Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lasers sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Diffractive Multiplexing for High-Throughput Roll-to-Roll Laser Patterning of Flexible Organic Photovoltaic Modules (Final Report)

The purpose of this project is to demonstrate a cost-effective, high-throughput roll-to-roll (R2R) process for patterning of flexible, semitransparent organic photovoltaic (OPV) modules by developing diffractive optics-based laser multiplexing (DOL Multiplexing). DOL Multiplexing allows a single, high-powered laser source to perform parallel scribing across the R2R web width in a manner compatible with high process speeds. Such a process could have enormous benefits in terms of increased process speeds and reduced costs, both up-front capital costs, and long-term operational costs, over galvanometer-based step and scan methods or many-laser systems.

14 SOLAR ENERGY↗

Photo-exfoliation of MoS 2 quantum dots from nanosheets: an in-situ transmission electron microscopy study

Fabrication of transition metal dichalcogenide (TMD) quantum dots (QDs) is complex and requires submerging of powders in binary solvents and the constant tuning of wavelength and pulsed frequency of light to achieve a desired reaction. Here,iInstead of liquid state photoexfoliation, we utilize infrared laser irradiation of free-standing MoS 2 flakes in transmission electron microscope (TEM) to achieve solid-state multi-level photoexfoliation of QDs. By investigating the steps involved in photochemical reaction between the surface of MoS 2 and the laser beam, we gain insight into each step of the photoexfoliation mechanism and observe high yield production of QDs, led by an inhomogeneous crystalline size distribution. Additionally, by using a laser with a lower energy than the indirect optical transition of bulk MoS 2 , we conclude that the underlying phenomena behind the photoexfoliation is from multi-photon absorption achieved at high optical outputs from the laser source. These findings provide an environmentally friendly synthesis method to fabricate QDs for potential applications in biomedicine, optoelectronics, and fluorescence sensing.

36 MATERIALS SCIENCE↗

Temporal evolution of the light emitted by a thin, laser-ionized plasma source

We present an experimental and simulation-based investigation of the temporal evolution of light emission from a thin, laser-ionized helium plasma source. We demonstrate an analytic model to calculate the approximate scaling of the time-integrated, on-axis light emission with the initial plasma density and temperature, supported by the experiment, which enhances the understanding of plasma light measurement for plasma wakefield accelerator (PWFA) plasma sources. Our model simulates the plasma density and temperature using a split-step Fourier code and a particle-in-cell code. A fluid simulation is then used to model the plasma and neutral density, and the electron temperature as a function of time and position. We then show the numerical results of the space-and-time-resolved light emission and that collisional excitation is the dominant source of light emission. We validate our model by measuring the light emitted by a laser-ionized plasma using a novel statistical method capable of resolving the nanosecond-scale temporal dynamics of the plasma light using a cost-effective camera with microsecond-scale timing jitter. This method is ideal for deployment in the high radiation environment of a particle accelerator that precludes the use of expensive nanosecond-gated cameras. Our results show that our models can effectively simulate the dynamics of a thin, laser-ionized plasma source. In addition, this work provides a detailed understanding of the plasma light measurement, which is one of the few diagnostic signals available for the direct measurement of PWFA plasma sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced propulsion concepts study: Comparative study of solar electric propulsion and laser electric propulsion

Solar electric propulsion (SEP) and laser electric propulsion (LEP) was compared. The LEP system configuration consists of an 80 kW visible laser source on earth, transmitting via an 8 m diameter adaptively controlled phased array through the atmosphere to a 4 m diameter synchronous relay mirror that tracks the LEP spacecraft. The only significant change in the SEP spacecraft for an LEP mission is the replacement of the two 3.7 m by 33.5 m solar cell arrays with a single 8 m diameter laser photovoltaic array. The solar cell array weight is decreased from 320 kg to 120 kg for an increase in payload of 200 kg and a decrease in specific mass of the power system from 20.5 kg/kW to 7.8 kg/kW.

