Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “metallic glasses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Short and medium range structure in elastic deformation of metallic and covalent glasses

Here, we present a concise methodology to analyze structural response to the applied stress in amorphous solids, including metallic glasses (MG), glassy selenium, silica and polycarbonate, using high energy x-ray diffraction and atomic pair distribution function (PDF) analysis. To assess the structural anisotropy induced by applied axial stress, diffraction data were expanded into spherical harmonics. Using Bessel transformation, components of the structure function were converted into isotropic and anisotropic PDFs. The PDFs were compared to the expected model behavior for ideal elastic deformation to separate homogeneous affine strain from local non-affine strains. In metallic glass the range of non-affine deformation is limited to the nearest neighbor shell, suggesting local strain relaxation under stress that occurs even in the elastic regime. Beyond the second atomic shell strain is uniform. However, in glassy silica, polycarbonate and selenium strong local bonding inhibits local displacements and strain in short range order is accommodated by rotation of local units. Interestingly, beyond a molecular unit, deformation in covalent systems is similar to MG, and response of the medium range order scales with the macroscopic stress.

glassy structure↗

Liquid drop technique for generation of organic glass and metal shells

It was found that liquid drop techniques are very useful in several diverse areas. For producing very uniform metallic, organic, inorganic and, on particular, glassy shells, the liquid jet method is the most reproducible and exceptionally useful of all the techniques studied. The technique of capillary wave synchronization of the break-up of single and multiple component jets was utilized to produce uniform sized liquid drops and solid particles, and hollow liquid and solid shells. The technique was also used to encapsulate a number of liquids in impermeable spherical shells. Highly uniform glass shells were made by generating uniform drops of glass forming materials in an aqueous solution, subsequently evaporating the water, and then fusing and blowing the remaining solids in a high temperature vertical tube furnace. Experimental results are presented and the critical problems in further research in this field are discussed.

Hendricks, C. D.↗

Direct observation of 3D atomic packing in monatomic amorphous materials

Liquids and solids are two fundamental states of matter. Although the structure of crystalline solids has long been solved by crystallography, our understanding of the 3D atomic structure of liquids and amorphous materials remained speculative. In 1952, Frank hypothesized that icosahedral order is the prevalent atomic motif in monatomic liquids. Over the past six decades, there have been a great deal of experimental, computational and theoretical studies to understand the structure of liquids and amorphous materials. A polytetrahedral packing model was proposed to explain the 3D atomic structure of monatomic liquids and amorphous materials, in which icosahedral order is a key feature. The icosahedral order has also been found to play an important role in the structure of metallic glasses and quasicrystals. Here we advance atomic electron tomography to determine for the first time the 3D atomic positions in monatomic amorphous materials, including a Ta thin film and two Pd nanoparticles. Despite the different chemical composition and synthesis methods, we observe that pentagonal bipyramids are the most abundant atomic motifs in these amorphous materials. Contrary to the traditional understanding, the pentagonal bipyramids do not assemble full icosahedra, but are closely connected with each other to form networks that extend to medium-range scale. Our molecular dynamic simulations, coupled with experimental results, further reveal that the 3D atomic structure of monatomic liquids is similar to the experimental amorphous material. Moreover, we find that the pentagonal bipyramid networks, prevalent in monatomic liquids, rapidly grow in size and form a fraction of full icosahedra during the quench from a liquid to a metallic glass state, providing a possible new picture of structural evolution through the glass transition.

Yuan, Yakun↗

Thermal contacts between metal and glass for use at cryogenic temperatures

Thermal contacts designed to cool a 50-cm diam fused-silica mirror to 5 K without serious distortion of the optical surfaces were tested. Rubber cement and copper-filled rubber cement were found to be well suited for maintaining thermal contact between the fused-silica and copper straps. A variety of other adhesives proved to be unreliable because they spalled the glass. The thermal resistances of the rubber cement and copper-filled rubber cement were determined. For the copper-filled rubber cement, the thermal resistances varied from 570 K/W at 60 K to 15,000 K/W at 10 K.

Obrien, K.↗

X-ray diffraction studies of phase transformations in heavy-metal fluoride glasses

Powder X-ray diffraction and differential scanning calorimetry studies of the crystallization properties of five ZrF4-based glass compositions have indicated that the crystalline phase in Zr-Ba-La-Pb fluoride glass is beta-BaZrF6; no such identification of crystal phases was obtainable, however, for the other glasses. Reversible polymorphic phase transformations occur in Zr-Ba-La-Li and Zr-Ba-La-Na fluoride glasses, upon heating to higher temperatures.

Bansal, N. P.↗

Thermally-Activated Metal-to-Glass Bonding

Hermetic seals formed easily by use of metallo-organic film. Metallo-organic film thermally bonded to glass and soldered or welded to form hermetic seal. Film applied as ink consisting of silver neodecanoate in xylene. Relative amounts of ingredients selected to obtain desired viscosity. Material applied by printing or even by scribing with pen. Sealing technique useful in making solar-cell modules, microelectronic packages, and other hermetic silicon devices.

