Long-term thermal effects on injectivity evolution during CO 2 storage

Carbon dioxide (CO 2 ) is likely to reach the bottom of injection wells at a colder temperature than that of the storage formation, causing cooling of the rock. This cooling, together with overpressure, tends to open up fractures, which may enhance injectivity. Here, we investigate cooling effects on injectivity enhancement by modeling the In Salah CO 2 storage site and a theoretical, long-term injection case. We use stress-dependent permeability functions that predict an increase in permeability as the effective stress acting normal to fractures decreases. Normal effective stress can decrease either due to overpressure or cooling. We calibrate our In Salah model, which includes a fracture zone perpendicular to the well, obtaining a good fitting with the injection pressure measured at KB-502 and the rapid CO 2 breakthrough that occurred at the observation well KB-5 located 2 km away from the injection well. CO 2 preferentially advances through the fracture zone, which becomes two orders of magnitude more permeable than the rest of the reservoir. Nevertheless, the effect of cooling on the long-term injectivity enhancement is limited in pressure dominated storage sites, like at In Salah, because most of the permeability enhancement is due to overpressure. But, thermal effects enhance injectivity in cooling dominated storage sites, which may decrease the injection pressure by 20%, saving a significant amount of compression energy all over the duration of storage projects. Overall, our simulation results show that cooling has the potential to enhance injectivity in fractured reservoirs.

58 GEOSCIENCES↗

Seismicity induced by simultaneous abrupt changes of injection rate and well pressure in Hutubi Gas Field

Hutubi gas field, the largest gas storage field in China, has been operated on annual injection/extraction cycles since 9 June 2013. Here, we study the seismicity near the gas field from 9 June 2013 to 22 October 2015, a time span that the gas field has experienced three injection periods and two extraction periods, and explore its physical mechanism based on the relationship between seismicity and field operation. We identify 273 events (ML >1) in the region within 10 km of the gas field, with 97% of those occurring in the first two injection periods, 0.4% in the third injection period and 1% in the two extraction periods. Seismicity in the first two injection periods occurs mostly as shallow clusters (focal depth < 2 km) at two locations: with one along the fault that marks the southern boundary of the gas field and the other about 2 km south to the southeastern tip of the gas field with the seismicity distributed along north-south direction. The seismicity does not correlate with total gas injection volume, injection rate or well pressure. It instead occurs 11–17 hours after simultaneous abrupt increases/decreases of gas injection rate and well pressure in the field operation in the first two injection periods when some accumulative injection has reached. Such relationship is consistent with a physical mechanism that the seismicity near Hutubi gas field is induced on pore-pressured faults with a rate- and state-dependent friction law through an abrupt change of stress in elastic and undrained poroelastic responses to simultaneous abrupt changes of injection rate and well pressure. Our study also points to the possibility that induced seismicity may be controllable in some practical field operations.

58 GEOSCIENCES↗

Energy of injection-induced seismicity predicted from in-situ experiments

The ability to predict the magnitude of an earthquake caused by deep fluid injections is an important factor for assessing the safety of the reservoir storage and the seismic hazard. Here, we propose a new approach to evaluate the seismic energy released during fluid injection by integrating injection parameters, induced aseismic deformation, and the distance of earthquake sources from injection. We use data from ten injection experiments performed at a decameter scale into fault zones in limestone and shale formations. We observe that the seismic energy and the hydraulic energy similarly depend on the injected fluid volume (V), as they both scale as V 3/2 . They show, however, a large discrepancy, partly related to a large aseismic deformation. Therefore, to accurately predict the released seismic energy, aseismic deformation should be considered in the budget through the residual deformation measured at the injection. Alternatively, the minimal hypocentral distance from injection points and the critical fluid pressure for fault reactivation can be used for a better prediction of the seismic moment in the total compilation of earthquakes observed during these experiments. Complementary to the prediction based only on the injected fluid volume, our approach opens the possibility of using alternative monitoring parameters to improve traffic-light protocols for induced earthquakes and the regulation of operational injection activities.

