Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “managed charging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Integrated Power Source Grant

Traditional spacecraft power systems incorporate a solar array energy source, an energy storage element (battery), and battery charge control and bus voltage regulation electronics to provide continuous electrical power for spacecraft systems and instruments. Dedicated power conditioning components provide limited fault isolation between systems and instruments, while a centralized power-switching unit provides spacecraft load control. Battery undervoltage conditions are detected by the spacecraft processor, which removes fault conditions and non-critical loads before permanent battery damage can occur. Cost effective operation of a micro-sat constellation requires a fault tolerant spacecraft architecture that minimizes on-orbit operational costs by permitting autonomous reconfiguration in response to unexpected fault conditions. A new micro-sat power system architecture that enhances spacecraft fault tolerance and improves power system survivability by continuously managing the battery charge and discharge processes on a cell-by-cell basis has been developed. This architecture is based on the Integrated Power Source (US patent 5644207), which integrates dual junction solar cells, Lithium Ion battery cells, and processor based charge control electronics into a structural panel that can be deployed or used to form a portion of the outer shell of a micro-spacecraft. The first generation Integrated Power Source is configured as a one inch thick panel in which prismatic Lithium Ion battery cells are arranged in a 3x7 matrix (26VDC) and a 3x1 matrix (3.7VDC) to provide the required output voltages and load currents. A multi-layer structure holds the battery cells, as well as the thermal insulators that are necessary to protect the Lithium Ion battery cells from the extreme temperatures of the solar cell layer. Independent thermal radiators, located on the back of the panel, are dedicated to the solar cell array, the electronics, and the battery cell array. In deployed panel applications, these radiators maintain the battery cells in an appropriate operational temperature range.

Source record↗

Dry Storage of Encapsulated Defective Fuel Rods at Doel 1 and 2 in Belgium - 17581

The project of removing all fissile and non-fissile material out of the spent fuel ponds of Belgian Doel power plant is on-going and in that framework, a solution was needed for evacuating all used fuel elements from Doel 1 and 2 storage pool, including Defective Fuel Assemblies (DFA) and Defective Fuel Rods (DFR). Following the moving out of storage pool, all used fuel elements are intended to be loaded in dry storage casks, this used fuel management option being the one implemented today in Belgium while waiting for final management. Synatom, in charge of all fuel cycle related activities for the nuclear power plants of Belgium and Engie-Electrabel, the operator of both Belgium power plants (Doel and Tihange), had then to find an industrial solution for emptying Doel 1 and 2 used fuel pool and loading DFR in dry storage casks. After having thoroughly reviewed the possible options for implementing dry storage of DFR, Synatom selected AREVA technology. It consists in: - encapsulating each DFR by loading the fuel rod in a capsule, drying the fuel rod using a process which allows to physically verify with high accuracy the residual water content inside the DFR, and welding the capsule, - assembling the capsules in a capsule canister (a skeleton with external dimensions similar to fuel assembly's) and - transferring this capsule canister along with intact fuel assemblies in an associated dry transport and storage (dual purpose) cask, as already used for interim storage of used fuel at Doel site. The French as well as the Belgian competent authorities are parties to the licensing process project. The purpose of the paper is to present the on-going industrial project related to dry storage of dried and encapsulated DFR - along with intact used fuel in dual purpose casks - at Doel 1 and 2 in Belgium, its challenges and progress. The paper presents: - why the drying method, welded capsule and associated cask is the best available technology for dry storage of DFR; - a focus on fuel assembly repair operations (initial step before encapsulation) per-formed in 2015 which consisted in successful extraction of four DFR from their original fuel assembly, using proven and experienced methods and tools; - in conclusion, an update of Doel 1 and 2 DFR dry storage project: reaching of major qualifications and licensing milestones and overview of the project perspectives. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enabling fast charging – Battery thermal considerations

Battery thermal barriers are reviewed with regards to extreme fast charging. Present-day thermal management systems for battery electric vehicles are inadequate in limiting the maximum temperature rise of the battery during extreme fast charging. If the battery thermal management system is not designed correctly, the temperature of the cells could reach abuse temperatures and potentially send the cells into thermal runaway. Furthermore, the cell and battery interconnect design needs to be improved to meet the lifetime expectations of the consumer. Each of these aspects is explored and addressed as well as outlining where the heat is generated in a cell, the efficiencies of power and energy cells, and what type of battery thermal management solutions are available in today’s market. Here, thermal management is not a limiting condition with regard to extreme fast charging, but many factors need to be addressed especially for future high specific energy density cells to meet U.S. Department of Energy cost and volume goals.

