Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load balancing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

LEAKAGE CHARACTERISTICS OF A STEPPED BALANCE PISTON LABYRINTH SEAL IN SUPERCRITICAL CO2

In an integrally geared compressor, there is a net thrust load on the pinion shaft from gear loads and aerodynamic forces. The net thrust on the pinion is resolved with either a thrust bearing or a thrust collar (rider ring). As the pressure increases, this increases the aerodynamic force proportionally. In highpressure systems this can overwhelm the thrust bearing or thrust collar if thrust is mismanaged. In a recent test program for an sCO2 integrally geared compander (compressor/turbine), a balance piston was created on the opposite end of the turbine to provide an equalizing thrust; while this is not novel, the balance piston provided a test apparatus for measuring the leakage on a 20 tooth stepped labyrinth seal operating at pressures in excess of 250 bar (3600 psi). The stepped balance piston seal is a 20 tooth tooth-onrotor balance piston seal. This type of seal was selected since it was predicted to have substantially less leakage than a comparably sized straight through labyrinth seal. Comparisons between the two designs will be made, showing that the leakage of the stepped balance piston seal is considerably lower. The tooth clearance on the seal was selected to be 30 mils radial. While this seems large, a stack-up tolerance assessment showed that this magnitude of clearance was appropriate to prevent rotor stator contact. During the testing campaign, data was recorded showing the leakage across this stepped balance piston seal at pressures in excess of 250 bar (3600 psi) with a pressure ratio of 2. This leakage data was measured, and will be compared to leakage data predicted with CFD. Two measurement methods are presented for the stepped balance piston seal: an orifice plate and valve. The predicted seal leakage from a straight through seal was four times that of the predicted stepped labyrinth seal. The measured flow from the stepped seal was on the same order as the CFD prediction and offered adequate rotordynamic performance

wilkes, jason↗

Geographical variability of summer- and winter-dominant onshore wind

For each geographical region, one of the biggest challenges in reaching a zero-carbon grid is identifying sources of electricity that match the seasonal profile of the load. Summer-dominant solar electricity generation can often be balanced by winter-dominant wind electricity generation. Together with long-duration storage, balanced solar and wind generation are well positioned to provide reliable renewable electricity. However, in some locations the wind may not complement solar energy so well. For example, currently California's wind turbines produce more electricity during summer than winter, raising the question of whether all future wind plants in California will exhibit the same seasonality. As a response to this question, in this paper, we analyzed the generation from existing California wind plants and simulated potential onshore wind resource for the whole state using a metric that reflects the relative wind resource in winter. Our results indicate that the seasonality of the wind can vary for very small spatial difference with more than half of California showing stronger wind resource in the winter compared with the summer despite the current observation of the opposite trend. This study differentiates the seasonality of potential wind resources to inform the creation of a reliable, 100%-renewable-driven grid.

17 WIND ENERGY↗

Connected Loads – Grid Connected Appliances: Commercial Refrigeration System Fault Detection and Diagnostics

As one of the most energy-intensive end-uses in the commercial buildings sector, supermarkets consume around 50 kWh/ft 2 (or 537.6 kWh/m 2 ) of electricity annually, or more than 2 million kWh of electricity per year for a typical store. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40–60% of its total electricity usage and is equivalent to about 2–3% of the total energy consumed by commercial buildings in United States, or around 0.5 quadrillion Btu (or 0.53 quadrillion KJ). Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Current supermarket refrigeration systems rely on high global warming potential hydrofluorocarbon refrigerants. Reducing refrigerant usage or using environment friendly alternatives can result in significant climate benefits. Transcritical CO2 refrigeration systems have attracted more attention in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in commercial buildings such as supermarkets. The refrigeration system can also be adapted to handle flexible building loads and be integrated into grid response transactive control to balance the supply and demand of the electric grid. Even minor improvements in the efficiency and operational reliability of supermarket refrigeration systems can create significant value in terms of saving energy, improving food quality, protecting the environment, reducing carbon footprint, and enhancing electric grid resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Connected Loads – Grid Connected Appliances: Deployment IoT Solution for Fault Detection and Diagnostics

