Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interval”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

The DAFT/FADA survey. I.Photometric redshifts along lines of sight to clusters in the z=[0.4,0.9] interval

As a contribution to the understanding of the dark energy concept, the Dark energy American French Team (DAFT, in French FADA) has started a large project to characterize statistically high redshift galaxy clusters, infer cosmological constraints from Weak Lensing Tomography, and understand biases relevant for constraining dark energy and cluster physics in future cluster and cosmological experiments. Aims. The purpose of this paper is to establish the basis of reference for the photo-z determination used in all our subsequent papers, including weak lensing tomography studies. This project is based on a sample of 91 high redshift (z {ge} 0.4), massive ({approx}> 3 x 10{sup 14} M{sub {circle_dot}}) clusters with existing HST imaging, for which we are presently performing complementary multi-wavelength imaging. This allows us in particular to estimate spectral types and determine accurate photometric redshifts for galaxies along the lines of sight to the first ten clusters for which all the required data are available down to a limit of I{sub AB} = 24./24.5 with the LePhare software. The accuracy in redshift is of the order of 0.05 for the range 0.2 {le} z {le} 1.5. We verified that the technique applied to obtain photometric redshifts works well by comparing our results to with previous works. In clusters, photo-z accuracy is degraded for bright absolute magnitudes and for the latest and earliest type galaxies. The photo-z accuracy also only slightly varies as a function of the spectral type for field galaxies. As a consequence, we find evidence for an environmental dependence of the photo-z accuracy, interpreted as the standard used Spectral Energy Distributions being not very well suited to cluster galaxies. Finally, we modeled the LCDCS 0504 mass with the strong arcs detected along this line of sight.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulation-based Performance Evaluation of Model Predictive Control for Building Energy Systems

The performance of model predictive control (MPC) can be significantly affected by different choices of controller parameters such as the time intervals for model discretization and control sampling. Due to the lack of a systematic understanding on how these parameters affect control performance, they are usually selected arbitrarily in practice.In this paper, the combined impacts of selected time intervals for model discretization and control sampling on the performance of MPC are comprehensively investigated for the first time through detailed simulations. Specifically, a typical MPC strategy is first designed to improve building operations based on a reduced-order model of building dynamics. Then, the performance of the designed MPC is evaluated against different choices of time intervals for model discretization and control sampling on a simulated office building. The detailed simulation results reveal that the time interval for model discretization has a much greater influence on the performance of MPC than the time interval for control sampling. Although the time interval for control sampling usually receives more attentions in practice, it turns out that the time interval for model discretization affects the prediction performance, cost saving, and computation time simultaneously and more significantly. Therefore, the simulation-based performance evaluation presented here sheds light on the impacts of different time intervals and facilitates their selection for practical applications of MPC to building operations

Huang, Sen↗

Determination of prospective displacement-based gate threshold for respiratory-gated radiation delivery from retrospective phase-based gate threshold selected at 4D CT simulation

Four-dimensional (4D) computed tomography (CT) imaging has found increasing importance in the localization of tumor and surrounding normal structures throughout the respiratory cycle. Based on such tumor motion information, it is possible to identify the appropriate phase interval for respiratory gated treatment planning and delivery. Such a gating phase interval is determined retrospectively based on tumor motion from internal tumor displacement. However, respiratory-gated treatment is delivered prospectively based on motion determined predominantly from an external monitor. Therefore, the simulation gate threshold determined from the retrospective phase interval selected for gating at 4D CT simulation may not correspond to the delivery gate threshold that is determined from the prospective external monitor displacement at treatment delivery. The purpose of the present work is to establish a relationship between the thresholds for respiratory gating determined at CT simulation and treatment delivery, respectively. One hundred fifty external respiratory motion traces, from 90 patients, with and without audio-visual biofeedback, are analyzed. Two respiratory phase intervals, 40%-60% and 30%-70%, are chosen for respiratory gating from the 4D CT-derived tumor motion trajectory. From residual tumor displacements within each such gating phase interval, a simulation gate threshold is defined based on (a) the average and (b) the maximum respiratory displacement within the phase interval. The duty cycle for prospective gated delivery is estimated from the proportion of external monitor displacement data points within both the selected phase interval and the simulation gate threshold. The delivery gate threshold is then determined iteratively to match the above determined duty cycle. The magnitude of the difference between such gate thresholds determined at simulation and treatment delivery is quantified in each case. Phantom motion tests yielded coincidence of simulation and delivery gate thresholds to within 0.3%. For patient data analysis, differences between simulation and delivery gate thresholds are reported as a fraction of the total respiratory motion range. For the smaller phase interval, the differences between simulation and delivery gate thresholds are 8{+-}11% and 14{+-}21% with and without audio-visual biofeedback, respectively, when the simulation gate threshold is determined based on the mean respiratory displacement within the 40%-60% gating phase interval. For the longer phase interval, corresponding differences are 4{+-}7% and 8{+-}15% with and without audio-visual biofeedback, respectively. Alternatively, when the simulation gate threshold is determined based on the maximum average respiratory displacement within the gating phase interval, greater differences between simulation and delivery gate thresholds are observed. A relationship between retrospective simulation gate threshold and prospective delivery gate threshold for respiratory gating is established and validated for regular and nonregular respiratory motion. Using this relationship, the delivery gate threshold can be reliably estimated at the time of 4D CT simulation, thereby improving the accuracy and efficiency of respiratory-gated radiation delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Completion Effects on Diagnosing Multistage Facture Treatments with Distributed Temperature Sensing

