Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loading frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Dynamic consensus and extended high gain observers as a tool to achieve practical frequency synchronization in power systems under unknown time-varying power demand

In this paper, we consider the frequency synchronization problem in a network of lossless, connected, and network-reduced power system. Frequency synchronization is an important problem in power systems as frequency deviation can lead to degraded power quality, tripping of generators, etc. We present a load-estimator-based consensus algorithm in a network of fourth-order generator models that achieves practical frequency synchronization in the presence of unknown time-varying power demand. We do not assume that the demand is generated by a known model. We follow a multiple time-scale approach for the stability analysis. It is shown that synchronization is achieved for the case of constant power demand, by showing that the system is exponentially stable. Furthermore, for the case of time-varying power demand, we show the error trajectories are ultimately bounded, and the synchronization error is proportional to an upper bound on the derivative of the time-varying power demand. We simulate the controller performance on a four area network which is equivalent to the IEEE New England 39-Bus system.

42 ENGINEERING↗

Operation of Grid Forming Converters as Self Excited Induction Generators Under Non-Ideal Loading Conditions

Self-excited induction generators offer a robust solution for power production for standalone as well as grid-connected systems. In general, self-excited induction generators require excitation capacitors which make use of the machine magnetization characteristics for voltage build up process as well as operation at a specific frequency. In this paper, a self-excited induction machine is modeled with both the electrical and mechanical dynamics. This modeled virtual machine's dynamics are utilized for voltage build up process for a standalone photovoltaic converter connected to a local load for a microgrid application. The modeled machine's parameters are used from the name plate rating from the manufacturer. However, in a microgrid the accommodation of unbalanced and/or nonlinear harmonic rich load is a necessity, therefore, in this work the virtual self-excitation capacitors of the modeled machine are varied based on the machine characteristics. With the objective of ensuring harmonic free point of common coupling voltage, the modeled virtual self-excitation capacitors are varied to accomplish change in terminal frequency and the virtual load torque is varied to obtain voltage magnitude change. To verify the efficacy, the overall system is modeled in MATLAB/Simulink and PLECS domain and most important case studies are presented.

grid forming converters (GFM)↗

Develop and verify soil/structure interaction for pile/foundation interaction

Phase II of the Offshore Code Comparison Collaboration, Continued, with Correlation and unCertainty (OC6) project was used to verify the implementation of a new soil-structure interaction (SSI) model for use within offshore wind turbine modeling software. The REDWIN Macro-element model implemented and verified in this study enables a computationally efficient way to model the linear and nonlinear SSI problem, including hysteretic damping, of a monopile structure. The modeling approach was integrated into several modeling tools and a series of increasingly complex simulations was conducted using the IEA 10MW reference turbine mounted on a monopile support structure to verify the coupling between the tools and the REDWIN Macro-element SSI model. This campaign includes only numerical verification between various software and modeling approaches so no experimental measurements are available. The load cases (LC) considered include: LC1 – static response of the tower and substructure LC2 – frequency and mode-shape analysis of the tower and substructure LC3 – response of the tower and substructure due to wind-only loading LC4 – response of the tower and substructure due to wave-only loading LC5 – response of the tower and substructure due to wind and wave loading. Detailed properties of the modeled system are found in the following reference, “Bergua, Roger, Amy Robertson, Jason Jonkman, and Andy Platt. 2021. "Specification Document for OC6 Phase II: Verification of an Advanced Soil-Structure Interaction Model for Offshore Wind Turbines.” Golden, CO: National Renewable Energy Laboratory. NREL/TP-5000-79938. https://www.nlr.gov/docs/fy21osti/79938.pdf. Details on the results from the OC6 Phase II project can be found in the following reference, “Bergua R, Robertson A, Jonkman J, et al. OC6 Phase II: Integration and verification of a new soil–structure interaction model for offshore wind design.” Wind Energy. 2022;25(5):793-810. doi:10.1002/we.2698