As one of the most energy-intensive end-uses in the commercial buildings sector, supermarkets consume around 50 kWh/ft 2 ( or 537.6 kWh/m 2 ) of electricity annually, or more than 2 million kWh of electricity per year for a typical store. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40–60% of its total electricity usage and is equivalent to about 2–3% of the total energy consumed by commercial buildings in United States, or around 0.5 quadrillion Btu (or 0.53 quadrillion KJ). Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Current supermarket refrigeration systems rely on high global warming potential hydrofluorocarbon refrigerants. Reducing refrigerant usage or using environment friendly alternatives can result in significant climate benefits. Transcritical CO2 refrigeration systems have attracted more attention in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in commercial buildings such as supermarkets. The refrigeration system can also be adapted to handle flexible building loads and be integrated into grid response transactive control to balance the supply and demand of the electric grid. Even minor improvements in the efficiency and operational reliability of supermarket refrigeration systems can create significant value in terms of saving energy, improving food quality, protecting the environment, reducing carbon footprint, and enhancing electric grid resilience. For decarbonization, the new administration has set a target to reduce greenhouse gas emissions by 50– 52% by 2030 and targeting a carbon-neutral economy by 2050. For electrification, the goal is to achieve 100% clean electricity by 2035. Such decarbonization and electrification in the building sector require that energy consumption in buildings be reduced significantly. Therefore, the building sector must continuously adopt new technologies to achieve its energy and carbon emission goals. One of the most fundamental technologies is the Internet of Things (IoT). IoT has proven to be an effective solution for the building domain, including building information/energy modeling, smart buildings, etc. Although much progress has been made in the development of IoT-based building energy systems, there is still a lack of reliable, scalable, and affordable IoT-based automated fault and degradation diagnostics (AFDDs) solutions. Such solutions would enable deployment of advanced algorithms into real systems to archive the projected energy benefits. This study reviews existing IoT solutions developed for building energy– related application and developed a simple but effective AFDD IoT deployment solution, including developing a suitable IoT architecture and conducting easy and scalable deployment by leveraging a common cloud-based IoT service.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lower Snake River Dams Contribution to Grid Services

Hydroelectric generation and water storage have long been components of the clean energy mix, providing both reliable steady output and operational flexibility. As variable renewable energy sources such as wind and solar increasingly replace traditional generation, the role of all flexible resources—including hydropower—in balancing supply and demand continues to evolve. This study examined the contribution of the Lower Snake River (LSR) Dam plants to Bonneville Power Administration grid services in maintaining power system reliability within the Western Interconnection. By analyzing publicly available data, the study evaluated various reliability services through performance metrics including energy capacity, balancing and ramping, voltage and reactive power support, frequency response, and transmission impact. Results indicated that the LSR plants deliver services as expected based on their size, contributing to the balancing process, ramping capabilities, and operational reserves, particularly during peak load conditions and weather events, while also providing measurable frequency and voltage support to the grid.

13 HYDRO ENERGY↗

EIA Form 714 Database

EIA Form 714 Annual Electric Balancing Authority Area and Planning Area Report Dataset

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sizing and Location Selection of Medium‐Voltage Back‐to‐Back Converters for DER‐Dominated Distribution Systems

Medium‐voltage back‐to‐back (MVB2B) converters can connect two distribution systems and quantifiably transfer power between them. This function can enable the MVB2B converter to exchange distributed energy resource (DER)‐generated power between two systems and bring significant value to enhancing distribution system DER adoption. Our previous work analysed and demonstrated the value MVB2B converter can bring to DER integration. As continuous work, this paper presents a methodology that helps address the MVB2B converter sizing and location selection problem in distribution systems with high DER penetrations. The proposed methodology aims to address three critical problems for MVB2B converter implementation in the real world: (1) which distribution systems are better to be connected, (2) what converter size is appropriate for connecting the distribution systems, and (3) where the optimal connection points are in the systems for connecting the MVB2B converter. The proposed methodology has been demonstrated by case studies that include various scenarios involving distribution systems with different dominated load types and high photovoltaic penetrations. The results demonstrate that selecting the optimal converter size based on net revenue and time of return considerations leads to a balance between maximizing energy savings and minimizing financial payback periods. Furthermore, feeder pair selection based on load profile standard deviation effectively identifies systems that derive the greatest value from MVB2B integration. Finally, an optimized connection point selection approach using a voltage load sensitivity matrix ensures minimal system impact while facilitating efficient power exchange. These findings provide practical insights for the real‐world deployment of MVB2B converters to enhance DER hosting capacity and improve grid resilience.

