Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loss factor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Zeolite Degradation: An Investigation of CO2 Capacity Loss of 13x Sorbent

System testing of the Carbon Dioxide Removal and Compression System (CRCS) has revealed that sufficient CO2 removal capability was not achieved with the designed system. Subsystem component analysis of the zeolite bed revealed that the sorbent material suffered significant degradation and CO2 loading capacity loss. In an effort to find the root cause of this degradation, various factors were investigated to try to reproduce the observed performance loss. These factors included contamination by vacuum pump oil, o-ring vacuum grease, loading/unloading procedures, and operations. This paper details the experiments that were performed and their results.

Air Revitalization↗

Zeolite Degradation: An Investigation of CO2 Capacity Loss of 13x Sorbent

System testing of the Carbon Dioxide Removal and Compression System (CRCS) has revealed that sufficient CO2 removal capability was not achieved with the designed system. Subsystem component analysis of the zeolite bed revealed that the sorbent material suffered significant degradation and CO2 loading capacity loss. In an effort to find the root cause of this degradation, various factors were investigated to try to reproduce the observed performance loss. These factors included contamination by vacuum pump oil, o-ring vacuum grease, loadingunloading procedures, and operations. This paper details the experiments that were performed and their results.

ECLSS↗

Measurement of Dielectric Loss in Silicon Nitride at Centimeter and Millimeter Wavelengths

This work presents a suite of measurement techniques for characterizing the dielectric loss tangent across a wide frequency range from similar to 1 GHz to 150 GHz using the same test chip. In the first method, we fit data from a microwave resonator at different temperatures to a model that captures the two-level system (TLS) response to extract and characterize both the real and imaginary components of the dielectric loss. The inverse of the internal quality factor is a second measure of the overall loss of the resonator, where TLS loss through the dielectric material is typically the dominant source. The third technique is a differential optical measurement at 150 GHz. The same antenna feeds two microstrip lines with different lengths that terminate in two microwave kinetic inductance detectors (MKIDs). The difference in the detector response is used to estimate the loss per unit length of the microstrip line. Our results suggest a larger loss for SiNx at 150 GHz of tan delta similar to 4 x 10(-3) compared to 2.0 x 10(-3) and greater than or similar to 1 x 10(-3) measured at similar to 1 GHz using the other two methods. These measurement techniques can be applied to other dielectrics by adjusting the microstrip lengths to provide enough optical efficiency contrast and other mm/sub-mm frequency ranges by tuning the antenna and feedhorn accordingly.

Dielectrics loss↗

Ablation of ATJ Graphite at High Temperatures

Results of an extensive experimental program on the ablation of ATJ graphite in air at surface pressures of 0.3 to 4.4 atm and surface temperatures of 2570 to 4030 K are presented. The measured mass-loss rates are correlated with surface temperature, pressure, and effective nose radius. The results are compared with several equilibrium thermochemical ablation theories which differ basically in the chemical species that are considered and in the thermodynamic properties assigned to these species. All the theories predict about the same mass-loss rate in the diffusion-controlled oxidation regime and are in good agreement with the experimental results. At higher temperatures, however, the experimental and theoretical results do not agree. At temperatures above 3700 K, the experimental mass-loss rate becomes independent of pressure and an exponential function of temperature. A comparison of the high-temperature results with the theories indicates that all the theories, except the one based on the thermodynamic properties from the JANAF tables, are invalid because they overpredict the mass-loss rate. On the other hand, the theory based on the JANAF properties underpredicts the measured mass-loss rate by a factor of three at 4000 K. At least a portion of this difference between experiment and theory is attributed to particulate mass loss which is visually observed.

