Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “landmark”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Clinical Evaluation of Positioning Verification Using Digital Tomosynthesis and Bony Anatomy and Soft Tissues for Prostate Image-Guided Radiotherapy

Purpose: To evaluate on-board digital tomosynthesis (DTS) for patient positioning vs. two-dimensional (2D) radiography and three-dimensional cone beam (CBCT). Methods and Materials: A total of 92 image sessions from 9 prostate cancer patients were analyzed. An on-board image set was registered to a corresponding reference image set. Four pairs of image sets were used: digitally reconstructed radiographs vs. on-board orthogonal paired radiographs for the 2D method, coronal-reference DTS vs. on-board coronal DTS for the coronal-DTS method, sagittal-reference DTS vs. on-board sagittal DTS for the sagittal-DTS method, and planning CT vs. CBCT for the CBCT method. The registration results were compared. Results: The systematic errors in all methods were <1 mm/1{sup o}. When registering the bony anatomy, the mean vector difference was 0.21 {+-} 0.11 cm between 2D and CBCT, 0.11 {+-} 0.08 cm between CBCT and coronal DTS, and 0.14 {+-} 0.07 cm between CBCT and sagittal DTS. The correlation between CBCT to DTS was stronger (coefficient = 0.92-0.95) than the correlation between 2D and CBCT or DTS (coefficient = 0.81-0.83). When registering the soft tissue, the mean vector difference was 0.18 {+-} 0.11 cm between CBCT and coronal DTS and 0.29 {+-} 0.17 cm between CBCT and sagittal DTS. The correlation coefficient of CBCT to sagittal DTS and to coronal DTS was 0.84 and 0.92, respectively. Conclusion: DTS could provide equivalent results to CBCT when the bony anatomy is used as landmarks for prostate image-guided radiotherapy. For soft tissue-based positioning verification, coronal DTS produced equivalent results to CBCT, but sagittal DTS alone was insufficient. DTS could allow for comparable soft tissue-based target localization with faster scanning time and a lower imaging dose compared with CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pelvic Lymph Node Topography for Radiotherapy Treatment Planning From Ferumoxtran-10 Contrast-Enhanced Magnetic Resonance Imaging

Purpose: To define a population-based pelvic lymph node clinical target volume (CTV) for radiotherapy treatment planning using magnetic resonance (MR) imaging and the ultrasmall superparamagnetic iron oxide lymph node contrast agent ferumoxtran-10. Methods and Materials: A total of 55 eligible patients with endometrial, cervical, prostate, or bladder cancer underwent MR imaging sessions before and after contrast administration on 2 consecutive days. Ferumoxtran-10 was administered immediately after the first scan. The three-dimensional spatial distribution of the pelvic lymph nodes was determined in relation to adjacent vessels and other musculoskeletal landmarks, from which guidelines for determining a nodal CTV in individual patients were developed. Results: On average, 30 lymph nodes (range, five to 62 nodes) were identified in each patient. The distribution of nodal distances to the closest artery or vein was observed to vary in different anatomic regions. Symmetrical three-dimensional margins of expansion around the distal para-aortic (12 mm), common iliac (10 mm), external iliac (9 mm), and internal iliac (10 mm) vessels, drawn in continuity with a 12-mm expansion anterior to the sacrum and a 22-mm expansion medial to the pelvic sidewall, were shown to encompass the majority of detectable lymph nodes in most patients. Conclusion: Use of MR lymphography with ferumoxtran-10 provides an objective description of lymph node locations for radiotherapy planning. Use of this nodal CTV model in clinical practice could ensure a high probability of encompassing the regions at risk of harboring metastatic disease while minimizing the dose to adjacent normal tissues.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Refinement of Treatment Setup and Target Localization Accuracy Using Three-Dimensional Cone-Beam Computed Tomography for Stereotactic Body Radiotherapy