25 ENERGY STORAGE↗

Why accredit ISO/CEI 17025 a nuclear waste management laboratory? - 15112

When there is no storage, nor repository, available on a site, the entity in charge of nuclear waste management should find outlets in order to evacuate outside the site. Each outlet has his rules and waste acceptance criteria (packaging rules, physical/chemical/radiological criteria for example). Before you are able to evacuate your waste, an acceptance's process (or contract review) takes place. This process scans the entire measures implemented by the site in order to satisfy outlet's criteria. When the acceptance is obtained, shipments could be organized, and the process gets into an observation's phase. During this phase, the outlet could choose to inspect a finished nuclear waste package or to audit regularly the waste management process. In this last case, the outlet re-scans the entire documents and implemented measures. This audit lasts from one to several days. A way to tackle/approach the audit is to acknowledge, by a trusted third party (i.e. independent from the outlet), all or part of waste management system, in order to base one's reputation on this organism and win outlet's trust. For this purpose, the entity could choose certification or accreditation. Certification (ISO 9001 as often as not) aims at evaluating a system for managing the quality of one product or service. Accreditation (ISO 17025, for example) provides formal recognition for technical skills within a quality management system (clauses 5 and 4 of the ISO 17025 standard). In 2006, the LDM laboratory is the first French laboratory accredited, in accordance with ISO 17025 standard, for the characterization by gamma spectrometry on 100 L- and 200 L- radioactive waste drums (accreditation No 1-1712 - scope available on www.cofrac.fr). This accreditation allows the lab: - to update the quality management system, - to compile the entire technical file of the gamma-ray assay (description, evaluation of the uncertainties, calibration, proficiency testing programs, measurement procedures,...), - to pass previous identified constraints on to producers and nuclear waste package production, - to maintain permanent quality improvement loop, - to lighten the programs of outlets audits, through the acknowledgement of the technical competence of the laboratory to evaluate by gamma spectrometry the activity contained in our nuclear waste drums. On the other hand, the lab is re-evaluated periodically to ensure its continued compliance with requirements: within a 12 month's interval for an internal audit, with a 18 month's period for COFRAC (French sole official national accreditation body). Since 2006, the lab is accredited. His accreditation renewed in 2010. A new entire renewal audit is planned in 2015. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design Considerations of DC/DC Regulator for High-Power Dynamic Wireless Charging Systems

Due to fast fluctuating input voltage, dynamic wireless charging requires a post-regulator stage for battery charging control and management. This regulator stage has a high requirement on efficiency, size as well as control performance to ensure tight regulation and fast trainset. This paper addresses the control challenges by modeling the system and designing the compensator with input voltage feedforward control. In addition, high resolution PWM is implemented to improve transient performance and current balancing among the phases. Experimental results prove the effectiveness of the proposed schemes and validates 180 kW closed-loop 4-phase operation at 99% efficiency.

Xue, Lincoln↗

Improving Deployment Availability of Energy Storage With Data-Driven AGC Signal Models

Energy Storage (ES) provides great flexibility and large benefits to power system operations and control. When providing ancillary services (e.g., regulation, reserve, etc.), the real-time (RT) deployment of ES is uncertain, and it is important to manage state of charge accordingly. Aiming to improve the ES performance for providing energy and regulation service in the electricity market, we propose two data-driven Automatic Generation Control (AGC) signal models. The first one is a historical-data-driven AGC signal model, which is based on the analysis of the historical AGC signals, and is designed for ES participation in the day-ahead (DA) market. The second one is a prediction-data-driven AGC signal model, which is based on the prediction of the AGC signals, and is designed for ES participation in the RT market. We also develop a deployment availability check model and solution algorithm. The proposed framework is applied to an ES bidding problem in the DA and RT markets. The results indicate that deployment availability and operational performance of the ES are improved with the proposed data-driven AGC models compared to traditional benchmarks.