58 GEOSCIENCES↗

MO-FG-BRA-01: Development of An Image-Guided Dosimetric Planning System for Injectable Brachytherapy Using ELP Nanoparticles

Purpose: To develop, validate, and evaluate a methodology for determining dosimetry for intratumoral injections of elastin-like-polypeptide (ELP) brachytherapy nanoparticles. These organic-polymer-based nanoparticles are injectable, biodegradable, and genetically tunable. We present a genetically encoded polymer-solution, composed of novel radiolabeled-ELP nanoparticles that are custom-designed to self-assemble into a local source upon intratumoral injection. Our preliminary results of a small animal study demonstrate 100% tumor response, effective radionuclide retention-rates, strong in vivo stability, and no polymer-induced toxicities. While our approach is therefore highly promising for improved brachytherapy, the current workflow lacks a dosimetry framework. Methods: We are developing a robust software framework that provides image-guided dosimetric-planning capabilities for ELP brachytherapy. The user graphically places ELP injection sites within a µCT-planning-image, and independently defines each injection volume, concentration, and radioisotope to be used. The resulting internal dosimetry is then pre-determined by first modeling post-injection ELP advection-diffusion, and then calculating the resulting dose distribution based on a point- dose-kernel-convolution algorithm. We have experimentally measured ELP steady-state concentrations via µSPECT acquisition, and validated our dose calculation algorithm against Monte Carlo simulations of several radioactivity distributions. Finally, we have investigated potential advantages and limitations of various ELP injection parameters. Results: The µSPECT results demonstrated inhomogeneous steady-state distributions of ELP in tissue, and Monte Carlo radioactivity distributions were designed accordingly. Our algorithm yielded a root-mean-square-error of less than 2% for each distribution tested (average root-mean-square-error was 0.73%). Dose-Volume-Histogram analysis of five different plans showed how strategic injection placement, and an injection volume-tapering technique, could be used to achieve D95% target coverage. Conclusion: We have preliminarily developed a novel planning framework for ELP brachytherapy. Its dosimetry accuracy has been validated against Monte Carlo, and we have started to investigate the potential advantages of injection-based planning. This system, once fully developed, will serve as the technical foundation for our novel approach.

60 APPLIED LIFE SCIENCES↗

Effect of mass-addition distribution and injectant on heat transfer and transition criteria.

Surface pressures, heat-transfer rates, and transition locations for a sharp cone (whose semivertex angle is 12 deg) were obtained in a hypervelocity wind tunnel at a free-stream Mach number of 12 and a free-stream Re/ft range of 3,000,000 to 6,000,000. The effects of injecting either methane, nitrogen, or Freon-22 (at rates up to 2.1% of free-stream rate) were studied for a uniform injection-distribution and for a variable injection-distribution. Gaseous injection had little effect on the surface pressure measurements. For a given mass injection distribution, the laminar region heat-transfer decreases as the injection rate increases or as the molecular weight of the injectant decreases. For a given mass-injection rate (integrated over the surface of the entire cone), the transition location and heat-transfer rates were sensitive to the injection distribution. The transition Reynolds numbers were significantly greater when the local injection rate was constant over the surface of the cone.

Bertin, J. J.↗

The Effect of Injection-Valve Opening Pressure on Spray-Tip Penetration

The effect of various injection-valve opening pressures on the spray-tip penetration was determined for several injection pressure. A common-rail fuel injection system was used. For a given injection pressure a maximum rate of penetration was obtained with an injection-valve opening pressure equal to the injection pressure. As the excess of the injection pressure over the injection-valve opening pressure was increased for a given injection pressure, the effect of the injection-valve opening pressure on the spray-tip penetration was increased.

Rothrock, A M↗

Plasma and energetic particle properties of dispersionless substorm injections at geosynchronous orbit

Using a year's worth of geosynchronous spacecraft data, the substorm associated behavior of the thermal plasma in the plasma sheet in relation to energetic particle injections is reviewed. Five classes of injection events were found: ion injections without accompanying electron injection at 21 local time (LT); ion injection followed a few minutes later by an electron injection at 22 LT; simultaneous ion and electron injection close to midnight; electron injections followed by an ion injection at 01 LT; and pure electron injections at 02 LT. The thermal electrons show a significant increase in temperature and pressure at substorm onset, while the density and thermal ion signatures are typically weak. Energetic ions are found to contribute to the total ion pressure and temperature. Preexisting perpendicular anisotropies in the thermal electrons and ions are reduced during the substorm growth phase, but are re-enhanced after onset.