14 SOLAR ENERGY↗

Integrating Resilience Planning in Distribution System Planning

Electric utilities, regulators, and stakeholders face increasing risks of severe storms, freezes, floods, and heat waves damaging grid infrastructure and causing power outages—and increasing risks of utility equipment igniting wildfires. At the same time, customer electricity rates have risen substantially in recent years, due in part to replacing aging infrastructure and improving resilience to natural hazards and physical threats. To address these challenges, utilities are beginning to move beyond traditional, siloed planning processes to balance resilience with other fundamental grid objectives such as affordability, reliability, safety, and serving new loads. This study presents a framework for states and utilities that want to advance integration of resilience and distribution planning processes to improve planning efficiency, better prioritize cost-effective grid expenditures, and balance planning objectives. The framework includes 7 key integration points between these planning processes: -Strategy process -Data -Threat assessments -Solution identification and prioritization -Optimization opportunities -Consideration of other grid needs -Metrics Lawrence Berkeley National Laboratory reviewed utility distribution system plans and interviewed subject matter experts to identify emerging practices for each of the 7 integration points. This report presents these practices, which can be used as a guide toward more holistic planning and cohesive investment strategies. It also includes 3 case studies to provide practical examples of how utilities apply such integrated planning processes: two pole hardening programs and one microgrid planning effort. The report concludes by identifying opportunities for future research.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A large deformation multiphase continuum mechanics model for shock loading of soft porous materials

A large deformation, coupled finite-element (FE) model is developed to simulate the multiphase response of soft porous materials subjected to high strain-rate loading. The approach is based on the theory of porous media (TPM) at large deformations. Simplifications to the one-dimensional regime studied in the numerical simulations follow. An overview of several different time integration schemes is presented for the purpose of solving the nonlinear dynamic coupled balance of momenta (mixture and fluid) and balance of mass of the mixture equations. Numerical examples are presented for (i) verification against closed-form analytical solutions assuming small loads, (ii) demonstrating large deformation effects at high strain-rate, and (iii) showing differences in deformations between a single-phase elastodynamics model with occluded compressible pore fluid and a multiphase poroelastodynamics model at high strain-rate. The multiphase model shows that the relative motion of the pore fluid significantly dampens the deformation response of the solid skeleton as compared to the single-phase model, and makes it possible to extract quantitative values for the stresses of the different constituents, thereby allowing one to form preliminary conclusions about the onset of damage in the solid skeleton. The novelty of the current work is developing a multiphase, large deformation, mixture theory numerical model for high strain-rate loading of soft porous materials. It was discovered that explicit, adaptive time-stepping Runge–Kutta schemes offer high accuracy at relatively low cost when compared to traditional implicit or explicit central difference time-stepping schemes for shock-like loadings. Here, shock viscosity is added to the mixture momentum balance equation to regularize the shock front, and a stabilization term is added to the mixture mass balance equation to stabilize equal order interpolation finite elements for the coupled finite element solution of multiphase materials.

Engineering↗

Demonstrating Load-Shaping Capabilities of Cost Minimizing Heat Pump Water Heater Controls with Varying Price Profiles

