Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “installations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Quantifying Error in Photovoltaic Installation Metadata: Preprint

In this research, we quantify the level of metadata error for a fleet of 2860 photovoltaic (PV) systems, using metadata values provided by fleet owners. Using satellite imagery and time series analysis techniques available in open-source Python packages Panel-Segmentation and PVAnalytics, respectively, we evaluate the accuracy of PV system metadata such as location, azimuth, tilt, and mounting configuration (fixed tilt vs. tracking). We find that approximately 75% of provided latitude-longitude coordinates are within 190 meters of the actual solar installation. We were unable to link 7.8% of latitude-longitude coordinates to any solar installation via satellite imagery analysis. We evaluate the level of error in owner-provided mounting configuration (fixed tilt vs. single-axis tracking), finding only 8 systems with an incorrect mounting configuration. When evaluating azimuth and tilt parameters, we find that approximately 64% of the data is correct, with data for 860 systems (approximately 30%) not provided by system owners. To illustrate the importance of having correct solar metadata, we evaluate how incorrect metadata affects solar performance estimates by modeling system AC energy output at ground-truth vs. incorrect latitude-longitude coordinates, mounting configurations, and azimuth-tilt configurations. Energy output estimates can vary significantly if incorrect metadata parameters are used, with incorrect mounting configuration leading to the largest discrepancy with over 20% variation in expected energy output.

azimuth↗

Method of installing a hybrid foundation for offshore wind turbines

A method of installing a hybrid foundation for an offshore wind turbine, the method includes providing a monopile, friction wheel, and suction bucket; installing the friction wheel and suction bucket in the sea floor; and inserting the monopile through the opening into the sea floor.

Zeng, Xiangwu↗

Breakdown of Electric Vehicle Supply Equipment Installation Costs

The plug-in electric vehicles (PEVs) market is receiving help from the current political climate, incentives at the federal and state levels, excessive cost of petroleum fuel, growing focus on climate solutions, increasing investment and direction by automobile manufacturers and increased awareness through media reports and advertising. Increasingly, the transportation industry, in both the United States and many other countries, is aimed at electric motive energy where practical. Increased investment in research and development have led to increasing vehicle range and lower battery costs; both of which have been deterrents in the past. The increasing demand for PEVs (consisting of the battery electric vehicle [BEV] and plug-in hybrid electric vehicle [PHEV], is challenged by the need for charging infrastructure to support these vehicles. The BEV relies totally on the on-board battery to supply the motive energy while the PHEV utilizes its battery and an installed internal combustion engine (ICE). The maximum benefit is achieved by using the battery power as much as possible. This arrangement requires the use of battery charging equipment, known as electric vehicle supply equipment (EVSE).

33 ADVANCED PROPULSION SYSTEMS↗

Long-Duration Energy Storage: Resiliency for Military Installations

This report provides a quantitative techno-economic analysis of a long-duration energy storage (LDES) technology, when coupled to on-base solar photovoltaics (PV), to meet the U.S. Department of Defense's (DoD's) 14-day requirement to sustain critical electric loads during a power outage and significantly reduce an installation's carbon footprint. The LDES modeled is Antora Energy's battery energy storage system (BESS). It is currently at a technology readiness level (TRL) of 7 and not ready for full-scale deployment. To support decisions on the value of near-term demonstrations, this analysis looked at the potential value of Antora Energy's BESS if deployed in the future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nasa research on the aerodynamics of jet vtol engine installations

This paper summarizes some of the more pertinent results of NASA investigations related to the aerodynamics of jet VTOL engine installations. It shows that there is a base loss in hovering due to suction forces creased on the underside of the fuselage by the entrainment of ambient air in the slipstream, and that the magnitude of this effect is related to the turbulence in the jet stream and its consequent rate of mixing with ambient air. It also shows that there are large lift losses and pitching moments due to jet-free-stream interference and that these characteristics can be significantly altered by proximity to the ground. And, finally, it shows that simple bellmouth inlets give good pressure recovery and low distortion for vertically mounted lift engines if the inlet lip radius is sufficiently large, but that such inlets are not suitable for windmill starting of the engines.

VTOL AIRCRAFT↗

Installation and Assembly, Electrical Ground Support Equipment (GSE), Specification for

This specification covers the general workmanship requirements and procedures for the complete installation and assembly of electrical ground support equipment (EGSE) such as terminal distributors, junction boxes, conduit and fittings, cable trays and accessories, interconnecting cables (including routing requirements), motor-control equipment, and necessary hardware as specified by the applicable contract and drawings.

Electrical and Electronics↗

NASA Engineering and Safety Center Technical Bulletin No. 15-01: Preventing Incorrect Installation of Polarized Capacitors

Even though NASA’s Lessons Learned Information System has an entry on the reverse installation of polarized capacitors, this error keeps reoccurring and is a “lesson not learned.” The purpose of this bulletin is to discuss some of the reasons this keeps happening as well as offer best practices to prevent this error in the future.

