Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurements fusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Uncovering acoustic signatures of pore formation in laser powder bed fusion

Abstract We present a machine learning workflow to discover signatures in acoustic measurements that can be utilized to create a low-dimensional model to accurately predict the location of keyhole pores formed during additive manufacturing processes. Acoustic measurements were sampled at 100 kHz during single-layer laser powder bed fusion (LPBF) experiments, and spatio-temporal registration of pore locations was obtained from post-build radiography. Power spectral density (PSD) estimates of the acoustic data were then decomposed using non-negative matrix factorization with custom $$\varvec{k}$$ k -means clustering (NMF $$\varvec{k}$$ k ) to learn the underlying spectral patterns associated with pore formation. NMF $$\varvec{k}$$ k returned a library of basis signals and matching coefficients to blindly construct a feature space based on the PSD estimates in an optimized fashion. Moreover, the NMF $$\varvec{k}$$ k decomposition led to the development of computationally inexpensive machine learning models which are capable of quickly and accurately identifying pore formation with classification accuracy of supervised and unsupervised label learning greater than 95% and 90%, respectively. The intrinsic data compression of NMF k , the relatively light computational cost of the machine learning workflow, and the high classification accuracy makes the proposed workflow an attractive candidate for edge computing toward in-situ keyhole pore prediction in LPBF.

36 MATERIALS SCIENCE↗

The phase-2 particle x-ray temporal diagnostic for simultaneous measurement of multiple x-ray and nuclear emission histories from OMEGA implosions (invited)

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as T e is negligibly affected by residual flows and other non-thermal effects unlike ion-temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The newly implemented phase-2 Particle X-ray Temporal Diagnostic (PXTD) utilizes four fast-rise (~15 ps) scintillator-channels with distinct x-ray filtering. Titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons (DTn) from OMEGA Cryo-DT implosions. High quality data have been collected from warm implosions at OMEGA. These data have been used to infer spatially integrated T e (t) with <10% uncertainty at peak emission. Nuclear and x-ray emission histories are measured with 10 ps relative timing uncertainty for x rays and DTn and 12 ps for x rays and deuterium- 3 He protons (D 3 Hep). A future upgrade to the system will enable spatially integrated T e (t) with 40 ps time-resolution from cryogenic DT implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring higher-order moments of neutron-time-of-flight data for cryogenic inertial confinement fusion implosions on OMEGA

Ion temperatures serve as an important diagnostic for inertial confinement fusion (ICF) implosions. In direct-drive ICF experiments on OMEGA, neutron-time-of-flight (nTOF) data are used to infer the ion temperature of the fusing plasma produced in the implosion experiment. The analysis of the nTOF data requires an assumption about the shape of the underlying source signal. Since the source nTOF signal is a near-replica of the neutron energy spectrum, an ideal Gaussian shape, corresponding to the neutron energy spectrum of a uniform temperature plasma, is routinely employed. However, spatial and temporal variations of the ion temperature in the plasma give rise to higher-order moments, which were first described by Munro [Nucl. Fusion 56, 036001 (2016)]. In this work, we show a simpler alternative analysis to derive moments of the neutron energy spectrum for a plasma with variations in ion temperature. We also present a revised analysis of measured nTOF signals that uses a model with an additional degree of freedom to take into account the effect of ion temperature variations on the shape of the spectrum. Compared to presently used nTOF analysis, the revised analysis yields on average ≈2× more accurate fits to the data and up to 15% higher ion temperatures for cryogenic experiments. As a result, we quantify the ion temperature inflation caused by radially symmetric fluid flows, which are present even in a symmetric implosion, and which serve as a lower bound on the ion temperature inflation in real implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The emissivities of liquid metals at their fusion temperatures

A survey of the literature through 1969 shows an almost total lack of experimental emissivity data for metals in the liquid state. The emissivities for several transition metals and various other metals and compounds in the liquid state at their fusion temperatures have been determined. The technique used involves electromagnetic levitation-induction heating of the materials in an inert atmosphere. The brightness temperature of the liquid phase of the material is measured as the material is heated through fusion. Given a reliable value of the fusion temperature, which is available for most pure substances, one may readily calculate an emissivity for the liquid phase at the fusion temperatures. Even in cases where melting points are poorly known, the brightness temperatures are unique parameters, independent of the temperature scale and measured for a chemically defined system at a fixed point. Better emissivities may be recalculated as better melting point data become available.

Bonnell, D. W.↗

Constraining Absolute Higgs Couplings using Vector Boson Fusion H to WW with FCC-hh

The absolute normalisation scale of Higgs couplings is difficult to determine in hadron colliders. An experimentally and theoretically clean way to establish the coupling scale is to measure the ratio of resonant Vector Boson Fusion $H \rightarrow WW^{*}$ production to non-resonant $qq \rightarrow qqWW$ because both the theoretical and detector response systematics all cancel to first order in the ratio. To set the scale of the sensitivity, a simple selection and fit is presented with gives a 1.8\% (1.9\%) statistical uncertainty on the ratio for a 100 (84) TeV FCC-hh at 30\,ab$^{-1}$, which would give a corresponding uncertainty on the $\kappa$ scale of 0.5-1\% depending on systematic effects and potential impacts of more sophisticated analysis.