AGC signal model↗

Secure Interoperable Open Smart Grid Demonstration Project

The Consolidated Edison, Inc., of New York (Con Edison) Secure Interoperable Open Smart Grid Demonstration Project (SGDP), sponsored by the United States (US) Department of Energy (DOE), demonstrated that the reliability, efficiency, and flexibility of the grid can be improved through a combination of enhanced monitoring and control capabilities using systems and resources that interoperate within a secure services framework. The project demonstrated the capability to shift, balance, and reduce load where and when needed in response to system contingencies or emergencies by leveraging controllable field assets. The range of field assets includes curtailable customer loads, distributed generation (DG), battery storage, electric vehicle (EV) charging stations, building management systems (BMS), home area networks (HANs), high-voltage monitoring, and advanced metering infrastructure (AMI). The SGDP enables the seamless integration and control of these field assets through a common, cyber-secure, interoperable control platform, which integrates a number of existing legacy control and data systems, as well as new smart grid (SG) systems and applications. By integrating advanced technologies for monitoring and control, the SGDP helps target and reduce peak load growth, improves the reliability and efficiency of Con Edison’s grid, and increases the ability to accommodate the growing use of distributed resources. Con Edison is dedicated to lowering costs, improving reliability and customer service, and reducing its impact on the environment for its customers. These objectives also align with the policy objectives of New York State as a whole. To help meet these objectives, Con Edison’s long-term vision for the distribution grid relies on the successful integration and control of a growing penetration of distributed resources, including demand response (DR) resources, battery storage units, and DG. For example, Con Edison is expecting significant long-term growth of DG. The SGDP enables the efficient, flexible integration of these disparate resources and lays the architectural foundations for future scalability. Con Edison assembled an SGDP team of more than 16 different project partners, including technology vendors, and participating organizations, and the Con Edison team provided overall guidance and project management. Project team members are listed in Table 1-1.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Direct Air Capture of Carbon Dioxide Using Nickel Hydroxide Batteries in a Membrane Electrode Assembly

Direct air capture (DAC) is a growing field responding to the need to remove carbon dioxide from the atmosphere. Several technologies are being developed today attempting to meet this need. The technology furthest in development are temperature swing adsorption technologies which have recently moved out of the pilot plant scale.1 This presentation looks to present an electrochemical device as alternative to these technologies. The electrochemical device proposed is a pair of nickel hydroxide (Ni(OH)2) battery electrodes which produce hydroxide (OH-). The hydroxide reacts with carbon dioxide (CO2) to create carbonate (CO32-) and bicarbonate (HCO3-). These carbonates can be transported from the cathode across an anion exchange membrane to the anode where they are evolved back into CO2 due to a pH reduction at the anode. This builds on work that optimized a Hydroxide Exchange Membrane Fuel Cell (HEMFC) for CO2 capture, showing the efficacy of an electrochemically mediated pH swing carbon capture device.2,3 The benefit of the nickel hydroxide battery approach is the low energy cost associated with separation. Because a pair of nickel hydroxide batteries undergo the same electrochemical reaction, low potentials, and thus low energy cost is required. Experiments have shown device level energy requirements of less than 1 MWh ton-1CO2. Most of the energy required by the device produces the pH gradient used to capture and release CO2. The biggest hurdle for this electrochemical approach is increasing the flux of CO2 to allow for more compact devices. Strategies for managing the transient charge and discharge behavior of the battery system will be discussed. Focus will be on improving flux to reduce the overall cost of the device.

Buchen, James↗

Design description of the Schuchuli Village photovoltaic power system

A stand alone photovoltaic (PV) power system for the village of Schuchuli (Gunsight), Arizona, on the Papago Indian Reservation is a limited energy, all 120 V (d.c.) system to which loads cannot be arbitrarily added and consists of a 3.5 kW (peak) PV array, 2380 ampere-hours of battery storage, an electrical equipment building, a 120 V (d.c.) electrical distribution network, and equipment and automatic controls to provide control power for pumping water into an existing water system; operating 15 refrigerators, a clothes washing machine, a sewing machine, and lights for each of the homes and communal buildings. A solar hot water heater supplies hot water for the washing machine and communal laundry. Automatic control systems provide voltage control by limiting the number of PV strings supplying power during system operation and battery charging, and load management for operating high priority at the expense of low priority loads as the main battery becomes depleted.

