Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “incomplete”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Incomplete Data in Smart Grid: Treatment of Values in Electric Vehicle Charging Data

In this paper, five imputation methods namely Constant (zero), Mean, Median, Maximum Likelihood, and Multiple Imputation methods have been applied to compensate for missing values in Electric Vehicle (EV) charging data. The outcome of each of these methods have been used as the input to a prediction algorithm to forecast the EV load in the next 24 hours at each individual outlet. The data is real world data at the outlet level from the UCLA campus parking lots. Given the sparsity of the data, both Median and Constant (=zero) imputations improved the prediction results. Since in most missing value cases in our database, all values of that instance are missing, the multivariate imputation methods did not improve the results significantly compared to univariate approaches.

Majipour, Mostafa↗

Evaluation of accuracy of calculations of VVER-1000 core states with incomplete covering of fuel by the absorber

An additional verification of bundled software (BS) SAPFIR-95 and amp;RC [1] and code KORSAR/GP [2] was performed. Both software products were developed in A.P. Alexandrov NITI and certified by ROSTEKHNADZOR of RF for numeric simulation of stationary, transitional and emergency conditions of VVER reactors. A benchmark model for neutronics calculations was created within the limits of this work. The cold subcritical state of VVER - 1000 reactor stationary fuelling was simulated on the basis of FA with an increased height of the fuel column (TVS-2M) considering detailed presentation of radial and front neutron reflectors. A case of passing of pure condensate slug through the core in initially deep subcritical state during start of the first RCP set after refueling was considered as an examined condition of reactor operation. A relatively small size of the slug, its spatial position near the reflectors (lower and lateral), as well as failure of the inserted control rods of the control and protection system (CPS CR) to reach the lower limit of the fuel column stipulate for methodical complexity of a correct calculation of the neutron multiplication constant (K{sub eff}) using engineering codes. Code RC was used as a test program in the process of reactor calculated 3-D modeling. Code MCNP5 [3] was used as the precision program, which solves the equation of neutrons transfer by Monte-Carlo method and which was developed in the US (Los-Alamos). As a result of comparative calculations dependency of K{sub eff} on two parameters was evaluated - boron acid concentration (Cb) and CPS CR position. Reactivity effect was evaluated, which is implemented as a result of failure of all CPS control rods to reach the lower fuel limit calculated using the engineering codes mentioned above. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Limitations imposed on fire PRA methods as the result of incomplete and uncertain fire event data.

Fire probabilistic risk assessment (PRA) methods utilize data and insights gained from actual fire events in a variety of ways. For example, fire occurrence frequencies, manual fire fighting effectiveness and timing, and the distribution of fire events by fire source and plant location are all based directly on the historical experience base. Other factors are either derived indirectly or supported qualitatively based on insights from the event data. These factors include the general nature and intensity of plant fires, insights into operator performance, and insights into fire growth and damage behaviors. This paper will discuss the potential methodology improvements that could be realized if more complete fire event reporting information were available. Areas that could benefit from more complete event reporting that will be discussed in the paper include fire event frequency analysis, analysis of fire detection and suppression system performance including incipient detection systems, analysis of manual fire fighting performance, treatment of fire growth from incipient stages to fully-involved fires, operator response to fire events, the impact of smoke on plant operations and equipment, and the impact of fire-induced cable failures on plant electrical circuits.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Reaction mechanisms in the system {sup 20}Ne+{sup 165}Ho: Measurement and analysis of forward recoil range distributions

Keeping in view the study of complete and incomplete fusion of heavy ions with a target, the forward recoil range distributions of several evaporation residues produced at 164 MeV {sup 20}Ne-ion beam energy have been measured for the system {sup 20}Ne+{sup 165}Ho. The recoil catcher activation technique followed by off-line gamma spectroscopy has been employed. Measured forward recoil range distributions of these evaporation residues show evidence of several incomplete fusion channels in addition to complete fusion. The entire and partial linear momentum transfers inferred from these recoil range distributions were used to identify the evaporation residues formed by complete and incomplete fusion mechanisms. The results indicate the occurrence of incomplete fusion involving the breakup of {sup 20}Ne into {sup 4}He+{sup 16}O and/or {sup 8}Be+{sup 12}C followed by fusion of one of the fragments with target nucleus {sup 165}Ho. Complete and incomplete fusion reaction channels have been identified in the production of various evaporation residues and an attempt has been made to separate out relative contributions of complete and incomplete fusion components from the analysis of the measured recoil range distribution data. The total contribution of complete and incomplete fusion channels has also been estimated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-560: Commissioning An HDR Freiburg Flap Applicator for Skin Lesion Treatment