Gallagher, B. D.↗

Crystallization of heavy metal fluoride glasses

The kinetics of crystallization of a number of fluorozirconate glasses were studied using isothermal and dynamic differential scanning calorimetry and X-ray diffraction. The addition of the fluorides LiF, NaF, AlF3, LaF3 to a base glass composition of ZrF4-BaF2 reduced the tendency to crystallize, probably by modifying the viscosity-temperature relation. ZrF4-BaF2-LaF3-AlF3-NaF glass was the most stable against devitrification and perhaps is the best composition for optical fibers with low scattering loss. Some glasses first crystallize out into metastable beta-BaZr2F10 and beta-BaZrF6 phases, which transform into the most stable alpha-phases when heated to higher temperatures. The size of the crystallites was estimated to be about 600 A from X-ray diffraction.

Bansal, Narottam P.↗

Hermetic Glass-To-Metal Seal For Instrumentation Window

Proposed mounting scheme for optical element of instrumentation window in pressure vessel ensures truly hermetic seal while minimizing transmission of stress to optical element. Brazed metal seal superior to conventional gaskets of elastomer, carbon, asbestos, or other material compressed between optical element and wall of vessel. Concentric brazed joints in proposed seal bond metal ring to wall of vessel and to optical element. U-shaped cross section allows ring to flex under pressure.

Hill, Arthur J.↗

Raman and Photoluminescence Spectroscopy of Er(3+) Doped Heavy Metal Oxide Glasses

The potential applications of rare-earth ion doped materials include fiber lasers which can be pumped conveniently by infrared semiconductor laser diodes. The host material systems most widely studied are fluoride crystals and glasses because fluorides have low nonradiative relaxation rates due to their lower phonon energies. However, the mechanical strength, chemical durability and temperature stability of the oxide glasses are generally much better than fluoride glasses. The objective of this research was to investigate the optical and spectroscopic properties of Er(3+)-doped lead-germanate and lead-tellurium-germanate glasses. The maximum vibrational energy of lead-tellurium-germanate glasses are in the range of 740-820/cm, intermediate between those of silicate (1150/cm) and fluoride (530/cm) glasses.

Dyer, Keith↗

Commercial Production of Heavy Metal Fluoride Glass Fiber in Space

International Space Station Alpha (ISSA) will provide a platform not only for materials research but also a possible means to produce products in space which cannot be easily produced on the ground. Some products may even be superior to those now produced in unit gravity due to the lack of gravity induced convection effects. Our research with ZrF4-BaF2-LaF3-AlF3-NaF (ZBLAN glass) has shown that gravity does indeed play a major role in the crystallization behavior of this material. At the present time ZBLAN is being produced on earth in fiber optic form for use in surgical lasers and fiber optic lasers among other applications. High attenuation coefficients, however, have kept this material from being used in other applications such as long haul data transmission links. The high attenuation coefficients are due to impurities which can be removed through improved processing techniques and crystals which can only be removed or prevented from forming by processing in a reduced gravity environment.

Tucker, Dennis S.↗

Tissue Photolithography

Tissue lithography will enable physicians and researchers to obtain macromolecules with high purity (greater than 90 percent) from desired cells in conventionally processed, clinical tissues by simply annotating the desired cells on a computer screen. After identifying the desired cells, a suitable lithography mask will be generated to protect the contents of the desired cells while allowing destruction of all undesired cells by irradiation with ultraviolet light. The DNA from the protected cells can be used in a number of downstream applications including DNA sequencing. The purity (i.e., macromolecules isolated form specific cell types) of such specimens will greatly enhance the value and information of downstream applications. In this method, the specific cells are isolated on a microscope slide using photolithography, which will be faster, more specific, and less expensive than current methods. It relies on the fact that many biological molecules such as DNA are photosensitive and can be destroyed by ultraviolet irradiation. Therefore, it is possible to protect the contents of desired cells, yet destroy undesired cells. This approach leverages the technologies of the microelectronics industry, which can make features smaller than 1 micrometer with photolithography. A variety of ways has been created to achieve identification of the desired cell, and also to designate the other cells for destruction. This can be accomplished through chrome masks, direct laser writing, and also active masking using dynamic arrays. Image recognition is envisioned as one method for identifying cell nuclei and cell membranes. The pathologist can identify the cells of interest using a microscopic computerized image of the slide, and appropriate custom software. In one of the approaches described in this work, the software converts the selection into a digital mask that can be fed into a direct laser writer, e.g. the Heidelberg DWL66. Such a machine uses a metalized glass plate (with chrome metallization) on which there is a thin layer of photoresist. The laser transfers the digital mask onto the photoresist by direct writing, with typical best resolution of 2 micrometers. The plate is then developed to remove the exposed photoresist, which leaves the exposed areas susceptible to chemical chrome etch. The etch removes the unprotected chrome. The rest of the photoresist is then removed, by either ultraviolet organic solvent or over-development. The remaining chrome pattern is quickly oxidized by atmospheric exposure (typically within 30 seconds). The ready chrome mask is now applied to the tissue slide and aligned manually, or using automatic software and pre-designed alignment marks. The slide plate sandwich is then exposed to UV to destroy the DNA of the unwanted cells. The slide and plate are separated and the slide is processed in a standard way to prepare for polymerase chain reaction (PCR) and potential identification of cancer sequences.

Wade, Lawrence A.↗