Forward, R. L.↗

Highly Responsive Near-Infrared Photodetector Based on Contactless PdSe 2 Integration with a Few-Layered MoSe 2 Field-Effect Transistor

Two-dimensional (2D) semiconductors with narrow bandgaps are promising candidates for near- and far-infrared (IR) photodetection, particularly in the telecommunication spectral window. However, current low-bandgap IR photodetectors face significant challenges due to their high dark current, increased carrier recombination, and thermally generated noise. Here, in this work, a hybrid phototransistor is demonstrated by integrating direct, contact-free palladium diselenide (PdSe 2 ) as a highly responsive IR detection layer with a non-IR-absorbing molybdenum diselenide (MoSe 2 ) field-effect transistor (FET), using a near-IR source at a wavelength of λ = 1650 nm. Exfoliated PdSe 2 flakes integrated into a back-gated FET architecture exhibit ambipolar transport behavior, with extracted hole and electron mobilities of 24.8 cm 2 V –1 s –1 and 58.4 cm 2 V –1 s –1 , respectively. The devices show a clear photocurrent generation under the illumination of a λ = 1650 nm laser source, achieving a notable responsivity of ∼300 mA W -1 at an applied gate voltage of 15 V, which highlights the suitability of PdSe 2 as a narrow-bandgap material for photodetection. Photoresponsivity saturates and does not have any effect above an applied gate voltage of 15 V. To further tune the photoresponsivity performance continuously with the applied gate voltage, we construct a van der Waals heterostructure phototransistor, where few layers of PdSe 2 are directly transferred onto the 2D channel region of a MoSe 2 FET, while avoiding any contact with the metal electrodes. In this heterostructure, PdSe 2 works as the primary active IR-absorbing layer, while MoSe 2 provides high-performance FET characteristics. This spatial separation of absorption and transport facilitates efficient interlayer charge transfer and charge separation, resulting in high responsivities of up to 972 mA W –1 at near-IR wavelengths and a low power density of 1.5 mW/mm 2 . The responsivity of our photodetector is comparable to that of some state-of-the-art commercially available NIR photodetectors, highlighting the potential of PdSe 2 -based heterostructures as scalable, CMOS-compatible platforms for high-performance near-IR detection.

Infrared (IR) photodetectors↗

Exploring cesium properties internal to the LANSCE H - ion source using resonant absorption spectroscopy

The Los Alamos Neutron Science Center (LANSCE) H - ion source has provided stable output for decades of LANL mission needs, but its maximum beam output has remained the same at ~15 mA. A roadblock to improving beam output has been a lack of thorough understanding of the internal mechanisms of LANSCE H - ion source. The LANSCE H - Ion Source Laser Diagnostic Stand (HLDS) was recently built and commissioned to explore these internal mechanisms using laser absorption techniques, to measure and diagnose dynamic H - and cesium densities. The cesium density probe is based on resonant absorption of a continuous wave diode laser tuned though the D 2 line of cesium (~852 nm). The diagnostic capabilities of HLDS will be reviewed, and measurements using the cesium laser diagnostic will be presented.

43 PARTICLE ACCELERATORS↗

Ultrasensitive detection of atmospheric trace gases using frequency modulation spectroscopy

Frequency modulation (FM) spectroscopy is a new technique that promises to significantly extend the state-of-the-art in point detection of atmospheric trace gases. FM spectroscopy is essentially a balanced bridge optical heterodyne approach in which a small optical absorption or dispersion from an atomic or molecular species of interest generates an easily detected radio frequency (RF) signal. This signal can be monitored using standard RF signal processing techniques and is, in principle, limited only by the shot noise generated in the photodetector by the laser source employed. The use of very high modulation frequencies which exceed the spectral width of the probed absorption line distinguishes this technique from the well-known derivative spectroscopy which makes use of low (kHz) modulation frequencies. FM spectroscopy was recently extended to the 10 micron infrared (IR) spectral region where numerous polyatomic molecules exhibit characteristic vibrational-rotational bands. In conjunction with tunable semiconductor diode lasers, the quantum-noise-limited sensitivity of the technique should allow for the detection of absorptions as small as .00000001 in the IR spectral region. This sensitivity would allow for the detection of H2O2 at concentrations as low as 1 pptv with an integration time of 10 seconds.