Purpose: Flexible Freiburg flap used with high dose rate afterloaders is easy to cut into any size for any body site and to dwell with a precise source position, conforms to curved skin surface and then to the planned target. However, unlike intracavity or interstitial situations, incomplete scatter environment due to flap applicators exposed to air might lead to dose difference between the delivered and planned. This research is focused on the dose deviation of incomplete scatter versus full scatter. Methods: A 12x12 cm of Freiburg flap applicator was used for the validation. A Nucletron Oncentra Brachy Ver. 4.3 treatment planning system (TPS) was used for treatment planning. However, no heterogeneity correction incorporated into the brachytherap TPS needs to be considered. A Philips Brilliance CT Big Bore was employed for CT scan. Radiation was delivered using a Nucletron HDR remote afterloader system. A 10cm bolus was used to cover the flap for obtaining a full scatter. An OSL, ion chamber, and Gafchromic EBT2 film were used for commissioning the flap applicator. Results: The applicator calibration at 5mm depth was performed using an OSL dosimeter. Applicator source dwelling positions with 1D and 2D array exposed to and recorded by Gafchromic EBT2 film showed an agreement within 1mm. 1D array of Freiburg flap exhibited 4.2% cooler in dose with incomplete scatter than full scatter. 2D array showed 7.1% lower in dose for incomplete scatter than full scatter. The deviation was found more than 10% beyond 8cm in depth. Conclusion: Significant dose deviation caused by the incomplete scatter environment was found to be 7.1% at 1cm depth. This deviation was increased with increasing depth. The inaccuracy resulted from the incomplete scatter can be fixed by either placing a bolus on the top of the flap or making the plan at least 7% hotter.

07 ISOTOPE AND RADIATION SOURCES↗

Endovascular Aneurysm Repair: Is Imaging Surveillance Robust, and Does It Influence Long-term Mortality?

PurposeEndovascular aneurysm repair (EVAR) is the dominant treatment strategy for abdominal aortic aneurysms. However, as a result of uncertainty regarding long-term durability, an ongoing imaging surveillance program is required. The aim of the study was to assess EVAR surveillance in Scotland and its effect on all-cause and aneurysm-related mortality.MethodsA retrospective analysis of all EVAR procedures carried out in the four main Scottish vascular units. The primary outcome measure was the implementation of post-EVAR imaging surveillance across Scotland. Patients were identified locally and then categorized as having complete, incomplete, or no surveillance. Secondary outcome measures were all-cause mortality and aneurysm-related mortality. Cause of death was obtained from death certificates.ResultsData were available for 569 patients from the years 2001 to 2012. All centers had data for a minimum of 5 contiguous years. Surveillance ranged from 1.66 to 4.55 years (median 3.03 years). Overall, 53 % had complete imaging surveillance, 43 % incomplete, and 4 % none. For the whole cohort, all-cause 5-year mortality was 33.5 % (95 % confidence interval 28.0–38.6) and aneurysm-related mortality was 4.5 % (.8–7.3). All-cause mortality in patients with complete, incomplete, and no imaging was 49.9 % (39.2–58.6), 19.1 % (12.6–25.2), and 47.2 % (17.7–66.2), respectively. Aneurysm-related mortality was 3.7 % (1.8–7.4), 4.4 % (2.2–8.9), and 9.5 % (2.5–33.0), respectively. All-cause mortality was significantly higher in patients with complete compared to incomplete imaging surveillance (p < 0.001). No significant differences were observed in aneurysm-related mortality (p = 0.2).ConclusionOnly half of EVAR patients underwent complete long-term imaging surveillance. However, incomplete imaging could not be linked to any increase in mortality. Further work is required to establish the role and deliverability of EVAR imaging surveillance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy and Usefulness of Select Methods for Assessing Complete Collection of 24‐Hour Urine: A Systematic Review