Preventing Incorrect Installation of Polarized Cap↗

Installer Badges Toolkit

As the focus on home energy efficiency grows, the National Renewable Energy Lab (NREL) and the U.S. Department of Energy (DOE) Weatherization Assistance Program (WAP) are collaborating with the home energy retrofit industry to support the development of skilled workers. The Installer Badges Toolkit provides a flexible, customizable, and voluntary approach to training and skills recognition for WAP implementers, utility programs, private sector workers, and contractors.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Foundations of Off-Grid Solar in Haiti: 6. Installation, Operations, and Maintenance of Off-Grid Solar Systems

This training lends insight into key information and concepts for off-grid solar in Haiti, building foundational knowledge and an ability to catalyze interest in off-grid solar for rural electrification in Haiti. This self-paced course is offered in both English and French and covers a variety of topics related to energy access in Haiti including off-grid solar products, market potential in Haiti, supply and demand side considerations, system design, installation and maintenance, off-grid solar business models, financial modeling, gender and energy access, productive use of energy, and climate adaptation. The training is intended for university students, government partners, NGOs, funders, development partners, professionals, and more. No prior knowledge of off-grid solar or Haiti is required to benefit from this training. See NREL/PR-7A40-89260 for the French translation of this document.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

Guide de base pour l'energie solaire hors reseau en Haiti: 6. Installation, exploitation et entretien des systemes solaires hors reseau

Cette formation donne un apercu des informations et des concepts cles de l'energie solaire hors reseau en Haiti, renforcant ainsi les connaissances fondamentales et la capacite de catalyser l'interet pour l'energie solaire hors reseau pour l'electrification rurale en Haiti. Ce cours a rythme libre est offert en anglais et en francais et couvre une variete de sujets lies a l'acces a l'energie en Haiti, notamment les produits solaires hors reseau, le potentiel du marche en Haiti, les considerations liees a l'offre et a la demande, la conception, l'installation et la maintenance du systeme, -modeles commerciaux solaires en reseau, modelisation financiere, genre et acces a l'energie, utilisation productive de l'energie et adaptation au climat. La formation est destinee aux etudiants universitaires, aux partenaires gouvernementaux, aux ONG, aux bailleurs de fonds, aux partenaires de developpement, aux professionnels, etc. Aucune connaissance prealable du solaire hors reseau ou d'Haiti n'est requise pour beneficier de cette formation. See NREL/PR-7A40-89249 for the English translation of this document.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

An experimental study of the behavior of a high efficiency residential heat pump in cooling mode with common installation faults imposed

Faults are believed to be common in split system air-conditioner and heat pump systems, due to operating degradation or installation problems. Common faults include improper refrigerant charge, reduced evaporator airflow, liquid line restrictions, and the presence of non-condensable gas. Laboratory tests were used to quantify fault impacts on performance of a heat pump system, and impacts on indicator variables such as refrigerant temperatures and pressures. This paper describes a large set of laboratory tests implemented on a high efficiency heat pump operating in cooling mode. This system uses R-410A refrigerant and has a rotary compressor, TXV, two accumulators, and a compensator. A small number of previous experimental studies have been done previously to study the effects of some operating faults, but none has examined a modern system with these components. The tests were conducted with a range of fault intensities and driving conditions. The results are compared to previous researchers’ experimental results. The system’s performance was found to be quite robust in the presence of faults. The TXV, accumulators, and compensator significantly reduce sensitivity to refrigerant charge and liquid line restriction faults, and other faults to a lesser extent.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

State-Level Trends in Renewable Energy Procurement via Solar Installation versus Green Electricity

In recent years, options for procuring renewable energy have increased, ranging from rooftop solar installation to utility green pricing to Community Choice Aggregation. These options vary in terms of costs and benefits to the consumer as well as grid integration implications. However, little is known regarding how the presence of a wide range of voluntary utility-scale renewable procurement options as well as their growth could affect adoption of distributed residential solar. To examine this relationship, we fit a two-stage least squares random effects regression model on panel data from 2016 to 2019 for all fifty US states plus the District of Columbia, controlling for variables that measure state-level policies, economic factors, and resource availability. Although there was no evidence of a strong relationship between demand for utility-scale and distributed options across all states, the state-level correlations suggest a wide variation between states including a positive, zero or negative relationship between utility-scale and distributed generation.

consumer demand↗

Strong NIR II Chiroptical Response and Magnetic Anisotropy via Modular Installation of Chiral Capping Ligands on a Light-Emitting Diradicaloid Scaffold

Low-energy molecular lumiphores have seen increased interest due to potential imaging and communications applications. Specifically, molecules that emit in the near-infrared (NIR, 700–1700 nm) or telecom (∼1260–1625 nm) regions, where attenuation is minimized in biological tissue and optical fibers, respectively, can drastically improve image resolution and depth penetration; however, bright low-energy emission is rare due to exponentially decreasing quantum yields in this region. Chiral molecules exhibiting strong NIR or telecom absorption/emission would be of particular interest due to advanced security and spintronics applications, but these compounds remain scarce and are currently restricted to lanthanide or nanoparticle-based systems. Here, we report the synthesis of a chiral organic-based NIR emitter, enabled by simple peripheral installation of chiral capping ligands. These ligands twist the achiral NIR-emissive core, breaking inversion symmetry. Furthermore, this twisting enables strong chiroptical responses observed via static and transient circular dichroism and increased magnetic anisotropy through electron paramagnetic resonance (EPR) measurements, establishing this strategy as a promising method for the development of new chiral emitters and sensors.

Electron paramagnetic resonance spectroscopy↗

Offshore wind and wave energy can reduce total installed capacity required in zero-emissions grids

Abstract As the world races to decarbonize power systems to mitigate climate change, the body of research analyzing paths to zero emissions electricity grids has substantially grown. Although studies typically include commercially available technologies, few of them consider offshore wind and wave energy as contenders in future zero-emissions grids. Here, we model with high geographic resolution both offshore wind and wave energy as independent technologies with the possibility of collocation in a power system capacity expansion model of the Western Interconnection with zero emissions by 2050. In this work, we identify cost targets for offshore wind and wave energy to become cost effective, calculate a 17% reduction in total installed capacity by 2050 when offshore wind and wave energy are fully deployed, and show how curtailment, generation, and transmission change as offshore wind and wave energy deployment increase.

16 TIDAL AND WAVE POWER↗