Increased penetration of photovoltaics and electrification of traditionally gas appliances are exacerbating existing challenges in cost-effectively balancing electricity grid supply and demand. Decarbonization without incurring expensive transmission and distribution system capacity increases requires shifting building loads from peak demand times to peak renewable production times. Grid operators are evaluating new ways of encouraging load shifting, including using time-varying price structures to provide a financial incentive. If devices incorporate price-responsive controls, a price profile could be designed to yield a wide variety of load curves as needed to optimize grid functionality. Heat pump water heaters (HPWHs) are an ideal device for price-responsive controls because the storage tank enables them to optimize the timing of electricity consumption without impacting hot water delivery service. This paper presents work demonstrating how price-responsive controls for HPWHs can provide different load profiles, as needed to stabilize the grid, in response to different price profiles. HPWH manufacturers now include web API and CTA-2045 communication capabilities which enable sending load shaping control signals. Pilot studies and preliminary programs have utilized these capabilities with uniform control strategies to reduce 4-9 PM electricity consumption. However, no studies have developed flexible controls capable of both a) responding to constantly varying price profiles and b) customizing logic to match the needs of each HPWH. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls utilizing setpoint setting signals for fleets of HPWHs in response to varying price profiles. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of a residential, integrated HPWH manufacturer’s on-board controller. The proposed cost-reducing controls respond to constantly changing price profiles, providing the ability to change the price profile to generate load curves as needed to maintain grid stability. Preliminary simulations studying the load shaping capabilities of price-responsive controls on a fleet of 60 HPWHs have demonstrated an average of a) 135.4% increases in load during low-price periods, b) >36.8% reductions in electricity peak-price period, and c) 6.2% electricity cost savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing and Evaluating Metrics for Demand Flexibility in Buildings: Comparing Simulations and Field Data

Building demand flexibility (DF) has attracted significant attention in recent years among researchers, technology developers and control companies, aggregators, utilities, and many others. There are numerous challenges with today’s electricity systems such as managing peak demand capacity and integrating variable renewables into the grid. Flexible building loads can provide various grid services to help reduce electricity costs, smooth out renewables intermittency and balance supply and demand. Recognizing this, the US DOE is leading the Grid-interactive Efficient Buildings (GEB) initiative which includes research to evaluate the potential, availability and timing of flexible loads. In this paper we present load shed metrics for three building types – medium office, large office and retail store – and compare prototype simulation results with measured data from 12 actual buildings that participated in hot summertime utility demand response (DR) events. The DR strategies included varying zone temperature and reducing light levels. The magnitude of a key DF metric, “demand decrease intensity” (or “shed intensity”) (W/ft2), between the simulation results and field data are similar (14-32% differences) for both mean and median values, though the field data show much larger variation among DR events. The coefficient p-values from linear regression model tests showed that outside air temperature is a significant variable for the whole building shed intensity when the resetting zone temperature strategy is deployed. These findings support the concept of using prototype building simulation to estimate building DF and expanding future simulation research to additional building types and climate zones.

Liu, Jingjing↗

Comparison of Load Models for Estimating Electrical Efficiency in DC Microgrids: Preprint

This paper compares several electrical load models for estimating the efficiency of DC vs. AC distribution in microgrids. Candidate models include energy balance, harmonic power flow, and time-domain modeling. Model results are compared with numerical studies and validated with experimental measurements. Based on quantitative and qualitative considerations, the most appropriate load modeling approach for larger-scale DC distribution efficiency studies is proposed.

DC distribution↗

Extended Low Load Boiler Operation to Improve Performance and Economics of an Existing Coal Fired Power Plant (Final Report)

