Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interchangeable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Structure analysis of aluminium silicon manganese nitride precipitates formed in grain-oriented electrical steels

We report a detailed structural and chemical characterisation of aluminium silicon manganese nitrides that act as grain growth inhibitors in industrially processed grain-oriented (GO) electrical steels. The compounds are characterised using energy dispersive X-ray spectrometry (EDX) and energy filtered transmission electron microscopy (EFTEM), while their crystal structures are analysed using X-ray diffraction (XRD) and TEM in electron diffraction (ED), dark-field, high-resolution and automated crystallographic orientation mapping (ACOM) modes. The chemical bonding character is determined using electron energy loss spectroscopy (EELS). Despite the wide variation in composition, all the precipitates exhibit a hexagonal close-packed (h.c.p.) crystal structure and lattice parameters of aluminium nitride. The EDX measurement of ∼ 900 stoichiometrically different precipitates indicates intermediate structures between pure aluminium nitride and pure silicon manganese nitride, with a constant Si/Mn atomic ratio of ∼ 4. It is demonstrated that aluminium and silicon are interchangeably precipitated with the same local arrangement, while both Mn{sup 2+} and Mn{sup 3+} are incorporated in the h.c.p. silicon nitride interstitial sites. The oxidation of the silicon manganese nitrides most likely originates from the incorporation of oxygen during the decarburisation annealing process, thus creating extended planar defects such as stacking faults and inversion domain boundaries. The chemical composition of the inhibitors may be written as (AlN){sub x}(SiMn{sub 0.25}N{sub y}O{sub z}){sub 1−x} with x ranging from 0 to 1. - Highlights: • We study the structure of (Al,Si,Mn)N inhibitors in grain oriented electrical steels. • Inhibitors have the hexagonal close-packed symmetry with lattice parameters of AlN. • Inhibitors are intermediate structures between pure AlN and (Si,Mn)N with Si/Mn ∼ 4. • Al and Si share the same local arrangement; Mn is incorporated in both Mn{sup 2+} and Mn{sup 3+}. • Oxygen incorporation is invoked to account for the thermal stability of (Al,Si,Mn)N.

36 MATERIALS SCIENCE↗

Electron backscatter diffraction study of deformation and recrystallization textures of individual phases in a cross-rolled duplex steel

The evolution of microstructure and texture during cross-rolling and annealing was investigated by electron backscatter diffraction in a ferritic–austenitic duplex stainless steel. For this purpose an alloy with nearly equal volume fraction of the two phases was deformed by multi-pass cross-rolling process up to 90% reduction in thickness. The rolling and transverse directions were mutually interchanged in each pass by rotating the sample by 90° around the normal direction. In order to avoid deformation induced phase transformation and dynamic strain aging, the rolling was carried out at an optimized temperature of 898 K (625 °C) at the warm-deformation range. The microstructure after cross warm-rolling revealed a lamellar structure with alternate arrangement of the bands of two phases. Strong brass and rotated brass components were observed in austenite in the steel after processing by cross warm-rolling. The ferrite in the cross warm-rolling processed steel showed remarkably strong RD-fiber (RD//< 011 >) component (001)< 011 >. The development of texture in the two phases after processing by cross warm-rolling could be explained by the stability of the texture components. During isothermal annealing of the 90% cross warm-rolling processed material the lamellar morphology was retained before collapse of the lamellar structure to the mutual interpenetration of the phase bands. Ferrite showed recovery resulting in annealing texture similar to the deformation texture. In contrast, the austenite showed primary recrystallization without preferential orientation selection leading to the retention of deformation texture. The evolution of deformation and annealing texture in the two phases of the steel was independent of one another. - Highlights: • Effect of cross warm-rolling on texture formation is studied in duplex steel. • Brass texture in austenite and (001)<110 > in ferrite are developed. • Ferrite shows recovery during annealing retaining the (001)<110 > component. • Austenite shows recrystallization during annealing retaining the deformation texture. • The deformation of recrystallization of two phases is independent of one other.