Birn, J.↗

Kepler Planet Detection Metrics: Per-Target Flux-Level Transit Injection Tests of TPS for Data Release 25

Quantifying the ability of a transiting planet survey to recover transit signals has commonly been accomplished through Monte-Carlo injection of transit signals into the observed data and subsequent running of the signal search algorithm (Gilliland et al., 2000; Weldrake et al., 2005; Burke et al., 2006). In order to characterize the performance of the Kepler pipeline (Twicken et al., 2016; Jenkins et al., 2017) on a sample of over 200,000 stars, two complementary injection and recovery tests are utilized:1. Injection of a single transit signal per target into the image or pixel-level data, hereafter referred to as pixel-level transit injection (PLTI), with subsequent processing through the Photometric Analysis (PA), Presearch Data Conditioning (PDC), Transiting Planet Search (TPS), and Data Validation (DV) modules of the Kepler pipeline. The PLTI quantification of the Kepler pipeline's completeness has been described previously by Christiansen et al. (2015, 2016); the completeness of the final SOC 9.3 Kepler pipeline acting on the Data Release 25 (DR25) light curves is described by Christiansen (2017).2. Injection of multiple transit signals per target into the normalized flux time series data with a subsequent transit search using a stream-lined version of the Transiting Planet Search (TPS) module. This test, hereafter referred to as flux-level transit injection (FLTI), is the subject of this document. By running a heavily modified version of TPS, FLTI is able to perform many injections on selected targets and determine in some detail which injected signals are recoverable. Significant numerical efficiency gains are enabled by precomputing the data conditioning steps at the onset of TPS and limiting the search parameter space (i.e., orbital period, transit duration, and ephemeris zero-point) to a small region around each injected transit signal.The PLTI test has the advantage that it follows transit signals through all processing steps of the Kepler pipeline, and the recovered signals can be further classified as planet candidates or false positives in the exact same manner as detections from the nominal (i.e., observed) pipeline run (Twicken et al., 2016, Thompson et al., in preparation). To date, the PLTI test has been the standard means of measuring pipeline completeness averaged over large samples of targets (Christiansen et al., 2015, 2016; Christiansen, 2017). However, since the PLTI test uses only one injection per target, it does not elucidate individual-target variations in pipeline completeness due to differences in stellar properties or astrophysical variability. Thus, we developed the FLTI test to provide a numerically efficient way to fully map individual targets and explore the performance of the pipeline in greater detail. The FLTI tests thereby allow a thorough validation of the pipeline completeness models (such as window function (Burke and Catanzarite, 2017a), detection efficiency (Burke Catanzarite, 2017b), etc.) across the spectrum of Kepler targets (i.e., various astrophysical phenomena and differences in instrumental noise). Tests during development of the FLTI capability revealed that there are significant target-to-target variations in the detection efficiency.

DR25↗

The impact of fuel and injection strategy on combustion characteristics, emissions and efficiency in gasoline compression ignition operation

Gasoline compression ignition in diesel engines has been proposed in order to meet increasingly stringent emission regulations without sacrificing efficiency. In this study, a six-cylinder heavy-duty diesel engine was operated in a mixing controlled gasoline compression ignition mode to investigate the influence of fuels and injection strategies on the combustion characteristics, emissions, and thermal efficiencies. Fuels, including ethanol (E), isobutanol (IB), and diisobutylene (DIB), were blended with a gasoline fuel to form E10, E30, IB30, and DIB30 based on volumetric fraction. These four blends along with gasoline formed the five test fuels. With these fuels, three injections strategies were investigated, including late pilot injection, early pilot injection, and port fuel injection/direct injection. The impact of moderate exhaust gas recirculation on nitrogen oxides and soot emissions was examined to determine the most promising fuel/injection strategy for emissions reduction. In addition, first and second law analyses were performed to provide insights into the efficiency, loss, and exergy destruction of the various gasoline fuel blends at low and medium load conditions. Overall, the emission output, thermal efficiency, and combustion performances of the five fuels were found to be similar and their differences are modest under most test conditions. E30 with the port/direct fuel injection strategy obtained the peak brake thermal efficiency (46.9%) and gross indicated thermal efficiency (52.2%) at 14 bar. At 7 bar, the peak brake thermal efficiency (44.2%) and gross indicated thermal efficiency (52.5%) also belonged to E30 with the late pilot injection strategy. The second law analysis revealed that exergy destruction was mostly influenced by the fuel type and not by the injection strategy for the 14 bar operating conditions. However, the opposite trend was observed for the 7 bar case. In addition, port fuel injection in combination with oxygenated fuel blends was found to be helpful to suppress soot emissions for operation with exhaust gas recirculation.