Summary Distributed temperature sensing (DTS) is a valuable tool to diagnose multistage hydraulic fracture treatments. When a stage interval is shut in, the clusters that take more fluid during pumping warm up more slowly. Therefore, the fluid volume injected into each cluster can be quantitatively interpreted by numerical inversion of the warm-back temperature behavior. This general concept assumes that the different warm-back behavior is controlled by only the injected fluid volume; however, recent observations of DTS data indicate that completion configurations significantly influence the warm-back behavior. This paper investigates the completion effects on the DTS interpretation. In ideal conditions, when a stage is fractured, the upstream stage intervals should show an almost uniform temperature that is close to the injected fluid temperature. This is due to the high fluid velocity of injected fluid in the wellbore, and the upstream intervals have not been perforated (noncommunicating intervals), so the only heat transfer is heat conduction between the wellbore fluid and the surrounding reservoir. But the field DTS data show considerably irregular variations in temperature along the upstream stage intervals. These variations are caused by the completion effects. The nonuniform temperature profile is caused by different heat transfer behavior induced by completion hardware along the production casing string, such as joints, clamps, and blast protectors, and by the sensing cable location in the cement, as well as the cement quality. Because the varying heat transfer behavior impacts the warm-back behavior as well as the temperature profile, the completion effects need to be considered in DTS interpretation. A method of DTS interpretation considering the completion effects to diagnose multistage fracture treatments was developed. Because the heat transfer between a wellbore and a reservoir depends on the overall heat transfer coefficient describing heat conduction through the completion in a forward model, this parameter needs to be tuned all along the wellbore. To calibrate the completion effect, the temperature inversion is conducted using the temperature measured at a stage interval that is upstream of a stage interval currently being treated. Because the interpreted stage interval is not perforated at that time, the thermal behavior at the noncommunicating interval is governed by only the heat conduction through the completion environment. Once the effective values of the overall heat transfer coefficient are estimated along the interpreted stage interval, they can be assumed to be constant physical parameters. Then, the fluid volume distribution is interpreted by using the effective overall heat transfer coefficient profile along each interval. This study provides a field application of the developed interpretation method. The new interpretation method provides more accurate diagnosis of fracture treatments by DTS interpretation.

Engineering↗

Diagnostic assessment of reservoir response to fracturing: a case study from Hydraulic Fracturing Test Site (HFTS) in Midland Basin

Abstract This paper outlines a data collection and diagnostics case study involving multiple horizontal shale wells. We look at well production profiles using rate transient analysis, differences in near wellbore complexity, geologic variations within the area of interest, as well as compositional differences in the rocks based on cores obtained from within the stimulated reservoir. The Hydraulic Fracturing Test Site is a multi-well experiment involving stimulation of unconventional shale wells in the southeastern Midland portion of the Permian Basin. The targeted formations include both the upper as well as the middle Wolfcamp formations, also referred alternatively as Wolfcamp A and Wolfcamp B. Data integration and analysis shared in this paper help us understand the various geologic controls impacting well productivity, particularly the wide variance observed between the Wolfcamp A and Wolfcamp B formations. Rate transient analysis indicates similar system permeabilities for stimulated wells. However, we observe higher effective fracture half-lengths for upper Wolfcamp wells. Using observations from 3D seismic interpretations (such as pad scale faults) as well as petrophysical and image log data, we highlight the substantial differences in stimulation as we move along the well laterals from the heel toward the toe sections. These differences are further reconciled with observations from zones with high data density at the core locations through stimulated rock, as well as independent data such as microseismic emissions. At the test site, Wolfcamp A was found to be relatively quartz rich with significant heterogeneity whereas Wolfcamp B is richer in clay and organic content. This impacts the geomechanical characteristics of the rock mass with much higher natural fracture density in the shallower interval. Thus, the fracture growth is more uniform in the deeper interval and more heterogeneous with branching likely in upper interval. Increased complexity also leads to consistently better productivity from the wells in the shallower interval as demonstrated from RTA results. This case study is unique because it provides valuable insights from actual sampling of the stimulated zones in hydraulically fractured wells and helps understand impact of various factors that contribute toward variability in well production. The findings from this study provides insights into need for optimization of completion designs in the various Wolfcamp landing zones, such as optimization of cluster or fracture spacing in various Wolfcamp intervals. In addition, it provides a useful template for data collection and research direction in future field test sites of similar nature in unconventional reservoirs.

