Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “joint”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Structural Analysis and Testing of Multi-nut Joint for TriTruss Structure

Axial and bending tests for a multi-nut joint in the TriTruss structure were conducted at NASA Langley Research Center (LaRC). This report describes the test procedures used for the axial and bending tests of the multi-nut joint, along with the test results. The joint's equivalent axial stiffness (EA) and equivalent bending stiffness (EI) were characterized based on these test results and are presented in this report. Additionally, finite element models (FEMs) of the axial and bending test specimens were developed, and the predicted axial and bending responses of the multi-nut joint were compared and validated with the test results.

Joint Test↗

Multiple‐Repeated Plasma Surface Treatments for Significantly Improving Bonding Performance of Metal‐Carbon‐Fiber‐Reinforced Thermoplastic Polymer Dissimilar Adhesive Joints

This work investigates how multiple‐repeated plasma surface treatments can significantly enhance adhesively bonded metal‐carbon‐fiber‐reinforced thermoplastic polymer (CFRTP) dissimilar joints, a topic that has been rarely investigated compared to other parameters during the plasma treatment process. By conducting double cantilever beam tests on adhesively bonded AA6061‐carbon‐fiber‐reinforced polyphthalamide (CFRPPA) dissimilar joints, it is shown that the average Mode I specific fracture energy after 20 repetitions of the same plasma treatment, using processing parameters without noticeably changing surface roughness, can be improved and saturated up to almost 2000% compared to non‐treated joints and almost 240% compared to a single plasma treatment commonly used in the literature. The improvement can be attributed to the enhanced chemical bonding at the CFRPPA‐adhesive interface. This study is important for achieving strong bonding performance of CFRTP‐related structural joints using multiple plasma treatments, a simple and effective method.

36 MATERIALS SCIENCE↗

Scale-Up of Friction Self-piercing Riveting Process for Multi-material Joints

A single-class joining process known as “friction self-piercing riveting (F-SPR)” has been developed for joining various low-ductility lightweight materials on a laboratory scale. The frictional heat generated during the F-SPR process improved local ductility, resulting in crack-free joints and robust mechanical performance. This innovative joining technology was further advanced through the scale-up of the process using a new system with several key features (e.g., automatic rivet feeding and clamping system, vacuum system) toward industry readiness. The new integrated F-SPR systems were effectively demonstrated for joining different material combinations (e.g., carbon fiber composite to 7075 Al alloy, 7075 Al alloy to 7075 Al alloy, and 7075 Al alloy to casting Al Aural 5) with a unified technique. Crack-free joint with adequate mechanical interlocking resulted in good mechanical joint strength for each material combination. Then, the process was successfully scaled up by producing multiple joints without any cracks on larger CFC-Al and Al-Al components by the new integrated system, bringing it closer to industrial application.

Lim, Yong Chae [ORNL] (ORCID:0000000321773988)↗

Microstructural Coarsening Kinetics and Mechanical Property Changes in Long-Term Aged Sn–Pb–Sb Solder Joints

Tin-lead-antimony (50Sn–47Pb–3Sb wt.%) soldered assemblies were mechanically tested approximately 30 years after initial production and found to have solder joints of reduced strength. The microstructure of this solder alloy exhibits a ternary eutectic structure with Sn-rich, Pb-rich, and SnSb phases. Accelerated aging was performed to evaluate solder microstructural coarsening and associated strength of laboratory solder joints to correlate these properties to the “naturally aged” solder joints. Isothermal aging was conducted at room temperature, 55, 70, 100, and 135 °C and aging times that ranged from 0.1 to 365 days. The coarsening kinetics of the Pb-rich phase were determined through optical microscopy and image analysis methods established in previous studies on binary Sn–Pb solder. A kinetic equation was developed with time exponent n of 0.43 and activation energy of 24000 J/mol, suggesting grain boundary diffusion or other fast diffusion pathways controlling the microstructural evolution. Compression testing and Vickers microhardness showed significant strength loss within the first 20–30 days after soldering; then, the microstructure and mechanical properties changed more slowly over long periods of time. Further, by combining accelerated aging data and the microstructure-based kinetics, strength predictions were made that match well with the properties of the actual soldered assemblies naturally aged for 30 years. However, aging at the highest temperature of 135 °C produced anomalous behavior suggesting that extraneous aging mechanisms are active. Therefore, data obtained at this temperature or higher should not be used. Overall, the combined microstructural and mechanical property methods used in this study confirmed that the observed reduction in strength of ~ 30-year-old solder joints can be accounted for by the microstructural coarsening that takes place during long-term solid-state aging.