Purposes: To quantitatively compare two-dimensional (2D) orthogonal kV with three-dimensional (3D) cone-beam CT (CBCT) for target localization; and to assess intrafraction motion with kV images in patients undergoing stereotactic body radiotherapy (SBRT). Methods and Materials: A total of 50 patients with 58 lesions received 178 fractions of SBRT. After clinical setup using in-room lasers and skin/cradle marks placed at simulation, patients were imaged and repositioned according to orthogonal kV/MV registration of bony landmarks to digitally reconstructed radiographs from the planning CT. A subsequent CBCT was registered to the planning CT using soft tissue information, and the resultant 'residual error' was measured and corrected before treatment. Posttreatment 2D kV and/or 3D CBCT images were compared with pretreatment images to determine any intrafractional position changes. Absolute averages, statistical means, standard deviations, and root mean square (RMS) values of observed setup error were calculated. Results: After initial setup to external marks with laser guidance, 2D kV images revealed vector mean setup deviations of 0.67 cm (RMS). Cone-beam CT detected residual setup deviations of 0.41 cm (RMS). Posttreatment imaging demonstrated intrafractional variations of 0.15 cm (RMS). The individual shifts in three standard orthogonal planes showed no obvious directional biases. Conclusions: After localization based on superficial markings in patients undergoing SBRT, orthogonal kV imaging detects setup variations of approximately 3 to 4 mm in each direction. Cone-beam CT detects residual setup variations of approximately 2 to 3 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Application of High-Dose, Image-Guided Intensity-Modulated Radiotherapy in High-Risk Prostate Cancer

Purpose: To report the feasibility and early toxicity of dose-escalated image-guided IMRT to the pelvic lymph nodes (LN), prostate (P), and seminal vesicles (SV). Methods and Materials: A total of 103 high-risk prostate cancer patients received two-phase, dose-escalated, image-guided IMRT with 3 years of androgen deprivation therapy. Clinical target volumes (CTVs) were delineated using computed tomography/magnetic resonance co-registration and included the prostate, portions of the SV, and the LN. Planning target volume margins (PTV) used were as follows: P (10 mm, 7 mm posteriorly), SV (10 mm), and LN (5 mm). Organs at risk (OaR) were the rectal and bladder walls, femoral heads, and large and small bowel. The IMRT was planned with an intended dose of 55.1 Gy in 29 fractions to all CTVs (Phase 1), with P+SV consecutive boost of 24.7 Gy in 13 fractions. Daily online image guidance was performed using bony landmarks and intraprostatic markers. Feasibility criteria included delivery of intended doses in 80% of patients, 95% of CTV displacements incorporated within PTV during Phase 1, and acute toxicity rate comparable to that of lower-dose pelvic techniques. Results: A total of 91 patients (88%) received the total prescription dose. All patients received at least 72 Gy. In Phase 1, 63 patients (61%) received the intended 55.1 Gy, whereas 87% of patients received at least 50 Gy. Dose reductions were caused by small bowel and rectal wall constraints. All CTVs received the planned dose in >95% of treatment fractions. There were no Radiation Therapy Oncology Group acute toxicities greater than Grade 3, although there were five incidences equivalent to Grade 3 within a median follow-up of 23 months. Conclusion: These results suggest that dose escalation to the PLN+P+SV using IMRT is feasible, with acceptable rates of acute toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Impact of Interfraction Catheter Movement in High-Dose Rate Prostate Brachytherapy

