Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Probing ultra-fast processes with high dynamic range at 4th-generation light sources: Arrival time and intensity binning at unprecedented repetition rates

Here, understanding dynamics on ultrafast timescales enables unique and new insights into important processes in the materials and life sciences. In this respect, the fundamental pump-probe approach based on ultra-short photon pulses aims at the creation of stroboscopic movies. Performing such experiments at one of the many recently established accelerator-based 4th-generation light sources such as free-electron lasers or superradiant THz sources allows an enormous widening of the accessible parameter space for the excitation and/or probing light pulses. Compared to table-top devices, critical issues of this type of experiment are fluctuations of the timing between the accelerator and external laser systems and intensity instabilities of the accelerator-based photon sources. Existing solutions have so far been only demonstrated at low repetition rates and/or achieved a limited dynamic range in comparison to table-top experiments, while the 4th generation of accelerator-based light sources is based on superconducting radio-frequency technology, which enables operation at MHz or even GHz repetition rates. In this article, we present the successful demonstration of ultra-fast accelerator-laser pump-probe experiments performed at an unprecedentedly high repetition rate in the few-hundred-kHz regime and with a currently achievable optimal time resolution of 13 fs (rms). Our scheme, based on the pulse-resolved detection of multiple beam parameters relevant for the experiment, allows us to achieve an excellent sensitivity in real-world ultra-fast experiments, as demonstrated for the example of THz-field-driven coherent spin precession.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

EUV light source with high brightness at 13.5 nm

The results of the studies on the development of a highbrightness radiation source in the extreme ultraviolet (EUV) range are presented. The source is intended for using in projection EUV lithography, EUV mask inspection, for the EUV metrology, etc. Novel approaches to creating a light source on the basis of Z-pinch in xenon allowed the maximal brightness [130 W(mm{sup 2} sr){sup -1}] to be achieved in the vicinity of plasma for this type of radiation sources within the 2% spectral band centred at the wavelength of 13.5 nm that corresponds to the maximal reflection of multilayer Mo/Si mirrors. In this spectral band the radiation power achieves 190 W in the solid angle of 2π at a pulse repetition rate of 1.9 kHz and an electric power of 20 kW, injected into the discharge. (laser applications and other topics in quantum electronics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sixth user workshop on high-power lasers at the linac coherent light source

The international user workshop on High-Power Lasers at the Linac Coherent Light Source (LCLS) was held at SLAC National Accelerator Laboratory (SLAC) in Menlo Park, CA on September 25-26, 2018. More than 100 scientists attended the workshop, which focused on recent experiments and developments at the LCLS – Matter in Extreme Conditions (MEC) end station and, more generally, the scientific frontiers that can be explored using the combination of highpower lasers and the LCLS hard X-ray free electron laser (XFEL). This workshop was the sixth annual meeting in a series that has promoted information exchange between users and has provided recommendations on capability upgrades at LCLS-MEC.

47 OTHER INSTRUMENTATION↗

All-diamond optical assemblies for a beam-multiplexing X-ray monochromator at the Linac Coherent Light Source

A double-crystal diamond (111) monochromator recently implemented at the Linac Coherent Light Source (LCLS) enables splitting of the primary X-ray beam into a pink (transmitted) and a monochromatic (reflected) branch. The first monochromator crystal, with a thickness of ~100 µm, provides sufficient X-ray transmittance to enable simultaneous operation of two beamlines. This article reports the design, fabrication and X-ray characterization of the first and second (300 µm-thick) crystals utilized in the monochromator and the optical assemblies holding these crystals. Each crystal plate has a region of about 5 × 2 mm with low defect concentration, sufficient for use in X-ray optics at the LCLS. The optical assemblies holding the crystals were designed to provide mounting on a rigid substrate and to minimize mounting-induced crystal strain. The induced strain was evaluated using double-crystal X-ray topography and was found to be small over the 5 × 2 mm working regions of the crystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Terahertz Light Source and User Area at FACET