17 WIND ENERGY↗

Validation of CFD simulations of the moored DeepCwind offshore wind semisubmersible in irregular waves

This article examines the use of computational fluid dynamics (CFD) simulations to predict the response of a floating wind platform to irregular-wave excitation. This work was conducted as part of the Reproducible CFD Joint Industry Project for Floating Offshore Wind Applications and involved verification across several participants and modeling tools and validation against experiments. The authors pay special attention to the uncertainties in both CFD results and experimental measurements. In this work, we perform detailed comparisons of the incident waves and the motion of a moored structure. The nonlinear, low-frequency resonance motion is of particular interest because it potentially drives the mooring and tower-base loads. The verification and validation study is partially successful in that the CFD simulations capture the low-frequency slow-drift motion well but underpredict the low-frequency pitch resonance. This underprediction can be attributed in part to the CFD incident waves, which showed some discrepancies with the experimental waves, especially around extreme events. The effects of the wave discrepancies are also estimated and investigated using a mid-fidelity OpenFAST model. Overall, the present study increases our confidence in using CFD simulations to predict the global performance of offshore wind platforms in irregular waves and to produce data for the calibration of lower-fidelity models.

17 WIND ENERGY↗

Experimental investigation of advanced turbine control strategies and load-mitigation measures with a model-scale floating offshore wind turbine system

To advance the control co-design of offshore wind energy systems, the authors perform basin-scale experiments with a fully instrumented and actuated floating offshore wind turbine model. The model consists of a 1:70 scale performance-matched model of the International Energy Agency Wind Technology Collaboration Programme 15-MW reference turbine atop the VolturnUS-S semisubmersible platform. The Reference OpenSource Controller provides real-time blade pitch and generator torque control. Here we aim to develop an open data set for the validation of numerical models in predicting the influence of turbine control and load-mitigation measures. For this purpose, we measure the effects of advanced turbine control features, including peak shaving and floating feedback as well as hull-based control using tuned mass dampers on the system. Overall, the results demonstrate measurable and consistent influences from the control and load-mitigation measures, thus confirming the usefulness as a validation data set. Peak shaving attenuates the response to wind turbulence at near-rated wind speed. Floating feedback reduces the load and platform pitch motion associated with the negative damping induced by blade pitch control. The tuned mass dampers also attenuate the system response near the targeted frequencies under suitable conditions. We also identify detrimental side effects of each load-mitigation measure.

17 WIND ENERGY↗

A Secure and Adaptive Hierarchical Multi-Timescale Framework for Resilient Load Restoration Using a Community Microgrid

Distribution system integrated community microgrids (CMGs) can partake in restoring loads during extended duration outages. At such times, the CMGs are challenged with limited resource availability, absence of robust grid support, and heightened demand-supply uncertainty. Here, this paper proposes a secure and adaptive three-stage hierarchical multi-timescale framework for scheduling and real-time (RT) dispatch of CMGs with hybrid PV systems to address these challenges. The framework enables the CMG to dynamically expand its boundary to support the neighboring grid sections and is adaptive to the changing forecast error impacts. The first stage solves a stochastic extended duration scheduling (EDS) problem to obtain referral plans for optimal resource rationing. The intermediate near-real-time (NRT) scheduling stage updates the EDS schedule closer to the dispatch time using new obtained forecasts, followed by the RT dispatch stage. To make the decisions more secure and robust against forecast errors, a novel concept called delayed recourse is designed. The approach is evaluated via numerical simulations on a modified IEEE 123-bus system and validated using OpenDSS and hardware-in-loop simulations. The results show superior performance in maximizing load supply and continuous secure distribution network operation under different operating scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tri-Level Linear Programming Model for Automatic Load Shedding Using Spectral Clustering

