Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Energy and Comfort Impacts of High Performance Facades in Office Buildings

Building facades have a major effect on energy use, occupant comfort, and well-being. Yet adoption of high-performance facades is often slowed by limited data and unclear cost benefits. To address this gap, Oak Ridge National Laboratory, in collaboration with the Facade Tectonics Institute, conducted whole-building energy simulations to evaluate fenestration technologies for small and medium office buildings across three weather locations: hot (Tampa, Florida, weather zone 2A), mixed (New York, New York, weather zone 4A), and cold (Rochester, Minnesota, weather zone 6A). The simulations included parametric variations in window-to-wall ratio (30%–70%), U-values (0.1–1 Btu/h∙ft 2 ∙°F), solar heat gain coefficients (0.2–0.8), and solar control strategies and devices (e.g., interior shades and switchable glazing). Performance metrics included annual cooling, heating, and total heating, ventilation and air-conditioning (HVAC) energy use intensity, as well as nonenergy factors such as useful daylight illuminance, glare frequency, and thermal comfort during typical office hours (8 a.m.–6 p.m.). Results indicate that cooling energy consumption is most sensitive to solar heat gain coefficient (SHGC) in hot weather, whereas heating energy consumption is strongly influenced by U-value in cold weather. Total HVAC reflects these trade-offs, showing up to 60% difference for a window in total HVAC energy use intensity between different combinations of U-value and SHGC. Daylight dimming generally reduces cooling loads but can increase heating demands in colder locations. Interior solar shades improve useful daylight and reduce discomfort glare, whereas switchable glazing delivers the largest cooling reductions in hot weather but may increase heating loads in winter by limiting passive solar gains. Thermal comfort improves with lower window-to-wall ratios and lower SHGC in hot locations and with lower U-values in cold locations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Load Profile Inpainting for Missing Load Data Restoration and Baseline Estimation

This paper introduces a Generative Adversarial Nets (GAN) based, Load Profile Inpainting Network (Load-PIN) for restoring missing load data segments and estimating the baseline for a demand response event. The inputs are time series load data before and after the inpainting period together with explanatory variables (e.g., weather data). Here, we propose a Generator structure consisting of a coarse network and a fine-tuning network. The coarse network provides an initial estimation of the data segment in the inpainting period. The fine-tuning network consists of self-attention blocks and gated convolution layers for adjusting the initial estimations. Loss functions are specially designed for the fine-tuning and the discriminator networks to enhance both the point-to-point accuracy and realisticness of the results. We test the Load-PIN on three real-world data sets for two applications: patching missing data and deriving baselines of conservation voltage reduction (CVR) events. We benchmark the performance of Load-PIN with five existing deep-learning methods. Our simulation results show that, compared with the state-of-the-art methods, Load-PIN can handle varying-length missing data events and achieve 15-30% accuracy improvement.

14 SOLAR ENERGY↗

Techno-Economic Assessment of Residential Heat Pump Integrated with Thermal Energy Storage

Phase change material (PCM)-based thermal energy storage (TES) can provide energy and cost savings and peak demand reduction benefits for grid-interactive residential buildings. Researchers established that these benefits vary greatly depending on the PCM phase change temperature (PCT), total TES storage capacity, system configuration and location and climate of the building. In this study, preliminary techno-economic performance is reported for a novel heat pump (HP)-integrated TES system using an idealized approach. A simplified HP-TES was modeled for 1 year of space heating and cooling loads for a residential building in three different climates in the United States. The vapor compression system of the HP was modified to integrate with TES, and all heat transfer to and from the TES was mediated by the HP. A single PCM was used for heating and cooling, and the PCT and TES capacity were varied to observe their effects on the building’s energy consumption, peak load shifting and cost savings. The maximum reduction in electric consumption, utility cost and peak electric demand were achieved at a PCT of 30 °C for New York City and 20 °C for Houston and Birmingham. Peak energy consumption in Houston, New York City, and Birmingham was reduced by 47%, 53%, and 70%, respectively, by shifting peak load using a time-of-use utility schedule. TES with 170 MJ storage capacity allowed for maximum demand shift from on-peak to off-peak hours, with diminishing returns once the TES capacity equaled the daily building thermal loads experienced during the most extreme ambient conditions.