Ratajczak, A. F.↗

Observations of the artificially injected Porcupine xenon ion beam in the ionosphere

Results are given of ion beam injection experiments performed in the auroral ionosphere in connection with the German Sounding Rocket Project Porcupine. A heavy (xenon) ion beam was injected into the collisionless ionospheric plasma approximately perpendicular to the ambient magnetic field at altitudes from 190 km to about 450 km. The beam propagates nearly undistorted across the plasma because it is essentially depolarized; at the same time the beam is not current neutralized. This unexpected behavior poses the interconnected problems of how the beam manages to become charge neutralized, how current closure is maintained, and what is the mechanism of depolarization.

Haeusler, B.↗

TOPEX electrical power system

The TOPEX mission requirements which impact the power requirements and analyses are presented. A description of the electrical power system (EPS), including energy management and battery charging methods that were conceived and developed to meet the identified satellite requirements, is included. Analysis of the TOPEX EPS confirms that all of its electrical performance and reliability requirements have been met. The TOPEX EPS employs the flight-proven modular power system (MPS) which is part of the Multimission Modular Spacecraft and provides high reliability, abbreviated development effort and schedule, and low cost. An energy balance equation, unique to TOPEX, has been derived to confirm that the batteries will be completely recharged following each eclipse, under worst-case conditions. TOPEX uses three NASA Standard 50AH Ni-Cd batteries, each with 22 cells in series. The MPS contains battery charge control and protection based on measurements of battery currents, voltages, temperatures, and computed depth-of-discharge. In case of impending battery depletion, the MPS automatically implements load shedding.

Chetty, P. R. K.↗

Ground equipment for the support of packet telemetry and telecommand

This paper describes ground equipment for packet telemetry and telecommand which has been recently developed by industry for the European Space Agency. The architectural concept for this type of equipment is outlined and the actual implementation is presented. Focus is put on issues related to cross support and telescience as far as they affect the design of the interfaces to the users of the services provided by the equipment and to the management entities in charge of equipment control and monitoring.

Hell, Wolfgang↗

Spectral and Microclimate Measurements in Relation to Gold-Standard Methods Field Campaign Report

Arable is an agricultural data and analytics company offering an Internet of things (IOT)-enabled irrigation management tool, weather station, and crop monitor: the Arable Mark. The device synthesizes both climate and plant data to produce actionable insights on natural resource management, mainly commercial agriculture at any scale. Arable collected 11 months of microclimate and radiometric data at the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) observatory to compare measurements of the Arable Mark to the ARM-SGP gold-standard sensors, and for demonstrating the ease of installation and system value to stakeholders. A member from Arable labs installed the device on January 10, 2018, at the ARM facilities and the site managers were in charge of maintaining the sensors in a clean state until the unit’s removal on January 15, 2019. The sampling was positively uneventful, except for a period during the winter when the device stopped posting data for about one week. The verdict was that the equipment required an external solar panel to stay powered through the shorter days of winter. A solar panel was shipped to the SGP, and the unit came back to full charge to continue sending data for the rest of the sampling period. The main goal of the project is to use the data collected by the Arable Mark and build a model that can establish a close relationship with the current methodologies applied to measure ecosystem response to environmental changes. During the sampling period, our team discovered that there was a drift in some of the meteorological data and also in the radiometry, so all efforts are focused into the development of models that would reduce the errors in the reported values.

Southern Great Plains, evapotranspiration, photosy↗

Effect of thermal environments on fast charging Li-ion batteries

Battery thermal management systems (BTMSs) are expected to keep the battery temperature at a moderate level (~30 °C) to minimize the thermally exacerbated degradation. However, during fast charging, a strong cooling system is required to restrict the temperature rise of Li-ion batteries (LiBs), which significantly increases the cost and weight of battery packs, and induces a large temperature variation inside the battery. Here, in this work, we find that all these drawbacks could be relieved by allowing LiBs to charge at higher temperatures. Since the fast charging of a LiB only takes a tiny fraction of its lifetime, the aging rate is limited even at a charging temperature of 60 °C. Three types of thermal environments are proposed: kept constant at 30 °C, preheated to 60 °C, and adiabatic fast charging. With an experimentally validated electrochemical-thermal (ECT) coupled model, we explore the interplay between thermal management and the fast-charging performance. It is found that a gradually increasing temperature profile is the best option to balance the lithium plating and thermal management of the battery. Combining adiabatic fast charging with a preheating step, we can achieve minimal cooling need, perfect temperature uniformity within a battery, and fast-charging capability simultaneously.