36 MATERIALS SCIENCE↗

Correlation of Surface Acoustic Wave (SAW) force myography sensor output with elbow joint torque

Accurate assessment of skeletal muscle forces and net joint torque is essential for preventing fatigue-related injuries, optimizing physical training, and monitoring disease progression in neuromuscular conditions. However, existing joint torque evaluation techniques are hindered by limited portability and high operational costs, confining their use to controlled laboratory or clinical settings. Despite substantial advances in wearable joint torque estimation systems, ongoing challenges such as power constraints, bulky wired setups, and susceptibility to environmental or motion artifacts underscore the urgent need for truly batteryless, wireless solutions deployable in real-world settings. This paper proposes a novel surface acoustic wave (SAW)-based force myography (FMG) system for noninvasive measurement of joint torque, validated against a gold-standard electromechanical dynamometer. The approach uses a single SAW sensor embedded in an armband to detect volumetric biceps brachii changes, with a second-order polynomial mapping sensor output and elbow angle to torque. Seven participants were tested in both isometric (15°–90°) and isokinetic (10°/s and 20°/s) supinated elbow flexion tasks. Under isometric conditions, subject-specific calibration achieved a normalized root-mean-square error (NRMSE) of 13.6% ± 6.0% and R 2 = 0.834 ± 0.180, while a group-level model yielded 14.4% ± 6.8% and 0.808 ± 0.208, respectively. For isokinetic trials, the group model produced an NRMSE of 24.1% ± 6.6% at 10°/s and 24.9% ± 08.9% at 20°/s, highlighting the feasibility of using a single-sensor SAW-FMG setup across different speeds. Because SAW devices support wireless, battery-free operation, the proposed system offers a pathway to portable, real-time monitoring for sports medicine, rehabilitation, and clinical diagnostics.

36 MATERIALS SCIENCE↗

Corrosion Resistance of Lignin-Based Thermoplastic Adhesive-Bonded Aluminum Joints

Adhesive-bonded joints are essential for lightweight, multimaterial automotive structures. We developed a lignin-based thermoplastic adhesive with adhesion strength comparable to conventional epoxy adhesives (20–23 MPa), while offering exceptional durability, recyclability, and corrosion resistance. Unlike commercial epoxy adhesives requiring refrigerated storage, our adhesive retains its bonding potential after a year of ambient conditioning. Bonded joints can be repeatedly disassembled and rejoined with less than 2% strength loss. After 500 h of salt fog exposure, the adhesive-bonded aluminum joints exhibited a 24% strength reduction, compared to 61% reduction in strength of joints based on a commercial epoxy adhesive.

Yu, Zeyang [ORNL] (ORCID:0000000209002374)↗

Development of thermal joints for conduction-cooling applications

Abstract In support of the development of conduction-cooled superconducting radiofrequency (SRF) niobium cavities for use in continuous-wave linear accelerators, an experimental study of thermal contact resistance was performed on bolted joints using high-purity niobium, aluminium, and copper along with Apiezon N grease and indium foil as interfacial materials. The geometry of each joint investigated aims at replicating the design adopted in conduction-cooled SRF cavities currently under development at Jefferson Lab. The materials’ thermal conductivity and the joints’ thermal resistance were measured in the temperature range of 3.5 - 10 K. The results showed that the low thermal contact resistance of 2-4 K·cm 2 /W at 4.3 K achieved with Al-In-Nb and Al-Apiezon N-Cu joints should allow the operation of conduction-cooled SRF cavities at a targeted accelerating gradient of ∼10 MV/m.