25 ENERGY STORAGE↗

Atomically Dispersed Pentacoordinated‐Zirconium Catalyst with Axial Oxygen Ligand for Oxygen Reduction Reaction

Single-atom catalysts (SACs), as promising alternatives to Pt-based catalysts, suffer from the limited choice of center metals and low single-atom loading. Here, we report a pentacoordinated Zr-based SAC with nontrivial axial O ligands (denoted O-Zr-N-C) for oxygen reduction reaction (ORR). The O ligand downshifts the d-band center of Zr and confers Zr sites with stable local structure and proper adsorption capability for intermediates. Consequently, the ORR performance of O-Zr-N-C prominently surpasses that of commercial Pt/C, achieving a half-wave potential of 0.91 V vs. reversible hydrogen electrode and outstanding durability (92% current retention after 130-hour operation). Moreover, the Zr site shows good resistance towards aggregation, enabling the synthesis of Zr-based SAC with high loading (9.1 wt%). With the high-loading catalyst, the zinc-air battery (ZAB) delivers a record-high power density of 324 mW cm -2 among those of SAC-based ZABs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the effect of metal loading on the reducibility and redox chemistry of ceria supported Pd catalysts

The effect of Pd loading on the redox characteristics of a ceria support was examined using in situ Pd K-edge XAS, Ce L 3 -edge XAS and in situ X-ray diffraction techniques. Analysis of the data obtained from these techniques indicates that the onset temperature for the partial reduction of Ce(IV) to Ce(III), by exposure to H 2 , varies inversely with the loading of Pd. Whilst the onset and completion temperatures of the reduction of Ce(IV) to Ce(III) are different, both samples yield the same maximal fraction of Ce(III) formation independent of Pd loading. Furthermore, the partial reduction of Ce is found to be concurrent with the reduction of PdO and demonstrated that the presence of metallic Pd is necessary for the reduction of the CeO 2 support. Upon passivation by room temperature oxidation, a full oxidation of the reduced ceria support was observed. However, only a mild surface oxidation of Pd was identified. The mild passivation of the Pd is found to lead to a highly reactive sample upon a second reduction by H 2 . The onset of the reduction of Pd and Ce has been demonstrated to be independent of the Pd loading after a mild passivation with both samples exhibiting near room temperature reduction in the presence of H 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Controlled site coverage of strong metal–support interaction (SMSI) on Pd NP catalysts

Here, strong metal–support interaction catalysts have been shown to improve desired product selectivity at the cost of fractional rates due to active site coverage. The goal of this study was to determine if the active site coverage of metallic nanoparticles could be controlled to lower levels than have been previously reported in SMSI catalysts with the aim of improving the rate while maintaining high selectivity. 2Pd–XTi/SiO 2 (2 wt% Pd, X wt% Ti) strong metal–support interaction (SMSI) catalysts with Ti loadings between 0–1.0 wt% were synthesized to control Pd nanoparticle coverage. Calcination at 450 °C and reduction at 550 °C were sufficient for forming ~2 nm sized Pd particles in all catalysts. Increasing the Ti loading from 0.1 to 1.0 wt% increased the surface coverage from 40 to 85% at a fixed reduction temperature of 550 °C. The IR spectra of the SMSI catalysts were similar with a high fraction of linear bonded CO which was much higher than that of Pd nanoparticles of similar size. The SMSI overlayer could be removed by oxidation at 350 °C and re-reduction at 200 °C. EXAFS of the oxidized catalysts indicates that nearly full oxidation of the metallic nanoparticle was required to remove the SMSI overlayer. Oxidation temperatures from 30 to 300 °C partially oxidized the Pd nanoparticles and subsequent re-reduction at 200 °C partially decreases the SMSI coverage. The fractional surface coverage was determined by measuring the rate of propylene hydrogenation with and without the SMSI overlayer. Increasing the reduction temperature from 200 to 550 °C increased the SMSI coverage from 0 to 85% depending on the Ti loading and temperature. In conclusion, after reduction at 550 °C and oxidation at 350 °C, the range of coverages varied between ~10% with 0.1 wt% Ti after re-reduction at 300 °C and ~85% with 1 wt% Ti after reduction at 550 °C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Delivering Energy Efficiency and Grid Services for Commercial Buildings on an IoT-Platform: Field Evaluation Plan