Traditional load shedding schemes can be inadequate in grids with high renewable penetration, leading to unstable events and unnecessary grid islanding. Although for both manual and automatic operating modes load shedding areas have been predefined by grid operators, they have remained fixed, and may be sub-optimal due to dynamic operating conditions. In this work, a distributed tri-level linear programming model for automatic load shedding to avoid system islanding is presented. Preventing islanding is preferred because it reduces the need for additional load shedding besides the disconnection of transmission lines between islands. This is crucial as maintaining the local generation-demand balance is necessary to preserve frequency stability. Furthermore, uneven distribution of generation resources among islands can lead to increased load shedding, causing economic and reliability challenges. This issue is further compounded in modern power systems heavily dependent on non-dispatchable resources like wind and solar. The upper-level model uses complex power flow measurements to determine the system areas to shed load depending on actual operating conditions using a spectral clustering approach. The mid-level model estimates the area system state, while the lower-level model determines the locations and load values to be shed. The solution is practical and promising for real-world applications.

Baquedano-Aguilar, Mario D.↗

Structural response reconstruction using a system-equivalent singular vector basis

Here, this paper develops a novel method for reconstructing the full-field response of structural dynamic systems using sparse measurements. The singular value decomposition is applied to a frequency response matrix relating the structural response to physical loads, base motion, or modal loads. The left singular vectors form a non-physical reduced basis that can be used for response reconstruction with far fewer sensors than existing methods. The contributions of the singular vectors to measured response are termed singular-vector loads (SVLs) and are used in a regularized Bayesian framework to generate full-field response estimates and confidence intervals. The reconstruction framework is applicable to the estimation of single data records and power spectral densities from multiple records. Reconstruction is successfully performed in configurations where the number of SVLs to identify is less than, equal to, and greater than the number of sensors used for reconstruction. In a simulation featuring a seismically excited shear structure, SVL reconstruction significantly outperforms modal FRF-based reconstruction and successfully estimates full-field responses with as few as two uniaxial accelerometers. SVL reconstruction is further verified in a simulation featuring an acoustically excited cylinder. Finally, response reconstruction and uncertainty quantification are performed on an experimental structure with three shaker inputs and 27 triaxial accelerometer outputs.

42 ENGINEERING↗

Ab Initio Molecular Dynamics Spectra for Characterization of Hydrated Al 2 O 3 Supported MoO x

The structure of supported MoO x /Al 2 O 3 catalysts is investigated using ab initio molecular dynamics (AIMD) and density-functional theory (DFT). Phase diagrams were computed to understand the hydroxylation coverage as a function of the temperature, H 2 O partial pressure, and MoO x loading. We relate the shifts in experimental Raman vibrational frequencies under hydrated conditions to hydrogen bonding interactions and the MoO x anchoring location. We showcase that the use of AIMD as a benchmark for DFT can provide insight into how, under certain hydrated conditions, DFT excels as an inexpensive method for computing vibrational frequencies, while, under dehydrated conditions, it is susceptible to the largest errors. Additionally, to facilitate the analysis of the hydroxyl region of experimental infrared spectra, we compute the power spectra of individual hydroxyls and see a strong relationship between OH stretching frequencies and the surrounding coordination environment, which are also impacted by anchored MoO x . Here, we compare computational and experimental IR and Raman spectra of catalysts synthesized herein under the same conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Caution on Using Tetrahydrofuran for Processing Crystalline Silica Samples From Engineered Stone for XRD Analysis

Abstract We conducted laboratory experiments to investigate a suspected effect of tetrahydrofuran (THF) on quantifying crystalline silica in samples collected from working with engineered stone when THF is used to process samples prior to the X-ray diffraction (XRD) analysis. Two groups of samples from grinding either engineered stone or granite were simultaneously taken from a laboratory testing system, with one group of samples using THF for processing and another group using muffle furnace for ashing. For each stone type, we also tested four levels of respirable dust loading on the samples by varying the grinding time from 1 to 8 min. Statistical analysis of the experimental results on crystalline silica contents of the two groups of samples showed that the difference between the two methods was not significant (P ≥ 0.05) for the granite at all four levels of respirable dust loading and for the engineered stone at the two levels of respirable dust loading greater than 0.5 mg. However, the crystalline silica content from using THF processing was significantly lower (P = 0.001) than that from using muffle furnace ashing for engineered stone when the respirable dust loading levels were less than 0.5 mg. For the engineered stone dust samples with grinding times of 1 and 2 min, the average respirable dust loading was about 0.19 and 0.34 mg, respectively; while the crystalline silica content from using THF processing was 30.9 and 21.5% lower than that from using muffle furnace ashing, respectively. Since most full-shift samples from field assessments in this industry are expected to have respirable dust loading less than 0.5 mg, muffle furnace or radio frequency plasma ashing should be specified as the preferred sample processing method instead of the THF processing method for quantification of crystalline silica when engineered stone is expected to present to avoid artificially reduced silica content values, which are likely caused by the reactions between THF and the resins in engineered stone.