Lewis, J. [Old Dominion University]↗

Improved high-temperature gimbal joint

Development and characteristics of bellows gimbal joint for reduction of thermal stress effects are discussed. Reactions of designed joint to changes in temperature are described. Illustrations of conventional gimbal joint and improved gimbal joint are provided.

Winemiller, J. R.↗

Evaluation of tantalum 316 stainless steel transition joints

Tubular transition joints providing a metallurgically bonded connection between tantalum and 316 stainless steel pipe sections were comparatively evaluated for durability under thermal cycling conditions approximating the operation of a SNAP-8 mercury boiler. Both coextruded and vacuum brazed transition joints of 50mm (2 inch) diameter were tested by thermal cycling 100 times between 730 C and 120 C(1350 F and 250 F) in a high vacuum environment. The twelve evaluated transition joints survived the full test sequence without developing leaks, although liquid penetrant bond line indications eventually developed in all specimens. The brazed transition joints exhibited the best dimensional stability and bond line durability.

Stoner, D. R.↗

Quick-connect threaded attachment joint

Joint is self-aligning and tightens with only sixty-five degrees of rotation for quick connects and disconnects. Made of injection-molded plastics or cast or machined aluminum, joint can carry wires, tubes, liquids, or gases. When two parts of joint are brought together, their shapes align them. Small projections on male section and slots on female section further aid alignment; slight rotation of male form engages projections in slots. At this point, threads engage and male section is rotated until joint is fully engaged.

Lucy, M. H.↗

Wrist joint assembly

A wrist joint assembly is provided for use with a mechanical manipulator arm for finely positioning an end-effector carried by the wrist joint on the terminal end of the manipulator arm. The wrist joint assembly is pivotable about a first axis to produce a yaw motion, a second axis is to produce a pitch motion, and a third axis to produce a roll motion. The wrist joint assembly includes a disk segment affixed to the terminal end of the manipulator arm and a first housing member, a second housing member, and a third housing member. The third housing member and the mechanical end-effector are moved in the yaw, pitch, and roll motion. Drive means are provided for rotating each of the housings about their respective axis which includes a cluster of miniature motors having spur gears carried on the output drive shaft which mesh with a center drive gear affixed on the housing to be rotated.

Kersten, L.↗

Design fabrication and test of graphite/polyimide composite joints and attachments for advanced aerospace vehicles

Graphite/polyimide (Gr/PI) bolted and bonded joints were investigated. Possible failure modes and the design loads for the four generic joint types are discussed. Preliminary sizing of a type 1 joint, bonded and bolted configuration is described, including assumptions regarding material properties and sizing methodology. A general purpose finite element computer code is described that was formulated to analyze single and double lap joints, with and without tapered adherends, and with user-controlled variable element size arrangements. An initial order of Celion 6000/PMR-15 prepreg was received and characterized.

Source record↗

Planar scarf joints in composite repair

This study examined the effects of varying certain important geometric parameters on the stresses in an adhesive repair of a thin composite laminate. The repair, a planar scarf joint with a doubler, was studied using finite element methods at scarf angles of 6 deg and 12 deg, damage lengths between 2.5 mm and 25 mm and doubler overlaps between 10 mm and 40 mm. Finite element models also showed that significant stress peaks occur at the ends of the scarf joint adhesive, similar to shear lag phenomena in lap joints. A bending model of the planar scarf joint with a doubler, based on mechanics of materials theory, was also developed.

