A 50-GBaud QPSK Optical Receiver With a Phase/Frequency Detector for Energy-Efficient Intra-Data Center Interconnects
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Abstract not provided.
In this paper, we propose a novel multi-time scale emergency frequency response model by unlocking the flexibility of High Voltage Direct Current (HVDC) systems. Unlike assigning power ramping rates for FACTS to regulate frequency in traditional methods, this paper designs a step-change electromagnetic power frequency response (EPFR) scheme, by leveraging the temporal over/under DC voltage capability of HVDC. Wherein the Kullback-Leibler Divergence is adopted to convexify the modified swing equation after integrating the step-change power. Further, to avoid the complicated differential equations, we equivalently reformulate the duration limits of DC voltage deviation into the HVDC decreasing power ramping rates, which participate in the system primary frequency response. Finally, the new steady-state operation level of HVDC is involved with the secondary frequency response. As a result, an improved three-level algorithm is developed to solve the model, wherein the instant step-change, primary, and secondary frequency response are coordinated together. After applying the proposed frequency response scheme on the test system, the EPFR is validated to effectively provide the most instantaneous supports when faced with bulk power loss due to extreme contingencies, and the resilience is ensured within acceptable expenditures.
Abstract not provided.
Coplanar (with the ground) 20 cm long waveguides are manufactured from the YBCO-on-Kapton material. We investigate the effect of parasitic ground plane resonances on the performance of these waveguides. Here, it is concluded that dense rows stitching vias are essential for isolating the lines to a level below 60 dB at 6 GHz. We demonstrate a metalized via technology that is compatible with both the traditional Flexible Printed Circuit (FPC) process and the epitaxial YBCO material. Stitching via fence with the via period 10 mm is shown as effective in suppressing parasitic resonances at 77 K.
Not provided.
Not provided.
Not provided.
Combining planning models with operational details allows the industry to proactively investigate future resource and load scenarios, rather than react to their implementation in real time. In this project, the following tasks are proposed. The methodologies we developed to resolve current challenges in importing and solving the chronological AC power flow is a three-stage process.
Microbial interactions shape the structure and function of microbial communities; microbial association networks in specic environments have been widely developed to explore these complex systems, but their wired pattern across microbiomes in various environments at the global scale remains unexplored. Here we have inferred an Earth microbial association network from a communal catalogue with 23,595 samples and 12,646 exact sequence variants from 14 environments in the Earth Microbiome Project dataset. Results: This non-random scale-free Earth microbial association network consisted of 8 taxonomy distinct modules linked with dierent environments, which featured environment specic microbial associations. Dierent topological features of subnetworks inferred from datasets trimmed into uniform size indicate distinct association patterns in the microbiomes of various environments. The proportions of specialist edges, which ranged from 43.0% to 65.7%, highlight that environmental specic microbial associations are essential features of microbiomes in various environments. Based on edge-overlap similarity, the microbiomes of various environments were clustered into two groups, which were mainly bridged by the microbiomes of plant and animal surface. Acidobacteria Gp2 and Nisaea were identied as hubs in most of subnetworks. Negative edges proportions ranged from 1.9% in the soil subnetwork to 48.9% the non-saline surface subnetwork, suggesting various environments experience distinct intensities of competition or niche dierentiation. Conclusion: This investigation provides a new resource for examining Earth microbial association patterns across environments and emphasizes the network perspective for comprehensively understanding unique microbiome features. Keywords: Association pattern; Earth microbiomes; Genelist edges; Network hubs; Negative associations; Specialist edges; Topological properties
The main goal of this project was to follow up on prior discovery of the communal nature of methane utilization by the aerobic methanotrophic bacteria, resulting in carbon transfer along a food chain. This goal was approached via manipulation of specially designed, synthetic bacterial communities, fed exclusively by methane, under a variety of simulated environmental conditions. Using (meta)genomics, metatranscriptomics, stable isotope probing and mutant generation, we obtained solid evidence for the nature of the core microbiota involved in collaborative methane consumption, the major players (true methanotrophs) being the members of the family Methylococcaceae, their major partners (non-methanotrophic methylotrophs) being members of the family Methylophilaceae, and minor but persistent partners in the communities being members of the orders Burkholderiales and Bacteroidetes. Metabolic reconstruction from single genomes and metagenome-assembled genomes (MAGs), along with metatranscriptomics results delineated major pathways for carbon metabolism, suggesting that the methanotrophs share different organic compounds with different functional guilds: methanol with Methylophilaceae, acetate with Burkholderiales, and polymeric substances with Bacteroidetes. Overall, the results of this project expand our understanding of microbial metabolism of methane and, thus, provide basis for strategies for microbial methane mitigation, with obvious benefits to the society of the United States and worldwide.