Purpose: To evaluate the impact of interfraction catheter movement on dosimetry in prostate high-dose-rate (HDR) brachytherapy. Methods and Materials: Fifteen patients were treated with fractionated HDR brachytherapy. Implants were performed on day 1 under transrectal ultrasound guidance. A computed tomography (CT) scan was performed. Inverse planning simulated annealing was used for treatment planning. The first fraction was delivered on day 1. A cone beam CT (CBCT) was performed on day 2 before the second fraction was given. A fusion of the CBCT and CT was performed using intraprostatic gold markers as landmarks. Initial prostate and urethra contours were transferred to the CBCT images. Bladder and rectum contours were drawn, and catheters were digitized on the CBCT. The planned treatment was applied to the CBCT dataset, and dosimetry was analyzed and compared to the initial dose distribution. This process was repeated after a reoptimization was performed, using the same constraints used on day 1. Results: Mean interfraction catheter displacement was 5.1 mm. When we used the initial plan on day 2, the mean prostate V100 (volume receiving 100 Gy or more) decreased from 93.8% to 76.2% (p < 0.01). Rectal V75 went from 0.75 cm{sup 3} to 1.49 cm{sup 3} (p < 0.01). A reoptimization resulted in a mean prostate V100 of 88.1%, closer to the initial plan (p = 0.05). Mean rectal V75 was also improved with a value of 0.59 cm{sup 3}. There was no significant change in bladder and urethra dose on day 2. Conclusions: A mean interfraction catheter displacement of 5.1 mm results in a significant decrease in prostate V100 and an increase in rectum dose. A reoptimization before the second treatment improves dose distribution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of Planning Target Volume Margins for Intensity-Modulated Radiotherapy of the Prostate Gland: Role of Daily Inter- and Intrafraction Motion

Purpose: To determine planning target volume margins for prostate intensity-modulated radiotherapy based on inter- and intrafraction motion using four daily localization techniques: three-point skin mark alignment, volumetric imaging with bony landmark registration, volumetric imaging with implanted fiducial marker registration, and implanted electromagnetic transponders (beacons) detection. Methods and Materials: Fourteen patients who underwent definitive intensity-modulated radiotherapy for prostate cancer formed the basis of this study. Each patient was implanted with three electromagnetic transponders and underwent a course of 39 treatment fractions. Daily localization was based on three-point skin mark alignment followed by transponder detection and patient repositioning. Transponder positioning was verified by volumetric imaging with cone-beam computed tomography of the pelvis. Relative motion between the prostate gland and bony anatomy was quantified by offline analyses of daily cone-beam computed tomography. Intratreatment organ motion was monitored continuously by the Calypso (registered) System for quantification of intrafraction setup error. Results: As expected, setup error (that is, inter- plus intrafraction motion, unless otherwise stated) was largest with skin mark alignment, requiring margins of 7.5 mm, 11.4 mm, and 16.3 mm, in the lateral (LR), longitudinal (SI), and vertical (AP) directions, respectively. Margin requirements accounting for intrafraction motion were smallest for transponder detection localization techniques, requiring margins of 1.4 mm (LR), 2.6 mm (SI), and 2.3 mm (AP). Bony anatomy alignment required 2.1 mm (LR), 9.4 mm (SI), and 10.5 mm (AP), whereas image-guided marker alignment required 2.8 mm (LR), 3.7 mm (SI), and 3.2 mm (AP). No marker migration was observed in the cohort. Conclusion: Clinically feasible, rapid, and reliable tools such as the electromagnetic transponder detection system for pretreatment target localization and, subsequently, intratreatment target location monitoring allow clinicians to reduce irradiated volumes and facilitate safe dose escalation, where appropriate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Body Mass Index on Outcomes After Conformal Radiotherapy in Patients With Prostate Cancer

Purpose: Several retrospective analyses have suggested that obese men with prostate cancer treated with external beam radiotherapy (EBRT) have outcomes inferior to those of normal-weight men. However, a recently presented analysis for the first time challenged this association between body mass index (BMI) and treatment failure. It is therefore important to provide further data on this issue. Methods and Materials: This was a retrospective analysis of 564 men treated with risk-adapted conformal EBRT at a single institution. Low-risk patients received EBRT alone, and the other patients received EBRT plus endocrine treatment. In addition, high-risk patients were treated to higher EBRT doses (74 Gy). A rectal balloon catheter for internal immobilization, which can be identified on portal images, was used in 261 patients (46%). Thus, localization did not rely on bony landmarks alone in these cases. Results: The median BMI was 26, and 15% of patients had BMI {>=}30. Neither univariate nor multivariate analyses detected any significant impact of BMI on biochemical relapse, prostate cancer-specific survival, or overall survival. The 5-year biochemical relapse rate was 21% and prostate cancerspecific survival 96%. Conclusions: The present analysis of a large cohort of consecutively treated patients suggests that efforts to reduce prostate movement and geographic miss might result in comparable outcomes in obese and normal-weight patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differences in Effective Target Volume Between Various Techniques of Accelerated Partial Breast Irradiation