In FY20, the Commercial Buildings Integration Program (CBI) within Building Technologies Office (BTO) has funded PNNL to conduct field evaluation of the AIRCx and intelligent load control (ILC) using an Internet-of-Things (IoT) platform, VOLTTRON. The primary goal of the project is to show that software solutions deployed and delivered through an IoT-platform can identify energy efficiency opportunities and manage peak load in commercial buildings. There are also two secondary goals: 1) show that the energy efficiency solutions will result in identification of significant savings (10% to 30%) opportunities as well as energy cost reductions (10% to 15%) by managing the peak load in commercial buildings, and 2) show that an IoT-based software solution is more cost-effective in meeting the Re-tuning mandates than traditional retro commissioning (RCx) and there is a pathway for broader adoption of this approach. This report details how the field evaluation will be conducted, including what enhancements will be made to the software technologies, how PNNL will recruit energy service providers, types of buildings where the technology will be evaluated, metric of success for the field evaluation, and how the metric of success will be measured.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Loading Single-Atom Catalyst via On-Surface Synthesis of a Metal-Covalent Organic Framework for Oxygen Reduction Reaction

The development of active catalysts with both high metal efficiency and use of earth abundant metals is the ultimate goal for advancing the required commercially viable and sustainable energy conversion technologies of the future. Metal-organic frameworks (MOFs) have emerged as promising candidates due to their high surface area and tunable active sites. Here, this study aims to fabricate a new type of high metal loading single-atom catalysts (SACs) based on 2D metal-organic covalent organic frameworks (MCOFs) with uniform, active and stable Fe-N 3 sites. The MCOFs were synthesized through an on-surface polymerization process using Fe and melamine as precursors. The polymerization steps were characterized using operando high-pressure scanning tunneling microscopy (HP-STM), in situ X-ray photoelectron spectroscopy (XPS), low-temperature STM (LT-STM), and computational calculations. The synthesized MCOFs demonstrated favorable adsorption and activation of O 2 at the Fe-N 3 sites, and it is predicted to be active for the oxygen reduction reaction (ORR). The surface chemistry and functionality of 2D MCOFs can be rationally designed by varying the metal atoms and organic linkers, offering a versatile platform for diverse applications.

25 ENERGY STORAGE↗

Role of dislocations on martensitic transformation temperatures and microstructure: A molecular dynamics study

Microstructure and defects strongly affect martensitic transformations in metallic alloys. Significant progress has been made in understanding the atomic-level processes that control the role of grain boundaries and precipitates in these solid-to-solid phase transformations. Yet, the role of dislocations and their structures on martensitic transformation temperature and the resulting microstructure remains unclear. Therefore, we used large-scale molecular dynamics simulations to study the forward and reverse transformation of a martensitic material modeled after Ni63Al37 under cyclic thermal loading. The simulations reveal that dislocations in the austenite phase act as one-dimensional seeds for the martensite phase, which is present at temperatures significantly above the martensite start value. We find a reduction in the dislocation density during cyclic thermal loading, which results in the increase in martensite and austenite transition temperatures, in agreement with experiments. Importantly, we extracted a critical martensitic nuclei size for developing stable domains and found that relatively low dislocation densities are needed to grow independent martensitic variants resulting in a multi-domain structure.

Physics↗

Synchronization and Rebound Effects in Residential Loads

Increasing fuel prices and capacity investment deferral place an increasing demand for peak reduction from distribution level systems. Residential and commercial devices, such as HVAC systems and water heaters, are increasingly involved in load control programs, and their use may generate synchronization and rebound effects, such as artificial peaks caused by device optimization. While there have been concerns over device synchronization, few studies quantify the extent of this effect with numerical values. In this study, we attempt to investigate whether control efforts result in device synchronization or rebound effects. We focus on three clustering methods – Ward’s clustering, Euclidean K-means, and Density-based spatial clustering of applications with noise – to evaluate the extent of synchronization of a fleet of water heaters and HVAC systems in Atlanta, Georgia. Our findings show that synchronization and rebound effects are present in the neighborhood’s water heaters, but none were found in the HVAC systems. Further, high usage water heaters are more susceptible to synchronization and rebound effects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Extended Low Load Boiler Operation to Improve Performance and Economics of an Existing Coal Fired Power Plant (Final Report)