co-optima fuels↗

Understanding syringeability and injectability of high molecular weight PEO solution through time-dependent force-distance profiles

Opioid medications play a vital role in treating moderate to severe pain. Unfortunately, many drug misusers and abusers attempt to alter the formulations or properties of these drugs by manipulation, (e.g., crushing, chewing, smoking, snorting, injecting). The intravenous (IV) route is most dangerous to abusers, as the drugs directly enter the circulatory system and produce intense euphoria. To obtain a full understanding of the impact of syringe factors (e.g., needle gauge size, needle length, syringe barrel size), on the ease of injection, we undertook a comprehensive assessment of syringeability and injectability of manipulated abuse-deterrent formulations (ADFs). A texture analyzer-based testing method was developed for the measurement of the resistance force of pulling, holding, and pushing phases of injections. Results showed that the finer needle gauge sizes required higher injection force to withdraw drug solutions. In addition, the syringed liquid volume was highly dependent on needle gauge size, holding time, and sample viscosity. In most cases, a lower needle gauge number and a longer holding time increased the syringed volume. Needle length was highly correlated to injection force (R 2 = 0.99). Using longer needles to inject drug solution requires greater force. Furthermore, large barrel size was correlated to pushing force (R 2 = 0.99); thus, increasing the difficulty of pushing the plunger of a large syringe with one hand. Lastly, relationships between injection force, sample viscosity, and testing conditions were elucidated using a mathematical model, which could be used in the future to assess and predict injection force of solution samples.

60 APPLIED LIFE SCIENCES↗

Machine-learning based prediction of injection rate and solenoid voltage characteristics in GDI injectors

We report that current state-of-the-art gasoline direct-injection (GDI) engines use multiple injections as one of the key technologies to improve exhaust emissions and fuel efficiency. For this technology to be successful, secured adequate control of fuel quantity for each injection is mandatory. However, nonlinearity and variations in the injection quantity can deteriorate the accuracy of fuel control, especially with small fuel injections. Therefore, it is necessary to understand the complex injection behavior and to develop a predictive model to be utilized in the development process. This study presents a methodology for rate of injection (ROI) and solenoid voltage modeling using artificial neural networks (ANNs) constructed from a set of Zeuch-style hydraulic experimental measurements conducted over a wide range of conditions. A quantitative comparison between the ANN model and the experimental data shows that the model is capable of predicting not only general features of the ROI trend, but also transient and non-linear behaviors at particular conditions. In addition, the end of injection (EOI) could be detected precisely with a virtually generated solenoid voltage signal and the signal processing method, which applies to an actual engine control unit. A correlation between the detected EOI timings calculated from the modeled signal and the measurement results showed a high coefficient of determination.

42 ENGINEERING↗

Axisymmetric flows from fluid injection into a confined porous medium

In this work, we study the axisymmetric flows generated from fluid injection into a horizontal confined porous medium that is originally saturated with another fluid of different density and viscosity. Neglecting the effects of surface tension and fluid mixing, we use the lubrication approximation to obtain a nonlinear advection-diffusion equation that describes the time evolution of the sharp fluid-fluid interface. The flow behaviors are controlled by two dimensionless groups: M , the viscosity ratio of displaced fluid relative to injected fluid, and Γ , which measures the relative importance of buoyancy and fluid injection. For this axisymmetric geometry, the similarity solution involving R 2 /T (where R is the dimensionless radial coordinate and T is the dimensionless time) is an exact solution to the nonlinear governing equation for all times. Four analytical expressions are identified as asymptotic approximations (two of which are new solutions): (i) injection-driven flow with the injected fluid being more viscous than the displaced fluid ( Γ $\ll$ 1 and M < 1) where we identify a self-similar solution that indicates a parabolic interface shape; (ii) injection-driven flow with injected and displaced fluids of equal viscosity ( Γ $\ll$ 1 and M = 1), where we find a self-similar solution that predicts a distinct parabolic interface shape; (iii) injection-driven flow with a less viscous injected fluid ( Γ $\ll$ 1 and M > 1) for which there is a rarefaction wave solution, assuming that the Saffman-Taylor instability does not occur at the reservoir scale; and (iv) buoyancy-driven flow ( Γ $\gg$ 1) for which there is a well-known self-similar solution corresponding to gravity currents in an unconfined porous medium [S. Lyle et al. “Axisymmetric gravity currents in a porous medium,” J. Fluid Mech. 543, 293–302 (2005)]. The various axisymmetric flows are summarized in a Γ - M regime diagram with five distinct dynamic behaviors including the four asymptotic regimes and an intermediate regime. The implications of the regime diagram are discussed using practical engineering projects of geological CO 2 sequestration, enhanced oil recovery, and underground waste disposal.