This project’s objective is to develop a combined transmission and distribution state estimator which accounts for very large system size and model complexity (by way of distributing the computations) and large number of solar PV units connected to the distribution system on multiple feeders. The project not only provides a robust formulation and solution to this problem but also tests the solution by implementing it on a well-established large utility system. It introduces several improvements with respect to the state of the art in existing state estimation software: (a) The developed state estimator (SE) allows robust and accurate monitoring of bidirectional flows in distribution systems which result due to the distributed energy sources which are not observable and thus not incorporated in generation dispatch; (b) Large utility systems with tens of thousands of transmission buses and hundreds of thousands of distribution nodes are difficult to model as a single integrated system. This shortcoming is addressed by developing a “scalable distributed computational framework” which allows splitting the ultra large system models into several small subsystems and coordinating their solution by a robust and practical state estimation formulation; (c) Measurement errors irrespective of their locations are detected and removed by the developed state estimator. Historically, transmission and distribution systems were analyzed and operated as two independent systems. Given the non-transposed short feeder sections, unevenly loaded phases, strictly radial configuration and unidirectional power flows in the absence of remote generation, distribution system analysis was customized to account for these characteristics. However, some of these assumptions are no longer valid (non-radial configuration, bidirectional power flows) and thus distribution system analysis should be revisited. Furthermore, in the past, the interaction between the transmission and distribution systems was quite passive, where distribution substations were modeled as lumped loads in the transmission system model. With substantial generation injected by renewable generation located in the distribution systems, such modeling will no longer be accurate. The developed state estimator facilitates proper monitoring of the interactions between the transmission and distribution systems and enables smart dispatch of these units which are made observable by the state estimator.
The ground fault overvoltage (GFOV) and the required traditional 3V0 installation has become a concerned issue for renewable/DER integration. Based on the alternative 3V0 methodology proposed by the PI and the feasibility study awarded by DOE SBIR/STIR project (Award No. DE-SC0018888), APS and RPI investigated development of a low-cost alternative 3V0 product based on the surge arrester current monitoring. The alternative 3V0 feasibility study completed by APS and RPI has verified that the alternative 3V0 is an effective solution (possibly the only one) under various circuit conditions and is competitive to traditional 3V0 methods.
Escalating deployment of PV and grid-edge devices on the distribution grid has increased the sustainability and efficiency of the electric grid. However, the increasing number of distributed energy resources (DERs) deployed creates a heightened cyber-physical interdependency on the distribution grid and thus creates more vectors for cyber-attacks to exploit through information and communication technology (ICT) systems and networks. For example, control signal packets can be modified, intercepted, or corrupted due to vulnerabilities in communication protocols used by microgrid controllers and grid edge devices for power control. Therefore, to mitigate and prevent cyber-attacks on grid edge devices and the inverter-based resources connected to the distribution grid, the U.S. Department of Solar Energy Technologies Office (SETO) awarded funding to the National Renewable Energy Laboratory and Sandia National Laboratory (SNL) to research, develop, and harmonize cybersecurity standards for Photovoltaic (PV) systems and for other kinds of DERs. To help develop a standard for DER cybersecurity, NREL established certification recommendations and test cases, in consensus with the solar industry and UL, for ensuring intrinsic design security for DERs. These recommendations were developed to bolster the cybersecure functionalities such as TLS, MAC, CRL, session resumption/renegotiation, and password, system, and service security management within the DER devices. The proposed test cases verify authentication, authorization, confidentiality, and data integrity for data and communications of DERs that use Transmission Control Protocol/Internet Protocol (TCP/IP). They were also developed to protect DER communications from eavesdropping, replay, man-in-the-middle, denial of service (DoS), spoofing through security certificates, least-privilege violation, and brute-force credentials. This report, which has been validated and reviewed by UL, expands upon those test cases to provide DER cybersecurity certification recommendations which increase DER resiliency and help to mitigate cyber-attacks. UL's collaboration with NREL and approval of this document will accelerate the adoption of a UL standard for DER cybersecurity.
Abstract not provided.
Abstract not provided.
Abstract not provided.