method for detecting micro-cracks in solar cells using two dimensional matched filters was developed, derived from the electroluminescence intensity profile of typical micro-cracks. We describe the image processing steps to obtain a binary map with the location of the micro-cracks. Finally, we show how to automatically estimate the total length of each micro-crack from these maps, and propose a method to identify severe types of micro-cracks, such as parallel, dendritic, and cracks with multiple orientations. With an optimized threshold parameter, the technique detects over 90 % of cracks larger than 3 cm in length. The method shows great potential for quantifying micro-crack damage after manufacturing or module transportation for the determination of a module quality criterion for cell cracking in photovoltaic modules.

14 SOLAR ENERGY↗

Low Cost Micro-Spectrometer for Resource Mapping on Mars

Scientific measurements within craters and along steep embankments on Mars pose extreme challenges since astronauts and rovers cannot access them. However, these areas offer the potential for thegreatest scientific return. NASA Langley Research Center (LaRC) has invented a deployable wireless micro-spectrometer [1-13] capable of accessing thosechallenging areas and, using telemetry, send measurements to a receiver safely outside those extreme environments. A prototype of the micro-spectrometer concept was fabricated and successfullytested for measurement of dopamine as a neural probe [14]. The bullet-sized micro-spectrometer concept can be designed for deployment by an astronaut, a rover, an aerial drone, or a lander, and the measurements broadcasted back to a receiver [13,15,16]. This device can also be installed on rovertires, under the astronaut’s boots, or a cane stick. The bullet-like consumable micro-spectrometer can penetrate soil to spectrally identify the components ofthe soil, such as water or minerals. The signals of the soil assay data are transmitted to a mother station through a telemetry system. The LaRC developed micro-spectrometer bullet consists of micro-spectrometer optics with an all imbedded burst-mode LED UV light source, a super-capacitor with control electronics, and telemetry electronics. Prototypes have been fabricated to demonstrate spectral assay of soil components. Further maturation of this technology would be necessary for demonstration on Mars. Future work includes a potential R&D program that includes other NASA Centers and industry partners interested in developing a business case that requires knowledge of the locations of extraterrestrial ice, for instance.

micro-spectrometer, mineral assay, resource mappin↗

Quantitative Analysis of Micro-structural Changes in a Bituminous Coal After Exposure to Supercritical CO{sub 2} and Water

High-volatile bituminous coal samples were reacted in deionized water with supercritical CO{sub 2} (ScCO{sub 2}–water) under simulated in situ pressure and temperature conditions (8 MPa and 40 °C) in unconfined stress state for 14 days, in order to characterize potential CO{sub 2}–water–coal reactions. Micro-structural changes were identified pre- and post-experiment using X-ray powder diffraction (XRD) analysis for powdered coal (mineralogical changes), optical microscopy and scanning electron microscopy (SEM) for polished thin sections (surface feature changes) and micro-CT scanning for a small core (porosity and permeability changes). XRD analysis revealed that carbonic acid leaches out mineral matters in coal, including carbonates (calcite) and silicate minerals (albite, illite and kaolinite). Optical microscopy, SEM and CT images confirmed that the interaction of coal with ScCO{sub 2}–water causes an abundance of micro-cracks to open or propagate in unconfined coal samples. Most micro-cracks preferably propagated along maceral–mineral and maceral–maceral interfaces, which demonstrates that the micro-cracking was caused by differential swelling of different coal lithotypes. Wormhole formation was observed in coal caused by mineral dissolution and hydrocarbon mobilization, which significantly increases coal porosity compared with swelling-induced cracking. 3-D pore network models extracted from CT images show that ScCO{sub 2}–water treatment enlarges the pore and throat size, increases the numbers of pores and throats and improves pore network connectivity. Overall, CO{sub 2}–water–coal interactions under unconfined conditions enhance coal porosity, connectivity and permeability, which can be attributed to the combined effect of micro-cracking, mineral dissolution and hydrocarbon mobilization.