42 ENGINEERING↗

Cluster ion source for external injection and high capacity filling of light elements into the relativistic heavy ion collider electron beam ion source

An advanced Electron Beam Ion Source (EBIS) is the primary ion source to supply highly charged ion beams of different elements to the Relativistic Heavy Ion Collider (RHIC) and to the NASA Space Radiation Laboratory (NSRL). Intense beams of highly charged ions of various elements of the periodic table, ranging from helium to uranium, have been demonstrated since EBIS became operational in 2010. EBIS routinely provides ion beams to RHIC and NSRL quasisimultaneously with about 1 s switching time between different ion species. Such unique flexibility and rapid switching between ion species are based on external injection of singly charged ions into the EBIS trap either in “fast” or “slow” injection modes. At present, a Laser Ion Source (LIS) provides most of the ion species of solid materials using the “fast” injection mode into the EBIS trap and a Hollow Cathode Ion Source (HCIS) provides most of the ion species of gaseous elements using the “slow” injection mode into the EBIS trap. Gas injection into the EBIS trap is also possible and has been used but imposes some restrictions for the simultaneous generation of highly charged ions such as Au 32+ ions for RHIC and ions of gaseous species for NSRL. Because light ions have relatively high velocity inside the EBIS trap, efficient injection of hydrogen and helium ions and filling of the EBIS trap to high capacity is difficult from either LIS or HCIS. To overcome this restriction and enhance EBIS operational capability, we suggest injecting beams of hydrogen and helium cluster ions into the EBIS trap. Required parameters of cluster ion beam injection into the EBIS trap are estimated, and advantages of such an injection are highlighted. A cluster ion source with required high intensity is visible and will be designed, built, optimized, and tested.

43 PARTICLE ACCELERATORS↗

Mortality, Transmitter Retention, Growth, and Wound Healing in Juvenile Salmon Injected with Micro Acoustic Transmitters

A cylindrical acoustic transmitter (AT; 0.2 g) has been developed for injection into the peritoneum of fish. Laboratory studies can provide tagging guidelines to minimize the effect of implantation techniques and transmitter burden (relative weight of the transmitter to the weight of the fish) in fish before a transmitter is used in field studies. The goal of this study was to examine response variables (mortality, transmitter expulsion, growth, wound area) of juvenile Chinook Salmon (Oncorhynchus tschawytscha; 65–104 mm fork length [FL]) injected with an AT along a wide range of sizes that could lead to a guideline for minimizing tagging effects. The overarching goal was to determine a minimum size threshold for fish that can be injected, while minimizing adverse transmitter effects. Juveniles (n = 700) were separated into four treatments: (1) acoustic transmitter injection (AT), (2) AT and a passive integrated transponder tag injection (AT+PIT), (3) visual implant elastomer injection (Marked control), and (4) unmarked (Unmarked control). Fish were evaluated weekly for four weeks, and again at the end of the study (60 d post-tagging). Fish injected with an AT or an AT+PIT experienced greater mortality than Marked controls. By 60 d post-tagging, transmitter expulsion was 44% for AT fish and 20% for AT+PIT fish. Fish injected with an AT or an AT+PIT grew (FL and weight gain) significantly less than Marked controls, and no minimum size thresholds were detected. Finally, initial size (FL) significantly affected wound area in AT and AT+PIT fish. A size threshold was only identified on Day 7 (85.1 mm) for AT+PIT fish, indicating that wound areas in fish < 85.1 mm were larger than wound areas of fish > 85.1 mm. This research suggests that injecting juveniles with an AT or an AT+PIT had a greater effect on smaller fish than larger fish.