Cooper, David E.↗

Technology Advancement for Active Remote Sensing of Carbon Dioxide from Space Using the ASCENDS CarbonHawk Experiment Simulator: First Results

The ASCENDS CarbonHawk Experiment Simulator (ACES) is a newly developed lidar developed at NASA Langley Research Center and funded by NASA's Earth Science Technology Office (ESTO) Instrument Incubator Program (IIP) that seeks to advance technologies critical to measuring atmospheric column carbon dioxide (CO2) mixing ratios in support of the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) mission. The technology advancements targeted include: (1) increasing the power-aperture product to approach ASCENDS mission requirements by implementing multi-aperture telescopes and multiple co-aligned laser transmitters; (2) incorporating high-efficiency, high-power Erbium-Doped Fiber Amplifiers (EDFAs); (3) developing and incorporating a high-bandwidth, low-noise HgCdTe detector and transimpedence amplifier (TIA) subsystem capable of long-duration autonomous operation on Global Hawk aircraft, and (4) advancing algorithms for cloud and aerosol discrimination. The ACES instrument architecture is being developed for operation on high-altitude aircraft and will be directly scalable to meet the ASCENDS mission requirements. These technologies are critical towards developing not only spaceborne instruments but also their airborne simulators, with lower platform requirements for size, mass, and power, and with improved instrument performance for the ASCENDS mission. ACES transmits five laser beams: three from commercial EDFAs operating near 1.57 microns, and two from the Exelis oxygen (O2) Raman fiber laser amplifier system operating near 1.26 microns. The three EDFAs are capable of transmitting up to 10 watts average optical output power each and are seeded by compact, low noise, stable, narrow-linewidth laser sources stabilized with respect to a CO2 absorption line using a multi-pass gas absorption cell. The Integrated-Path Differential Absorption (IPDA) lidar approach is used at both wavelengths to independently measure the CO2 and O2 column number densities and retrieve the average column CO2 mixing ratio. The ACES receiver uses three fiber-coupled 17.8-cm diameter athermal telescopes. The transmitter assembly consists of five fiber-coupled laser collimators and an associated Risley prism pair for each laser to co-align the outgoing laser beams and to align them with the telescope field of view. The backscattered return signals collected by the three telescopes are combined in a fiber bundle and sent to a single low noise detector. The detector/TIA development has improved the existing detector subsystem by increasing its bandwidth to 4.7 MHz from 500 kHz and increasing the duration of autonomous, service-free operation periods from 4 hours to >24 hours. The new detector subsystem enables the utilization of higher laser modulation rates, which provides greater flexibility for implementing advanced thin-cloud discrimination algorithms as well as improving range-determination resolution and error reduction. The cloud/aerosol discrimination algorithm development by Langley and Exelis features a new suite of algorithms for the minimization/elimination of bias errors in the return signal induced by the presence of intervening thin clouds. Multiple laser modulation schemes are being tested in an effort to significantly mitigate the effects of thin clouds on the retrieved CO2 column amounts. Full instrument development concluded in the spring of 2014. After ground range tests of the instrument, ACES successfully completed six test flights on the Langley Hu-25 aircraft in July, 2014, and recorded data at multiple altitudes over land and ocean surfaces with and without intervening clouds. Preliminary results from these test flights will be presented in this paper.

Obland, Michael D.↗

Portable high-resolution laser monochromator-interferometer with multichannel electronic readout

A high-resolution 0.4-m monochromator is described for use in wavelength diagnosis of tunable pulsed and CW laser sources in the 3000-10,000-A region. The f/20 design uses an echelle grating in an over-and-under Ebert configuration with a scanned photodiode array to provide a real-time multichannel display of spectral output. Absolute wavelength may be determined to 0.1 A with the monochromator, and a Fabry-Perot interferometer attachment extends linewidth measurement capability to 0.01 A or better. Spectra are displayed on a storage oscilloscope, and calculation of laser parameters is explained. The instrument measures 70 cm long x 15 cm wide x 20 cm high.