Energy & Fuels↗

Waste management under multiple complexities: Inexact piecewise-linearization-based fuzzy flexible programming

Highlights: Black-Right-Pointing-Pointer Inexact piecewise-linearization-based fuzzy flexible programming is proposed. Black-Right-Pointing-Pointer It's the first application to waste management under multiple complexities. Black-Right-Pointing-Pointer It tackles nonlinear economies-of-scale effects in interval-parameter constraints. Black-Right-Pointing-Pointer It estimates costs more accurately than the linear-regression-based model. Black-Right-Pointing-Pointer Uncertainties are decreased and more satisfactory interval solutions are obtained. - Abstract: To tackle nonlinear economies-of-scale (EOS) effects in interval-parameter constraints for a representative waste management problem, an inexact piecewise-linearization-based fuzzy flexible programming (IPFP) model is developed. In IPFP, interval parameters for waste amounts and transportation/operation costs can be quantified; aspiration levels for net system costs, as well as tolerance intervals for both capacities of waste treatment facilities and waste generation rates can be reflected; and the nonlinear EOS effects transformed from objective function to constraints can be approximated. An interactive algorithm is proposed for solving the IPFP model, which in nature is an interval-parameter mixed-integer quadratically constrained programming model. To demonstrate the IPFP's advantages, two alternative models are developed to compare their performances. One is a conventional linear-regression-based inexact fuzzy programming model (IPFP2) and the other is an IPFP model with all right-hand-sides of fussy constraints being the corresponding interval numbers (IPFP3). The comparison results between IPFP and IPFP2 indicate that the optimized waste amounts would have the similar patterns in both models. However, when dealing with EOS effects in constraints, the IPFP2 may underestimate the net system costs while the IPFP can estimate the costs more accurately. The comparison results between IPFP and IPFP3 indicate that their solutions would be significantly different. The decreased system uncertainties in IPFP's solutions demonstrate its effectiveness for providing more satisfactory interval solutions than IPFP3. Following its first application to waste management, the IPFP can be potentially applied to other environmental problems under multiple complexities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AN OPTICAL-NEAR-INFRARED OUTBURST WITH NO ACCOMPANYING {gamma}-RAYS IN THE BLAZAR PKS 0208-512

We report the discovery of an anomalous flare in a bright blazar, namely, PKS 0208-512, one of the targets of the Yale/SMARTS optical-near-IR (OIR) monitoring program of Fermi blazars. We identify three intervals during which PKS 0208-512 undergoes outbursts at OIR wavelengths lasting for {approx}>3 months. Its brightness increases and then decreases again by at least 1 mag in these intervals. In contrast, the source undergoes bright phases in GeV energies lasting {approx}>1 month during intervals 1 and 3 only. The OIR outburst during interval 2 is comparable in brightness and temporal extent to the OIR flares during intervals 1 and 3, which do have {gamma}-ray counterparts. By analyzing the {gamma}-ray, OIR, and supporting multi-wavelength variability data in details, we speculate that the OIR outburst during interval 2 was caused by a change in the magnetic field without any change in the total number of emitting electrons or Doppler factor of the emitting region. Alternatively, it is possible that the location of the outburst in the jet during interval 2 was closer to the black hole where the jet is more compact and the bulk Lorentz factor of the material in the jet is smaller. We also discuss the complex OIR spectral behavior during these three intervals.