The overall goal is to improve the performance and economics of existing coal fired power plants by extending low load boiler operation to lower loads than is currently achievable. The objective of this program is to develop and validate sensor hardware and analytical algorithms to lower plant operating expenses (OPEX) for the currently operating pulverized coal utility boiler fleet. Coal fired utility boilers are increasingly under grid dispatch pressure. In some cases, the coal fired cost of generation is noncompetitive with respect to natural gas generation and subsidized renewable sources. To remain profitable and remain fully compliant with existing environmental regulations, the installed coal fired fleet must find technologies which allow it to move into a more flexible cyclic load dispatch model. Today the installed coal fired utility fleet must be cost of generation competitive, fully emissions compliant, and responsive to the variability inherent in renewable energy generation sources. In the Phase I of the project, GE Steam Power, Inc. (GE) performed modeling of different operating scenarios for low load operation using an existing full plant dynamic model developed for a 660MW steam power plant. Sensors and analytic algorithms to enable a stable and steady coal supply for low load pulverizer operation were identified and tested at the Pulverizer Development Facility (PDF) at GE’s Clean Energy Center in Bloomfield, Connecticut. Sensors and analytic algorithms to enable stable combustion for low load operation were identified and tested at the 15 MWth Industrial Scale Burner facility (ISBF) at GE’s Clean Energy Center. A concept was developed to test the sensors and control algorithms, down selected after testing, at a full-scale coal fired power plant. A budget estimate was then developed, and the concept was implemented at an existing utility power plant. The specific objectives of the experimental work were to: • Identify and select sensors and analytic algorithms for monitoring coal pulverizer operation at lower loads to provide stable operation and appropriate coal fineness at lower coal throughput; Identify and select sensors and analytic algorithms for a Boiler Flame Stability Monitor to better balance air and fuel at each burner. This enables a reduction in a coal boiler’s safe low load power level while maintaining stable flame characteristics; Develop a concept in Phase I for low load operation of a full-scale power plant and develop a budget estimate for testing and execute the test plan at an existing plant in Phase II; Validate the capability of the extended low load boiler system to extend the minimum load operating point in a safe and reliable manner on an existing full-scale utility boiler. At the completion of this experimental study, GE has developed a set of sensors and analytic algorithms, down selected after testing, that have the potential to enable safe low load operation of a utility boiler. GE has also identified a host site for testing these identified sensors and analytic algorithms. GE has generated a full set of deliverables that provide sufficient information to proceed with the next step of testing at a host site. This includes a potential host site and budget estimate for concept testing at host site. In the Phase II of the project, a series of field tests were completed to validate the extended low load boiler operation, which consisted of detailed engineering, installation, commissioning, and testing the additional sensors and analytics for the coal-fired combustion system on an existing full-scale utility boiler. The optimization work has been supported by the host plant and endorsed by their engineering and operation staff.

01 COAL, LIGNITE, AND PEAT↗

Energy Efficiency Analysis and Grid Service Results for Commercial Buildings using the VOLTRON IoT Platform

In fiscal year 2021 (FY21), the Commercial Buildings Integration Program (CBI) within the Building Technologies Office (BTO), funded PNNL to conduct a field evaluation of the AIRCx and ILC using an Internet-of-Things (IoT) platform, VOLTTRON. The primary goal of the project is to show that software solutions deployed and delivered through an IoT-platform can identify energy efficiency opportunities and manage peak load (beyond the traditional demand response) in commercial buildings. There are also two secondary goals: 1) show that the energy efficiency solutions will result in identification of significant savings opportunities (10% to 30%) as well as energy cost reductions (10% to 15%) by managing the peak load in commercial buildings, and 2) show that an IoT-based software solution is more cost-effective compared to a manual process in meeting the Re-tuning/retro commissioning (RCx) mandates and there is a pathway for broader adoption of this approach. This report provides AIRCx and ILC results for two building located in District of Columbia managed by the energy service provider Intellimation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heliostat Consortium: Gap Analysis on Wind Load for Achieving a Fully Competitive Heliostat Industry