The overall goal is to improve the performance and economics of existing coal fired power plants by extending low load boiler operation to lower loads than is currently achievable. The objective of this program is to develop and validate sensor hardware and analytical algorithms to lower plant operating expenses (OPEX) for the currently operating pulverized coal utility boiler fleet. Coal fired utility boilers are increasingly under grid dispatch pressure. In some cases, the coal fired cost of generation is noncompetitive with respect to natural gas generation and subsidized renewable sources. To remain profitable and remain fully compliant with existing environmental regulations, the installed coal fired fleet must find technologies which allow it to move into a more flexible cyclic load dispatch model. Today the installed coal fired utility fleet must be cost of generation competitive, fully emissions compliant, and responsive to the variability inherent in renewable energy generation sources. In the Phase I of the project, GE Steam Power, Inc. (GE) performed modeling of different operating scenarios for low load operation using an existing full plant dynamic model developed for a 660MW steam power plant. Sensors and analytic algorithms to enable a stable and steady coal supply for low load pulverizer operation were identified and tested at the Pulverizer Development Facility (PDF) at GE’s Clean Energy Center in Bloomfield, Connecticut. Sensors and analytic algorithms to enable stable combustion for low load operation were identified and tested at the 15 MWth Industrial Scale Burner facility (ISBF) at GE’s Clean Energy Center. A concept was developed to test the sensors and control algorithms, down selected after testing, at a full-scale coal fired power plant. A budget estimate was then developed, and the concept was implemented at an existing utility power plant. The specific objectives of the experimental work were to: • Identify and select sensors and analytic algorithms for monitoring coal pulverizer operation at lower loads to provide stable operation and appropriate coal fineness at lower coal throughput; Identify and select sensors and analytic algorithms for a Boiler Flame Stability Monitor to better balance air and fuel at each burner. This enables a reduction in a coal boiler’s safe low load power level while maintaining stable flame characteristics; Develop a concept in Phase I for low load operation of a full-scale power plant and develop a budget estimate for testing and execute the test plan at an existing plant in Phase II; Validate the capability of the extended low load boiler system to extend the minimum load operating point in a safe and reliable manner on an existing full-scale utility boiler. At the completion of this experimental study, GE has developed a set of sensors and analytic algorithms, down selected after testing, that have the potential to enable safe low load operation of a utility boiler. GE has also identified a host site for testing these identified sensors and analytic algorithms. GE has generated a full set of deliverables that provide sufficient information to proceed with the next step of testing at a host site. This includes a potential host site and budget estimate for concept testing at host site. In the Phase II of the project, a series of field tests were completed to validate the extended low load boiler operation, which consisted of detailed engineering, installation, commissioning, and testing the additional sensors and analytics for the coal-fired combustion system on an existing full-scale utility boiler. The optimization work has been supported by the host plant and endorsed by their engineering and operation staff.

01 COAL, LIGNITE, AND PEAT↗

Production of Fischer-Tropsch Synfuels at Nuclear Plants

A case study analysis was performed to evaluate nuclear-powered synthetic fuel production in the midwestern United States (U.S.). A Fischer-Tropsch (FT) fuel synthesis plant design was used as the basis for the analysis. The FT plant design was configured to produce a product slate consisting of diesel fuel, jet fuel, and motor gasoline blend stocks from carbon dioxide (CO 2 ) and hydrogen (H 2 ) feedstocks. The CO 2 feedstock for the FT plant was assumed to be sourced from biorefineries in the region around a Midwest light water reactor (LWR) nuclear power plant (NPP). The analysis specifies that power from the LWR is used to produce H 2 via high-temperature steam electrolysis and to operate the FT synfuel production plant. Capital costs were estimated for the FT plant while capital costs for the electrolysis plant were based on previous Idaho National Laboratory (INL) studies. In addition to labor and maintenance costs for the FT and electrolysis plants, operating costs also include the costs for CO 2 feedstock transport. An analysis was performed to determine the cost of transporting CO 2 from the distributed biorefinery sources to the centralized fuel synthesis plant as a function of the synfuel plant capacity and corresponding CO 2 demand. The primary revenue streams are associated with sales of the synthetic fuel products. The synthetic fuel products will likely follow the same market trends as the conventional fuel products. The synfuel price data was thus based on projections made by the U.S. Energy Information Administration (EIA) 2021 Annual Energy Outlook (AEO) for conventional fuel products minus federal and state taxes, as well as marketing and distribution costs. The economic analysis also considered cases that included and excluded revenues from the 2022 Inflation Reduction Act (IRA) clean hydrogen production tax credit (PTC) of $\$ $3.00/kg for the first ten years of operation. The economic analysis calculated the net present value (NPV) for cases involving steady-state synfuel production for comparison with the NPV for a business-as-usual case in which NPP continues to sell only electric power to the grid. A synfuel production “Reference Case” was considered in addition to sensitivity cases in which the plant capacity, electricity price, and synthetic fuel product prices were perturbed. The synfuel production Reference Case considered a scenario in which the electrolysis and synfuel plants utilized a combined electrical load of 1000 megawatt electrical (MWe) from the LWR with the balance of the LWR power output being sold to the electric grid. The economic analysis suggests that the synfuel production Reference Case evaluated in this analysis would lead to considerable economic potential for near-term deployment of a nuclear-based synfuel production plant. Specifically, the economic analysis suggests that the deployment of a 1000 megawatt (MW) nuclear-powered synfuel plant could result in a NPV increase of approximately $\$ $1.7 billion for a case with no clean synfuel price premium relative to conventional petroleum fuels when accounting for the additional revenues from the 2022 IRA clean hydrogen PTCs of $\$ $3/kg. Sensitivity analysis was performed to evaluate the effect of perturbation of selected model input parameters on the NPV for the synfuel production Reference Case. The sensitivity analysis indicates that the plant capacity has the largest impact on the differential NPV, with a smaller synfuel production capacity resulting in a decrease in revenue when a larger fraction of the power from the NPP is sold to the grid and a smaller fraction of the power is used to produce synthetic fuel products. The synfuel product pricing has the next largest impact on the differential NPV, with lower synfuel prices resulting in decreased NPV from decreased synfuel sales revenue while higher synfuel prices result in increased NPV from increased synfuel sales revenue. Electricity pricing has a smaller effect on the NPV than the fuel sales price since, in the Reference Case, most of the energy from the NPP is used for synfuel production and a smaller amount of the system revenues are associated with electrical power sales. However, the electricity price sensitivity does indicate that the Synfuel Integrated Energy System (IES) would have a greater NPV than the business-as-usual case (e.g., grid power sales only) when electricity market prices are low, suggesting that synfuel production could provide a strategy for decreasing the economic risks to NPPs posed by a loss of revenues attributed to falling electricity market prices.