Lipeles, Elliot [University of Pennsylvania] (ORCI↗

Proof-of-concept of a neutron time-of-flight ellipsoidal detector

The time-resolved measurement of neutrons emitted from nuclear implosions at inertial confinement fusion facilities is used to characterize the fusing plasma. Several significant quantities are routinely measured by neutron time-of-flight (nToF) detectors in these experiments. Current nToF detectors use scintillators as well as solid-state Cherenkov radiators. The latter has an inherently faster time response and can provide a co-registered γ-ray measurement as well as improved precision in the bulk hot-spot velocity. This work discusses a nToF ellipsoidal detector that also utilizes a solid-state Cherenkov radiator. The detector has the potential to achieve a fast instrument response function allowing for characterization of the γ-ray burn history as well as the ability to field the detector closer to the fusion source. Proof-of-concept testing of the nToF ellipsoidal detector has been conducted at the National Ignition Facility using commercial optics. A time-resolved neutron signal has been measured from the diagnostic. Preliminary simulations corroborate the results.

Jeet, J. (ORCID:0000000291091563)↗

Sensitive search for near-symmetric and super-asymmetric fusion-fission of the superheavy element Flerovium (Z=114)

Measurements of mass and angular distributions have been made for fission-like outcomes in reactions forming isotopes of flerovium (Z=114), using 48 Ca, 50 Ti, and 54 Cr projectiles. The dominant fast quasifission process, which masks the presence of fusion-fission, has minimum yield at the most backward angles, where the sensitivity to fusion-fission is thus highest. In fitting the backward angle mass spectra, only weak evidence for a component of super-asymmetric fission was found, but a near-symmetric fission component was consistently required for the 48 Ca + 244 Pu reaction, giving upper limit to the fusion probabilities P CN of ~10 -2 , ~5 times lower than previous results. P CN for the 50 Ti reaction was lower than 48 Ca, whilst no evidence of fusion-fission was found for the 54 Cr reaction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The emissivities of liquid metals at their fusion temperatures.

The emissivities for several transition metals and various other metals and compounds in the liquid state at their fusion temperatures have been determined in this laboratory. The technique used involves electromagnetic levitation-induction heating of the materials in an inert atmosphere. The brightness temperature of the liquid phase of the material is measured as the material is heated through fusion. Given a reliable value of the fusion temperature, which is available for most pure substances, one may readily calculate an emissivity for the liquid phase at the fusion temperature. Even in cases where melting points are poorly known, the brightness temperatures are unique parameters, independent of the temperature scale and measured for a chemically defined system at a fixed point.

Bonnell, D. W.↗

Comparison of Elastic Moduli of LPBF 316H Material Using RUS Measurements and Destructive Mechanical Testing

Preliminary results are presented on performing Resonance Ultrasound Spectroscopy (RUS) measurements on stainless steel 316 H fabricated using Laser Powder Bed Fusion (LPBF) additive manufacturing methods. The elastic constants determined using RUS measurements are compared to tensile tests and RUS measurements on wrought stainless steel 316 L. Good agreement is found between the RUS measurements and the mechanical testing results.

36 MATERIALS SCIENCE↗

A compact and portable gamma-ray spectrometer (GRASP) for inertial confinement fusion and basic science experiments

A compact and portable gamma-ray spectrometer has been designed to diagnose different components of the inertial confinement fusion-relevant γ-ray spectrum with energies between ∼3.7–17.9 MeV. The system is designed to be as compact as possible for convenient transportation and fielding in diagnostic ports on the OMEGA laser, the National Ignition Facility, and other photon-source facilities. The system consists of a conversion foil for Compton scattering in front of four magnetic spectrometer “arms,” each covering a different energy range and constructed out of cylindrical permanent magnet Halbach arrays. Monte Carlo simulations have been used to optimize and assess the performance of the conversion foil, and COSY INFINITY ion-optical simulations have been used to optimize the spectrometer magnets. The performance of the design is assessed for a simulated direct-drive γ-ray spectrum. Spanning its total γ-ray energy bandwidth and using a 1.7 mm thick boron conversion foil, the system’s total energy resolution and efficiency are ∼15.8%–4.5% and 5.4 × 10−7–3.7 × 10−7e−/γ, respectively, with room for improvement. Spectral γ-ray measurements will provide guidance to the inertial confinement fusion program toward achieving high-energy gain relevant to inertial fusion energy and enable new measurement capabilities for basic discovery science.