Morris, M. B.↗

X-ray free-electron laser based dark-field X-ray microscopy: a simulation-based study

Dark-field X-ray microscopy (DFXM) is a nondestructive full-field imaging technique providing three-dimensional mapping of microstructure and local strain fields in deeply embedded crystalline elements. This is achieved by placing an objective lens in the diffracted beam, giving a magnified projection image. So far, the method has been applied with a time resolution of milliseconds to hours. In this work, the feasibility of DFXM at the picosecond time scale using an X-ray free-electron laser source and a pump–probe scheme is considered. Thermomechanical strain-wave simulations are combined with geometrical optics and wavefront propagation optics to simulate DFXM images of phonon dynamics in a diamond single crystal. Using the specifications of the XCS instrument at the Linac Coherent Light Source as an example results in simulated DFXM images clearly showing the propagation of a strain wave.

47 OTHER INSTRUMENTATION↗

Resonance ionization mass spectrometry for isotopic abundance measurements

Resonance ionization mass spectrometry (RIMS) is a relatively new laser-based technique for the determination of isotopic abundances. The resonance ionization process depends upon the stepwise absorption of photons from the laser, promoting atoms of the element of interest through progressively higher electronic states until an ion is formed. Sensitivity arises from the efficiency of the resonant absorption process when coupled with the power available from commercial laser sources. Selectivity derives naturally from the distinct electronic structure of different elements. This isobaric discrimination has provided the major impetus for development of the technique. Resonance ionization mass spectrometry was used for analysis of the isotopic abundances of the rare earth lutetium. Isobaric interferences from ytterbium severely effect the ability to measure small amounts of the neutron-deficient Lu isotopes by conventional mass spectrometric techniques. Resonance ionization for lutetium is performed using a continuous-wave laser operating at 452 nm, through a sequential two-photon process, with one photon exciting the intermediate resonance and the second photon causing ionization. Ion yields for microgram-sized quantities of lutetium lie between 10(6) and 10(7) ions per second, at overall ionization efficiencies approaching 10(-4). Discrimination factors against ytterbium greater than 10(6) have been measured. Resonance ionization for technetium is also being explored, again in response to an isobaric interference, molybdenum. Because of the relatively high ionization potential for Tc, three-photon, two-color RIMS processes are being developed.

Miller, C. M.↗

A comparison of optical technologies for a high data rate Mars link

Several optical systems, based on Nd:YAG, GaAs, and CO2 laser sources and employing both direct and heterodyne detection, are analyzed in order to assess their feasibility in providing high data rate (10-1000 Mbps) Mars-to-earth communications. The rms pointing/tracking accuracy is shown to be a critical parameter in defining the Mars-earth optical link. Data obtained reveal that unless, extremely small rms pointing and tracking errors can be achieved (sigma less than .2 microrad), the most promising optical implementation appears to be the Nd:YAG laser using direct detection and high order PPM modulation.

Spence, Rodney L.↗

Measurements of KrF laser-induced O2 fluorescence in high-temperature atmospheric air

Conditions for obtaining laser-induced O2 fluorescence using a tunable KrF laser has been determined theoretically and experimentally. With this laser source, O2 rotational temperature measurement is possible even in the absence of vibrational equilibrium. Temperature measurement using a two-line excitation scheme has been demonstrated in a high-temperature atmospheric-air furnace. A measurement uncertainty of 10.7 percent for the temperature range 1325-1725 K was realized. At atmospheric pressure, O2 LIF measurements are possible for air temperatures above 1250 K. Interference from OH fluorescence in reacting flows can be avoided by the proper selection of O2 transitions. Depletion of the ground state population by the incident laser is negligible for intensities below 7.5 x 10 to the 6th W/sq cm/per cm.

Grinstead, Jay H.↗

Cloud Thickness from Offbeam Returns - Thor Lidar

Physical thickness of a cloud layer, and sometimes multiple cloud layers, can be estimated from the time delay of off-beam returns from a pulsed laser source illuminating one side of the cloud layer. In particular, the time delay of light returning from the outer diffuse halo of light surrounding the beam entry point, relative to the time delay at beam center, determines the cloud physical thickness. The delay combined with the pulse stretch gives the optical thickness. The halo method works best for thick cloud layers, typically optical thickness exceeding 2, and thus compliments conventional lidar which cannot penetrate thick clouds. Cloud layer top and base have been measured independently over the ARM/SGP site using conventional laser ranging (lidar) and the top minus base thickness are compared with a cloud top halo estimate obtained from the NASA/Goddard THOR System (THOR = THickness from Offbeam Returns). THOR flies on the NASA P3, and measures the halo timings from several km above cloud top, at the same time providing conventional lidar cloud top height. The ARM/SGP micropulse lidar provides cloud base height for validation.