FACET at SLAC provides high charge, high peak current, low emittance electron beam that is bunched at THz wavelength scale during its normal operation. A THz light source based coherent transition radiation (CTR) from this beam would potentially be the brightest short-pulse THz source ever constructed. Efforts have been put into building this photon source together with a user area, to provide a platform to utilize this unique THz radiation for novel nonlinear and ultrafast phenomena researches and experiments. Being a long-time underutilized portion of the electromagnetic spectrum, terahertz (100 GHz {approx} 10 THz) spectral range is experiencing a renaissance in recent years, with broad interests from chemical and biological imaging, material science, telecommunication, semiconductor and superconductor research, etc. Nevertheless, the paucity of THz sources especially strong THz radiation hinders both its commercial applications and nonlinear processes research. FACET - Facilities for Accelerator science and Experimental Test beams at SLAC - provides 23 GeV electron beam with peak currents of {approx} 20 kA that can be focused down to 100 {mu}m{sup 2} transversely. Such an intense electron beam, when compressed to sub-picosecond longitudinal bunch length, coherently radiates high intensity EM fields well within THz frequency range that are orders of magnitude stronger than those available from laboratory tabletop THz sources, which will enable a wide variety of THz related research opportunities. Together with a description of the FACET beamline and electron beam parameters, this paper will report FACET THz radiation generation via coherent transition radiation and calculated photon yield and power spectrum. A user table is being set up along the THz radiation extraction sites, and equipped with various signal diagnostics including THz power detector, Michelson interferometer, sample stages, and sets of motorized optical components. This setup will also be presented. Potential THz research areas including studies of magnetism, ferroelectric switching dynamics, semiconductor devices and chemical reaction controls have already been proposed for the FACET THz area.

43 PARTICLE ACCELERATORS↗

Thermionic microwave gun for terahertz and synchrotron light sources

Conventional thermionic microwave and radiofrequency (RF) guns can offer high average beam current, which is important for synchrotron light and terahertz (THz) radiation source facilities, as well as for industrial applications. For example, the Advanced Photon Source at Argonne National Laboratory is a national synchrotron radiation light source research facility that utilizes thermionic RF guns. Yet, these existing thermionic guns are bulky, difficult to handle and install, easily detuned, very sensitive to thermal expansion, and are due for a major upgrade and replacement. Here, we present the design of a new, more stable and reliable gun with optimized electromagnetic performance, improved thermal engineering and a more robust cathode mounting technique, which is a critical step to improve the performance of existing and future light sources, industrial accelerators, and electron beam-driven terahertz sources. We will also present a fabricated gun prototype and show results of high-power and beam tests.

47 OTHER INSTRUMENTATION↗

Variable Gap Undulator for 1.5-48 Kev Free Electron Laser at Linac Coherent Light Source

We study the feasibility of generating femtosecond duration Free-Electron Laser with a variable photon energy from 1.5 to 48 keV, using an electron bunch with the same characteristics of the LINAC Coherent Light Source (LCLS) bunch, and a planar undulator with additional focusing. We assume that the electron bunch energy can be changed, and the undulator has a variable gap, allowing a variable undulator parameter. It is assumed to be operated in an ultra-low charge and ultra-short pulse regime. We study the feasibility of a tunable, short pulse, X-ray FEL with photon energy from 1.5 to 48 keV, using an electron beam like the one in the LCLS and a 2:5 cm period, variable gap, planar undulator. The beam energy changes from 4.6 to 13.8 GeV, the electorn charge is kept at 10 pC, and the undulator parameter varies from 1 to 3. The undulator length needed to saturate the 48 keV FEL is about 55 m, with a peak power around 5 GW. At longer wavelength the saturation length is as short as 15 m, and the peak power around 20 GW. The results from the analytical models and the GENESIS simulations show that the system is feasible. The large wavelength range, full tunability and short, few femtosecond pulses, together with the large peak power, would provide a powerful research tool.