36 MATERIALS SCIENCE↗

Dosimetric Comparison of Tandem and Ovoids vs. Tandem and Ring for Intracavitary Gynecologic Applications

We evaluated dosimetric differences in tandem and ovoid (TO) and tandem and ring (TR) gynecologic brachytherapy applicators. Seventeen patients with cervical cancer (Stages II-IV) receiving 3 high-dose-rate (HDR) brachytherapy applications (both TO and TR) were studied. Patients underwent computed tomography (CT) scans with contrast in bladder, and were prescribed 8 Gy to ICRU points A, with additional optimization goals of maintaining the pear-shaped dose distribution and minimizing bladder and rectum doses. Bladder and rectum point doses, mean, and maximum doses were calculated. Total treatment time and volumes treated to 95%, 85%, 50%, and 20% or the prescription dose were compared. There were no significant differences between TO and TR applicators in doses to prescription points or critical organs. However, there were significant differences (p < 0.001) between the applicators in treated volumes and total treatment time. The TO treated larger volumes over a longer time. Within each patient, when the applicators were compared, treated volumes were also found to be significantly different (p < 0.01, {chi}{sup 2}). Our results demonstrate that the 2 applicators, while delivering the prescribed dose to points A and keeping critical organ doses below tolerance, treat significantly different volumes. It is unclear if this difference is clinically meaningful. TO applicators may be treating surrounding healthy tissue unnecessarily, or TR applicators may be underdosing tumor tissue. Further investigation with appropriate imaging modalities is required for accurate delineation of target volumes. Clearly, the TO and TR are not identical, and should not be used interchangeably without further study.

61 RADIATION PROTECTION AND DOSIMETRY↗

A patient-specific quality assurance study on absolute dose verification using ionization chambers of different volumes in RapidArc treatments

The recalculation of 1 fraction from a patient treatment plan on a phantom and subsequent measurements have become the norms for measurement-based verification, which combines the quality assurance recommendations that deal with the treatment planning system and the beam delivery system. This type of evaluation has prompted attention to measurement equipment and techniques. Ionization chambers are considered the gold standard because of their precision, availability, and relative ease of use. This study evaluates and compares 5 different ionization chambers: phantom combinations for verification in routine patient-specific quality assurance of RapidArc treatments. Fifteen different RapidArc plans conforming to the clinical standards were selected for the study. Verification plans were then created for each treatment plan with different chamber-phantom combinations scanned by computed tomography. This includes Medtec intensity modulated radiation therapy (IMRT) phantom with micro-ionization chamber (0.007 cm{sup 3}) and pinpoint chamber (0.015 cm{sup 3}), PTW-Octavius phantom with semiflex chamber (0.125 cm{sup 3}) and 2D array (0.125 cm{sup 3}), and indigenously made Circular wax phantom with 0.6 cm{sup 3} chamber. The measured isocenter absolute dose was compared with the treatment planning system (TPS) plan. The micro-ionization chamber shows more deviations when compared with semiflex and 0.6 cm{sup 3} with a maximum variation of -4.76%, -1.49%, and 2.23% for micro-ionization, semiflex, and farmer chambers, respectively. The positive variations indicate that the chamber with larger volume overestimates. Farmer chamber shows higher deviation when compared with 0.125 cm{sup 3}. In general the deviation was found to be <1% with the semiflex and farmer chambers. A maximum variation of 2% was observed for the 0.007 cm{sup 3} ionization chamber, except in a few cases. Pinpoint chamber underestimates the calculated isocenter dose by a maximum of 4.8%. Absolute dose measurements using the semiflex ionization chamber with intermediate volume (0.125 cm{sup 3}) shows good agreement with the TPS calculated among the detectors used in this study. Positioning is very important when using smaller volume chambers because they are more sensitive to geometrical errors within the treatment fields. It is also suggested to average the dose over the sensitive volume for larger-volume chambers. The ionization chamber-phantom combinations used in this study can be used interchangeably for routine RapidArc patient-specific quality assurance with a satisfactory accuracy for clinical practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

Focusing neutron guides for VULCAN ' Design Aspects, Estimated Performance, and Detector Deployment

The neutron optics design and performance for VULCAN ' the SNS Engineering Diffractometer ' is presented. A gradually tapered focusing neutron guide is used to deliver desired beam divergence at sample position. Selection of instrument resolution is achieved with an interchangeable guide-collimator system in the last 3-m of the neutron guide system. The effect of focusing on instrument resolution was evaluated and the strategy for detector deployment is discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A compact ultra-clean system for deploying radioactive sources inside the KamLAND detector