58 GEOSCIENCES↗

Quantitative microstructural investigation of 3D-printed and cast cement pastes using micro-computed tomography and image analysis

Highlights: • Processing alters the microstructure in 3D-printed lamellar cubic element. • A unique patterned and connected pore microstructure network exists. • Micro-channels are connected through micro-pores present at interfaces regions. • Three distinct pore volume domains exists in hardened microstructure. • Volume and frequency of pore, hydrated, and unhydrated clusters are dissimilar. Microstructural phases and mechanical properties of lamellar 3D-printed and cast hardened cement paste (hcp) elements were investigated using a lab-based X-ray microscope at two levels of magnification (0.4× and 4×). K-means clustering was used for quantitative image analysis. The entire volume of intact 3-days-old 3D-printed and cast hcp elements was characterized at 0.4× magnification. Three microstructural features (macro-pores, micro-channels, and interfacial micro-pores) were found to reside in three distinct pore size domains. The largest pores of the 3D-printed element were larger than the largest pores of the reference cast hcp element. Moreover, the smallest pore sizes of the 3D-printed element were found to be smaller than those present in the cast counterparts. Micro-channels were found to be connected to one another through the micro-pores present at interfacial regions, indicating the presence of a uniquely patterned and interconnected pore network. The role of locally weak and porous interfaces on mechanical response and fracture properties is discussed.

36 MATERIALS SCIENCE↗

Adaptive simulations enable computational design of electron beam processing of nanomaterials with supersonic micro-jet precursor

Focused Electron Beam Induced Processing (FEBIP) is a powerful tool for the “direct-write” of nanomaterials with the possibility of atomistic control on suspended 2D material substrates. FEBIP capabilities have been significantly expanded by using a localized jet-based delivery of precursors, and especially when a thermally energized supersonic micro-jet enhances the delivery of mass flux along with controlling the far-from-equilibrium thermodynamic state of adsorbed adatoms. The possibilities of growing nanomaterials with “dialed-in” composition with ultra-high growth rates and aspect ratios up to 100:1 have been demonstrated using the supersonic micro-jet-FEBIP. Bringing this scientific discovery to the level of maturity required for practical applications in additive nanomanufacturing requires simulation tools that are capable of capturing the complex flow physics of micro-jet-substrate interactions that bridge a wide range of flow regimes from the high-density gas micro-jet expanding into the vacuum environment of FEBIP. To address this significant computational challenge, a new approach has been developed and described in this work for a multiscale adaptive DSMC (Direct Simulation Monte Carlo) algorithm to predict the micro-jet gas dynamics in an FEBIP environment, spanning the full range of flow regimes from low Knudsen (Kn) number O(0.01) continuum flow to high Kn of O(10) for the molecular flow within a unified computational framework. Here, the fundamental principles of the adaptive DSMC algorithm are described, its viability as a DSMC technique is demonstrated, and computational improvements for the benchmark cases are discussed in the context of advancing 3D nanofabrication with FEBIP. Ultimately, combining the first principle simulations via adaptive DSMC with the complementary experimental data will enable the creation of the powerful CAD tools for in silico design and optimal operation of micro-jet-FEBIP.

36 MATERIALS SCIENCE↗

The effect of spatial micro-CT image resolution and surface complexity on the morphological 3D analysis of open porous structures