Twenty‐four–hour urine collection is the recommended method for estimating sodium intake. To investigate the strengths and limitations of methods used to assess completion of 24‐hour urine collection, the authors systematically reviewed the literature on the accuracy and usefulness of methods vs para‐aminobenzoic acid ( PABA ) recovery (referent). The percentage of incomplete collections, based on PABA , was 6% to 47% (n=8 studies). The sensitivity and specificity for identifying incomplete collection using creatinine criteria (n=4 studies) was 6% to 63% and 57% to 99.7%, respectively. The most sensitive method for removing incomplete collections was a creatinine index <0.7. In pooled analysis (≥2 studies), mean urine creatinine excretion and volume were higher among participants with complete collection ( P <.05); whereas, self‐reported collection time did not differ by completion status. Compared with participants with incomplete collection, mean 24‐hour sodium excretion was 19.6 mmol higher (n=1781 specimens, 5 studies) in patients with complete collection. Sodium excretion may be underestimated by inclusion of incomplete 24‐hour urine collections. None of the current approaches reliably assess completion of 24‐hour urine collection.

John, Katherine A.↗

Investigation of the role of break-up processes on the fusion of {sup 16}O induced reactions

An experiment was carried out to explore heavy ion incomplete fusion reaction dynamics, within the framework of the break-up fusion model, at energies near and above the Coulomb barrier. Excitation functions for several radionuclides produced via xn, pxn, and {alpha}xn channels were measured in the {sup 16}O+{sup 181}Ta system at energies of {approx_equal}76-100 MeV. The experimental excitation functions were compared with those calculated using the theoretical model code PACE4. It was observed that excitation functions of xn/pxn channels are in good agreement with theoretical predictions. However, a significant enhancement in the measured excitation functions of {alpha}-emitting channels was observed and attributed to the incomplete fusion processes. The incomplete fusion fraction (F{sub ICF}) that gives the relative importance of complete and incomplete fusion processes was found to increase with energy. The results are discussed in terms of {alpha}-cluster structure of the projectile on various fusion reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Lung Tumor Radiofrequency Ablation: Where Do We Stand?

Today, radiofrequency ablation (RFA) of primary and metastatic lung tumor is increasingly used. Because RFA is most often used with curative intent, preablation workup must be a preoperative workup. General anesthesia provides higher feasibility than conscious sedation. The electrode positioning must be performed under computed tomography for sake of accuracy. The delivery of RFA must be adapted to tumor location, with different impedances used when treating tumors with or without pleural contact. The estimated rate of incomplete local treatment at 18 months was 7% (95% confidence interval, 3-14) per tumor, with incomplete treatment depicted at 4 months (n = 1), 6 months (n = 2), 9 months (n = 2), and 12 months (n = 2). Overall survival and lung disease-free survival at 18 months were, respectively, 71 and 34%. Size is a key point for tumor selection because large size is predictive of incomplete local treatment and poor survival. The ratio of ablation volume relative to tumor volume is predictive of complete ablation. Follow-up computed tomography that relies on the size of the ablation zone demonstrates the presence of incomplete ablation. Positron emission tomography might be an interesting option. Chest tube placement for pneumothorax is reported in 8 to 12%. Alveolar hemorrhage and postprocedure hemoptysis occurred in approximately 10% of procedures and rarely required specific treatment. Death was mostly related to single-lung patients and hilar tumors. No modification of forced expiratory volume in the first second between pre- and post-RFA at 2 months was found. RFA in the lung provides a high local efficacy rate. The use of RFA as a palliative tool in combination with chemotherapy remains to be explored.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Furniture wood wastes: Experimental property characterisation and burning tests