Cahalan, R.↗

High Intensity Laser Power Beaming Architecture for Space and Terrestrial Missions

High Intensity Laser Power Beaming (HILPB) has been developed as a technique to achieve Wireless Power Transmission (WPT) for both space and terrestrial applications. In this paper, the system architecture and hardware results for a terrestrial application of HILPB are presented. These results demonstrate continuous conversion of high intensity optical energy at near-IR wavelengths directly to electrical energy at output power levels as high as 6.24 W from the single cell 0.8 cm2 aperture receiver. These results are scalable, and may be realized by implementing receiver arraying and utilizing higher power source lasers. This type of system would enable long range optical refueling of electric platforms, such as MUAV s, airships, robotic exploration missions and provide power to spacecraft platforms which may utilize it to drive electric means of propulsion.

Nayfeh, Taysir↗

Fiber-Optic Silicon Fabry-Perot Interferometric Bolometer: The Influence of Mechanical Vibration and Magnetic Field

Plasma radiation plays an important role in the operation and control of magnetic confinement fusion and is typically measured by bolometers. Here, we study the influence of mechanical vibration and magnetic field, which are typically present in magnetic confinement fusion devices, on the performance of a fiber-optic bolometer (FOB) based on silicon Fabry-Perot interferometer (FPI) demodulated by a scanning diode laser. It is found that both the vibration and magnetic field could cause large noise due to the birefringence of the silicon FPI. To mitigate the birefringence effects, we demonstrated two effective methods: polarization maintaining FOB and polarization scrambling. We show that two methods can be effective in mitigating the effect caused by the sensor birefringence: (1) replacing the regular single-mode fiber in the FOB system with polarization-maintaining fiber and (2) using a polarization scrambler after the laser source. For both methods, no significant increase in the noise was observed in the vibration and magnetic field tests. Finally, our research highlights the importance of the polarization management for the FOB systems toward their practical applications in magnetic-confinement fusion systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Arrays of glass wedges for multi-dimensional optical diagnostics

There is a common need in the advancement of optical diagnostic techniques to increase the dimensionality of measurements. For example, point measurements could be improved to multi-point, line, planar, volumetric, or time-resolved volumetric measurements. In this work, a unique optical element is presented to enable multi-dimensional measurements, namely, an array of glass wedges. A light source is passed through the wedges, and different portions of the illumination are refracted by different amounts depending on the glass wedge angle. Subsequent optics can be used to focus the light to multiple points, lines, or planes. Basic characterization of a glass wedge array is presented. Additional wedge-array configurations are discussed, including the use of a periodic intensity mask for multi-planar measurements via structured illumination. The utility of this optical element is briefly demonstrated in (a) multi-planar flame particulate measurements, (b) multi-point femtosecond-laser electronic excitation tagging for flow velocimetry, and (c) multi-line nitric oxide molecular tagging velocimetry in a hypersonic shock-tunnel. One significant advantage of this optical component is its compatibility with high-energy laser sources, which may be a limiting factor with other beam-splitting or beam-forming elements such as some diffractive optics. Additionally, an array of glass wedges is simple and easily customizable compared to other methods for forming multiple closely spaced illumination patterns. In conclusion, suggestions for further development and applications are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Solid state laser systems for space application

Since the last report several things have happened to effect the research effort. In laser metrology, measurements using Michelson type interferometers with an FM modulated diode laser source have been performed. The discrete Fourier transform technique has been implemented. Problems associated with this technique as well as the overall FM scheme were identified. The accuracy of the technique is not at the level we would expect at this point. We are now investigating the effect of various types of noise on the accuracy as well as making changes to the system. One problem can be addressed by modifying the original optical layout. Our research effort was also expanded to include the assembly and testing of a diode pumped\Nd:YAG laser pumped\Ti sapphire laser for possible use in sounding rocket applications. At this stage, the diode pumped Nd:YAG laser has been assembled and made operational.

Kay, Richard B.↗