79 ASTRONOMY AND ASTROPHYSICS↗

Timing of Radiotherapy and Outcome in Patients Receiving Adjuvant Endocrine Therapy

Purpose: To evaluate the association between the interval from breast-conserving surgery (BCS) to radiotherapy (RT) and the clinical outcome among patients treated with adjuvant endocrine therapy. Patients and Methods: Patient information was obtained from three International Breast Cancer Study Group trials. The analysis was restricted to 964 patients treated with BCS and adjuvant endocrine therapy. The patients were divided into two groups according to the median number of days between BCS and RT and into four groups according to the quartile of time between BCS and RT. The endpoints were the interval to local recurrence, disease-free survival, and overall survival. Proportional hazards regression analysis was used to perform comparisons after adjustment for baseline factors. Results: The median interval between BCS and RT was 77 days. RT timing was significantly associated with age, menopausal status, and estrogen receptor status. After adjustment for these factors, no significant effect of a RT delay {<=}20 weeks was found. The adjusted hazard ratio for RT within 77 days vs. after 77 days was 0.94 (95% confidence interval [CI], 0.47-1.87) for the interval to local recurrence, 1.05 (95% CI, 0.82-1.34) for disease-free survival, and 1.07 (95% CI, 0.77-1.49) for overall survival. For the interval to local recurrence the adjusted hazard ratio for {<=}48, 49-77, and 78-112 days was 0.90 (95% CI, 0.34-2.37), 0.86 (95% CI, 0.33-2.25), and 0.89 (95% CI, 0.33-2.41), respectively, relative to {>=}113 days. Conclusion: A RT delay of {<=}20 weeks was significantly associated with baseline factors such as age, menopausal status, and estrogen-receptor status. After adjustment for these factors, the timing of RT was not significantly associated with the interval to local recurrence, disease-free survival, or overall survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reconstructing paleo-SMT positions on the Casadia margin using magnetic susceptibility

Magnetic susceptibility (κ) is a mixed signal in marine sediments, representing primary depositional and secondary diagenetic processes. Production of hydrogen sulfide via anaerobic oxidation of methane (AOM) at the sulfate-methane transition (SMT) and organoclastic sulfate reduction above the SMT can result in the dissolution of iron oxides, altering κ in sediments in methane gas and gas hydrate bearing regions. We investigated records of κ on the Cascadia margin (ODP Sites 1249 and 1252; IODP Site 1325) using a Zr/Rb heavy mineral proxy from XRF core scanning to identify intervals of primary detrital magnetic susceptibility and intervals and predict intervals affected by magnetite dissolutions. We also measured total sulfur content, grain size distributions, total organic carbon (TOC) content, and magnetic mineral assemblage. The upper 100 m of Site 1252 contains a short interval of κ driven by primary magnetite, with multiple intervals (> 90 m total) of decreased κ correlated with elevated sulfur content, consistent with dissolution of magnetite and re-precipitation of pyrite. In the upper 90 m of Site 1249, κ is almost entirely altered by diagenetic processes, with much of the low κ explained by a high degree of pyritization, and some intervals affected by the precipitation of magnetic iron sulfides. At Site 1325, κ between 0-20 and 51-73 mbsf represents primary mineralogy, and in the interval 24-51 mbsf, κ may be reduced due to pyritization. This integrated approach allows for a prediction of primary κ and the amount of κ loss at each site when compared to actual κ measurements. In the case of magnetite dissolution and full pyritization, these drawdowns in κ are supported by sulfur measurements, and the exposure times of magnetite to hydrogen sulfide can be modeled. The presence of methane and methane hydrates at these sites, as well as large variations in TOC content, suggest that the past migration rates of the SMT and variation in sulfate reduction rates may influence κ alteration along the Cascadia margin.

03 NATURAL GAS↗

Data from: Comparing traditional and Bayesian approaches to ecological meta-analysis

Despite the wide application of meta-analysis in ecology, some of the traditional methods used for meta-analysis may not perform well given the type of data characteristic of ecological meta-analyses. We reviewed published meta-analyses on the ecological impacts of global climate change, evaluating the number of replicates used in the primary studies (ni) and the number of studies or records (k) that were aggregated to calculate a mean effect size. We used the results of the review in a simulation experiment to assess the performance of conventional frequentist and Bayesian meta-analysis methods for estimating a mean effect size and its uncertainty interval. Our literature review showed that ni and k were highly variable, distributions were right-skewed, and were generally small (median ni =5, median k=44). Our simulations show that the choice of method for calculating uncertainty intervals was critical for obtaining appropriate coverage (close to the nominal value of 0.95). When k was low (<40), 95% coverage was achieved by a confidence interval based on the t-distribution that uses an adjusted standard error (the Hartung-Knapp-Sidik-Jonkman, HKSJ), or by a Bayesian credible interval, whereas bootstrap or z-distribution confidence intervals had lower coverage. Despite the importance of the method to calculate the uncertainty interval, 39% of the meta-analyses reviewed did not report the method used, and of the 61% that did, 94% used a potentially problematic method, which may be a consequence of software defaults. In general, for a simple random-effects meta-analysis, the performance of the best frequentist and Bayesian methods were similar for the same combinations of factors (k and mean replication), though the Bayesian approaches had higher than nominal (>95%) coverage for the mean effect when k was very low (k<15). Our literature review suggests that many meta-analyses that used z-distribution or bootstrapping confidence intervals may have over-estimated the statistical significance of their results when the number of studies was low; more appropriate methods need to be adopted in ecological meta-analyses.