Chinook↗

Surface Deformation and Seismicity Linked to Fluid Injection in the Raton Basin

Abstract It is suggested that in addition to seismicity deep fluid injection may cause surface uplift and subsidence in oil and gas‐producing regions. This study uses the Raton Basin as an example to investigate the hydromechanical processes of surface uplift and subsidence during wastewater injection. The Raton Basin, in southern central Colorado and northern central New Mexico, has experienced wastewater injection related to coalbed methane and gas production starting in 1994. In this study, we estimate the extent and magnitude of total vertical deformation in the Raton Basin from 1994 to 2020 and incremental deformation between the years 2017 to 2020. Results indicate a modeled uplift as much as 15 cm occurring between 1994 and 2020. Between 2017 and 2020, up to 3 cm of uplift occurred, largely near the northwestern injection wells. Most modeled uplift between 1994 and 2020 occurred near the southern wells, where the greatest cumulative volume of wastewater was injected. However, modeled subsidence occurred around the southern and eastern wells between 2017 and 2020, after the rate of injection decreased. Modeling indicates that while the magnitude of modeled uplift corresponds to cumulative injection volume and maximum rate in the long‐term, short‐term incremental deformation (uplift or subsidence) is controlled by changes in the rate of injection. The number of yearly earthquake events follows periods of rapid modeled uplifting throughout the Basin, suggesting that measurable surface deformation may be caused by the same injection‐induced pore pressure perturbations that initiate seismicity.

Geology↗

Flattening the field during injection in the Fermilab booster using dipole corrector magnets

The FNAL Booster is a fast cycling 15 Hz resonant circuit synchrotron accelerating proton beam from 400 MeV to 8 GeV. The linac pulse injected into the Booster is ~32 μsec long and fills the ring by multi-turn charge-exchange injection. As part of the PIP-II project, the Booster injection energy and repetition rate will be increased to 800 MeV and 20 Hz respectively. Due to much reduced average current in the new superconducting PIP-II linac, the injection time will increase to 550 μs. A shorter machine cycle coupled to a longer injection time make flattening the injection porch B-field during injection important requirement for successful PIP-II operation. We aim to achieve: (1) flattening of the net bending during injection using dipole correctors, and (2) using a new system based on an Altera FPGA board, reduction of the cycle-to-cycle bending field variation caused by current jitter in the Gradient Magnet Power Supply (GMPS). While the flat injection scheme is essential to future PIP-II operations, it should also noticeably improve efficiency for present HEP operations.

43 PARTICLE ACCELERATORS↗

DUS II Soil Gas Sampling and Air Injection Test Results

Soil vapor extraction (SVE) and air injection well testing was performed at the Dynamic Underground Stripping (DUS) site located near the M-Area Settling Basin (referred to as DUS II in this report). The objective of this testing was to determine the effectiveness of continued operation of these systems. Steam injection ended on September 19, 2009 and since this time the extraction operations have utilized residual heat that is present in the subsurface. The well testing campaign began on June 5, 2012 and was completed on June 25, 2012. Thirty-two (32) SVE wells were purged for 24 hours or longer using the active soil vapor extraction (ASVE) system at the DUS II site. During each test five or more soil gas samples were collected from each well and analyzed for target volatile organic compounds (VOCs). The DUS II site is divided into four parcels (see Figure 1) and soil gas sample results show the majority of residual VOC contamination remains in Parcel 1 with lesser amounts in the other three parcels. Several VOCs, including tetrachloroethylene (PCE) and trichloroethylene (TCE), were detected. PCE was the major VOC with lesser amounts of TCE. Most soil gas concentrations of PCE ranged from 0 to 60 ppmv with one well (VEW-22A) as high as 200 ppmv. Air sparging (AS) generally involves the injection of air into the aquifer through either vertical or horizontal wells. AS is coupled with SVE systems when contaminant recovery is necessary. While traditional air sparging (AS) is not a primary component of the DUS process, following the cessation of steam injection, eight (8) of the sixty-three (63) steam injection wells were used to inject air. These wells were previously used for hydrous pyrolysis oxidation (HPO) as part of the DUS process. Air sparging is different from the HPO operations in that the air was injected at a higher rate (20 to 50 scfm) versus HPO (1 to 2 scfm). . At the DUS II site the air injection wells were tested to determine if air sparging affected VOC soil gas concentrations during ASVE. Five (5) SVE wells that were located closest to the air injection wells were used as monitoring points during the air sparging tests. The air sparging tests lasted 48 hours. Soil gas sample results indicate that sparging did not affect VOC concentrations in four of the five sparging wells, while results from one test did show an increase in soil gas concentrations.

