Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “metering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Voltage Calculations in Secondary Distribution Networks via Physics-Inspired Neural Network Using Smart Meter Data

The increasing penetration of distributed energy resources (DERs) leads to voltage issues across distribution networks, necessitating voltage calculations by utilities. Electric model-free voltage calculation offers an enticing solution. However, most researches mainly focus on primary distribution networks ignoring secondary distribution networks and commonly overlook extreme voltage case calculations, which require the model’s extrapolation abilities. Here, in addressing the gaps, this paper presents a customized physics-inspired neural network (PINN) model, the structure of which is inspired by the derived coupled power flow model of primary-secondary distribution networks. To ensure precision and rapid convergence, a crafted training framework for the PINN model is proposed. The PINN’s “structure-mimetic” design enables superior extrapolation for unseen scenarios and enhances physical information awareness. We demonstrate this through two applications: hosting capacity analysis and customer-transformer connectivity. The effectiveness and advantages of the proposed PINN model are validated on two public testing systems and one utility distribution feeder model.

Distribution network↗

Data-Driven Modeling of High-Resolution Residential Load Profiles Using Low-Resolution Smart Meter Measurements

Accurate and high-resolution residential load profiles are essential for power system modeling, demand response planning, and effective grid operation. As the energy sector moves towards a more actively managed distribution system, the ability to understand residential energy consumption at a minute-by-minute scale becomes increasingly critical. High-resolution load profiles provide key insights into demand patterns and user behavior, enabling grid operators to design more effective energy solutions; however, residential load measurements in the field are typically recorded at low resolutions, such as 15-60 minutes, which makes it hard to study the characteristics of different residential customers. This paper addresses these challenges by introducing a data-driven approach to generate realistic, high-resolution residential load profiles based on lowre-solution measurements and weather information. The proposed method retains the key features of the actual residential load measurements while offering appliance-level energy consumption details for each residential building. The results demonstrate the effectiveness of the proposed load profile generator, proving its capability to support utilities in optimizing residential energy management and ensuring a more reliable and resilient grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Static metrology of the meter-scale deformable heliostat

This paper describes a heliostat metrology system which is developed based on deflectometry, utilizing a static perforated panel instead of conventional dynamic monitor displays to provide incident rays. The developed method is named static screen deflectometry (SSD). This robust and scalable method is especially valuable for outdoor tests of large reflectors used in concentrating solar-thermal power (CSP) systems. The developed method has been successfully demonstrated on a 2.4 𝑚 × 3.3 𝑚 float glass deformable reflector bent to focus sunlight at 113 𝑚 distance throughout a day. From images obtained from a camera at 50𝑚 distance, the reflector surface was measured to an accuracy of less than 1 𝑚𝑟𝑎𝑑 rms slope error in the full test scope.

14 SOLAR ENERGY↗

Kinetic and temperature sensitivity properties of soil exoenzymes through the soil profile down to one-meter depth at a temperate coniferous forest (Blodgett, CA)

This dataset contains data on kinetic and temperature sensitivity parameters of the exoenzymes β-glucosidase (BG), leucine/leucyl aminopeptidase (LAP) and acid phosphatase (AP) across a soil profile down to 90 cm depth at Blodgett forest, CA, USA. These data were generated to determine if kinetic and thermal properties of microbial exoenzymes involved in organic matter decomposition varied with soil depth, following variation in soil properties and microbial communities, as part of the study: Alves et al. (2021). Kinetic Properties of Microbial Exoenzymes Vary with Soil Depth but Have Similar Temperature Sensitivities Through the Soil Profile. Frontiers in Microbiology 12:3618. https://doi.org/10.3389/fmicb.2021.735282. This research was performed within the framework of the TES Belowground Biogeochemistry SFA project, in particular association with a long-term field warming experiment of the whole soil profile at Blodgett forest. Samples for this work were collected from locations representative of the field experimental plots. Potential enzyme activity rates were measured using laboratory fluorometric assays with soils collected at 0-10, 10-20, 30-40, 50-60, 60-70 and 80-90 cm deep in biological triplicates (i.e., three soil cores collected at different representative locations). Assays with each soil were conducted over a gradient of eight substrate concentrations per enzyme, and incubated at 4, 10, 16, 25, 35 or 50°C. Enzyme Michaelis-Menten kinetics were modeled over the eight substrate concentrations at each temperature, and the temperature sensitivity of the kinetic parameters was modeled over the six temperatures using linear Arrhenius/Q10 and non-linear Macromolecular Rate Theory (MMRT) models. The dataset includes the fully processed enzyme activity rate data used to model Michaelis-Menten kinetics, calculated kinetic and temperature sensitivity parameters, and basic soil and microbial biomass chemistry for each sample. All data is provided for each individual biological replicate, and kinetic and temperature sensitivity parameters are also provided as means of the biological replicates. The dataset also includes all raw measurement data and code used to parse, combine and perform the analyses described by Alves et al. (2021). For file descriptions, see the file-level metadata files: “enzymes_dataProcessed_flmd.xlsx” (processed data); “enzymes_dataRaw_flmd.xlsx” (compressed raw data and metadata); and “enzymes_code_flmd.xlsx” (compressed code). The experimental design, list of parameters measured, soil and microbial biomass chemistry data, and means of biological replicates for kinetic and temperature sensitivity parameters are also provided as human-readable tables in file “enzymeTraits_design_results_tables.xlsx”.