10 SYNTHETIC FUELS↗

TPCPF: Three-Phase Continuation Power Flow Tool for Voltage Stability Assessment of Distribution Networks With Distributed Energy Resources

This article presents a three-phase unbalanced continuation power flow algorithm for voltage stability assessment of distribution systems with high penetration of distributed energy resources (DERs). Analyzing distribution system voltage stability with DER will allow high penetration of renewable energy necessary for the sustainability goals. The developed algorithm can analyze voltage stability for both the meshed and radial systems and the balanced and unbalanced three-phase distribution systems. The developed tool allows the voltage stability analysis to facilitate the planning, operation, control, and distribution system management. The impact of DER on the voltage stability of several test cases has been analyzed considering constant power (P Q) and regulated-voltage (P V ) modes of operation for DER units. Moreover, different voltage stability case studies are presented to demonstrate the impact of unbalance, load increment, and network topology on the maximum loading capacity. Finally, results using the IEEE 13-node feeder, the 18-bus balanced shipboard system, the 13-node CIGRE benchmark system, and the 136-bus redial distribution feeder demonstrate that the developed continuation power flow tool can efficiently perform voltage stability analysis for active distribution systems.

42 ENGINEERING↗

Report on High-Fidelity Dynamic Modeling of a Coal-Fired Steam Power Plant

As a result of the growth of renewables including solar and wind energy with fluctuating production, fossil fuel power plants are being required to cycle between high and low power production. This cycling is both at a greater frequency and over a wider range than in the past. In many cases, power plants are not designed for this type of cycling operation but can nonetheless endure these challenging operation requirements under the right conditions. In this project, optimal solution for enhanced flexible operations are being investigated using model based estimation and control techniques. To support the development of model-based estimator and model-based controls at GE Global Research, GE Steam Power configured a dynamic model using a reference steam plant design including the boiler, turbine, and water/steam conditioning systems as well as the controls needed for plant cycling with stability and reliability. The dynamic model was built using the APROS® software from VTT, and then calibrated to multiple load conditions from full load (100%TMCR) to partial loads (75%TMCR, 50%TMCR and 25%TMCR) based on internally developed steady state heat balance models at the unit level. These internal heat balance models are based on first principles and extensive engineering experiences from GE Steam Power as an OEM and a services provider. This topical report presents the structure of the unit level dynamic model, the tuning process, and representative simulation results from typical load cycling simulations using the dynamic model.