Purpose: Different cavity expansions are used to define the clinical target volume (CTV) for accelerated partial breast irradiation (APBI) delivered via balloon brachytherapy (1 cm) vs. three-dimensional conformal radiotherapy (3D-CRT) (1.5 cm). Previous studies have argued that the CTVs generated by these different margins are effectively equivalent. In this study, we use deformable registration to assess the effective CTV treated by balloon brachytherapy on clinically representative 3D-CRT planning images. Methods and Materials: Ten patients previously treated with the MammoSite were studied. Each patient had two computed tomography (CT) scans, one acquired before and one after balloon implantation. In-house deformable registration software was used to deform the MammoSite CTV onto the balloonless CT set. The deformed CTV was validated using anatomical landmarks common to both CT scans. Results: The effective CTV treated by the MammoSite was on average 7% {+-} 10% larger and 38% {+-} 4% smaller than 3D-CRT CTVs created using uniform expansions of 1 and 1.5 cm, respectively. The average effective CTV margin was 1.0 cm, the same as the actual MammoSite CTV margin. However, the effective CTV margin was nonuniform and could range from 5 to 15 mm in any given direction. Effective margins <1 cm were attributable to poor cavity-balloon conformance. Balloon size relative to the cavity did not significantly correlate with the effective margin. Conclusion: In this study, the 1.0-cm MammoSite CTV margin treated an effective volume that was significantly smaller than the 3D-CRT CTV based on a 1.5-cm margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated Planning of Tangential Breast Intensity-Modulated Radiotherapy Using Heuristic Optimization

Purpose: To present an automated technique for two-field tangential breast intensity-modulated radiotherapy (IMRT) treatment planning. Method and Materials: A total of 158 planned patients with Stage 0, I, and II breast cancer treated using whole-breast IMRT were retrospectively replanned using automated treatment planning tools. The tools developed are integrated into the existing clinical treatment planning system (Pinnacle{sup 3}) and are designed to perform the manual volume delineation, beam placement, and IMRT treatment planning steps carried out by the treatment planning radiation therapist. The automated algorithm, using only the radio-opaque markers placed at CT simulation as inputs, optimizes the tangential beam parameters to geometrically minimize the amount of lung and heart treated while covering the whole-breast volume. The IMRT parameters are optimized according to the automatically delineated whole-breast volume. Results: The mean time to generate a complete treatment plan was 6 min, 50 s {+-} 1 min 12 s. For the automated plans, 157 of 158 plans (99%) were deemed clinically acceptable, and 138 of 158 plans (87%) were deemed clinically improved or equal to the corresponding clinical plan when reviewed in a randomized, double-blinded study by one experienced breast radiation oncologist. In addition, overall the automated plans were dosimetrically equivalent to the clinical plans when scored for target coverage and lung and heart doses. Conclusion: We have developed robust and efficient automated tools for fully inversed planned tangential breast IMRT planning that can be readily integrated into clinical practice. The tools produce clinically acceptable plans using only the common anatomic landmarks from the CT simulation process as an input. We anticipate the tools will improve patient access to high-quality IMRT treatment by simplifying the planning process and will reduce the effort and cost of incorporating more advanced planning into clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Organ Motion During Chemoradiotherapy of Rectal Cancer Using Cone-Beam Computed Tomography