Public, Environmental & Occupational Health↗

Interoperable, Inverter - Based Distributed Energy Resources Enable 100% Renewable and Resilient Utility Microgrids

As microgrids transition away from use of conventional generating resources and increasingly rely on renewable resources towards decarbonization goals, it is crucial to evaluate the capability inverter-based resources to provide microgrid stability and resilience. Particularly, microgrids with a high contribution of intermittent solar photo voltaic generation and higher load variability present unique challenges requiring fast voltage and frequency support. At the San Diego Gas & Electric Company(R) (SDG&E(R)) Borrego Springs Microgrid, a battery inverter was upgraded with grid-forming (GFM) capability to serve as island leader, transitioning responsibility away from diesel generators. An interoperable microgrid control scheme was developed, coordinating GFM and grid-following (GFL) inverters. Hardware-in-the-loop (HIL) simulations using relevant power and controller HIL interfaces between real-time simulators and field equipment are being conducted to de-risk field deployment.

battery energy storage↗

Inertia Estimation Under High Penetration of Inverter-based Resources

Many types of renewable energy sources, especially solar and wind generation, are connected to the electric grid through power-electronic-based interfaces (inverters). These inverter-based resources (IBRs) are mechanically decoupled from the grid, which reduces system inertia and thus may compromise its stability and reliability. In this study, we examine the impact of high penetration of IBRs on the power grid’s inertia. To achieve this, we intentionally introduce disturbances into a simulation case study, such as a step load change, to observe and record the system’s frequency responses. This study offers a nuanced understanding of how the integration of IBRs affects grid stability, and it provides essential guidance for future grid management and resilience strategies.

Yadav, Ajay↗

Quantifying Solar PV Variability at Multiple Timescales for Power Systems Studies: Preprint

Increasing penetration of solar photovoltaics (PV) has concerned power system operators about their ability to balance load and generation over multiple timescales and maintain acceptable frequency profile because of the variability and uncertainty associated with solar PV. This paper focuses on developing metrics to quantify solar PV variability at multiple temporal scales ranging from seconds to an hour to help power system operators and planners better understand and account for solar PV variability under high solar PV penetration. Fourier coefficients of solar irradiation spectrum and average size of solar irradiation ramps over a day are the two metrics that are used to quantity the variability. It is shown that by using the two metrics the days with highest and lowest solar irradiation variability can be identified, which is useful information for operations planning or long-term power system planning studies. The key findings of the paper are (i) single sensor-based variability quantification can significantly exaggerate the variability of a solar PV plant, particularly at seconds to 1-min temporal resolution, (ii) at 1-minute or lower temporal resolutions, single sensor-based variability quantification of an entire plant can be fairly accurate, with the accuracy increasing as the temporal resolution reduces from 1-minute to 1-hour, (iii) at each 1-minute and lower temporal resolutions, maximum solar irradiation ramps appear to be independent of the geographical location of the sensor, and (iv) significant reduction in solar PV plant variability over a region with multiple plants is possible at all temporal scales, but more high quality, high temporal resolution data is needed to quantify the reduction with high confidence.

photovoltaics↗

Penetration Bounds For Azimuthal Slot On Infinite Cylinder With Finite Length Backing Cylindrical Cavity