Instruments & Instrumentation↗

Neutron Yield of Thermo Scientific P385 D-T Neutron Generator vs . Current and Voltage

The Thermo Scientific P385 Neutron Generator is a compact neutron source, producing 14 MeV neutrons through the deuterium-tritium (DT) fusion reaction. It is important to measure and understand the dependence of the neutron production rate on the accelerator current and voltage. In this study we evaluated neutron production with an absolutely calibrated liquid scintillator neutron spectrometer (BTI N-Probe), an absolutely calibrated He-3 detector surrounded by HDPE shells (Detec Nested Neutron Spectrometer, NNS), and two uncalibrated ZnS fast neutron scintillators (EJ-410), for both A3082 and A3083 sealed tubes. Here we also modeled the neutron yield using the TRIM code, which calculates the trajectory and the energy loss of deuterons and tritons within the target. Experimental results showed an essentially linear dependence on beam current, as expected. A 3.59 ±0.08 power law dependence on the operating voltage was measured, in effective agreement with the modeled value of 3.5. A series of absolute NNS and N-Probe measurements, matched against MCNP calculations, showed that the A3083 and A3082 tubes provide a maximum neutron yield of 8.2 × 10 8 n/s and 4.7 × 10 8 n/s respectively, with estimated uncertainty of ±10%.We showed, through modeling, that tritium decay is not a significant consideration for tubes, such as these, with lifetimes of less than 10 years.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

National Ignition Campaign Data Analysis by an ICF Outsider

A simple DT burn model, with no alpha-particle warming feedback, using a combination of ICF inputs and the measured ion temperature, T, volume compression, C, ablator velocity, v, and burn width time, Δt, can reproduce the national-ignition campaign (NIC) fusion yields with a rms percent difference of ~40%. Analysis suggestion the fusion-yield reproducibility of NIC events with nominally identically measured T, C, v, and Δt is <30%. The highest fusion yields, at a fixed laser energy are obtained with depleted-uranium (DU) hohlraums and high-density carbon (HDC) ablators. Small diameter fit tubes (≤5 μm) enhance fusion yields by an average of 26±15% relative to 10-μm diameter fit tubes. A dependence of fusion yield on the diameter of the capsule relative to the diameter of the hohlraum is inferred for fixed T, C, v, and Δt. No evidence of conditions close to ignition, or alpha-particle warming is found in the existing NIC data with LEH< 2MJ. To obtain a predictive model for extrapolation proposes we map the T, C, and v into power laws as a function of LEH. The above mentioned extrapolatable model has a rms percent difference from the yields of the second half of the NIC of (56 ± 4)%. Higher (and significantly lower) DT temperatures are obtained with HDC ablators (and low-foot drives). The highest compressions are obtained via low-foot drives, but this does not compensate for the corresponding lower temperatures. An extrapolation of the presented model suggests significant alpha-particle heating at an LEH of ~5 MJ. It is hoped that others more familiar it the conditions needed for ignition will use to presented model to estimate the LEH required for ignition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Data-Fusion Method using Bayesian Approach to Enhance Raw Data Accuracy of Position and Distance Measurements for Connected Vehicles

Accurate positioning of vehicles is a critical element of autonomous and connected vehicle systems. Most of other studies heavily focused on enhancing simultaneous localization and mapping (SLAM) methods, i.e., constructing or updating a map of an unknown environment and tracking an object within the map. This paper provides a method that can, in addition to existing SLAM or relevant methods, enhance the raw measurements of position and distance. The basic idea of this study is to identify and update the error distribution of each data source by combining all available information. A Bayesian approach was incorporated to estimate and update the error distribution of individual data sources or sensors. The proposed method can be conducted in real-time environments, and a self-learning scheme determines whether enough data has been collected to further improve the accuracy of such measurements. The simulated experiments show that the proposed model noticeably improves the accuracy of position and distance measurements. Especially, the estimated biases of position coordinates and distance measures are very close to the biases of true error distributions, with the R-squared over 0.98. A similar approach can also be utilized to enhance accuracy of other sensors or measurements in connected vehicle or relevant systems, where multi-data sources are available.

Lim, Hyeonsup↗

A digital holography ex situ measurement characterization of plasma-exposed surface erosion from an electrothermal arc source

Digital holography has been proposed to fulfill a need for an imaging diagnostic capable of in situ monitoring of surface erosion caused by plasma–material interaction in nuclear fusion devices. A digital holography diagnostic for 3D surface erosion measurement has been developed at Oak Ridge National Laboratory with the goal of deployment on a plasma device. A proof-of-concept in situ demonstration is planned which would involve measurement of plasma erosion on targets exposed to an electrothermal arc source. This work presents the results of an ex situ characterization of the capability and limitations of holographic imaging of targets exposed to the arc source. Targets were designed to provide a fiducial for comparison of deformed and unaffected areas. The results indicated that the average net erosion was ~150 nm/plasma exposure, which is expected to be within the diagnostic’s measurement capacity. Surface roughness averages determined by holographic image analysis showed good agreement with measurements taken with a profilometer. Finally, the limit of the holography diagnostic’s x–y spatial resolution was characterized by comparison with scanning electron microscope imaging.

47 OTHER INSTRUMENTATION↗