Thermochemical ablation↗

Developing A Custom-Built Metal Aerosol Processing Chamber: Analysis of Aerosol Coagulation at Low Humidities

We have developed an intermediate size (906 L) aerosol processing chamber, and this work reports on the design and initial characterization of dry aerosol experiments. Specifically, we are determining wall-loss and coagulation correction factors using the observed size distribution measurements for surrogates of common aerosol classes: sodium chloride, sucrose, and biomass burning aerosol smoke. Results show that, on average, sodium chloride, sucrose, and smoke wall-loss rates converge to similar values on relatively short time scales (< 1 h). The fitted coagulation correction factor, W C -1 , for smoke particles (1.23 ± 0.312), indicates that on average they adhere to each other more than sodium chloride (0.969 ± 0.524) and sucrose (1.16 ± 1.38). The relative uncertainty is high for the coagulation correction, but it is consistent with our Monte Carlo error analysis. This study lays the foundation for future experiments at elevated humidity and supersaturation conditions to characterize the influence of particle shape on coagulation and cloud parameters.

54 ENVIRONMENTAL SCIENCES↗

Cathode degradation and erosion in high pressure arc discharges

The various processes which control cathode erosion and degradation were identified and evaluated. A direct current arc discharge was established between electrodes in a pressure-controlled gas flow environment. The cathode holder was designed for easy testing of various cathode materials. The anode was a water cooled copper collector electrode. The arc was powered by a dc power supply with current and voltage regulated cross-over control. Nitrogen and argon were used as propellants and the materials used were two percent thoriated tungsten, barium oxide impregnated porous tungsten, pure tungsten and lanthanum hexaboride. The configurations used were cylindrical solid rods, wire bundles supported by hollow molybdenum tubes, cylindrical hollow tubes, and hollow cathodes of the type used in ion thrusters. The results of the mass loss tests in nitrogen indicated that pure tungsten eroded at a rate more than 10 times faster than the rates of the impregnated tungsten materials. It was found that oxygen impurities of less than 0.5 percent in the nitrogen increased the mass loss rate by a factor of 4 over high purity nitrogen. At power levels less than 1 kW, cathode size and current level did not significantly affect the mass loss rate. The hollow cathode was found to be operable in argon and in nitrogen only at pressures below 400 and 200 torr, respectively.

Hardy, T. L.↗

Cathode degradation and erosion in high pressure arc discharges

The various processes which control cathode erosion and degradation were identified and evaluated. A direct current arc discharge was established between electrodes in a pressure-controlled gas flow environment. The cathode holder was designed for easy testing of various cathode materials. The anode was a water cooled copper collector electrode. The arc was powered by a dc power supply with current and voltage regulated cross-over control. Nitrogen and argon were used as propellants and the materials used were two percent thoriated tungsten, barium oxide impregnated porous tungsten, pure tungsten and lanthanum hexaboride. The configurations used were cylindrical solid rods, wire bundles supported by hollow molybdenum tubes, cylindrical hollow tubes, and hollow cathodes of the type used in ion thrusters. The results of the mass loss tests in nitrogen indicated that pure tungsten eroded at a rate more than 10 times faster than the rates of the impregnated tungsten materials. It was found that oxygen impurities of less than 0.5 percent in the nitrogen increased the mass loss rate by a factor of 4 over high purity nitrogen. At power levels less than 1 kW, cathode size and current level did not significantly affect the mass loss rate. The hollow cathode was found to be operable in argon and in nitrogen only at pressures below 400 and 200 torr, respectively.

Hardy, T. L.↗

Performance of a high T(sub c) superconducting ultra-low loss microwave stripline filter

Discussed here is the successful fabrication of a five-pole interdigital stripline filter made of the 93-K superconductor (Y1Ba2Cu3O(y)) coated on a silver substrate, with center frequency of 8.5 GHz and an extremely high rejection ratio of 80 dB. The lowest insertion loss measured was 0.1 dB at 12 K, with a return loss of better than 16 dB, representing a significant improvement over a similar copper filter; it is comparable to low critical temperature filters. The insertion loss appears to be limited by extrinsic factors, such as tuning mismatch and joint losses, and not by the superconducting material losses.