54 ENVIRONMENTAL SCIENCES↗

Net Metering Expansion on the Winnebago Tribe of Nebraska Reservation (Final Technical Report)

The Winnebago Tribe of Nebraska, through their affiliated economic development entity Ho-Chunk, Inc; their affiliated non-profit Ho-Chunk Community Development Corporation; and an additional project partner Nebraska Renewable Energy Systems conducted a community scale renewable energy project on their reservation in Nebraska. Over the two-year project period, we installed PV Solar systems on ten tribally owned commercial/retail/office facilities, which included both six roof mounted and four pole mount installations. The project was undertaken as a part of the Tribe’s broader initiative to increase renewable energy production on the reservation, reduce the Tribe’s financial obligations for purchasing energy, and lessen our reliance upon outside sources of energy to meet our basic needs. The project enabled us to formalize and strengthen community collaborations and build our capacity to pursue additional renewable energy opportunities that will enhance our energy sovereignty.

14 SOLAR ENERGY↗

Design of Microwave Resonant Cavity Transducer. Development of sensor performance model of microwave cavity flow meter for advanced reactor high temperature fluids

High-temperature fluid reactors, such as molten salt cooled reactors (MSCR) and sodium fast reactors (SFR), are a promising advanced reactor option. Measurement of high-temperature fluid process variables, in particular the flow inside the pressure vessel, is a challenging task because of harsh environment, which includes high radiation, high temperature, and contact with highly corrosive coolant fluid. We are investigating a microwave cavity-based transducer for high-temperature fluid flow sensing. This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. A cavity is characterized by its resonant frequencies. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the flow sensor is evaluated with signal sensitivity using COMSOL computer simulations. A right cylinder geometry stainless steel cavity with dimeter of 0.8in was investigated. We choose membrane thickness of 10mil, so that corrosion anticipated to proceed at the rate of 1mil/year in liquid sodium would affect no more than 10% of the membrane. Using the properties of liquid sodium fluid, and stainless-steel material property values at 500oC, we calculate frequency shift for a range of values of fluid velocity from 0.5m/s to 2m/s. Results of computer simulations indicate measurable sensitivity to flow for this cavity design. Following these simulations, we have developed a preliminary design for fabrication of a transducer operating in microwave K-band for proof-of-principle tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Behind the Meter Solar+Storage: Market data and trends [Slides]

As the distributed solar market evolves toward more dynamic forms of deployment, interest in paired solar-plus-storage applications continues to gain steam, but details on the current state of the market are relatively sparse. To fill that void, Berkeley Lab has released an in-depth analysis of this budding market segment. This report draws on the Lab’s Tracking the Sun dataset to characterize trends in deployment, system sizing and equipment selection, installer-market development, and system pricing. The report also provides indicative analyses of the financial and resilience value that host customers in several key markets presently receive by pairing storage with solar.