25 ENERGY STORAGE↗

UV-LED Project

UV-LED is part of a small satellite technologydemonstration mission that willdemonstrate non-contacting charge controlof an isolated or floating mass usingnew solid-state ultra-violet light emittingdiodes (UV-LEDs). Integrated tothe Saudisat-4 spacecraft and launchedonboard the Dnepr in June 19, 2014,the project is a collaboration betweenthe NASA Ames Research Center (ARC),Stanford University, and King AbdulazizCity for Science and Technology(KACST). This technology demonstrationwill validate a novel method of chargecontrol that will improve the performanceof drag-free spacecraft allowingfor concurrent science collection duringcharge management operations as wellas reduce the mass, power and volumerequired while increasing lifetime and reliabilityof a charge management subsystem.These improvements are crucial tothe success of ground breaking missionssuch as LISA and BBO, and demonstratethe ability of low cost small satellite missionsto provide technological advancesthat far exceed mission cost.

Soulage, Michael↗

French Innovative Thermal Treatment Processes for The Management Radioactive Organic Liquid Waste - 19017

The nuclear industry as well as hospitals or some research laboratories produce Radioactive Organic Liquid Waste (ROLW) such as scintillation cocktails for medical imaging, labeled molecules for medical research or liquids from former activities. In order to be compatible with disposal facilities requirements, this waste must be inerted and stabilized in solid matrix. The route generally used is incineration in the Centraco facilities at the Marcoule site (Gard, France), ashes produced being cemented downstream. However, liquids whose chemical or radiological characteristics are not compatible with the incinerator operating rules (high level of {sup 14}C or halogen content, corrosive gas production etc.) cannot follow this path. The purpose of the MILOR project is then to propose alternative paths to treat all kinds of ROLW. Initiated in September 2017, this project has the technical objective of developing, over a four-year period, two pilot-scale mineralization processes. Two variants of complementary plasma technologies are evaluated: aerial plasma with the 'IDOHL' process and submerged plasma with the 'ELIPSE' process. Compared with other methods, thermal plasmas have unique characteristics such as rapid decomposition with high throughput, fast startup and shutdown, and high-energy delivery. The process called IDOHL consists of a process involving an induction plasma in which the liquids are directly introduced. It has been designed for organic liquids without mineral load and for treatment rates less than 0.5 l/h. This type of plasma allows the destruction of liquid organohalogens without any prior evaporation or treatment. Specific gas treatment systems have been developed to direct the gas produced to a dry or wet gas treatment system. One aim of the project is to subsequently install the process in a radioactive zone at Saclay DRF. The second called ELIPSE consists of a breakthrough process involving a submerged plasma at the heart of which organic liquids are also introduced. Current research has demonstrated that such a technique may enable the instantaneous and complete destruction of liquids with a wide variety of constituents, such as chlorine, fluorine, or phosphorus. The submersion solution offers many advantages: quenching and cleaning of combustion gases; filtering of the particles they contain; and cooling maintained for the entire process, which guarantees excellent corrosion control. An advantage of this type of design is that the gas treatment system can be reduced to a demister-condenser followed by a simple safety filter, thereby offering the additional advantage of an extremely compact treatment system. This design also allows the ELIPSE process to become by this way an embeddable process if required. The MILOR project, financed by the French State through investment program is a tripartite project bringing together Andra, in charge of radioactive waste management, the CEA in charge of leading scientific and technological researches to propose effective ways of treatment and the company A3i whose role is to ensure the subsequent industrial development. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Management of gas pressure and electrode state of charge in alkaline batteries

An inventive, new system that measures gas composition and pressure in the headspace of an aqueous electrolyte battery is described. The system includes a microcontroller that can use the composition and pressure information to connect a third electrode to either the anode(s) or the cathode(s) in order to balance the state of charge between the two. Results have shown that such a system can control the gas pressure inside a sealed flooded aqueous electrolyte battery to remain below 20 kPa (3 psi) and greatly extend the useable life of the battery.

25 ENERGY STORAGE↗