43 PARTICLE ACCELERATORS↗

Hard x-ray nanoprobe facility at the National Synchroton Light Source II

The Hard X-ray Nanoprobe (HXN) Beamline [1] of the National Synchrotron Light Source II (NSLS-II) is now available for general user experiments. This beamline was developed with the world’s most ambitious resolution goal for hard x-rays. Its initial performance target is to enable x-ray imaging experiments at a resolution of 10 nm, with an ultimate goal of reaching ~1 nm.

36 MATERIALS SCIENCE↗

Calibration of space instruments at the Metrology Light Source

PTB has more than 20 years of experience in the calibration of space-based instruments using synchrotron radiation to cover the UV, VUV and X-ray spectral range. New instrumentation at the electron storage ring Metrology Light Source (MLS) opens up extended calibration possibilities within this framework. In particular, the set-up of a large vacuum vessel that can accommodate entire space instruments opens up new prospects. Moreover, a new facility for the calibration of radiation transfer source standards with a considerably extended spectral range has been put into operation. Besides, characterization and calibration of single components like e.g. mirrors, filters, gratings, and detectors is continued.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic Monitoring of Grating Angle at the National Synchrotron Light Source

We present a dynamic monitoring method and monitoring system of grating angle, referred to as the Precise Angle Monitor (PAM), at U4B, a soft x-ray spherical grating monochromator (SGM) beam line at the National Synchrotron Light Source (NSLS). In an SGM, a photon energy scan is accomplished by rotating the grating angle precisely. After several decades of service, the monochromator at U4B developed instabilities that severely impacted the experimental program. Over several hours, either the spectral shape experienced distortions or the spectral peak shifted. In order to directly monitor the grating motion during scans, the optical head of a portable long trace profiler (PTLTP) was installed on U4B as the PAM. We find that the grating rotational motion is not ideal: (1) the scan steps are not smooth and there are high-frequency step angle errors; (2) there is also a low-frequency angle error; and (3) an unstable thermal expansion produces extra rotational error. Measurements of dynamic monitoring are presented, including grating rotation repeatability and thermal instability. The results illustrate the utility of dynamic monitoring of monochromator motion during actual operation.

43 PARTICLE ACCELERATORS↗

Injector Beam Dynamics for a High-Repetition Rate 4th-Generation Light Source

We report on the beam dynamics studies and optimization methods for a high repetition rate (1 MHz) photoinjector based on a VHF normal conducting electron source. The simultaneous goals of beamcompression and reservation of 6-dimensional beam brightness have to be achieved in the injector, in order to accommodate a linac driven FEL light source. For this, a parallel, multiobjective optimization algorithm is used. We discuss the relative merits of different injector design points, as well as the constraints imposed on the beam dynamics by technical considerations such as the high repetition rate.

43 PARTICLE ACCELERATORS↗

Array-based goniospectroradiometer for measurement of spectral radiant intensity and spectral total flux of light sources

We present a description of a new goniospectroradiometric measurement system developed at the National Physical Laboratory (NPL). The instrument incorporates a modified array spectrometer and a series of rotary stages to allow measurement of the spectral radiant intensity distribution of a variety of different types of light source from 350 to 830 nm. Associated source properties such as chromaticity and correlated color temperature distributions and total spectral flux are then calculated from the radiant intensity data. A preliminary comparison with NPL's integrating sphere-based luminous flux scale shows agreement to within 0.4%, well within the combined measurement uncertainty. Measurements of the luminous intensity and color temperature distributions and the spectral total flux of a tungsten filament flux standard, a white LED cluster and a compact fluorescent source made using the goniospectroradiometer, are also presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma physics and radiation hydrodynamics in developing an extreme ultraviolet light source for lithography