14 SOLAR ENERGY↗

Laboratory Wind Turbine Blade Static Testing of the Sandia National Rotor Testbed 13-Meter Wind Turbine Blade

The Sandia National Laboratories (SNL or Sandia) National Rotor Testbed (NRT) blade is a new design for experimental research and development at the Sandia Scaled Wind Farm Technology (SWiFT) facility, located at Texas Tech University’s National Wind Institute Research Center in Lubbock, TX. Four NRT blades were manufactured, with three blades for operation at the SWiFT facility, and one blade intended for structural validation. A series of structural validation tests including property testing, static strength testing, and fatigue testing were performed at the National Renewable Energy Laboratory (NREL). This report documents the static and fatigue load cases applied to the NRT blade.

17 WIND ENERGY↗

First Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the sensor was initially investigated with analytical derivations and with COMSOL RF Module computer simulations of resonant frequency spectral shift due to uniform load. We also investigated the mechanical integrity of the flowmeter’s membrane through analytical modelling and COMSOL Structural Mechanics Module computer simulations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the material’s yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure. Using results from models, we have developed an initial design for a microwave K-band sensor. A cylindrical resonator prototype was fabricated from brass for the initial tests. The external dimensions of the cavity are matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed consisting of a piping Tee with a bulkhead WR-42 microwave waveguide installed in a leak-proof assembly. A microwave waveguide circulator was installed in the setup to suppress the effect of reflections at the cavity entrance by increasing the isolation between the input and the output port. Preliminary spectral characterization of cavity spectral response was performed with a portable PXIe chassis microwave VNA with a custom GUI. Preliminary dry tests of the transducer response were conducted with a set of calibrated weights. Transducer frequency shift was shown to be monotonically increasing with increasing pressure. The next steps will involve investigation of the transducer performance for water flow sensing.

42 ENGINEERING↗

Check the Storage Stack: Comparing Behind-the-Meter Energy Storage State Policy Stacks in the United States

A variety of studies and disparate datasets track state energy storage polices, but these datasets do not cover all BTM-related storage policy. Moreover, these databases do not align these policies with the policy stacking framework. Thus, it is unclear what BTM storage policies are adopted across the country, what should comprise a complete storage policy framework or stack, and how states policies compare against that stack. This report addresses this gap in the literature by developing a state policy stack for BTM battery storage that we compare across all fifty states. This first-of-its-kind BTM storage policy stack includes 11 parent policy categories, and 31 associated policies divided across the market preparation, creation, and expansion policy components.

25 ENERGY STORAGE↗

FTR for: Reducing plug-load electricity footprint of residential buildings through low-cost, non-intrusive sub-metering and personalized feedback technology

The project started in October 2016 and ended in December 2022. The project's principal goals and achievements were: (i) Measure real and reactive electric power consumption in ~400 apartments in multifamily settings of varying size and vintage and publish the data; data was published according to New York State's recommended 15x15 rule continuously from Jan 2019 through December 2022 (10 second time resolution); with the combination of large number of apartments, real and reactive power, as well as high time resolution (10-seconds), the dataset is first of its kind worldwide; because the dataset New York City apartment consumption pre, during, and post pandemic, it further offers unique insights into changes in residential electricity consumption during lockdowns and after modified work from home schedules. (ii) Measure effectiveness of different feedback types to prompt residents to lower their electricity consumption; achieved 11% (kWh-weighted) reduction versus baseline consumption; confirmed previous studies that social comparisons elicit above average responses; showed, for the first time, that the so called boomerang effect in power consumption feedback projects can be explained by a previously hypothesized norm-conforming "magnet effect" (rather than a non-conforming defiance effect), thus substantially advancing the research in the field. (iii) Disaggregate apartment-level consumption to appliance level; because the hardware for electricity consumption unexpectedly allowed only for 10-second time resolution (rather than the 1-second resolution we had planned on), the disaggregation algorithms we developed on sample data could not be applied to the actual field data we collected. The project has yielded high visibility, with a total of 17 publications, from peer reviewed journals, published data sets (free access), blog posts, NY Times, National Public Radio, and CNN.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Demonstration of Microwave Cavity Transducer Performance in High Temperature Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment, which is similar to that of an advanced reactor. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Outer diameter of the cylindrical cavity is approximately 3cm, and the thin wall is approximately 200µm thick. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Frequency shift of the cavity spectral response was obtained at room temperature and ambient pressure by gradually increasing water flow rate from 0 to 25GPM (gallons per minute). Corresponding monotonic increase of resonant frequency by several hundred KHz was observed. Next, a sodium flow rate sensing study was performed in a liquid sodium vessel at 340° C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