The Heliostat Consortium (HelioCon) Wind Load Subtask was initiated with the aim of bringing research work pertaining to wind load measurement, characterization, and prediction taking place across several tasks, including Advanced Manufacturing, Components and Controls, and Field Deployment. The cross-cutting wind load subtopic in the HelioCon roadmap report [1] highlighted standardized methods and tools that are needed for a more detailed understanding of the static and dynamic loads on a heliostat. This will enable cost reduction of wind-dependent heliostat components to avoid unnecessarily conservative, overly constrained designs and increase field efficiency/reliability, to reduce the risk of component failures due to high-wind events (>15 m/s). Gaps related to heliostat wind load include site characterization for wind measurements, critical load cases for heliostat design, turbulence impacts on heliostat tracking error, testing of heliostat array configurations, understanding spatial variation of maximum loads across the solar field, and heliostat field layout and operating strategies. The recommended highest-priority pathway as first steps taken by HelioCon to address these gaps are to develop site characterization guidelines for heliostat design and field load measurements.

Emes, Matthew (ORCID:0000000341474387)↗

Controlled One‐pot Synthesis of Nickel Single Atoms Embedded in Carbon Nanotube and Graphene Supports with High Loading

Abstract Single‐atom catalysts (SACs) have attracted much attentions due to the advantages of high catalysis efficiency and selectivity. However, the controllable and efficient synthesis of SACs remains a significant challenge. Herein, we report a controlled one‐pot synthesis of nickel single atoms embedded on nitrogen‐doped carbon nanotubes (NiSA−N−CNT) and nitrogen‐doped graphene (NiSA−N−G). The formation of NiSA−N−CNT is due to the solid‐to‐solid rolling up mechanism during the high temperature pyrolysis at 800 °C from the stacked and layered Ni‐doped g‐C 3 N 4 , g‐C 3 N 4 −Ni structure to a tubular CNT structure. Addition of citric acid introduces an amorphous carbon source on the layered g‐C 3 N 4 −Ni and after annealing at the same temperature of 800 °C, instead of formation of NiSA−N−CNT, Ni single atoms embedded in planar graphene type supports, NiSA−N−G were obtained. The density functional theory (DFT) calculation indicates the introduction of amorphous carbon source substantially reduces the structure fluctuation or curvature of layered g‐C 3 N 4 ‐Ni intermediate products, thus interrupting the solid‐to‐solid rolling process and leading to the formation of planar graphene type supports for Ni single atoms. The as‐synthesized NiSA−N−G with Ni atomic loading of ∼6 wt% catalysts shows a better activity and stability for the CO 2 reduction reaction (CO 2 RR) than NiSA−N−CNT with Ni atomic loading of ∼15 wt% due to the open and exposed Ni single atom active sites in NiSA−N−G. This study demonstrates for the first time the feasibility in the control of the microstructure of carbon supports in the synthesis of SACs.

Zhao, Shiyong↗

Optimal operation of multi-plant steam district heating systems for enhanced efficiency and sustainability

Despite their crucial role in supplying heat and power to universities, industries, and healthcare facilities, many steam-based district heating systems rely on outdated control methods. Among these, multi-central plant districts are particularly challenging due to the complexities of coordinating multiple plants, optimizing load distributions, and managing system downtime. In response, new operational strategies are developed to enhance the efficiency and sustainability of steam districts while utilizing existing resources. These strategies include reducing plant operational pressure without compromising the reliable supply to buildings and optimizing load allocation across multiple plants. The load allocation considers boiler part-load efficiency, runtime, network losses, and building pressure set points, and is compared with traditional multi-boiler controls. To support this exploration, new dynamic Modelica models are developed. In addition, methods to reduce modeling complexities are incorporated, enhancing their suitability for practical applications. A holistic district-wide analysis using a real university case study demonstrates a 4.7% fuel savings by lowering boiler operational pressure from 900 kPa to 600 kPa, along with a 13.3% reduction in condensation losses across the distribution network. Furthermore, the load allocation approach results in a 13.1% reduction in fuel consumption during peak winter periods and 15.3% during shoulder periods, with corresponding decreases in carbon emissions and fuel costs. This approach can also save maintenance costs by reducing the boiler runtime by 49.6%. In conclusion, this research underscores the benefits of retrofitting aging steam district heating systems, offering immediate operational improvements by enhancing efficiency, meeting regulatory compliance, and extending infrastructure lifespans while delaying costly overhauls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Aldehyde and Ketone Hydroboration Mediated by a Heterogeneous Single–Site Molybdenum–Dioxo Catalyst: Scope and Mechanistic Implications