In material science microfocus X-ray computed tomography (micro-CT) is one of the most popular non-destructive techniques to visualise and quantify the internal structure of materials in 3D. Despite constant system improvements, state-of-the-art micro-CT images can still hold several artefacts typical for X-ray CT imaging that hinder further image-based processing, structural and quantitative analysis. For example spatial resolution is crucial for an appropriate characterisation as the voxel size essentially influences the partial volume effect. However, defining the adequate image resolution is not a trivial aspect and understanding the correlation between scan parameters like voxel size and the structural properties is crucial for comprehensive material characterisation using micro-CT. Therefore, the objective of this study was to evaluate the influence of the spatial image resolution on the micro-CT based morphological analysis of three-dimensional (3D) open porous structures with a high surface complexity. In particular the correlation between the local surface properties and the accuracy of the micro-CT-based macro-morphology of 3D open porous Ti6Al4V structures produced by selective laser melting (SLM) was targeted and revealed for rough surfaces a strong dependence of the resulting structure characteristics on the scan resolution. Reducing the surface complexity by chemical etching decreased the sensitivity of the overall morphological analysis to the spatial image resolution and increased the detection limit. This study showed that scan settings and image processing parameters need to be customized to the material properties, morphological parameters under investigation and the desired final characteristics (in relation to the intended functional use). Customization of the scan resolution can increase the reliability of the micro-CT based analysis and at the same time reduce its operating costs. - Highlights: • We examine influence of the image resolution on μCT-based morphological analysis. • Surface properties influence accuracy of μCT-based morphology of porous structures. • Total porosity was the least sensitive to surface complexity and scan voxel size. • The beam thickness analysis was overestimated by the surface roughness. • Voxel size customization can significantly reduce a cost of the μCT-based analysis.

36 MATERIALS SCIENCE↗

Characterization of martensite-austenite constituents and micro-hardness in intercritical reheated and coarse-grained heat affected zones of API X70 HSLA steel

Highlights: • The influence of cold wire addition to the tandem submerged arc welding process on the ICRCGHAZ is investigated. • Comprehensive characterization of the microstructure and micro-hardness in the ICRCGHAZ of a HSLA steel is performed. • A lower fraction of finely distributed M-A formed in the ICRCGHAZ of TSAW + cold wire steel, leading to lower micro-hardness. • The aspect ratio and inter-particle spacing of M-A constituents decreased in the ICRCGHAZ through cold wire addition. - Abstract: The thermal cycles that high strength low alloy (HSLA) low carbon steels experience during welding inevitably affect the microstructure and mechanical properties of the weld joints. It is generally agreed that the coarse-grained heat affected zone (CGHAZ) and the intercritical reheated coarse-grained heat affected zone (ICRCGHAZ) in one-pass and multi-pass welding, respectively, have the poorest microstructure and mechanical properties relative to the rest of the steel joint. The martensite-austenite (M-A) constituents formed in the HAZ regions predominantly govern property deterioration in the CGHAZ and the ICRCGHAZ by promoting the initiation and propagation of micro-cracks. However, the characteristics of the M-A constituents, i.e., fraction, size, shape and aspect ratio, are strongly affected by the welding heat input. Accordingly, in this study, the aim was to evaluate the influence of a cold wire addition in conventional tandem submerged arc welding (TSAW + cold-wire) on the microstructure and micro-hardness in the CGHAZ and ICRCGHAZ. Microstructural characterization showed that a lower fraction of finely distributed M-A constituents associated with smaller prior austenite grains (PAGs) formed in the CGHAZ of the steel welded by the TSAW + cold-wire process (CW-OD weld) relative to that welded by the conventional TSAW process (TW-OD weld). Furthermore, the fraction of M-A constituents in the ICRCGHAZ of the CW-OD weld was decreased. A higher fraction of slender shaped M-A constituents in the ICRCGHAZ of the TW-OD weld resulted in an increase in the micro-hardness. The microstructure and micro-hardness changes associated with cold wire addition were attributed to the lower welding heat input and, consequently, the faster cooling rate with a corresponding reduction in the retention time in the austenitic region and ferrite/austenite region in the CGHAZ and ICRCGHAZ regions, respectively.