Bautista, J. J.↗

Performance of a high Tc superconducting ultralow-loss microwave stripline filter

The successful fabrication is reported of a five-pole interdigital stripline filter made of the 93 K superconductor Y1Ba2Cu3O(y) coated on a silver substrate, with a center frequency of 8.5 GHz and an extremely high rejection ratio of 80 dB. The lowest insertion loss measured was 0.1 dB at 12 K, with a return loss better than 16 dB, representing significant improvements over a similar Cu filter, and comparable to low Tc filters. The insertion loss appears to be limited by extrinsic factors such as tuning mismatch and joint losses, and not by the superconducting material losses.

Zahopoulos, C.↗

Performance of a high T (sub c) superconducting ultra-low loss microwave stripline filter

Discussed here is the successful fabrication of a five-pole interdigital stripline filter made of the 93 K superconductor (Y1Ba2Cu3O sub y) coated on a silver substrate, with center frequency of 8.5 GHz and an extremely high rejection ratio of 80 dB. The lowest injection loss measured was 0.1 dB at 12 K, with a return loss of better than 16 dB, representing a significant improvement over a similar copper filter, and is comparable to low critical temperature filters. The insertion loss appears to be limited by extrinsic factors, such as tuning mismatch and joint losses, and not by superconducting material losses.

Bautista, J. J.↗

(Fe II) 1.53 and 1.64 micron emission from pre-main-sequence stars

We present flux-calibrated profiles of the (Fe II) 1.53 and 1.64 micron lines in five pre-main-sequence stars, PV Cep, V1331 Cyg, R Mon, and DG and HL Tau. The line centroids are blueshifted in all five sources, and four of the five have only blueshifted flux. In agreement with previous studies, we attribute the line asymmetries to local obscuration by dusty circumstellar disks. The absence of redshifted flux implies a minimum column density of obscuring material. The largest limit, N(sub H) greater than 3 x 10(exp 22)/sq cm, derived for V1331 Cyg, suggests disk surface densities greater than 0.05 g/sq cm and disk masses greater than 0.001 solar mass within a radius of approximately 200 AU. The narrow high-velocity lines in PV Cep, V1331 Cyg, and HL Tau require formation in well collimated winds. The maximum full opening angles of their winds range from less than 20 deg in V1331 Cyg to less than 40 deg in HL Tau. The (Fe II) data also yield estimates of the electron densities (n(sub e) approximately 10(exp 4)/cu cm), hydrogen ionization fractions (f(sub H(+)) approximately 1/3), mass-loss rates (approximately 10(exp -7) to 2 x 10(exp -6) solar mass/yr), and characteristic radii of the emitting regions (approximately 32 to approximately 155 AU). The true radial extents will be larger, and the mass-loss rates smaller, by factors of a few for the outflows with limited opening angles. In our small sample the higher mass stars have stronger lines, larger emitting regions, and greater mass-loss rates. These differences are probably limited to the scale and energetics of the envelopes, because the inferred geometries, kinematics and physical conditions are similar. The measured (Fe II) profiles samples both 'high'- and 'low'-velocity environments. Recent studies indicate that these regions have some distinct physical properties and may be spatially separate. The (Fe II) data show that similar sizes and densities can occur in both environments.

Hamann, Fred↗

Phase I for the Use of TOPEX-Poseidon and Jason-1 Radar Altimetry to Monitor Coastal Wetland Inundation and Sea Level Rise in Coastal Louisiana

The objective of the first phase of this project was to determine the feasibility of applying satellite altimetry data to monitor sea level rise and inundation within coastal Louisiana. Global sea level is rising, and coastal Louisiana is subsiding. Therefore, there is a need to monitor these trends over time for coastal restoration and hazard mitigation efforts. TOPEX/POSEIDON and Jason-data are used for global sea level estimates and have also been demonstrated successfully in water level studies of lakes, river basins, and floodplains throughout the world. To employ TOPEX/POSEIDON and Jason-1 data in coastal regions, the numerous steps involved in processing the data over non-open ocean areas must be assessed. This project outlined the appropriate methodology for processing non-open ocean data, including retracking and atmospheric corrections. It also inventoried the many factors in coastal land loss including subsidence, sea level rise, coastal geomorphology, and salinity levels, among others, through a review of remote sensing and field methods. In addition, the project analyzed the socioeconomic factors within the Coastal Zone as compared to the rest of Louisiana. While sensor data uncertainty must be addressed, it was determined that it is feasible to apply radar altimetry data from TOPEX/POSEIDON and Jason 1 to see trends in change within Coastal Louisiana since