Adkins, D. W.↗

Design, fabrication and test of graphite/polyimide composite joints and attachments for advanced aerospace vehicles

Bonded and bolted designs are presented for each of four major attachment types. Prepreg processing problems are discussed and quality control data are given for lots 2W4604, 2W4632 and 2W4643. Preliminary design allowables test results for tension tests and compression tests of laminates are included. The final small specimen test matrix is defined and the configuration of symmetric step-lap joint specimens are shown. Finite element modeling studies of a double lap joint were performed to evaluate the number of elements required through the adhesive thickness to assess effects of various joint parameters on stress distributions. Results of finite element analyses assessing the effect of an adhesive fillet on the stress distribution in a double lap joint are examined.

Skoumal, D. E.↗

An analysis of interface crack in adhesively bonded lap shear joints

This paper presents an analytical study of interface crack problems in adhesively bonded lap shear joints. A convenient and accurate method of analysis is developed on the basis of conservation laws in elasticity and of the fundamental relationships in fracture mechanics of interface crack problems. The problem is eventually reduced to a system of linear algebraic equations of mixed-mode stress intensity factor solutions. One of the salient features of the present approach is that the interface crack-tip stress intensity solutions can be determined accurately and directly by the information extracted from the far field. Solutions of the interface crack problems in lap shear joints have been obtained for the cases of various adhesive/adherend material systems and geometric configurations of the crack and the joint. Of particular interest is the evaluation of the mixed-mode stress intensity factors and the associated energy release rates. They are determined explicitly to illustrate the fundamental nature of the joint fracture problem.

Wang, S. S.↗

Failure analyses of composite bolted joints

The complex failure behavior exhibited by bolted joints of graphite epoxy (Hercules AS/3501) was investigated for the net tension, bearing and shearout failure modes using combined analytical and experimental techniques. Plane stress, linear elastic, finite element methods were employed to determine the two dimensional state of stress resulting from a loaded hole in a finite width, semiinfinite strip. The stresses predicted by the finite element method were verified by experiment to lend credence to the analysis. The influence of joint geometric parameters on the state of stress and resultant strength of the joint was also studied. The resulting functional relationships found to exist between bolted joint strength and the geometric parameters, were applied in the formulation of semiempirical strength models for the basic failure modes. A point stress failure criterion was successfully applied as the failure criterion for the net tension and shearout failure modes.

Wilson, D. W.↗

Design, fabrication and test of graphite/polyimide composite joints and attachments for advanced aerospace vehicles

Results of an experimental program to develop several types of graphite/polyimide (GR/PI) bonded and bolted joints for lightly loaded flight components for advanced space transportation systems and high speed aircraft are presented. Tasks accomplished include: a literature survey; design of static discriminator specimens; design allowables testing; fabrication of test panels and specimens; small specimen testing; and standard joint testing. Detail designs of static discriminator specimens for each of the four major attachment types are presented. Test results are given for the following: (1) transverse tension of Celion 3000/PMR-15 laminate; (2) net tension of a laminate for both a loaded and unloaded bolt hole; (3) comparative testing of bonded and co-cured doublers along with pull-off tests of single and double bonded angles; (4) single lap shear tests, transverse tension and coefficient of thermal expansion tests of A7F (LARC-13 amide-imide modified) adhesive; and (5) tension tests of standard single lap, double lap, and symmetric step lap bonded joints. Also, included are results of a finite element analysis of a single lap bonded composite joint.

Barclay, D. L.↗

Design, Fabrication and Test of Graphite/Polyimide Composite Joints and Attachments for Advanced Aerospace Vehicles

Standard and advanced bonded joint concepts were evaluated to develop a data base for the design and analysis of advanced composite joints for use at elevated temperatures (561K (550F)). Design concepts for specific joint applications and the fundamental parameters controlling the static strength characteristics of such joints were identified. Test results are presented for rail shear and sandwich beam compression tests and tension tests of moisture conditioned specimens and bonded on "T" sections. Coefficients of thermal expansion data are presented for A7F (LARC 13 Amide-imide modified) adhesion. Static discriminator test results for type 1 and type 2 bonded and bolted preliminary attachment concepts are presented and discussed.

Cushman, J. B.↗