36 MATERIALS SCIENCE↗

Determination of Specific Forces and Tool Deflections in Micro-milling of Ti-6Al-4V alloy using Finite Element Simulations and Analysis

Titanium alloys offer superb properties in strength, corrosion resistance and biocompatibility and are commonly utilized in medical devices and implants. Micro-end milling process is a direct and rapid fabrication method for manufacturing medical devices and implants in titanium alloys. Process performance and quality depend upon an understanding of the relationship between cutting parameters and forces and resultant tool deflections to avoid tool breakage. For this purpose, FE simulations of chip formation during micro-end milling of Ti-6Al-4V alloy with an ultra-fine grain solid carbide two-flute micro-end mill are investigated using DEFORM software.At first, specific forces in tangential and radial directions of cutting during micro-end milling for varying feed advance and rotational speeds have been determined using designed FE simulations for chip formation process. Later, these forces are applied to the micro-end mill geometry along the axial depth of cut in 3D analysis of ABAQUS. Consequently, 3D distributions for tool deflections and von Misses stress are determined. These analyses will yield in establishing integrated multi-physics process models for high performance micro-end milling and a leap-forward to process improvements.

36 MATERIALS SCIENCE↗

Micro Electro Discharge Machining of Electrically Nonconductive Ceramics

EDM is a known process for machining of hard and brittle materials. Due to its noncontact and nearly forceless behaviour, it has been introduced into micro manufacturing and through constant development it is now an important means for producing high-precision micro geometries. One restriction of EDM is its limitation to electrically conducting materials.Today many applications, especially in the biomedical field, make use of the benefits of ceramic materials, such as high strength, very low wear and biocompatibility. Common ceramic materials such as Zirconium dioxide are, due to their hardness in the sintered state, difficult to machine with conventional cutting techniques. A demand for the introduction of EDM to these materials could so far not be satisfied because of their nonconductive nature.At the Chemnitz University of Technology and the Fraunhofer IWU, investigations in the applicability of micro-EDM for the machining of nonconductive ceramics are being conducted. Tests are undertaken using micro-EDM drilling with Tungsten carbide tool electrodes and ZrO{sub 2} ceramic workpieces. A starting layer, in literature often referred to as 'assisting electrode' is used to set up a closed electric circuit to start the EDM process. Combining carbon hydride based dielectric and a specially designed low-frequency vibration setup to excite the workpiece, the process environment can be held within parameters to allow for a constant EDM process even after the starting layer is machined. In the experiments a cylindrical 120 {mu}m diameter Tungsten carbide tool electrode and Y{sub 2}O{sub 3}- and MgO- stabilized ZrO{sub 2} worpieces are used. The current and voltage signals of the discharges within the different stages of the process (machining of the starting layer, machining of the base material, transition stage) are recorded and their characteristics compared to discharges in metallic material. Additionally, the electrode feed is monitored. The influences of the process parameters are analysed with regard to the discharge type, electrode wear and process speed.Using the found parameters, micro geometries can be successfully machined into nonconductive Y{sub 2}O{sub 3}- and MgO- stabilized ZrO{sub 2} ceramic by means of micro-EDM.

36 MATERIALS SCIENCE↗

Study of micro-pinches in wire-array Z pinches

Bright and hot areas with a high plasma density and temperature are observed in all kinds of Z pinches. We studied bright radiating spots produced by micro-pinches in cylindrical and planar wire-arrays at the 1 MA Zebra pulsed power generator using an x-ray streak camera synchronized with laser diagnostics, x-ray time-gated pinhole camera, and spectroscopy. Hot spots with extremely dense and relatively hot plasma arise during the collapse of the micro-pinches. These hot spots radiate a continuum spectrum with energy >2.5 keV. Typical micro-pinches in Al wire arrays generate x-ray bursts with durations of 0.4–1 ns in the soft x-ray range and 0.1–0.4 ns in the keV range. UV two-frame shadowgraphy shows spatial correlation of hot spots with the collapse and explosion of micro-pinches. Micro-pinches typically occur at the necks of the Z pinch, but can demonstrate a variety of parameters and different dynamics. An analysis of x-ray streak images shows that micro-pinches can generate >20% of the x-ray energy in some types of wire-array Z pinches.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Feasibility of cooling positrons via conduction in conductive micro-tubes