Brozen, Madeline↗

Subcutaneous administration of insulin-like growth factor (IGF)-II/IGF binding protein-2 complex stimulates bone formation and prevents loss of bone mineral density in a rat model of disuse osteoporosis

Elevated serum levels of insulin-like growth factor binding protein-2 (IGFBP-2) and a precursor form of IGF-II are associated with marked increases in bone formation and skeletal mass in patients with hepatitis C-associated osteosclerosis. In vitro studies indicate that IGF-II in complex with IGFBP-2 has high affinity for bone matrix and is able to stimulate osteoblast proliferation. The purpose of this study was to determine the ability of the IGF-II/IGFBP-2 complex to increase bone mass in vivo. Osteopenia of the femur was induced by unilateral sciatic neurectomy in rats. At the time of surgery, 14-day osmotic minipumps containing vehicle or 2 microg IGF-II+9 microg IGFBP-2/100g body weight/day were implanted subcutaneously in the neck. Bone mineral density (BMD) measurements were taken the day of surgery and 14 days later using a PIXImus small animal densitometer. Neurectomy of the right hindlimb resulted in a 9% decrease in right femur BMD (P<0.05 vs. baseline). This loss in BMD was completely prevented by treatment with IGF-II/IGFBP-2. On the control limb, there was no loss of BMD over the 14 days and IGF-II/IGFBP-2 treatment resulted in a 9% increase in left femur BMD (P<0.05). Bone histomorphometry indicated increases in endocortical and cancellous bone formation rates and in trabecular thickness. These results demonstrate that short-term administration of the IGF-II/IGFBP-2 complex can prevent loss of BMD associated with disuse osteoporosis and stimulate bone formation in adult rats. Furthermore, they provide proof of concept for a novel anabolic approach to increasing bone mass in humans with osteoporosis.

NASA Discipline Regulatory Physiology↗

Effect of Torque-Tube Parameters on Rear-Irradiance and Rear-Shading Loss for Bifacial PV Performance on Single-Axis Tracking Systems

The emergence of cost-competitive bifacial PV modules has raised the question of the additional value of bifacial 1-axis tracking arrays, in particular when considering rear-irradiance losses from the tracker system itself. In this work, the effect of different geometries and materials of torque tubes is evaluated through ray-trace simulations and found to cause rear irradiance shading factors between 2% to 8% for systems without gap between the modules in 2-UP configuration. Inclusion of a gap between the modules can offset the shading factor. Electrical mismatch is also evaluated for the various configurations, and a methodology to apply shading factor and electrical mismatch loss to rear irradiance from the calculated loss in DC power, which averages 1% for the systems explored here, is proposed.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Precision Measurement of the Microwave Dielectric Loss of Sapphire in the Quantum Regime with Parts-per-Billion Sensitivity

Dielectric loss is known to limit state-of-the-art superconducting qubit lifetimes. Recent experiments imply upper bounds on bulk dielectric loss tangents on the order of 100 parts per billion but because these inferences are drawn from fully fabricated devices with many loss channels, these experiments do not definitely implicate or exonerate the dielectric. To resolve this ambiguity, we devise a measurement method capable of separating and resolving bulk dielectric loss with a sensitivity at the level of 5 ×10 –9 . The method, which we call the dielectric dipper, involves the in situ insertion of a dielectric sample into a high-quality microwave cavity mode. Smoothly varying the participation of the sample in the cavity mode enables a differential measurement of the dielectric loss tangent of the sample. The dielectric dipper can probe the low-power behavior of dielectrics at cryogenic temperatures and does so without the need for any lithographic process, enabling controlled comparisons of substrate materials and processing techniques. We demonstrate the method with measurements of sapphire grown by edge-defined film-fed growth (EFG) in comparison to high-grade sapphire grown by the heat-exchanger method (HEMEX). For EFG sapphire, we infer a bulk loss tangent of 63⁢(8) ×10 –9 and a substrate-air interface loss tangent of 15⁢(3) ×10 –4 (assuming a sample surface thickness of 3 nm). For a typical transmon, this bulk loss tangent would limit device quality factors to Q ≲20 ×10 6 , suggesting that bulk loss is likely the dominant loss mechanism in the longest-lived transmons on sapphire. We also demonstrate this method on HEMEX sapphire and bound its bulk loss tangent to be less than 19⁢(6) ×10 –9 . As this bound is about 3 times smaller than the bulk loss tangent of EFG sapphire, the use of HEMEX sapphire as a substrate would lift the bulk dielectric coherence limit of a typical transmon qubit to several milliseconds.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low loss fiber-coupled volumetric interconnects fabricated via direct laser writing