We examine coupling into azimuthal slots on an infinite cylinder with a infinite length interior cavity operating both at the fundamental cavity modal frequencies, with small slots and a resonant slot, as well as higher frequencies. The coupling model considers both radiation on an infinite cylindrical exterior as well as a half space approximation. Bounding calculations based on maximum slot power reception and interior power balance are also discussed in detail and compared with the prior calculations. For higher frequencies limitations on matching are imposed by restricting the loads ability to shift the slot operation to the nearest slot resonance; this is done in combination with maximizing the power reception as a function of angle of incidence. Finally, slot power mismatch based on limited cavity load quality factor is considered below the first slot resonance.

42 ENGINEERING↗

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY↗

Scalable, Physical Effects Measurable Microgrid for Cyber Resilience Analysis (SPEMMCRA)

The ability to advance state of the art automated protections for industrial control systems (ICS) has as a precursor in the ability to understand the tradeoff space. That is, to enable a cyber feedback loop in a control system environment you must first consider both the security mitigation available, the benefits and the impacts to the control system functionality when the mitigation is used. More damaging impacts could be precipitated that the mitigation was intended to rectify. This paper details networked ICS that controls a simulation of the frequency response represented with the swing equation. The microgrid loads and base generation can be balanced through the control of an emulated battery and power inverter. The simulated plant, which is implemented in Raspberry Pi computers, provides an inexpensive platform to realize the physical effects of cyber attacks to show the tradeoffs of available mitigatoins. This network design can include a commercial ICS controller to introduce real world implementation of feedback controls, and provides a scalable, physical effects measurable Microgrid for cyber resilience analysis (SPEMMCRA).

42 ENGINEERING↗

A Comprehensive Approach towards Multi-Objective EMI Filter Design Optimization in High-Frequency SiC-Based Motor Drives

With rapid penetration of high-frequency, highdensity power electronics into the industry, controlling the system generated EMI becomes one of the major design challenges. Designing practical optimized EMI filters require simultaneous consideration of multiple aspects - including electromagnetic couplings, magnetic materials, practical component parasitics and their impacts at high-frequencies, and also the overall manufacturing costs. The multi-dimensional nature of the problem often results in overcompensated designs that hurt the system efficiency and power density. This paper focuses on a comprehensive design platform (developed in MATLAB) towards designing high-density, optimized, highly efficient EMI filters by analyzing the generated noise spectrum and evaluating a vast array of potential solutions before outputting an optimized filter solution. The proposed tool includes database-based component selection, optimal topology selection, multistage filter design, overall optimization for volume, mass, cost and total loss. The proposed filter has been thoroughly evaluated in a PSIM simulation environment emulating the hardware in CRD300DA12EXM3, a 300kW three-phase inverter from Wolfspeed with an RL load representing a motor drive application. Furthermore, a 20kHz switching frequency is chosen and impacts of the motor high-frequency characteristics on the generated EMI noise spectrum of the overall system have been analyzed.

42 ENGINEERING↗

High-Penetration Microgrids Providing Grid Stability Using Frequency Watt Control

The U.S. grid is rapidly transitioning towards utilizing inverter-based renewable energy resources such as solar, wind, and batteries, reducing the carbon emission footprint. Inverter-based microgrid control architectures remain a critical focus to address power system stability issues in future high penetration markets lacking spinning generation assets. Idaho National Laboratory (INL) is researching an active layered inverter based frequency-Watt control scheme that provides distribution level stability in high-penetration markets where grid inertia is lacking. Hardware in the loop case study was implemented using INL’s Microgrid Testbed to combat scalable frequency deviations ranging from 60 Hz down to 50 Hz initialized by a hydropower model implementing step loads using a 540-kW grid emulator. Our research findings demonstrate the importance of distribution level, inverter-based active frequency-Watt controls utilizing a battery energy storage system (BESS) to provide adequate frequency support at the point of common coupling without major power infrastructure upgrades.

14 SOLAR ENERGY↗