54 ENVIRONMENTAL SCIENCES↗

Transmitter with fully re-assignable segments for reconfigurable FFE taps

Methods and systems of performing feed forward equalization (FFE) on data streams are described. A circuitry may generate staggered data streams from data streams of an input signal. The staggered data streams may include data in staggered unit intervals. The circuitry may include a plurality of segments. A segment may define a specific unit interval to carve the staggered data streams into one unit interval pulses positioned at the specific unit interval. The specific unit interval to carve the staggered data streams may indicate an assignment of the segment as one of a FFE pre tap, a FFE main tap, and a FFE post tap. The plurality of segments may be assigned to different FFE taps based on different clock signal selection defining different unit intervals to perform the carving. The plurality of segments may output respective one unit interval pulses to reproduce the input signal.

Toprak-Deniz, Zeynep↗

Multispectral impedance determination under dynamic load conditions

Impedance testing devices, circuits, systems, and related methods are disclosed. A Device Under Test (DUT) is excited with a multispectral excitation signal for an excitation time period while the DUT is under a load condition from a load operably coupled to the DUT. A response of the DUT is sampled over a sample time period. The sample time period is configured such that it includes an in-band interval during the excitation time period and one or more out-of-band intervals outside of the in-band interval. A response of the DUT to the load condition during the in-band interval is estimated by analyzing samples of the response from the one or more out-of-band intervals. Adjusted samples are computed by subtracting the estimated load response during the in-band interval from the samples from the in-band interval. An impedance of the DUT is estimated by analyzing the adjusted samples.

Christophersen, Jon P.↗

Transverse momentum dependence of D-meson production in Pb-Pb collisions at $ \sqrt{{\mathrm{s}}_{\mathrm{NN}}}=2.76 $ TeV

The production of prompt charmed mesons D 0 , D + and D* + , and their antiparticles, was measured with the ALICE detector in Pb-Pb collisions at the centre-of-mass energy per nucleon pair, √ s NN, of 2.76 TeV. The production yields for rapidity |y| < 0.5 are presented as a function of transverse momentum, p T , in the interval 1–36 GeV/c for the centrality class 0–10% and in the interval 1–16 GeV/c for the centrality class 30–50%. The nuclear modification factor R AA was computed using a proton-proton reference at √s = 2.76 TeV, based on measurements at √s = 7 TeV and on theoretical calculations. A maximum suppression by a factor of 5-6 with respect to binary-scaled pp yields is observed for the most central collisions at p T of about 10 GeV/c. A suppression by a factor of about 2-3 persists at the highest p T covered by the measurements. At low pT (1-3 GeV/c), the R AA has large uncertainties that span the range 0.35 (factor of about 3 suppression) to 1 (no suppression). In all p T intervals, the R AA is larger in the 30-50% centrality class compared to central collisions. Furthermore, the D-meson R AA is also compared with that of charged pions and, at large p T , charged hadrons, and with model calculations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Life History Correlates and Extinction Risk of Capital-Breeding Fishes

We consider a distinction for fishes, often made for birds and reptiles, between capital-breeding and income-breeding species. Species that follow a capital-breeding strategy tend to evolve longer intervals between reproductive events and tend to have characteristics that we associate with higher extinction risk. To examine whether these ideas are relevant for fishes, we assembled life-history data for fish species, including an index of extinction risk, the interval between spawning events, the degree of parental care, and whether or not the species migrates to spawn. These data were used to evaluate two hypotheses: 1) fish species with a major accessory activity to spawning (migration or parental care) spawn less often and 2) fish species that spawn less often are at greater risk of extinction. We tested these hypotheses by applying two alternative statistical methods that account for phylogenetic correlation in cross-taxon comparisons. The two methods predicted average intervals between spawning events 0.13 to 0.20 years longer for fishes with a major accessory activity. Both accessories, above-average parental care and spawning migration, were individually associated with longer average spawning intervals. We conclude that the capital-breeding paradigm is relevant for fishes. We also confirmed the second hypothesis, that species in higher IUCN extinction risk categories had longer average spawning intervals. Further research is needed to understand the relationship between extinction risk and spawning interval, within the broader context of life history traits and aquatic habitats.

60 APPLIED LIFE SCIENCES↗