We describe a compact, ultra-clean device used to deploy radioactive sources along the vertical axis of the KamLAND liquid-scintillator neutrino detector for purposes of calibration. The device worked by paying out and reeling in precise lengths of a hanging, small-gauge wire rope (cable); an assortment of interchangeable radioactive sources could be attached to a weight at the end of the cable. All components exposed to the radiopure liquid scintillator were made of chemically compatible UHV-cleaned materials, primarily stainless steel, in order to avoid contaminating or degrading the scintillator. To prevent radon intrusion, the apparatus was enclosed in a hermetically sealed housing inside a glove box, and both volumes were regularly flushed with purified nitrogen gas. Finally, an infrared camera attached to the side of the housing permitted real-time visual monitoring of the cable’s motion, and the system was controlled via a graphical user interface.

42 ENGINEERING↗

Using the JCC-71 neutron coincidence collar as a benchmark for detector characterization with PTR-32 list mode data acquisition

Augmenting or interchanging current international safeguards shift registerbased data acquisition systems with list mode data acquisition systems gives nondestructive assay (NDA) systems greater versatility. Neutron list mode data analysis offers comparable analytical results to the more widely used shift register analysis in nuclear material quantification applications and offers several diagnostic tools that are specifically beneficial to in-laboratory characterization and calibration measurements. These benefits include identification of non-ideal behavior, optimization of operational parameters from a single measurement, and an improved understanding of the physics-based behavior of NDA systems for a more precise system representation and more confident assay results. In this work the advantages of using list mode data acquisition for detector characterization are demonstrated experimentally. Two commercial-off-the-shelf International Atomic Energy Agency-supported technologies are used for a typical detector characterization procedure and their performance is compared. Specifically, a 3 He-based Canberra Industries JCC-71 Neutron Coincidence Collar is characterized using the Hungarian Institute of Isotopes’ Pulse Train Recorder-32 (PTR-32) list mode data acquisition system, and the results are compared to those obtained using the standard Canberra Industries JSR-15 model shift register. The quantitative results from the two systems are in agreement, which demonstrates that the PTR-32 is a technically viable alternative to conventional shift register electronics for this task. A suitable procedure for full instrument characterization is described, and the added benefits of list mode for characterization and data collection are discussed. Furthermore, this is an important step toward establishing a procedure for the routine use of list mode data acquisition and analysis for neutron NDA system characterization in safeguards field applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single channel PICOSEC Micromegas detector with improved time resolution

This paper presents design guidelines and the experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving the stability, reducing noise, and ensuring signal integrity to optimize timing performance. A notable feature is the simple and fast reassembly procedure, facilitating quick replacement of the detector internal components that allows for an efficient measurement strategy involving different detector components. The paper also examines the influence of parasitic capacitance and inductance on the output signal integrity. To validate the design, a prototype assembly and three interchangeable detector boards with varying readout pad diameters were manufactured. Detectors were initially tested in the laboratory. Finally, the timing performance of the detectors with different pad sizes was verified using 150 GeV muons. Notably, a record time resolution for a PICOSEC Micromegas detector technology with a CsI photocathode of 12.5 ± 0.8 ps was achieved for a detector with 10 mm diameter readout pad size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Update on the MiniCLEAN dark matter experiment

The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of order 50 to 100 tonnes. The liquid cryogen is interchangeable between argon and neon to study the A² dependence of the potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular design with spherical geometry to maximize the light yield using cold photomultiplier tubes in a single-phase detector. Pulse shape discrimination techniques are used to separate nuclear recoil signals from electron recoil backgrounds. MiniCLEAN will be spiked with additional ³⁹Ar to demonstrate the effective reach of the pulse shape discrimination capability. Assembly of the experiment is underway at SNOLAB and an update on the project is given.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Benchmarking state-of-the-art theory and empirical models of pionless neutrino-argon scattering in GENIE

Upcoming experiments need improved simulations of neutrino scattering. This work uses the popular GENIE event generator to test a variety of neutrino interaction models against recent MicroBooNE measurements of pionless charged-current interactions. The GENIE code can easily interchange model components, including nucleon form factor parameterizations, quasielastic cross-section calculations, treatments of the nuclear ground state and hadronic final-state interactions. Leveraging this software capability in comparisons with MicroBooNE data, the performance of some of GENIE’s most theoretically sophisticated model components is evaluated and contrasted with more empirically-driven alternatives.