Purpose: There has been no previously published data related to the quantification of rectal motion using cone-beam computed tomography (CBCT) during standard conformal long-course chemoradiotherapy. The purpose of the present study was to quantify the interfractional changes in rectal movement and dimensions and rectal and bladder volume using CBCT and to quantify the bony anatomy displacements to calculate the margins required to account for systematic ({Sigma}) and random ({sigma}) setup errors. Methods and Materials: CBCT images were acquired from 16 patients on the first 3 days of treatment and weekly thereafter. The rectum and bladder were outlined on all CBCT images. The interfraction movement was measured using fixed bony landmarks as references to define the rectal location (upper, mid, and low), The maximal rectal diameter at the three rectal locations was also measured. The bony anatomy displacements were quantified, allowing the calculation of systematic ({Sigma}) and random ({sigma}) setup errors. Results: A total of 123 CBCT data sets were analyzed. Analysis of variance for standard deviation from planning scans showed that rectal anterior and lateral wall movement differed significantly by rectal location. Anterior and lateral rectal wall movements were larger in the mid and upper rectum compared with the low rectum. The posterior rectal wall movement did not change significantly with the rectal location. The rectal diameter changed more in the mid and upper than in the low rectum. No consistent relationship was found between the rectal and bladder volume and time, nor was a significant relationship found between the rectal volume and bladder volume. Conclusions: In the present study, the anterior and lateral rectal movement and rectal diameter were found to change most in the upper rectum, followed by the mid rectum, with the smallest changes seen in the low rectum. Asymmetric margins are warranted to ensure phase 2 coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of Imaging With Pathology in Laryngeal Cancer: Accuracy of the Registration Methodology

Purpose: To investigate the feasibility and accuracy of an automated method to validate gross tumor volume (GTV) delineations with pathology in laryngeal and hypopharyngeal cancer. Methods and Materials: High-resolution computed tomography (CT{sub HR}), magnetic resonance imaging (MRI), and positron emission tomography (PET) scans were obtained from 10 patients before total laryngectomy. The GTV was delineated separately in each imaging modality. The laryngectomy specimen was sliced transversely in 3-mm-thick slices, and whole-mount hematoxylin-eosin stained (H and E) sections were obtained. A pathologist delineated tumor tissue in the H and E sections (GTV{sub PATH}). An automatic three-dimensional (3D) reconstruction of the specimen was performed, and the CT{sub HR}, MRI, and PET were semiautomatically and rigidly registered to the 3D specimen. The accuracy of the pathology-imaging registration and the specimen deformation and shrinkage were assessed. The tumor delineation inaccuracies were compared with the registration errors. Results: Good agreement was observed between anatomical landmarks in the 3D specimen and in the in vivo images. Limited deformations and shrinkage (3% {+-} 1%) were found inside the cartilage skeleton. The root mean squared error of the registration between the 3D specimen and the CT, MRI, and PET was on average 1.5, 3.0, and 3.3 mm, respectively, in the cartilage skeleton. The GTV{sub PATH} volume was 7.2 mL, on average. The GTVs based on CT, MRI, and PET generated a mean volume of 14.9, 18.3, and 9.8 mL and covered the GTV{sub PATH} by 85%, 88%, and 77%, respectively. The tumor delineation inaccuracies exceeded the registration error in all the imaging modalities. Conclusions: Validation of GTV delineations with pathology is feasible with an average overall accuracy below 3.5 mm inside the laryngeal skeleton. The tumor delineation inaccuracies were larger than the registration error. Therefore, an accurate histological validation of anatomical and functional imaging techniques for GTV delineation is possible in laryngeal cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying the Interfractional Displacement of the Gastroesophageal Junction During Radiation Therapy for Esophageal Cancer