54 ENVIRONMENTAL SCIENCES↗

Diagnostic Cardiac Catheterization Using the MEDRAD Avanta™ Fluid Management System as Compared to the Traditional Manual Injection Method

Nearly 4 million patient procedures performed annually in US cardiac catheterization laboratories utilize contrast media to achieve vessel opacification. The amount of contrast media used is variable and depends on the complexity of the procedure, the method of contrast delivery as well as the skill-level of the operator. Since the total amount of contrast used for each procedure can have both patient safety and economic implications, it is essential for cardiologists to have the ability to control contrast delivery such that optimal angiographic image quality is achieved using the least amount of contrast. Although the complication rate associated with cardiac catheterization remains low, the most common serious complication, contrast-induced nephropathy (CIN), is associated with poor prognosis and a high mortality rate. Numerous interventional strategies for preventing and reducing the severity of CIN have demonstrated varying degrees of clinical benefit, but none has been shown to reliably prevent this serious complication. To date, the most effective approach for reducing the risk of CIN is to properly hydrate the patient and to minimize the amount of contrast media administered. Automated injection systems are intended for use in virtually all cardiac catheterization procedures and have numerous features which can provide potential advantages over traditional methods. With automated injection technology the operator is able to control and precisely monitor contrast delivery. Additionally, the MEDRAD Avanta Fluid Management Injection System utilizes a sterile contrast reservoir which eliminates the need to discard unused contrast in individual opened containers following each procedure. Considering that an average of 50% of opened contrast media is wasted using manual injection methods, this savings can provide a substantial economic benefit. Automated systems also facilitate the use of smaller (5 French) catheter sizes. Precise flow control and the use of smaller diameter catheters have both been shown to reduce the volume of contrast administered. The use of smaller size catheters also permits more rapid hemostasis, thus allowing shorter ambulation time without the need for costly wound closure devices. These factors can result in enhanced patient satisfaction as well as more efficient management of post-procedure rooms. The intent of this study was to demonstrate that using the MEDRAD Avanta™ Fluid Management Injection System (MEDRAD, INC., Pittsburgh, PA) for coronary diagnostic procedures can produce a reduction in the volume of contrast administered without loss of operational quality or efficiency. In addition, this study will explore procedure time and efficiency in an effort to minimize the amount of ionizing radiation delivered to the patient as well as the diagnostic team members. Study Design This is a post-market study designed to collect data during diagnostic cardiac catheterization when utilizing 5FR or 6FR catheters in conjunction with the Avanta Fluid Management System or a manual manifold injection method control group. A minimum of 420 patients scheduled for diagnostic cardiac catheterization will be enrolled in the study cohort. Patients will be assigned into the following two groups. Group 1: Catheterization with 5FR or 6FR catheters, using the traditional manual manifold injection method for contrast media delivery which is defined as manual hand injection of contrast media through a 3 or 4 port manifold and left ventriculography performed via standard fixed rate power injection. Group 2: Catheterization with 5FR or 6FR catheters, using the MEDRAD Avanta™ system for contrast media delivery. Study endpoints include volume of contrast media administered during diagnostic cardiac catheterization, volume of contrast media wasted post-procedure, procedure time (defined as the time from first catheter insertion to last diagnostic catheter removal), fluoroscopy time and angiographic image quality. The study demonstrated that use of the Advanta system reduced overall contrast utilization by decreasing the amount of contrast administered to the patient and reducing the amount of contrast wasted during preparation and post-procedure clean-up. The quality of the angiographic images and the radiation exposure to the patient were not affected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