Extreme ultraviolet (EUV) radiation from laser-produced plasma (LPP) has been thoroughly studied for application in mass production of next-generation semiconductor devices. One critical issue for the realization of an LPP-EUV light source for lithography is the conversion efficiency (CE) from incident laser power to EUV radiation of 13.5-nm wavelength (within 2% bandwidth). Another issue is solving the problem of damage caused when debris reaches an EUV collecting mirror. Here, we present an improved power balance model, which can be used for the optimization of laser and target conditions to obtain high CE. An integrated numerical simulation code has been developed for the target design. The code agrees well with experimental results not only for CE but also for detailed EUV spectral structure. We propose a two-pulse irradiation scheme for high CE, and reduced ion debris using a carbon dioxide laser and a droplet or a punch-out target. Using our benchmarked numerical simulation code, we find a possibility to obtain CE up to 6-7%, which is more than twice that achieved to date. We discuss the reduction of ion energy within the two-pulse irradiation scheme. The mitigation of energetic ions by a magnetic field is also discussed, and we conclude that no serious instability occurs due to large ion gyroradius.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of out-of-band radiation and plasma parameters in laser-produced Sn plasmas for extreme ultraviolet lithography light sources

Out-of-band (OOB) radiation, in contrast to the in-band radiation at 13.5 nm in a 2% bandwidth, emitted from dense tin plasmas generated by a laser was investigated for application as an extreme ultraviolet lithography light source. It was found that the continuum spectrum, which overwhelms the atomic and ionic line emissions, is responsible for the intense OOB radiation. The spectral distribution of the continuum emission matches that of blackbody radiation with a temperature of about 10 eV. The OOB radiation can be considerably suppressed by employing a minimum-mass target and short-pulse laser irradiation. Spectroscopic observations were made to examine the spatiotemporal behavior of the plasma immediately after laser irradiation. Prominent line broadening due to the Stark effect in the high-density plasma was observed, from which the variation of the electron density was deduced. The electron density and temperature on the target surface were 10{sup 17}-10{sup 18} cm{sup -3} and a few eV's, respectively, in the first 200 ns after laser illumination. In addition, the expansion velocities of neutral and singly ionized tin atoms were deduced from time-of-flight transients in the spectral emission.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bright, Coherent, Ultrafast Soft X-Ray Harmonics Spanning the Water Window from a Tabletop Light Source

We demonstrate fully phase-matched high harmonic emission spanning the water window spectral region important for nano- and bioimaging and a breadth of materials and molecular dynamics studies. We also generate the broadest bright coherent bandwidth ({approx_equal}300 eV) to date from any light source, small or large, that is consistent with a single subfemtosecond burst. The harmonic photon flux at 0.5 keV is 10{sup 3} higher than demonstrated previously. This work extends bright, spatially coherent, attosecond pulses into the soft x-ray region for the first time.

07 ISOTOPE AND RADIATION SOURCES↗

6 nm super-resolution optical transmission and scattering spectroscopic imaging of carbon nanotubes using a nanometer-scale white light source

Abstract Optical transmission and scattering spectroscopic microscopy at the visible and adjacent wavelengths denote one of the most informative and inclusive characterization methods in material research. Unfortunately, restricted by the diffraction limit of light, it cannot resolve the nanoscale variation in light absorption and scattering, diagnostics of the local inhomogeneity in material structure and properties. Moreover, a large quantity of nanomaterials has anisotropic optical properties that are appealing yet hard to characterize through conventional optical methods. There is an increasing demand to extend the optical hyperspectral imaging into the nanometer length scale. In this work, we report a super-resolution hyperspectral imaging technique that uses a nanoscale white light source generated by superfocusing the light from a tungsten-halogen lamp to simultaneously obtain optical transmission and scattering spectroscopic images. A 6-nm spatial resolution in the visible to near-infrared wavelength regime (415–980 nm) is demonstrated on an individual single-walled carbon nanotube (SW-CNT). Both the longitudinal and transverse optical electronic transitions are measured, and the SW-CNT chiral indices can be identified. The band structure modulation in a SW-CNT through strain engineering is mapped.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