A first order perturbation with respect to velocity has been employed to find the frictional damping force imposed on a single moving charge inside a conductive cylindrical micro-tube. The tensorial relationship between the force and velocity is derived and numerically estimated. Our results asymptotically match that of a flat geometry presented in the literature. Using the single particle analysis the cooling is formulated for an arbitrary density ensemble. It is shown that no further cooling via conduction occurs in the well-established non-neutral plasma equilibrium state. Also, the cooling rate for a weakly interacting ensemble is estimated. It is shown micro-tubes can be employed to cool down low density positron ensembles and/or to improve the beam emittance. A pack of tens of thousands of individual micro-tubes, each cooling only tens of positrons, is capable of cooling hundreds of thousands of particles in each cooling cycle. For example, with tens of particles per micro-tube in a 5 cm long micro-tube stack with the resistivity of 0.46 Ωm and the tubes of radius 50 μm, hundreds of thousands of positrons can be cooled down with a time constant of 103 μs in longitudinal and 7 μs in perpendicular direction. However, it must be noted that the cooling does not guarantee long term storage of particles in micro-tubes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optomechanical interaction in fibre lasers with micro-optomechanical resonance structures

We report the results of studies of fibre lasers with passive modulators based on light-excited micro-optomechanical resonance structures (micro-oscillators). It is shown that in fibre lasers based on active fibres doped with rare-earth elements (Er, Er/Yb, Yb, Nd), the optomechanical interaction of laser radiation with micro-oscillators of various types (fibre-optic, microvolume) leads to self-oscillations of the characteristics of laser radiation at frequencies of relaxation oscillations and intermode beats synchronised with the frequencies of elastic eigenoscillations of micro-oscillators. It is found that in an ultra-long erbium – ytterbium fibre laser with a nonlinear mirror based on a microcantilever, laser photothermal excitation of the second mode of elastic transverse oscillations of the microcantilever makes it possible to perform passive mode locking exclusively due to Q-switching of the laser cavity. Pulsed lasing with a controlled repetition rate (∼76 kHz), a pulse duration of 2 – 5 μs and an output energy of 0.1 μJ per pulse is implemented. Based on a simplified physical model of the indicated fibre lasers with micro-oscillators, we have developed an approximate mathematical model describing the regimes of passive mode locking of fibre lasers with micro-oscillators that play the role of mirrors with a nonlinear reflection coefficient in the laser cavity. The prospects for the development and application of the considered laser systems are discussed. (control of laser radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interior micro-CT with an offset detector

Purpose: The size of field-of-view (FOV) of a microcomputed tomography (CT) system can be increased by offsetting the detector. The increased FOV is beneficial in many applications. All prior investigations, however, have been focused to the case in which the increased FOV after offset-detector acquisition can cover the transaxial extent of an object fully. Here, the authors studied a new problem where the FOV of a micro-CT system, although increased after offset-detector acquisition, still covers an interior region-of-interest (ROI) within the object. Methods: An interior-ROI-oriented micro-CT scan with an offset detector poses a difficult reconstruction problem, which is caused by both detector offset and projection truncation. Using the projection completion techniques, the authors first extended three previous reconstruction methods from offset-detector micro-CT to offset-detector interior micro-CT. The authors then proposed a novel method which combines two of the extended methods using a frequency split technique. The authors tested the four methods with phantom simulations at 9.4%, 18.8%, 28.2%, and 37.6% detector offset. The authors also applied these methods to physical phantom datasets acquired at the same amounts of detector offset from a customized micro-CT system. Results: When the detector offset was small, all reconstruction methods showed good image quality. At large detector offset, the three extended methods gave either visible shading artifacts or high deviation of pixel value, while the authors’ proposed method demonstrated no visible artifacts and minimal deviation of pixel value in both the numerical simulations and physical experiments. Conclusions: For an interior micro-CT with an offset detector, the three extended reconstruction methods can perform well at a small detector offset but show strong artifacts at a large detector offset. When the detector offset is large, the authors’ proposed reconstruction method can outperform the three extended reconstruction methods by suppressing artifacts and maintaining pixel values.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-H-CAMPUS-TeP2-03: High Sensitivity and High Resolution Fiber Based Micro-Detector for Sub-Millimeter Preclinical Dosimetry