Efficient hydroboration of aldehydes and ketones is demonstrated using a single-site MoO 2 catalyst supported on activated carbon. Under mild conditions with low catalytic loadings, the reaction exhibits chemoselectivity towards carbonyl reduction over halides, alkene, alkyne, nitrile, and ester groups, affording high yields of desired products. Furthermore, competition studies between aldehyde and ketone reduction using HBpin and HBcat indicate that HBpin preferably functionalizes aldehydes, while HBcat can functionalize either substrate under specific conditions. Mechanistic studies suggest that the reaction proceeds via the initial formation of a molybdenum-hydride species upon B–H activation and subsequent molybdenum-alkoxide species upon carbonyl activation by the Mo center. The experimental activation energy of 14.3 kcal/mol alignssatisfactorily with the DFT computed ΔH ≠ of 18.7 kcal/mol, further supporting the proposed mechanism. Combined experimental/computational analyses reveal that excess HBpin can possibly deactivate the catalyst. The presence of excess benzaldehyde efficiently mitigates deactivation by HBpin, providing significantly higher catalyst recyclability. Altogether, this non-toxic, air- and moisture-stable, active, and selective catalyst demonstrates significant potential for green processes.

08 HYDROGEN↗

Long-Range Metal–Sorbent Interactions Determine CO 2 Capture and Conversion in Dual-Function Materials

Carbon capture and utilization involve multiple energy- and cost-intensive steps. Dual-function materials (DFMs) can reduce these demands by coupling CO 2 adsorption and conversion into a single material with two functionalities: a sorbent phase and a metal for catalytic CO 2 conversion. The role of metal catalysts in the conversion process seems salient from previous work, but the underlying mechanisms remain elusive and deserve deeper investigation to achieve maximum utilization of the two phases. Here, for this work, preformed colloidal Ru nanoparticles were deposited onto a “NaOx”/Al 2 O 3 sorbent to prepare prototypical DFMs with controlled phases for CO 2 capture and hydrogenation to CH 4 . Ru addition was found to double the high-temperature CO 2 adsorption capacity by activating the “NaOx”/Al 2 O 3 sorbent phase during a reductive pretreatment step. Most importantly, low Ru loadings were sufficient to ensure maximum CO 2 adsorption and conversion. This was attributed to the key role of the metal–sorbent interactions, wherein Ru was required to hydrogenate strongly bound CO 2 on the “NaO x ”/Al 2 O 3 sorbent to CH 4 via the H 2 activated on Ru. This interaction facilitated rate-determining carbonate migration and subsequent hydrogenation at the metal–sorbent interface. Overall, Ru controlled the CO 2 hydrogenation reaction rate, while the “NaO x ”/Al 2 O 3 sorbent dictated the CO 2 uptake capacity. By controlling metal–sorbent interactions at the molecular level, we demonstrate the critical role of the two phases and their synergy, facilitating the design of DFMs with maximum CO 2 capture and conversion efficiency.

carbon capture↗

Cellulose Nanofibrils Dewatered with Poly(Lactic Acid) for Improved Bio-Polymer Nanocomposite Processing

Cellulose nanofibrils (CNFs) have theoretically ideal properties for bio-based composite applications; however, the incorporation of these materials into polymers is made challenging by the strong binding of water to CNFs and the irreversible agglomeration of CNFs during drying. Previous methods used “contact dewatering”, wherein the addition of wood flour (WF) to CNFs facilitated the mechanical removal of water from the system via cold pressing, which showed potential in producing dried CNF fibrils attached to wood fibers for biocomposite applications. In this work, the viability of contact dewatering with poly(lactic) acid (PLA) powder for PLA/CNF composites was evaluated. The energy efficiency of dewatering, preservation of nanoscale CNF morphology, and mechanical properties were examined by mixing wet CNFs with pulverized PLA at various loading levels, pressing water out of the system, and compression molding and shear mixing composites for testing. The most impressive results from this dewatering method were the preservation of micron-to-nanoscale fibers with high aspect ratios in PLA-CNF composites; increased strength and modulus of 1.7% and 4.2%, respectively, compared to neat PLA; equivalent or better properties than spray-dried nanocellulose at similar loading levels; and an 11-194x reduction in drying energy compared to spray-drying CNFs.

Chemistry↗