Purpose: Accounting for interfractional changes in tumor location improves the accuracy of radiation treatment delivery. The purpose of this study was to quantify the interfractional displacement of the gastroesophageal junction (GEJ) based on standard treatment setup in patients with esophageal cancer undergoing radiation therapy. Methods and Materials: Free-breathing four-dimensional computed tomography (4D-CT) datasets were acquired weekly from 22 patients during treatment for esophageal adenocarcinoma. Scans were registered to baseline (simulation) 4D-CT scans by using bony landmarks. The distance between the center of the GEJ contour on the simulation scan and the mean location of GEJ centers on subsequent scans was used to assess changes in GEJ location between fractions; displacement was also correlated with clinical and respiratory variables. Results: The mean absolute random error was 1.69 mm (range, 0.11-4.11 mm) in the lateral direction, 1.87 mm (range, 0.51-4.09 mm) in the anterior-posterior (AP) direction, and 3.09 mm (range, 0.99-6.16 mm) in the superior-inferior (SI) direction. The mean absolute systemic GEJ displacement between fractions was 2.88 mm lateral ({>=}5 mm in 14%), mostly leftward; 2.90 mm ({>=}5 mm in 14%) AP, mostly anterior; and 6.77 mm ({>=}1 cm in 18%) SI, mostly inferior. Variations in tidal volume and diaphragmatic excursion during treatment correlated strongly with systematic SI GEJ displacement (r = 0.964, p < 0.0001; and r = 0.944, p < 0.0001, respectively) and moderately with systematic AP GEJ displacement (r = 0.678, p = 0.0005; r = 0.758, p < 0.0001, respectively). Systematic displacement in the inferior direction resulted in higher-than-intended doses ({>=}60 Gy) to the GEJ, with increased hot-spot to the adjacent stomach and lung base. Conclusion: We found large (>1-cm) interfractional displacements in the GEJ in the SI (especially inferior) direction that was not accounted for when skeletal alignment alone was used for patient positioning. Because systematic displacement in the SI direction had dosimetric impact and correlated with tidal volume, better accounting for depth of breathing is needed to reduce interfractional variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cherenkov Video Imaging Allows for the First Visualization of Radiation Therapy in Real Time

Purpose: To determine whether Cherenkov light imaging can visualize radiation therapy in real time during breast radiation therapy. Methods and Materials: An intensified charge-coupled device (CCD) camera was synchronized to the 3.25-μs radiation pulses of the clinical linear accelerator with the intensifier set × 100. Cherenkov images were acquired continuously (2.8 frames/s) during fractionated whole breast irradiation with each frame an accumulation of 100 radiation pulses (approximately 5 monitor units). Results: The first patient images ever created are used to illustrate that Cherenkov emission can be visualized as a video during conditions typical for breast radiation therapy, even with complex treatment plans, mixed energies, and modulated treatment fields. Images were generated correlating to the superficial dose received by the patient and potentially the location of the resulting skin reactions. Major blood vessels are visible in the image, providing the potential to use these as biological landmarks for improved geometric accuracy. The potential for this system to detect radiation therapy misadministrations, which can result from hardware malfunction or patient positioning setup errors during individual fractions, is shown. Conclusions: Cherenkoscopy is a unique method for visualizing surface dose resulting in real-time quality control. We propose that this system could detect radiation therapy errors in everyday clinical practice at a time when these errors can be corrected to result in improved safety and quality of radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Near Real-Time Assessment of Anatomic and Dosimetric Variations for Head and Neck Radiation Therapy via Graphics Processing Unit–based Dose Deformation Framework