Neutrino cross section↗

Influenza B virus M2 protein can functionally replace its influenza A virus counterpart in promoting virus replication

The M2 protein (AM2 and BM2) of influenza A and B viruses function as a proton channel essential for viral replication. They also carry a cytoplasmic tail whose functions are not fully delineated. It is currently unknown whether these proteins could be replaced functionally in a viral context. Here, we generated single-cycle influenza A viruses (scIAV-ΔHA) carrying various M2-2A-mCherry constructs in the segment 4 (HA) and evaluated their growth in complementing cells. Intriguingly, the scIAV-ΔHA carrying AM2 and that bearing BM2 grew comparably well in MDCK-HA cells. Furthermore, while the virus carrying chimeric B-AM2 in which the BM2 transmembrane fused with the AM2 cytoplasmic tail produced robust infection, the one bearing the AM2 transmembrane fused with the BM2 cytoplasmic tail (A-BM2) exhibited severely impaired growth. Altogether, we demonstrate that AM2 and BM2 are functionally interchangeable and underscore the role of compatibility between transmembrane and cytoplasmic tail of the M2 protein. -- Highlights: •Flu A M2 protein (AM2) can be functionally replaced by that of Flu B (BM2). •Both AM2 and BM2 with extended cytoplasmic tail are functional. •Compatibility between the ion channel and the cytoplasmic tail is critical for M2 function. •M2 with higher ion channel activity may augment influenza virus replication.

60 APPLIED LIFE SCIENCES↗

Nucleolin is expressed in patient-derived samples and glioblastoma cells, enabling improved intracellular drug delivery and cytotoxicity

Highlights: • Nucleolin is overexpressed in GSC sub-populations and non-stem glioblastoma cells; • Nucleolin enables intracellular targeted drug delivery in glioblastoma cells; • Nucleolin is overexpressed in glioblastoma patient-derived samples. One of the major challenges in Glioblastoma (GBM) therapy relates with the existence of glioma stem-like cells (GSCs), known to be chemo- and radio-resistant. GSCs and non-stem GBM cells have the ability to interchange, emphasizing the importance of identifying common molecular targets among those cell sub-populations. Nucleolin overexpression has been recently associated with breast cancer sub-populations with different stem-like phenotype. The goal of this work was to evaluate the potential of cell surface nucleolin as a target in GBM cells. Different levels of nucleolin expression resulted in a 3.4-fold higher association of liposomes targeting nucleolin (functionalized with the nucleolin-binding F3 peptide) in U87, relative to GBM11 glioblastoma cells. Moreover, nucleolin was suggested as a potential marker in OCT4-, NANOG-positive GSC, and in the corresponding non-stem GBM cells, as well as in SOX2-positive GSC. Doxorubicin delivered by liposomes targeting nucleolin enabled a level of cytotoxicity that was 2.5- or 4.6-fold higher compared to the non-targeted counterparts. Importantly, an overexpression of nucleolin was also observed in cells of patient-derived samples, as compared with normal brain. Overall, these results suggested nucleolin as a therapeutic target in GBM.

60 APPLIED LIFE SCIENCES↗

Effects of ionizing radiation and HPSE1 inhibition on the invasion of oral tongue carcinoma cells on human extracellular matrices in vitro

Highlights: • Myoma-based ECM models are suitable for in vitro chemoradiation assays. • Blocking of HPSE1 activity combined with IR may induce tongue cancer cell invasion. • Low doses of IR may increase MMP expression and invasion in tongue cancer cells. Chemoradiation is an established approach in the treatment of advanced oral tongue squamous cell carcinoma (OTSCC), but therapy may cause severe side-effects due to signal interchanges between carcinoma and the tumour microenvironment (TME). In this study, we examined the potential use of our human 3D myoma disc and Myogel models in in vitro chemoradiation studies by analysing the effects of ionizing radiation (IR) and the combined effect of heparanase I (HPSE1) inhibitors and IR on OTSCC cell proliferation, invasion and MMP-2 and − 9 production. Finally, we analysed the long-term effects of IR by studying clones of previously irradiated and invaded HSC-3 cells. We found that in both human uterine leiomyoma-based extracellular matrix models IR inhibited the invasion of HSC-3 cells, but blocking HPSE1 activity combined with IR induced their invasion. Low doses of IR increased MMP expression and initiated epithelial-mesenchymal transition in cells cultured on myoma discs. We conclude that myoma models offer consistent methods for testing human carcinoma cell invasion and phenotypic changes during chemoradiation treatment. In addition, we showed that IR had long-term effects on MMP-2 and − 9, which might elicit different HSC-3 invasion responses when cells were under the challenge of HPSE1 inhibitors and IR.