Purpose: Current precision of small animal and cell micro-irradiators has continuously increased during the past years. Currently, preclinical irradiators can deliver sub-millimeter fields with micrometric precision but there are no water equivalent dosimeters to determine small field profiles and dose in the orthovoltage range of energies with micrometric resolution and precision. We have developed a fiber based micro-dosimeter with the resolution and dosimetric accuracy required for radiobiological research. Methods: We constructed two prototypes of micro-dosimeters based on different compositions of fiber scintillators to study the spatial resolution and dosimetric precision of small animal and cell micro-irradiators. The first has green output and the second has blue output. The blue output dosimeter has the highest sensitivity because it matches the spectral sensitivity of silicon photomultipliers. A blue detector with 500um cross section was built and tested respect to a CC01 ion chamber, film, and the 1500um green output detector. Orthovoltage fields from 1×1mm2 to 5×5mm2 were used for detector characteristics comparison. Results: The blue fiber dosimeter shows great agreement with films and matches dose measurements with the gold-standard ion chamber for 5×5mm2 fields. The detector has the appropriate sensitivity to measure fields from 1×1mm2 to larger sizes with a 1% dosimetric accuracy. The spatial resolution is in the sub-millimeter range and the spectral matching with the photomultiplier allows reducing the sensor cross section even further than the presented prototype. These results suggest that scintillating fibers combined with silicon photomultipliers is the appropriate technology to pursue micro-dosimetry for small animals and disperse cell samples. Conclusion: The constructed detectors establish a new landmark for the resolution and sensitivity of fiber based microdetectors. The validation of the detector in our small animal and cell irradiator shows that they are appropriate for preclinical and micro single cell irradiation quality assurance and dosimetry.

60 APPLIED LIFE SCIENCES↗

Research, Development and Demonstration of Micro-CHP System for Residential Applications

ECR International and its joint venture company, Climate Energy, are at the forefront of the effort to deliver residential-scale combined heat and power (Micro-CHP) products to the USA market. Part of this substantial program is focused on the development of a new class of steam expanders that offers the potential for significantly lower costs for small-scale power generation technology. The heart of this technology is the scroll expander, a machine that has revolutionized the HVAC refrigerant compressor industry in the last 15 years. The liquid injected cogeneration (LIC) technology is at the core of the efforts described in this report, and remains an excellent option for low cost Micro-CHP systems. ECR has demonstrated in several prototype appliances that the concept for LIC can be made into a practical product. The continuing challenge is to identify economical scroll machine designs that will meet the performance and endurance requirements needed for a long life appliance application. This report describes the numerous advances made in this endeavor by ECR International. Several important advances are described in this report. Section 4 describes a marketing and economics study that integrates the technical performance of the LIC system with real-world climatic data and economic analysis to assess the practical impact that different factors have on the economic application of Micro-CHP in residential applications. Advances in the development of a working scroll steam expander are discussed in Section 5. A rigorous analytical assessment of the performance of scroll expanders, including the difficult to characterize impact of pocket to pocket flank leakage, is presented in Section 5.1. This is followed with an FEA study of the thermal and pressure induced deflections that would result from the normal operation of an advanced scroll expander. Section 6 describes the different scroll expanders and test fixtures developed during this effort. Another key technical challenge to the development of a long life LIC system is the development of a reliable and efficient steam generator. The steam generator and support equipment development is described in Section 7. Just one year ago, ECR International announced through its joint venture company, Climate Energy, that it was introducing to the USA market a new class of Micro-CHP product using the state-of-the-art Honda MCHP gas fired internal combustion (IC) engine platform. We now have installed Climate Energy Micro-CHP systems in 20 pilot demonstration sites for the 2005/2006 heating season. This breakthrough success with IC engine based systems paves the way for future advanced steam cycle Micro-CHP systems to be introduced.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