Purpose: The purpose of this study was to systematically monitor anatomic variations and their dosimetric consequences during intensity modulated radiation therapy (IMRT) for head and neck (H&N) cancer by using a graphics processing unit (GPU)-based deformable image registration (DIR) framework. Methods and Materials: Eleven IMRT H&N patients undergoing IMRT with daily megavoltage computed tomography (CT) and weekly kilovoltage CT (kVCT) scans were included in this analysis. Pretreatment kVCTs were automatically registered with their corresponding planning CTs through a GPU-based DIR framework. The deformation of each contoured structure in the H&N region was computed to account for nonrigid change in the patient setup. The Jacobian determinant of the planning target volumes and the surrounding critical structures were used to quantify anatomical volume changes. The actual delivered dose was calculated accounting for the organ deformation. The dose distribution uncertainties due to registration errors were estimated using a landmark-based gamma evaluation. Results: Dramatic interfractional anatomic changes were observed. During the treatment course of 6 to 7 weeks, the parotid gland volumes changed up to 34.7%, and the center-of-mass displacement of the 2 parotid glands varied in the range of 0.9 to 8.8 mm. For the primary treatment volume, the cumulative minimum and mean and equivalent uniform doses assessed by the weekly kVCTs were lower than the planned doses by up to 14.9% (P=.14), 2% (P=.39), and 7.3% (P=.05), respectively. The cumulative mean doses were significantly higher than the planned dose for the left parotid (P=.03) and right parotid glands (P=.006). The computation including DIR and dose accumulation was ultrafast (∼45 seconds) with registration accuracy at the subvoxel level. Conclusions: A systematic analysis of anatomic variations in the H&N region and their dosimetric consequences is critical in improving treatment efficacy. Nearly real-time assessment of anatomic and dosimetric variations is feasible using the GPU-based DIR framework. Clinical implementation of this technology may enable timely plan adaptation and improved outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Expert Consensus Contouring Guidelines for Intensity Modulated Radiation Therapy in Esophageal and Gastroesophageal Junction Cancer

Purpose/Objective(s): Current guidelines for esophageal cancer contouring are derived from traditional 2-dimensional fields based on bony landmarks, and they do not provide sufficient anatomic detail to ensure consistent contouring for more conformal radiation therapy techniques such as intensity modulated radiation therapy (IMRT). Therefore, we convened an expert panel with the specific aim to derive contouring guidelines and generate an atlas for the clinical target volume (CTV) in esophageal or gastroesophageal junction (GEJ) cancer. Methods and Materials: Eight expert academically based gastrointestinal radiation oncologists participated. Three sample cases were chosen: a GEJ cancer, a distal esophageal cancer, and a mid-upper esophageal cancer. Uniform computed tomographic (CT) simulation datasets and accompanying diagnostic positron emission tomographic/CT images were distributed to each expert, and the expert was instructed to generate gross tumor volume (GTV) and CTV contours for each case. All contours were aggregated and subjected to quantitative analysis to assess the degree of concordance between experts and to generate draft consensus contours. The panel then refined these contours to generate the contouring atlas. Results: The κ statistics indicated substantial agreement between panelists for each of the 3 test cases. A consensus CTV atlas was generated for the 3 test cases, each representing common anatomic presentations of esophageal cancer. The panel agreed on guidelines and principles to facilitate the generalizability of the atlas to individual cases. Conclusions: This expert panel successfully reached agreement on contouring guidelines for esophageal and GEJ IMRT and generated a reference CTV atlas. This atlas will serve as a reference for IMRT contours for clinical practice and prospective trial design. Subsequent patterns of failure analyses of clinical datasets using these guidelines may require modification in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mapping Patterns of Ipsilateral Supraclavicular Nodal Metastases in Breast Cancer: Rethinking the Clinical Target Volume for High-risk Patients