60 APPLIED LIFE SCIENCES↗

The on-axis magnetic well and Mercier's criterion for arbitrary stellarator geometries

A simplified analytical form of the on-axis magnetic well and Mercier's criterion for interchange instabilities for arbitrary three-dimensional magnetic field geometries is derived. For this purpose, a near-axis expansion based on a direct coordinate approach is used by expressing the toroidal magnetic flux in terms of powers of the radial distance to the magnetic axis. For the first time, the magnetic well and Mercier's criterion are then written as a one-dimensional integral with respect to the axis arclength. When compared with the original work of Mercier, the derivation here is presented using modern notation and in a more streamlined manner that highlights essential steps. Finally, these expressions are verified numerically using several quasisymmetric and non-quasisymmetric stellarator configurations including Wendelstein 7-X.

Physics↗

Physics basis for the Wisconsin HTS Axisymmetric Mirror (WHAM)

The Wisconsin high-temperature superconductor axisymmetric mirror experiment (WHAM) will be a high-field platform for prototyping technologies, validating interchange stabilization techniques and benchmarking numerical code performance, enabling the next step up to reactor parameters. A detailed overview of the experimental apparatus and its various subsystems is presented. WHAM will use electron cyclotron heating to ionize and build a dense target plasma for neutral beam injection of fast ions, stabilized by edge-biased sheared flow. At 25 keV injection energies, charge exchange dominates over impact ionization and limits the effectiveness of neutral beam injection fuelling. This paper outlines an iterative technique for self-consistently predicting the neutral beam driven anisotropic ion distribution and its role in the finite beta equilibrium. Beginning with recent work by Egedal et al. ( Nucl. Fusion , vol. 62, no. 12, 2022, p. 126053) on the WHAM geometry, we detail how the FIDASIM code is used to model the charge exchange sources and sinks in the distribution function, and both are combined with an anisotropic magnetohydrodynamic equilibrium solver method to self-consistently reach an equilibrium. We compare this with recent results using the CQL3D code adapted for the mirror geometry, which includes the high-harmonic fast wave heating of fast ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Asymptotic quasisymmetric high-beta three-dimensional magnetohydrodynamic equilibria near axisymmetry

Quasisymmetry (QS), a hidden symmetry of the magnetic field strength, is known to support nested flux surfaces and provide superior particle confinement in stellarators. In this work, we study the ideal magnetohydrodynamic (MHD) equilibrium and stability of high-beta plasma in a large-aspect-ratio stellarator. In particular, we show that the lowest-order description of a near-axisymmetric equilibrium vastly simplifies the problem of three-dimensional quasisymmetric MHD equilibria, which can be reduced to a standard elliptic Grad–Shafranov equation for the flux function. We show that any large-aspect-ratio tokamak, deformed periodically in the vertical direction, is a stellarator with approximate volumetric QS. We discuss exact analytical solutions and numerical benchmarks. Finally, we discuss the ideal ballooning and interchange stability of some of our equilibrium configurations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Metastability of stratified magnetohydrostatic equilibria and their relaxation

Motivated by explosive releases of energy in fusion, space and astrophysical plasmas, we consider the nonlinear stability of stratified magnetohydrodynamic equilibria against two-dimensional interchanges of straight magnetic-flux tubes. We demonstrate that, even within this restricted class of dynamics, the linear stability of an equilibrium does not guarantee its nonlinear stability: equilibria can be metastable. We show that the minimum-energy state accessible to a metastable equilibrium under non-diffusive two-dimensional dynamics can be found by solving a combinatorial optimisation problem. These minimum-energy states are, to good approximation, the final states reached by our simulations of destabilised metastable equilibria for which turbulent mixing is suppressed by viscosity. To predict the result of fully turbulent relaxation, we construct a statistical mechanical theory based on the maximisation of Boltzmann's mixing entropy. This theory is analogous to the Lynden-Bell statistical mechanics of collisionless stellar systems and plasma, and to the Robert–Sommeria–Miller theory of two-dimensional vortex turbulence. Our theory reproduces well the results of our numerical simulations for sufficiently large perturbations to the metastable equilibrium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