Referring to the industrial wood waste category (as dominant in the provincial district of Pesaro-Urbino, Marche Region, Italy), this paper deals with the experimental characterisation and the carrying out of non-controlled burning tests (at lab- and pilot-scale) for selected 'raw' and primarily 'engineered' ('composite') wood wastes. The property characterisation has primarily revealed the following aspects: potential influence on moisture content of local weather conditions at outdoor wood waste storage sites; generally, higher ash contents in 'engineered' wood wastes as compared with 'raw' wood wastes; and relatively high energy content values of 'engineered' wood wastes (ranging on the whole from 3675 to 5105 kcal kg{sup -1} for HHV, and from 3304 to 4634 kcal kg{sup -1} for LHV). The smoke qualitative analysis of non-controlled lab-scale burning tests has primarily revealed: the presence of specific organic compounds indicative of incomplete wood combustion; the presence exclusively in 'engineered' wood burning tests of pyrroles and amines, as well as the additional presence (as compared with 'raw' wood burning) of further phenolic and containing nitrogen compounds; and the potential environmental impact of incomplete industrial wood burning on the photochemical smog phenomenon. Finally, non-controlled pilot-scale burning tests have primarily given the following findings: emission presence of carbon monoxide indicative of incomplete wood combustion; higher nitrogen oxide emission values detected in 'engineered' wood burning tests as compared with 'raw' wood burning test; and considerable generation of the respirable PM{sub 1} fraction during incomplete industrial wood burning.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RECONSTRUCTING REDSHIFT DISTRIBUTIONS WITH CROSS-CORRELATIONS: TESTS AND AN OPTIMIZED RECIPE

Many of the cosmological tests to be performed by planned dark energy experiments will require extremely well-characterized photometric redshift measurements. Current estimates for cosmic shear are that the true mean redshift of the objects in each photo-z bin must be known to better than 0.002(1 + z), and the width of the bin must be known to {approx}0.003(1 + z) if errors in cosmological measurements are not to be degraded significantly. A conventional approach is to calibrate these photometric redshifts with large sets of spectroscopic redshifts. However, at the depths probed by Stage III surveys (such as DES), let alone Stage IV (LSST, JDEM, and Euclid), existing large redshift samples have all been highly (25%-60%) incomplete, with a strong dependence of success rate on both redshift and galaxy properties. A powerful alternative approach is to exploit the clustering of galaxies to perform photometric redshift calibrations. Measuring the two-point angular cross-correlation between objects in some photometric redshift bin and objects with known spectroscopic redshift, as a function of the spectroscopic z, allows the true redshift distribution of a photometric sample to be reconstructed in detail, even if it includes objects too faint for spectroscopy or if spectroscopic samples are highly incomplete. We test this technique using mock DEEP2 Galaxy Redshift survey light cones constructed from the Millennium Simulation semi-analytic galaxy catalogs. From this realistic test, which incorporates the effects of galaxy bias evolution and cosmic variance, we find that the true redshift distribution of a photometric sample can, in fact, be determined accurately with cross-correlation techniques. We also compare the empirical error in the reconstruction of redshift distributions to previous analytic predictions, finding that additional components must be included in error budgets to match the simulation results. This extra error contribution is small for surveys that sample large areas of sky (>{approx}10{sup 0}-100{sup 0}), but dominant for {approx}1 deg{sup 2} fields. We conclude by presenting a step-by-step, optimized recipe for reconstructing redshift distributions from cross-correlation information using standard correlation measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Mitigating the impact of the DESI fiber assignment on galaxy clustering

In this paper, we present a simple strategy to mitigate the impact of an incomplete spectroscopic redshift galaxy sample as a result of fiber assignment and survey tiling. The method has been designed for the Dark Energy Spectroscopic Instrument (DESI) galaxy survey but may have applications beyond this. We propose a modification to the usual correlation function that nulls the almost purely angular modes affected by survey incompleteness due to fiber assignment. Predictions of this modified statistic can be calculated given a model of the two point correlation function. The new statistic can be computed with a slight modification to the data catalogues input to the standard correlation function code and does not incur any additional computational time. Lastly, we show that the spherically averaged baryon acoustic oscillation signal is not biased by the new statistic.

79 ASTRONOMY AND ASTROPHYSICS↗