Purpose: To map the location of metastatic supraclavicular (SCV) lymph nodes (LNMs) in breast cancer patients with SCV node involvement and determine whether and where the radiation therapy clinical target volume (CTV) of this region could be modified in high-risk subsets. Methods and Materials: Fifty-five patients with metastatic SCV LNMs were eligible for geographic mapping and atlas coverage analysis. All LNMs and their epicenters were registered proportionally by referencing the surrounding landmarks onto simulation computed tomography images of a standard patient. CTVs based on selected SCV atlases, including the one by the Radiation Therapy Oncology Group (RTOG) were contoured. A modified SCV CTV was tried and shown to have better involved-node coverage and thus theoretically improved prophylaxis in this setting. Results: A total of 50 (91%) and 45 (81.8%) patients had LNMs in the medial and lateral SCV subregions, respectively. Also, 36 patients (65.5%) had LNMs located at the junction of the jugular-subclavian veins. All nodes were covered in only 25.5% to 41.8% of patients by different atlases. The RTOG atlas covered all nodes in 25.5% of patients. Stratified by the nodes in all the patients as a whole, 49.2% to 81.3% were covered, and the RTOG atlas covered 62.6%. The lateral and posterior borders were the most overlooked locations. Modification by extending the borders to natural anatomic barriers allowed the new CTV to cover all the nodes in 81.8% of patients and encompass 96.1% of all the nodes. Conclusions: According to the distribution of SCV LNMs, the extent of existing atlases might not be adequate for potential metastatic sites in certain groups of patients. The extension of the lateral and posterior CTV borders in high-risk or recurrent patients might be a reasonable approach for increasing coverage. However, additional data in more homogeneous populations with localized disease are needed before routine application.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In the Modern Treatment Era, Is Breast Conservation Equivalent to Mastectomy in Women Younger Than 40 Years of Age? A Multi-Institution Study

Purpose: Mastectomy is often recommended for women ≤40 years of age with breast cancer, as young women were under-represented in the landmark trials comparing breast conservation therapy (BCT) to mastectomy. We hypothesized that, in the modern treatment era, BCT and mastectomy result in equivalent local control rates in young women. Methods and Materials: Breast cancer cases arising between 1975 and 2013 in women ≤40 years old were collected from the tumor registries of 2 large healthcare systems in Utah. Kaplan-Meier estimates and Cox proportional hazards models were used to analyze freedom from locoregional recurrence (FFLR), overall survival (OS), and relapse-free survival (RFS). Results: This analysis identified 853 BCT candidates. A comparison of BCT to mastectomy after 2000 showed FFLR, RFS, and OS were all similar. Rate for FFLR at 10 years was 94.9% versus 92.1% for BCT and mastectomy, respectively (P=.57). For women whose cancer was diagnosed after 2000, who received BCT, FFLR and RFS rates were improved compared to those whose cancer was diagnosed prior to 2000 (P<.05), whereas OS (P=.46) rates were similar. Among those who underwent mastectomy, FFLR, OS, and RFS were significantly improved (P<.05) with diagnosis after 2000. Conclusions: FFLR rates for young women, ≤40 years of age, have significantly improved for BCT and mastectomy over time. If patients were treated after 2000, BCT appears to be safe and equivalent to mastectomy at 10 years in terms of FFLR, OS, and RFS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Quest for Evidence for Proton Therapy: Model-Based Approach and Precision Medicine

Purpose: Reducing dose to normal tissues is the advantage of protons versus photons. We aimed to describe a method for translating this reduction into a clinically relevant benefit. Methods and Materials: Dutch scientific and health care governance bodies have recently issued landmark reports regarding generation of relevant evidence for new technologies in health care including proton therapy. An approach based on normal tissue complication probability (NTCP) models has been adopted to select patients who are most likely to experience fewer (serious) adverse events achievable by state-of-the-art proton treatment. Results: By analogy with biologically targeted therapies, the technology needs to be tested in enriched cohorts of patients exhibiting the decisive predictive marker: difference in normal tissue dosimetric signatures between proton and photon treatment plans. Expected clinical benefit is then estimated by virtue of multifactorial NTCP models. In this sense, high-tech radiation therapy falls under precision medicine. As a consequence, randomizing nonenriched populations between photons and protons is predictably inefficient and likely to produce confusing results. Conclusions: Validating NTCP models in appropriately composed cohorts treated with protons should be the primary research agenda leading to urgently needed evidence for proton therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