Photonic integrated circuits (PICs) are vital for high-speed data transmission. However, optical routing is limited in PICs composed of only one or a few stacked planes. Further, coupling losses must be low in deployed systems. Previously, we developed the subsurface controllable refractive index via beam exposure (SCRIBE) technique to write accurate 3D gradient refractive index (GRIN) profiles within a mesoporous silica scaffold. Here, we apply SCRIBE to fabricate low loss, broadband, polarization insensitive, fiber-coupled, single-mode volumetric interconnects that include waveguides traversing arbitrary 3D paths. By seamlessly integrating mode-matching subsurface lenses and GRIN waveguide tapers, calibrating for positional writing errors, implementing multipass exposure, automating alignment, and switching to antireflection coated fibers, we reduced the insertion loss for a fiber-PIC-fiber interconnect from 50 to 2.14 dB, or 1.47 dB, excluding the fiber array’s loss. Further, we establish an upper bound of 0.45 dB loss per coupler. We report quality factors of 27,000 and 77,000 and bending losses of 6 and 3 dB/cm for 15 and 30 µm radii microrings, respectively. We also demonstrate Bézier escalators, polarization-rotating and polarization-splitting interconnects, and a seven-channel 25 µm pitch volumetric interconnect. The SCRIBE platform presents a clear path toward realizing 3D PICs with unique functionality.

Optics↗

A High-Efficiency Isolated PFC AC-DC Topology with Reduced Number of Semiconductor Devices

A new three-level isolated ac-dc power factor correction (PFC) topology with a minimum number of semiconductor devices is the focus of this paper. This topology provides a high input power factor (PF), soft-switching, and higher efficiency than existing isolated ac-dc converters. Furthermore, the proposed circuit has lower voltage rating requirements for the secondary side devices, which leads to a lower total cost and minimizes total converter losses. This article presents a theoretical analysis describing the complete characterization of this new topology, and experimental results on a 1-kW prototype showing high PF and efficiency throughout the operating range.

42 ENGINEERING↗

Rapid design of bacteriophage cocktails to suppress the burden and virulence of gut-resident carbapenem-resistant Klebsiella pneumoniae

Antibiotic use can lead to the expansion of multi-drug-resistant pathobionts within the gut microbiome that can cause life-threatening infections. Selective alternatives to conventional antibiotics are in dire need. Here, in this work, we describe a Klebsiella PhageBank for the tailored design of bacteriophage cocktails to treat multi-drug-resistant Klebsiella pneumoniae. Using a transposon library in carbapenem-resistant K. pneumoniae, we identify host factors required for phage infection in major Klebsiella phage families. Leveraging the diversity of the PhageBank, we formulate phage combinations that eliminate K. pneumoniae with minimal phage resistance. Optimized cocktails selectively suppress the burden of K. pneumoniae in the mouse gut and drive the loss of key virulence factors that act as phage receptors. Phage-mediated diversification of bacterial populations in the gut leads to co-evolution of phage variants with higher virulence and broader host range. Altogether, the Klebsiella PhageBank charts a roadmap for phage therapy against a critical multidrug-resistant human pathogen.

60 APPLIED LIFE SCIENCES↗