01 COAL, LIGNITE, AND PEAT↗

Application of Intelligent Load Control to Manage Building Loads to Support Rapid Growth of Distributed Renewable Generation

Electricity utilities are faced with the mounting challenge of providing a stable supply of power to meet the growing demand while also integrating rapid growth in distributed variable renewable generation. Traditional means of balancing short- and long-term supply and demand imbalance will be expensive. Alternative approaches of using flexible loads in buildings are needed to mitigate the imbalance at a lower cost. This paper shows how the intelligent load control (ILC) process can be used to manage loads in buildings by dynamically prioritizing loads for curtailment using both quantitative and qualitative criteria. The ILC process can be deployed on low-cost computing platforms without the need for any additional sensing. ILC was first validated in a simulation environment to provide two grid service use cases: (1) managing monthly peak electricity demand and (2) managing buildings’ electricity consumption during a capacity bidding event. After being successfully tested in a simulation environment, ILC was deployed on real buildings to manage electricity consumption to provide two different use cases under different outdoor operating conditions. Both the simulation tests and the real building experiments were deployed using VOLTTRON™, a distributed sensing and control platform. The results from the tests and experiments showed that ILC was able to manage the controllable loads (heat pumps) in the building to maintain the electricity consumption at the desired level without a significant impact on occupant comfort. Overall, the results demonstrate that the ILC allows coordination of the controllable loads and provides a more intelligent means of load management than the traditional duty-cycling approach.

Kim, Woohyun↗

Nontraditional Approaches To Enable High-Energy and Long-Life Lithium–Sulfur Batteries

In this study, lithium-sulfur (Li-S) batteries are promising for automotive applications due to their high theoretical energy density (2600 Wh/kg). In addition, the natural abundance of sulfur could mitigate the global raw material supply chain challenge of commercial lithium-ion batteries that use critical elements, such as nickel and cobalt. However, due to persistent polysulfide shuttling and uncontrolled lithium dendrite growth, Li-S batteries using nonencapsulated sulfur cathodes and conventional ether-based electrolytes suffer from rapid cell degradation upon cycling. Despite significant improvements in recent decades, there is still a big gap between lab research and commercialization of the technology. To date, the reported cell energy densities and cycling life of practical Li-S pouch cells remain largely unsatisfactory. Traditional approaches to improving Li-S performance are primarily focused on confining polysulfides using electronically conductive hosts. However, these micro- and mesoporous hosts suffer from limited pore volume to accommodate high sulfur loading and the associated volume change during cycling. Moreover, they fail to balance adsorption-conversion of polysulfides during charge-discharge, leading to the formation of massive dead sulfur. Such hosts are themselves electrochemically inactive, which decreases the practical energy density. In contrast, a series of nontraditional approaches, paired with advances in multiscale mechanistic understanding, have recently demonstrated exciting performance outcomes not only in conventional coin cells but also in practical pouch cells. In this Account, we first introduce our novel cathode design strategies to overcome polysulfide shuttling and sluggish redox kinetics in thick S cathodes via selenium-sulfur chemistry and cathode host engineering. Next, we gain a mechanistic understanding of Li-S batteries in various types of electrolytes via a series of spectroscopic, nuclear magnetic resonance, and electrochemical methods. Meanwhile, a novel cathode solid electrolyte interphase encapsulation strategy via nonviscous highly fluorinated ether-based electrolyte is introduced. The established selection rule by investigating how solvating power retards the shuttle effect and induces robust cathode/solid-electrolyte interphase formation is also included. We then discuss how the synergistic interactions between rational cathode structures and electrolytes can be exploited to tailor the reaction pathways and kinetics of S cathodes under high mass loading and lean electrolyte conditions. In addition, a novel interlayer design to simultaneously overcome degradation processes (polysulfide shuttling and lithium dendrite formation) and accelerate redox reaction kinetics is presented. Finally, this Account concludes with an overview of the challenges and strategies to develop Li-S pouch cells with high practical energy density, long cycle life, and fast-charging capability.

25 ENERGY STORAGE↗